Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ultrasonography, Doppler, Duplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

[Doppler-duplex ultrasonography in the diagnosis of cavernous portal vein].

UNLABELLED: Prehepatic portal hypertension caused by cavernous transformation of the portal vein has been more and more considered as a multiorgan disease with circulatory changes in numerous organs related to systemic and splanchnic vascular network [1]. Honeycomb-like, spongy, cavernous portal vein is a rare clinical and pathoanatomical entity which usually results from portal vein thrombosis. Recanalization and neovascularization processes lead to cavernomatous transformation of the portal vein lumen and formation of periportal collateral hepatopetal venous varices (Petren's veins) [5, 6]. Recently, with Doppler ultrasonography and angiography cavernous portal vein has been identified as the cause of prehepatic portal hypertension. Usage of color Doppler and duplex Doppler ultrasonography has greatly contributed to diagnostic efficiency, while therapeutically, the disease remains a serious and controversial problem. METHODS: At the Institute of Digestive Diseases, Clinical Centre of Serbia, 8 patients with cavernous portal vein were studied in the period 1995-1997. Real-time duplex and color Doppler ultrasonography (Toshiba-SSA 100A with sector duplex probe 3.75 MHz, and 9 ATL with color Doppler convex duplex probe 3.5 MHz) were used. Indirect (arterial) portography was used for imaging of lienoportal system in the venous phase of angiography as follows: catheterization (Seldinger's technique) of the coeliac trunk or lienal artery, and catheterization of the superior mesenteric artery. Indirect portography was performed by injection of 60-80 ml of the contrast medium by an automatic pump, at 10-14 ml/sec, i.e. 8-10 ml/sec by the digital technique [7]. Peroral fiberendoscopy was performed in all patients by Olympus GIF-XQ 10 endoscope. RESULTS: In our study the conventional ultrasonographic examination failed to provide an appropriate image of the normal portal vein. In hepatoduodenal ligament multiple tubular and round structures were seen, revealing an atypical honeycomb or spongycavernous shape of the venous lumen (Figs. 1 and 2). Doppler ultrasonography of the lumen of these venous collateral structures revealed a continuous, hypokinetic flow, mid-rate 7.4 cm/sec, which was always hepatopetally directed (to the liver). Color Doppler ultrasonography detected extensive portosystemic collateralls in all patients, and varices in the gallbladder wall in 1 patient. The results of indirect portography correlated well with Doppler ultrasonographic findings. In all patients hepatopetal flow was found (Figs. 3 and 4). The aetiology was diverse: idiopathic, liver cirrhosis, haematological diseases, Crohn's disease and Marfan's syndrome. Two patients had IV degree varices in the distal third of the oesophagus, and 4 patients had II/III degree varices. Patients with posthepatic liver cirrhosis and Crohn's disease had no varices in the distal third of the oesophagus and gastric fornix. DISCUSSION: Since Pick (1909) described this malformation as the hepatopetal collateral, the haemodynamic concept of this entity has not been changed. Doppler ultrasonography and angiography confirm that the blood flow in cavernomas is hepatopetal, i.e. compensated and functional. Cavernous transformation of the portal vein is clinically manifested by bleeding from oesophagogastric varices. Haemathemesis is the most alarming complication and may be the first clinical sign. The haemorrhage is usually recurrent and profuse, but in most cases it is tolerated well owing to preserved hepatic function in patients without liver cirrhosis [19]. Portosystemic collateral circulation may take place via retroperitoneal and other spontaneous venous shunts, not involving the left gastric vein or vv. gastricae breves, when oesophagogastric varices are absent (our patient with Crohn's disease and posthepatitic B cirrhosis). Splenomegaly with hypersplenism is always present with cavernous transformation of the portal vein, and usually precedes the occurrence of gastrointestinal hae

Blood Flow Velocity↗

Gastroepiploic artery coronary bypass graft: non-invasive patency evaluation using color and duplex Doppler ultrasonography.

