Search PubMedSearch

SEARCH · Search PubMed

Results for “application count”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

A micro-scale method for liquid scintillation counting, applicable to radioimmunoassay of steroids and substances of comparable relative molecular mass.

A major expense of radioimmunoassay involving tritiated tracers is that of liquid scintillation counting. We present a micro-scale method that markedly reduces the cost of liquid scintillation counting. The radioimmunoassay is done in 10 X 50 mm tubes. The antibody-bound tracer is precipitated with a second antibody, the precipitate is resuspended in 0.1 ml of water, and 0.3 ml of dioxane is added. One milliliter of a toluene-based scintillation cocktail is added, and the tube is capped and placed in an adapter for liquid scintilation counting. When this method was applied to a double-antibody testosterone radioimmunoassay, it performed comparably to assays counted by the usual method.

Costs and Cost Analysis

The use of Stokes Raman scattering in time correlated single photon counting: application to the fluorescence lifetime of tyrosinate.

The decay kinetics of the tyrosinate form of tyrosine in aqueous solution, pH 11, were investigated by time correlated single photon counting using laser excitation. The lifetime of the single exponential decay was 30.5 +/- 0.2 ps. Stokes Raman scattering was used to determine the instrument response function and the advantages of this approach over the conventional Rayleigh scattering method are discussed.

Kinetics

Fractional intestinal absorption and retention of calcium measured by whole-body counting. Application of a power function model.

By application of a power function model, fractional intestinal calcium absorption was investigated with a new technique involving whole-body counting after successive oral and intravenous administration of standard doses of 47Ca. The fractional calcium retention 7 days after the oral load of 47Ca was also measured. Fractional calcium retention averaged 30.3% in normal subjects and 11.5% in 11 patients with intestinal malabsorption. In the same groups fractional calcium absorption averaged 46.6% and 16.4%, respectively. Fractional calcium retention and intestinal calcium absorption were significantly correlated to body surface area, and there was a well-defined relation between fractional retention and absorption of calcium...

Adult

Sequential determination of a combined gamma/beta and pure beta-emitter by gamma and liquid scintillation counting: application to the transport of metals across fish gills.

A combined gamma scintillation/liquid scintillation technique for the sequential determination of two radioactive tracers is described. The method was developed using a combined gamma/beta-emitter (57Co) and a pure beta-emitter (45Ca). First, the 57Co radioactivity was determined by counting the samples in a gamma scintillation analyzer in the energy region 80-165 keV. Next, the samples were counted in a liquid scintillation analyzer. Only one energy region was used to count both isotopes to maximize the counting efficiencies. From the difference between quenched and unquenched beta-spectra, the counting region was set from 0 to 256 keV. The counting efficiency was related to a quench-indicating parameter (tSIE) for both nuclides by fitting a rectangular hyperbola to the quench data. By subtracting the 57Co counts from the observed counts in the total window, 45Ca dpm values were obtained. It is shown that the method presented gives reliable and consistent results. The recoveries of both isotopes are independent of the quench level in a large tSIE range, although five times more radioactivity is required for 45Ca than for 57Co to obtain accurate and reproducible results. The method has been used to study mechanisms of metal transport across biological interfaces.

Animals

Photon counting imaging: applications in biomedical research.

Photon counting imaging, a technique capable of imaging at the single photon level, is finding applications in biological research and is providing unprecedented views of ultra-low light level phenomena. In combination with the optical microscope, this technique has provided a means of directly visualizing gene expression in single cells, imaging metabolites in tumor tissue and visualizing the chemiluminescence associated with oxidative metabolism in phagocytic cells. At the macroscopic level, it has greatly extended the sensitivity of detection in protein blots and has been applied as an image luminometer to assay microtiter plates. The technique holds great promise for use with fluorescence- and luminescence-based methods in many fields of research.

Animals

High-resolution particle analysis--its application to platelet counting and suggestions for further application in blood cell analysis.

The characteristics of an instrument for high-resolution particle analysis in flow are discussed. It employs a combination of hydrodynamic focusing, fluid resistors, and electronic techniques to achieve precision and ease of use heretofore unobtainable in a moderate-cost clinical instrument. Its application to whole blood platelet counting is discussed, and suggestions are made for its possible application to a wide variety of blood cell measurements.

Animals

Immunoglobulin E assayed after pepsin digestion by an automated and highly sensitive particle counting immunoassay: application to human cord blood.

We describe in this article a fully automated, universal assay for serum IgE after pepsin digestion of the sample and subsequent assay of the released Fc" epsilon fragment by particle counting immunoassay (PACIA). The sensitivity and the range of the assay were easily modulated by changing the concentration of dextran in the reaction medium. In the application to cord serum, the sensitivity reached 0.1 IU/ml in 30 min incubation time and with a throughput of 50 analyses per hour. Within-day and between-day coefficients of variation did not exceed 7.6% for IgE levels covering a wide range of the standard curve. Dependable accuracy was demonstrated by linearity tests, analytical recoveries (89% to 112%), and correlation with PRIST on 48 samples from children ages 1 to 14 yr (y = 0.97x + 5.92; r = 0.987). Minor discrepancies between the two methods were attributed to a slight serum effect in PRIST. PACIA applied to 348 cord serum samples demonstrated a statistically significant influence of sex and race on the cord IgE level. In European neonates boys had significantly (p = 0.019) higher geometrical mean cord IgE levels (n = 142; 0.46 IU/ml; range less than 0.10 to 30 IU/ml) than girls (n = 146; 0.33 IU/ml; range less than 0.10 to 8.0 IU/ml), which was attributed to a predominance of boys (chi 2 = 4.29; p less than 0.05) having more often elevated cord IgE (less than 1.20 IU/ml) than girls. Neonates of African-Asian origin had significantly (p less than 0.00005) higher cord IgE levels (n = 60; 1.05 IU/ml; range less than 0.10 to 125.0 IU/ml) than European neonates (n = 288; 0.39 IU/ml; range less than 0.10 to 30.0 IU/ml).

Animals

Sperm count depression in pesticide applicators exposed to dibromochloropropane.

Male pesticide applicators who worked with the nematocide dibromochloropropane (DBCP) were examined to determine the possible testicular toxicity from this exposure. Infertility and azoospermia which were first noted among factory workers exposed to DBCP were not observed among the applicators. Sperm count depression, however, was associated with the duration of exposure in the current year but not with exposure in past years. The extent of exposure to DBCP in the current year was also associated with an elevation of serum follicle stimulating hormone (FSH) but not of luteinizing hormone (LH). Sperm count depression was limited to applicators involved in irrigation setup work and in the calibration of equipment. These results suggest that the testicular toxicity of DBCP for men may occur in a shorter period than was previously reported, that the effect may be reversible in men with mild sperm count depression, and that public health measures might be directed at controlling specific application techniques.

Antinematodal Agents