Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Zinc Phosphate Cement”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

A comparison of the in vitro retentive strength of glass-ionomer cement, zinc-phosphate cement, and mineral trioxide aggregate for the retention of prefabricated posts in bovine incisors.

The purpose of this study was to compare the retentive strength of zinc-phosphate cement, glass-ionomer cement, and mineral trioxide aggregate (MTA) cement in the retention of prefabricated posts. The root canals of 60 bovine incisors were prepared and obturated with warm gutta-percha. Post space was prepared, the smear layer removed, and posts were luted with zinc-phosphate cement, glass-ionomer cement, or MTA. The specimens were stored at 37 degrees C and 100% humidity for 2 weeks, and then subjected to increasing axial tensile forces by an Instron machine until bond failure occurred. Data were analyzed by a one-way ANOVA and a Tukey-Kramer multiple comparison test. The retentive strengths of zinc phosphate and glass-ionomer cements were statistically equivalent, and significantly greater than MTA (p < 0.001), which suggests that zinc phosphate or glass-ionomer cement may be superior to MTA when used as luting agents for posts in endodontically treated teeth.

Aluminum Compounds↗

[Traction resistance of cast metal posts with and without retention, cemented with zinc phosphate cement in smooth and rough canals].

The purpose of this research was to test the traction resistance of cast posts and cores with and without roughness cemented with zinc phosphate cement in cuspids roots, with smooth and roughness canals walls. From the results of the tests and statistical analysis there was significant difference between roughness posts cemented in root canals with roughness walls and smooth posts cemented in smooth root canals. It was also analyzed, the retention of cast crows cemented on roughness posts and canals and it was concluded that posts are responsible for crows retention, when the cores were done at the correct way.

Cementation↗

Retention of cast posts cemented with zinc phosphate cement using different cementing techniques.

PURPOSE: This study compares the effect of different cementation techniques on the retention of cast posts and cores. MATERIALS AND METHODS: Twenty-four extracted single rooted human teeth were used in this study. After routine preparation of the root canals, the canal space was enlarged with reamers. Direct post patterns were made with acrylic resin. Castings were fabricated using Ni-Cr-Mb alloy. Zinc phosphate cement was used as a luting agent using 4 different methods of cement introduction to the root canal space. This created 4 treatment groups consisting of 6 teeth in each group. In Group A, the cement was applied over the posts only. For the specimens in Group B, the cement was introduced into the root canals with a spiral filler and applied over the posts. In Group C, cement was injected into the root canals and then applied over the posts. Finally, for the specimens in Group D, cement was injected into the root canals and a spiral was used to spread it into the root canals, and cement was also applied over the posts. After cementation, teeth were stored in saline solution. The tensile retentive force of cast posts was evaluated using the Instron testing machine (Instron, Canton, MA). RESULTS: The retention obtained by the 4 techniques differed significantly (p <.05). The highest tensile force to post dislodgment was observed in Group D, and the least was in Group A. Analysis of variance test revealed a highly significant difference between groups (p <.0001). According to the Fisher exact test, there was a significant increase in retention from Group A to Group D (p <.05). CONCLUSIONS: Under the conditions of this study, the injection of cement into a root canal space followed by the use of a spiral resulted in the highest level of post retention. Retention was reduced when cement was placed using a Lentulo spiral alone (Kerr/Sybron Corp, Romulus, MI), a Jiffy tube (Teledyne Water Pik, Allegheny Teledyne Co, Fort Collins, CO) alone, or by application to the post only. J Prosthodont 2001;10:37-41.

Acrylic Resins↗

The effective minimum cement thickness of zinc phosphate cement for luted non-precious crowns.

Non-precious metal crowns were prepared for natural teeth which were ground to a taper angle of 5 degrees. The movement of the crowns on teeth during repeated try-on seating was measured with a micrometer. Increasing the applied load from 2 to 10 kg resulted in an average crown movement of 63 micron. For most samples this movement continued when try-on was repeated. Casting irregularities were found to create furrows on some regions of the axial tooth surface during try-on seating. The diameter of the ADA specification consistency disk for zinc phosphate cement was found to depend strongly on the P:L ratio and the ambient temperature. The castings were cemented with zinc phosphate cement of controlled consistency. Cementation with a load of 10 kg gave rise to an average crown elevation of 54 micron and a range of measurements between -8 and 113 micron. The effective minimum cement thickness corresponding to this average was calculated to be 4.7 micron. Small negative values of elevation were attributed to deepening of tooth furrows during cementation. An analysis is given of data from the literature, relevant to the cement flow and irregularities in cement thickness.

Cementation↗

Encapsulated verses hand-mixed zinc phosphate dental cement.

Zinc phosphate cements are commonly supplied as two components, powder and liquid, and the proportions of the constituents are determined by operator experience. A capsulated system which is mechanically mixed has been marketed and this study investigated the performance of the encapsulated cement system. The mean fracture strength, standard deviation and associated Weibull Moduli (m) of encapsulated cements were determined by compressive fracturing 20 cement specimens filled directly from the mixing syringe or from narrower cement tubes. Pore distribution within the cylindrical specimens was determined using image analysis to assess the influence of the method of mould filling with the cement. The strength data showed variation in magnitude and consistency ranging from 44.6+/-13.7 MPa (m = 3.18+/-0.71) for cements filled directly from the syringe to 61.0+/-7.8 MPa (m = 8.35+/-1.87) for cements filled from cement tubes. Larger pores were found in specimens consolidated directly from the cement syringe. Mechanical mixing of the encapsulated cement resulted in air entrapment in the cement mix which manifested itself as large pores (over 200 microm diameter) within the cylindrical specimens. The smaller orifice of the cement tube compared with the syringe was considered to be responsible for eliminating the majority of the air entrapped in the cement mass during mixing. Whilst mechanical mixing of encapsulated cements is quicker and more convenient, the encapsulated specimens consolidated according to the manufacturers instructions from the syringe offered no significant advantage in terms of reliability or strength over hand-mixed cements in this investigation.

