Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Water Purification”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Virus, bacteriophages and water purification.

Water can be a vector of viral disease, but direct virological analysis of water has logistic and practical limitations. Viruses of major importance for water hygiene (e.g. hepatitis and gastro-enteritis viruses) cannot yet be grown in tissue culture. Therefore, as in bacteriological quality procedures, model organisms are required for the evaluation of virological quality of water and the effectiveness of virus removal by water treatment processes. On the basis of published information, the F specific RNA (FRNA) phages have been chosen for this purpose. For the enumeration of the phages a particular Salmonella typhimurium strain with an artificially introduced F plasmid was developed as a host strain and was found to give accurate and reliable results. FRNA phages were found in very high numbers (10(2)-10(5) pfu/ml) in all types of waste water investigated. FRNA phages are seldom found in non-faecally contaminated waste water. Surprisingly low numbers are found in faeces. FRNA phages in waste water effluent were found to be highly resistant to chloramines and relatively resistant to UV inactivation. The FRNA phages can thus effectively be used as indicator organisms for human pathogenic viruses in the evaluation of disinfection processes for water treatment plants.

Animals↗

[Production of mutagenic compounds during the water purification treatment of surface water].

In the last years many studies have reported the presence of mutagenic/carcinogenic compounds in treated waters. These substances can be present in raw water, but are also produced during drinking water purification. Mutagens are formed as by-products of chemical reactions between oxidants/disinfectants used in treatments and organic load of the raw water (humic and fulvic acids). The aim of this study was to evaluate the production of mutagenic substances during the main phases of the Po river water treatment ("PO3" plant) in Turin. Water samples (50 litres), collected from February 1989 to August 1990, were concentrated with XAD-2/XAD-8 resins mixture. Extracts were tested for mutagenicity at different doses (1, 2.5, 5 and 10 litres) by Ames Salmonella assay, using TA 100 and TA 98 strains, without microsome fraction (S9). Raw water was rarely mutagenic while, in particular at the highest doses (5 and 10 litres), sometimes showed toxic effect. After ozonation treatment only few samples were mutagenic with TA 100 strain, while 43% of the samples were mutagenic with TA 98. The following treatment of clariflocculation and chlorination with NaClO produced mutagens in 95% of the samples assayed with TA 100 and in 85% of the samples assayed with TA 98. The next GAC/sand filtration step seems to reduce the mutagenic load produced in the previous phases. Finally, drinking water after chlorination with ClO2 showed weak mutagenicity at 1 litre dose (26% and 21% of positive samples with TA 100 and TA 98 respectively) and this effect increased at the higher dosages.(ABSTRACT TRUNCATED AT 250 WORDS)

Carcinogenicity Tests↗

Elimination of botulinum neurotoxin (BoNT) type B from drinking water by small-scale (personal-use) water purification devices and detection of BoNT in water samples.

Seven small-scale drinking water purification devices were evaluated for their capacity to eliminate botulinum neurotoxin (BoNT) type B from drinking water. Influent water inoculated with toxic Clostridium botulinum cultures and effluent purified water samples were tested for the presence of BoNT by using a standard mouse bioassay and two commercial rapid enzyme immunoassays (EIAs). The water purification devices based on filtration through ceramic or membrane filters with a pore size of 0.2 to 0.4 microm or irradiation from a low-pressure UV-lamp (254 nm) failed to remove BoNT from raw water (reduction of < 0.1 log10 units). A single device based on reverse osmosis was capable of removing the BoNT to a level below the detection limit of the mouse bioassay (reduction of > 2.3 log10 units). The rapid EIAs intended for the detection of BoNT from various types of samples failed to detect BoNT from aqueous samples containing an estimated concentration of BoNT of 396,000 ng/liter.

Animals↗

A multi-purpose system for water purification and sea-water softening.

A novel technique that can be used for reacting toxic carbon dioxide (CO2) emissions from power plants and other combustion wastes with sea water is described. A chemical interaction between CO2 and the cations in sea water, with the pH electrolytically regulated, can precipitate almost all the calcium and magnesium ions, as well as some sodium and potassium ions, as carbonates and bicarbonates. The carbonates and bicarbonates thus prepared can then be mixed with ash to yield a building material. Sulfur ions will be neutralized with calcium and magnesium, and the remaining ions can be removed using reverse osmosis or some other method. The technology and equipment for purification are based on modules that can be used for industrial waste-water, sea water, solutions, and otherwise. The module for separation of sand and suspended coarse substances consists of a tank for flocculation, coagulation, and precipitation of solid particles; and a low-pressure hydrocyclone. The module for purification from oil and fine suspensions is based on column flotation, flotation with a special ejector, and adhesion flotation. The module for ions and colloids consists of an absorbing filter with zeolite, fly ash, and other absorbing materials. Using a laboratory model consisting of a special mini-plant, we processed 10 L of factory-waste water containing more than 20 g/L organic content (compare with the upper limit of 0.02 g/L allowed by the Ministry of Environmental Protection in Israel). After the experimental solution was treated and evaporated to a small bulk, the water obtained was almost clear. On the basis of the results in the model, we present a scaled-up process for the design, development, and production of equipment for and the assembly of a large installation for drainage and water purification.