OBJECTIVE: Color and duplex Doppler ultrasound and digital subtraction angiography were compared for the evaluation of graft patency of the gastroepiploic artery (GEA). METHODS: In 77 observations, ultrasound and digital subtraction angiography were compared. The coronary resistance index (cRI) was defined as the maximal systolic flow velocity minus the maximal diastolic flow velocity, divided by the maximal systolic flow velocity. On digital subtraction angiography, the graft was considered patent, occluded, or patent but non-functional. Grafts were defined as non-functional when they had a diameter of less than 5F with the absence of opacification of the native coronary artery. RESULTS: Of the 77 observations, 64 GEAs were patent angiographically, three were occluded and ten grafts were considered as patent but non-functional. Using color and duplex ultrasound, the GEA was identified in 65 out of 77 observations. There were no cases of false positive visualization of the GEA. All sonographically detected non-functional grafts (n = 7) had a cRI of greater than 0.60. When the non-visualized grafts are considered either non-functional or occluded, a cut-off value for a cRI of 0.60 results in a sensitivity and specificity of 100 and 75%, respectively. CONCLUSION: We propose ultrasound as a primary screening tool for evaluating graft patency. While color Doppler is a suitable technique for graft visualization, spectral analysis with the calculation of a cRI is required for functional evaluation.

Adult↗

Thrombosis of the deep femoral vein: a potential pitfall of color flow duplex Doppler ultrasonography.

This case illustrates a potential pitfall of color flow duplex Doppler ultrasonography with compression in the evaluation of suspected deep venous thrombosis (DVT). Because of its low cost, accuracy, and noninvasiveness, ultrasonography is the appropriate first choice in the evaluation of suspected DVT, but there does exist the possibility of a false-negative examination. Magnetic resonance venography (MRV) should be reserved for cases in which there is a high clinical suspicion for DVT, as well as either morbid obesity that would limit the evaluation of deep pelvic and deep femoral veins or conflicting results of other imaging studies. All cases of suspected thrombosis, including those not adequately evaluated by ultrasonography, can be accurately assessed by MRV, which is not as invasive as standard venography.

Adult↗

Portal hemodynamics in fulminant hepatic failure as assessed by duplex Doppler ultrasonography.

Portal hypertension usually occurs in patients with fulminant hepatic failure (FHF). There is, however, no information on portal venous hemodynamics in patients with FHF. Therefore, we studied the portal venous hemodynamics in patients with FHF using duplex Doppler ultrasonography. We measured the portal vein diameter, flow velocity, and volume flow with duplex Doppler ultrasonography in 29 patients with FHF and 15 patients with uncomplicated acute viral hepatitis. No significant difference was observed in the portal vein parameters in the two groups. Nineteen patients with FHF survived. No difference in portal flow velocity and flow rate was observed between survivors and nonsurvivors. A significantly lower portal flow velocity was observed in nine patients of FHF with ascites compared with those without ascites (12.29+/-2.81 vs 16.26+/-4.87 cm/sec; P < 0.01). Portal hemodynamics do not significantly change in fulminant hepatic failure; therefore, it has no prognostic significance.

Adult↗

Duplex Doppler ultrasonography of subclavian steal syndrome--three case reports.

Three cases of subclavian steal syndrome were detected by duplex Doppler ultrasonography. Ultrasonography demonstrated retrograde flow with to-and-fro pattern in the right vertebral artery in two cases, and reflux with diastolic flow deceleration in one case. Interventional treatment with stenting was successfully performed in two cases and conservative treatment was given in one case. Ultrasonography is an effective noninvasive method for the evaluation of the vertebral artery, and should become a routine part of cerebrovascular examinations.

Aged↗

The role of duplex-doppler ultrasonography in the diagnosis of renal dysfunction and hepatorenal syndrome in patients with liver cirrhosis.