Biocompatible Materials↗

The effect of cold temperature mixing on the properties of zinc phosphate cement.

A series of proprietary zinc phosphate cements were evaluated after mixing on glass slabs at three different temperatures, 23 degrees, 6 degrees and -10 degrees C. Working time, setting time, diametral tensile strength, compressive strength and solubility were investigated. From the results of the tests the following conclusions were made: 1) As the temperature of the mixing slab was decreased, the amount of powder required to maintain a constatnt viscosity increased. 2) Compressive, tensile, and solubility values remained constant as the temperature of the mixing slab was decreased provided a consistent viscosity was maintained. 3) Mixing zinc phosphate cement substantially below the dew point is an acceptable practice provided the powder/liquid ratio is modified accordingly. 4) Although the setting time of zinc phosphate cement generally remained constant at temperatures below 6 degrees C, the working time continued to increase at -10 degrees C. 5) Mixing zinc phosphate cemment on a cold mixing slab increases the working time on the glass slab and decreases the setting time in an oral environment. Both of these alterations are clinically beneficial to the orthodontist.

Cold Temperature↗

Clinical studies of dental cements: V. Recall evaluation and a zinc phosphate cement.

Patients with restorations cemented with a reinforced zinc oxide-eugenol cement and a zinc phosphate cement were recalled after a four- to seven-year interval. No significant differences in clinical success were observed between restoration luted with the two cements. No significant difference in the incidence of caries at the restoration margins was noted between the cements.

Dental Restoration, Permanent↗

Influence of ultrasound, with and without water spray cooling, on removal of posts cemented with resin or zinc phosphate cements.

The efficacy of ultrasound, with and without water spray, was evaluated in vitro on the amount of force necessary to dislodge posts cemented with resin or zinc phosphate. Forty-two samples were divided into six groups: groups 1, 2, and 3, posts cemented with zinc phosphate; groups 4, 5, and 6, posts cemented with resin (Panavia F); groups 1 and 4 (controls), no ultrasound; groups 2 and 5, ultrasound without water spray; and groups 3 and 6, ultrasound with water spray. The Instron testing machine was used. Ultrasound without water spray significantly reduced (71%) the force necessary to displace posts cemented with Panavia F (p < 0.01); however, this value was similar to the efficacy of ultrasound with water spray for posts cemented with zinc phosphate (reduction of 75%). We conclude that cooling with ultrasound interferes with the force necessary for post removal, depending on the type of cement used.

Analysis of Variance↗

The fit of tapered posts in root canals luted with zinc phosphate cement: a histological study.

OBJECTIVES: Stress transmission to the root through passive fitting dental posts is partly influenced by the thickness of the cement layer between the post and the prepared root canal surface as well as the fit of the post in the root canal. The objective of this study was to compare the cement gap between the post surfaces and the root canals using five prefabricated, tapered, unthreaded titanium posts of different manufacturers, without and with cement. METHODS: Following the endodontic treatment with hand instruments of 100 intact anterior teeth, post spaces were prepared using opening drills of the corresponding size of post. Fifty posts were cemented with zinc phosphate cement into the roots for each system while another 50 posts were inserted into the canal without using the cement. After histological sectioning, the cement gap was measured at six sites for three times at the coronal, middle and apical regions between the root canal wall and the post surface under a light microscope before and after cementation. RESULTS: Before cementation, the highest overall cement gap was observed with the Dr Mooser post system (46 microm) and the lowest with the Velva post system and Cylindro-Conical system (30 microm). Significantly less (P<0.05) mean cement gap was observed with respect to the Erlangen post system (41 microm), the Dr Mooser post system (48 microm), the MP Pirec post system (34 microm) and Velva post system (33 microm) when compared with the Cylindro-Conical system (62 microm). The Cylindro-Conical system (79, 61 microm) and MP Pirec post system (25, 24 microm) demonstrated no significant difference (P>0.001) compared with Velva-Post (38, 20 microm) at the coronal and middle part, respectively (Mann-Whitney U-test, Boneferroni correction). Significant differences (P<0.001) were observed between the cement gap at the coronal and apical part for the Cylindro-Conical system (79, 46 microm), Dr Mooser post system (45, 56 microm) and MP Pirec post system (25, 52 microm). After cementation, the highest cement gap at the coronal part was obtained with the Cylindro-Conical system (79+/-21 microm) and the lowest with the MP Pirec post system (25+/-9 microm). However, at the apical end, the MP Pirec post system (52+/-89 microm) and Dr Mooser post system (56+/-16 microm) revealed the highest gap. SIGNIFICANCE: Form-congruence between the preparation drill and the post systems exhibited differences. The most consistent cement gap either at the coronal, middle or apical parts of the root canals was obtained with the Erlangen post system.

Cementation↗