Seawater↗

Assessment of drinking water quality of Borg el-Arab water purification plant.

Borg El-Arab drinking water purification plant takes its raw water from El-Noubaria Canal at the kilometer 95. EI-Noubaria canal gets its water from the Nile at two points. The main bulk of water comes from El-Riah El-Behiery, while the second source of water coming from El-Riah El-Nassery. There are four agricultural drains at the kilometer 53.0, 66.0, 71.9 and 85.4 which return back to the canal and represent the sources of pollution of the canal. Chemical, physical and trace elements analysis were carried out for raw and treated water of Borg El-Arab drinking water purification plant. It was found that the quality of treated water for the different parameter, are in agreement with the Ministry of Health Decree No 108/1995 for drinking water. Regarding total dissolved solids level, the quality of water was fair during Autumn and Summer as its value was 876.7 mg/l and 701.2 mg/l respectively, it was poor during spring as it reached 1113 mg/l, while during winter it was unacceptable (1312.7 mg/l) which exceed the higher permissible limit of the Ministry of Health Decree No 108/1995. This high TDS values make objectionable tastes in the public water supplied to Borg El-Arab city and the North West coast summer resorts. This taste of water provides no assurance to the public that such water is free of pathogens or toxic inorganic chemicals. So, we recommend El-Hager canal as new intake source for providing Borg El-Arab drinking water purification plant with raw water free from pollutants and low in total dissolved solids concentration.

Egypt↗

Evaluation of the purification capacity of nine portable, small-scale water purification devices.

A test was performed to evaluate the microbial and chemical purification capacity of nine portable, small-scale water purification filter devices with production capacity less than 100 L/h. The devices were tested for simultaneous removal capacity of bacteria (cultured Escherichia coli, Clostridium perfringens, Klebsiella pneumoniae and Enterobacter cloacae), enteric protozoans (formalin-stored Cryptosporidium parvum oocysts), viral markers (F-RNA bacteriophages) and microcystins produced by toxic cyanobacterial cultures. In general, the devices tested were able to remove bacterial contaminants by 3.6-6.9 log10 units from raw water. Those devices based only on filtration through pores 0.2-0.4 microm or larger failed in viral and chemical purification. Only one device, based on reverse osmosis, was capable of removing F-RNA phages at concentrations under the detection limit and microcystins by 2.5 log10. The present study emphasised the need for evaluation tests of water purification devices from the public safety and HACCP (Hazard Analysis and Critical Control Point) points of view. Simultaneous testing for various pathogenic/indicator microbes and microcystins was shown to be a useful and practical way to obtain essential data on actual purification capacity of commercial small-scale drinking-water filters.

Animals↗

Comparative study on chemical pretreatments to accelerate enzymatic hydrolysis of aquatic macrophyte biomass used in water purification processes.

In this study, enzymatic hydrolysis of two floating aquatic plants which are suitable for water purification, water hyacinth (Eichhornia crassipes) and water lettuce (Pistia stratiotes L.), was performed to produce sugars. Twenty chemical pretreatments were comparatively examined in order to improve the efficiency of enzymatic hydrolysis. As a result, the alkaline/oxidative (A/O) pretreatment, in which sodium hydroxide and hydrogen peroxide were used, was the most effective pretreatment in terms of improving enzymatic hydrolysis of the leaves of water hyacinth and water lettuce. The amount of reducing sugars in enzymatic hydrolysate of water lettuce leaves was 1.8 times higher than that of water hyacinth leaves, therefore water lettuce seems to be more attractive as a biomass resource than water hyacinth. Although roots of these plants contained large amounts of polysaccharides such as cellulose and hemicellulose, they generated less monosaccharides than from leaves, no matter which chemical pretreatment was tested.

Araceae↗

Modeling of an annular photocatalytic reactor for water purification: oxidation of pesticides.

Photocatalytic oxidation (PCO) over titanium dioxide (TiO2) is a "green" sustainable process for the treatment and purification of water and wastewater. However, the application of PCO for wastewater treatment on an industrial scale is currently hindered by a lack of simple mathematical models that can be readily applied to reactor design. Current models are either too simplistic or too rigorous to be useful in photocatalytic reactor design, scale-up, and optimization. In this paper a simple mathematical model is presented for slurry, annular, photocatalytic reactors that still retains the essential elements of a rigorous approach while providing simple solutions. The model extends the applicability of the thin-film model of photocatalytic reactors previously presented to include the case of geometrically thick photoreactors (i.e., those reactors in which the thickness of the annular zone is significant as compared to the outer radius of the reactor). The model uses a novel six-flux absorption-scattering model to represent the radiation field in the reaction space, which assumes that scattered photons follow the route of the six directions of the Cartesian coordinates. The model was successfully validated with experimental results from the photocatalytic oxidation of the pesticide isoproturon in an experimental reactor. The mathematical model presented may be used as a tool for the design, scale-up, and optimization of annular photocatalytic reactors for water treatment and purification.