BACKGROUND/AIMS: Kidney dysfunction commonly develops in patients with liver cirrhosis. Renal failure develops due to renal vascular constriction and can be present weeks or even months before clinical signs or increased levels of blood urea nitrogen or serum creatinine concentrations become detectible. The objective of this study was to analyze the value of renal interlobar arterial resistance index, measured by duplex-Doppler ultrasonography for detecting early impairment of renal function in patients with liver cirrhosis and its possible use in detecting a subgroup of patients with a higher risk of developing hepatorenal syndrome. METHODOLOGY: The patients were divided into three groups: patients with liver cirrhosis and normal renal function (n=31), patients with liver cirrhosis and renal failure but without hepatorenal syndrome criteria (n=9), and patients with hepatorenal syndrome (n=6). The interlobar arterial resistance index was estimated with duplex Doppler ultrasonography, and liver and renal function tests were measured in all patients. RESULTS: The average value of interlobar arterial resistance index in patients with hepatorenal syndrome (0.74+/-0.01) was statistically significantly higher than interlobar arterial resistance index values measured in liver cirrhosis patients without the signs of azotemia (0.65+/-0.03) or in those with liver cirrhosis and kidney dysfunction, but without hepatorenal syndrome (0.67+/-0.01). In all patients with hepatorenal syndrome the value of interlobar arterial resistance index was over 0.70. In the group of patients with liver cirrhosis and kidney dysfunction, but without hepatorenal syndrome, interlobar arterial resistance index was below 0.70 in seven, whereas in the remaining two interlobar arterial resistance index was above 0.70. In those patients renal dysfunction displayed a progressive form and hepatorenal syndrome developed. CONCLUSIONS: Duplex-Doppler ultrasound of intralobar arteries is a simple, effective and non-invasive method which enables the early detection of renal hemodynamic disturbances in patients with liver cirrhosis even before renal dysfunction becomes clinically evident. It also makes possible the identification of a subgroup of patients with liver cirrhosis who are at higher risks for developing hepatorenal syndrome.

Adult↗

[Duplex Doppler ultrasonography in the diagnosis of deep venous thrombosis of the lower extremities].

INTRODUCTION: The aim of this study was to investigate the role of duplex Doppler ultrasonography in diagnosis of deep venous thrombosis (DVT) of the lower extremities. MATERIAL AND METHODS: During a 2-year period, 860 patients were examined by duplex Doppler sonography. Among these, 619 (72%) were women and 241 (28%) men, with the age-range of 16-91; (mean 56,2) years. Siemens Versa Pro colour doppler was used, with 7MHz transducers. Findings were categorized into four categories: 1. deep venous thrombosis (DVT); 2. pathology predominantly related to superficial veins without DVT; 3. pathology of superficial and deep veins; 4. normal findings. RESULTS: 185 (21%) patients had DVT, 366 (42.5%) patients had predominant pathology of superficial veins: postthrombotic syndrome, superficial thrombophlebitis and varicose veins. 128 (14.9%) patients had pathology of superficial and deep veins. Normal findings were found in 181 (21.1%) patients. COCNCLUSIONS: Various vascular and nonvascular diseases may mimic deep venous thrombosis, and that is why US should be used whenever possible to avoid unnecessary anticoagulant therapy.

Adolescent↗

Diagnosis of pancreatic graft rejection by duplex-Doppler ultrasonography.

The utility of duplex-Doppler ultrasonography (US) in the diagnosis of pancreatic graft rejection was evaluated in 9 patients. The examinations assessed the resistive index (RI) of arteries within the graft parenchyma, the homogeneity and echogenicity of the parenchyma, and the presence of fluid collections around the grafts. For the first 3 days after transplantation, the RI was found to be high. Subsequently, it decreased, and when the graft was in a stable condition, the mean RI was 0.63. With acute rejection episodes, the RI increased to a mean of 0.68 (p=0.002). Thus the increase in mean RI was small but significant. If serial US examinations were performed then an increase in RI, above an individual stable base-line level, was more apparent. After successful anti-rejection treatment, the RI decreased again. In 1 case with chronic rejection, the RI was found to be high, and the parenchyma was non-homogenous with high echogenicity. With pancreatitis, the RI did not change significantly. In 2 patients, fluid collections--which later resolved spontaneously--were seen around the grafts. In 1 patient, an arterial pulsation, which had been detectable previously, was found to be absent, and arterial thrombosis was confirmed at operation. In conclusion, serial duplex-Doppler US may be useful for monitoring pancreatic grafts and the RI may assist in the diagnosis of pancreatic graft rejection.