Catalysis↗

Double catholyte electrochemical approach for preparing ferrate-aluminum: a compound oxidant-coagulant for water purification.

Ferrate is an excellent water treatment agent for its multi-functions in oxidation, disinfection, coagulation and adsorption, but its coagulation ability depends on its dosage and is after its oxidation. This paper focuses on preparing a new kind of ferrate combined with alum to enhance its coagulation function for water purification. An effective electrolysis reactor was designed and employed in the test. Some key parameters in the process of electrolysis concerning the preparation efficiency, such as the current density, temperature and alkalinity were also investigated. The proper conditions for ferrate-alum preparation were determined. Under the condition of 5 V given voltage, 6 h electrolyzing interval, below 2% alum concentration (in weight), a combined liquid ferrate-alum products was successfully prepared, which contained 0.0294 mol/L FeO4(2-) and 0.0302 mol/L total soluble ferron with 2% Al2O3. There was no insoluble ferron produced by controlling an optimum electrochemical condition.

Alum Compounds↗

Biocidal efficacy of a flocculating emergency water purification tablet.

Chlor-Floc (CF) emergency water purification tablets were tested for bactericidal, virucidal, and cysticidal efficacy in water at temperatures ranging from 5 to 25 degrees C. The minimal required log reduction was achieved for bacteria, Giardia muris, and rotavirus, but CF did not achieve the required log reduction of poliovirus at any of the temperatures or times investigated. The biocidal properties of the CF tablet were equivalent to if not greater than those of the Globaline iodine tablet, and the CF tablet was a more rapid cysticide under several potential use conditions. Therefore, it is a suitable substitute for iodine tablets for emergency purification of drinking water. Clarification of turbid waters was effective, but filtration through a cloth is necessary to prevent flocculated sediment from entering the canteen. The CF tablets met military requirements for emergency water purification and are safe and acceptable for use by the military.

Journal Article↗

Behavior of organic polymers in drinking water purification.

Synthetic organic polymers used to purify drinking water are severely limited in that their impurities and by-products harm human health. In this study, the undesired effects resulted from chlorination and the enhanced attenuation of toxic organic compounds in drinking water from using synthetic organic polymer coagulants were investigated. In the simulated drinking water purification processes, synthetic organic polymers were used as coagulant aids, reacted with a disinfectant(chlorine) and formed a large number of volatile organic compounds (VOCs). Chloroform and benzene which, are carcinogenic compounds, had the maximum formation potential. Experimental results indicated that the total formation potential of these disinfection by-products significantly increased in the presence of turbidity. On the other hand, adding organic polymers to the coagulation systems resulted in more extensive remove of toxic organic compounds and turbidity. In coagulation and flocculation processes, the formation of clay/polymer complexes can facilitate the removal of toxic organic compounds in contaminated water.

Aluminum Silicates↗

Evaluation of traditional filters for water purification in Burkina Faso.

Most tropical water springs are polluted with microbial agents such as faecal coliforms and streptococci, so for the present and the forseeable future, boreholes are considered to be the most appropriate system for reducing the bacterial contamination of water. However, from source to consumer, safe drinking water usually becomes polluted with faecal bacteria. This observation which calls into question the success of the International Drinking Water Supply and Sanitation Decade should stimulate efforts to provide a reliable means of water purification. The use of traditional filters prepared with sand, gravel and charcoal has been proposed but our results reveal that they give no guarantee for the purification of bacteria-polluted water.

Burkina Faso↗

A water purification system for laboratory use.

A water purification system is described, capable of producing Type I water upon demand at multiple locations up to 700 feet, from the purifying equipment. Tap water is initially treated employing reverse osmosis, followed by treatment with activated charcoal and mixed anion/cation exchange resins. The resultant Type I quality water is maintained by means of a recycling loop until removal upon demand. The current cost of producing water of this quality is $0.03 per liter, exclusive of capital and installation costs.

Dialysis↗

Thyroid adaptation to chronic tetraglycine hydroperiodide water purification tablet use.

Tetraglycine hydroperiodide tablets purify water by liberating 8 mg free iodine/tablet. The effects of ingesting four tablets daily for 3 months on thyroid size, function, and radioactive iodine uptake were studied prospectively in eight healthy volunteers. Serum inorganic iodide increased from 2.7 to approximately 100 micrograms/dL. Urinary iodide excretion rose 150-fold from a pretreatment mean of 0.276 to 40 mg/day. Radioactive iodine uptake was less than 2% after 7 days and remained below 2% in all subjects at 90 days. Mean serum T4 and T3 declined after 7 days. T4 remained below baseline, whereas T3 had recovered by the end of the treatment period. Serum TSH and the TSH response to TRH rose significantly after 7 days and remained elevated at 3 months. The average thyroid volume, determined by ultrasound, increased by 37%. Neither hyperthyroidism nor hypothyroidism was observed. The mean thyroid volume in seven subjects available for repeat determinations an average of 7.1 months after the study was not different from the baseline value. In normal subjects, a reversible TSH-dependent thyroid enlargement occurs in response to the iodine load from daily use of tetraglycine hydroperiodide water purification tablets.

Adaptation, Physiological↗