Adolescent↗

Chronic post-traumatic pseudoaneurysm of the abdominal aorta diagnosed by duplex Doppler ultrasonography. A case report.

Traumatic pseudoaneurysm of the abdominal aorta is a rare pathology. To date aortography, CT and ultrasonography are the only diagnostic tools available for establishing the diagnosis. We report a case in which the presence of a continuous bidirectional flow in the neck of the pseudoaneurysm, as seen with duplex Doppler ultrasonography, confirmed the diagnosis.

Accidents, Traffic↗

Effects of propranolol compared with clonidine on portal haemodynamics: a double-blind cross-over study using duplex-Doppler ultrasonography.

BACKGROUND: Patients with liver cirrhosis and large oesophageal varices run a high risk of digestive haemorrhage due to the rupture of oesophageal varices, an event associated with a high mortality. At present, the only treatment for the prevention of first bleeding from oesophageal varices on which there is general agreement is drug-based. In order to tailor drug treatment to the requirements of individual patients more precisely, an ever-increasing number of drugs is being investigated. DESIGN: Double-blind cross-over study. METHODS: Sixteen cirrhotic patients with large oesophageal varices were studied by means of duplex-Doppler ultrasonography to determine variations in portal haemodynamics after oral administration of 0.150 mg clonidine and to compare these with the variations observed after oral administration of 40 mg propranolol. RESULTS: Propranolol caused a significant reduction in maximum portal flow velocity (P < 0.001), whereas clonidine failed to cause any such variation (P = 0.194). Considering as responders those patients who exhibited at least a 10% decrease in maximum portal flow velocity, 11 patients responded to propranolol; of these, three also responded to clonidine. No patient responded only to clonidine. CONCLUSION: The absence of any effects on the parameters of portal haemodynamics would appear to deny clonidine any significant role in preventing first bleeding resulting from the rupture of oesophageal varices.

Administration, Oral↗

[Assessment of erectile dysfunction with Doppler-duplex ultrasonography].

OBJECTIVE: To evaluate the penile echo Doppler study and review the anatomy, perfusion, innervation and physiology of erection. METHODS: The technique, spectral morphological changes of the cavernous arteries after drug-induced erection, modifications and normal values are described. RESULTS/CONCLUSION: Impotence or erectile dysfunction, which is defined as the inability of the male to achieve or sustain an erection sufficient for successful sexual intercourse, is a benign condition with an important impact on the wellbeing of the patient. Statistical studies have shown a high age-dependent prevalence in healthy subjects and an association with different conditions in patients. To establish whether impotence is organic or not and to identify its underlying cause require submitting the patient to not a few diagnostic tests. Since most of the cases of organic impotence are of vascular origin, it is necessary to utilize a diagnostic method that can identify patients with an underlying vascular disorder (the most common cause) and distinguish those with arteriogenic impotence from those with insufficiency of the complex corporeal veno-occlusive system.

Erectile Dysfunction↗

The effect of nilvadipine on bloodflow in the dorsal pedis artery in type 2 diabetic patients--a study using duplex Doppler ultrasonography.

The effects of nilvadipine on the peripheral circulation in the lower extremities using a duplex system of two-dimensional colour and pulse Doppler ultrasonography were studied in 32 patients with type 2 diabetes mellitus and mild essential hypertension. The patients (19 men and 13 women) were randomly divided into treatment and control groups. The anatomical cross-sectional area and blood flow index of the dorsal pedis artery were determined by colour and pulse Doppler ultrasonography before and 60 min after administration of 4 mg nilvadipine or placebo. Pulse rate and blood pressure were measured simultaneously. There were no significant changes in pulse rate or blood pressure after administration of either drug. Both cross-sectional areas (from 4.3 +/- 0.4 to 5.2 +/- 0.5 mm2, p < 0.05) and blood flow index (from 40.3 +/- 4.3 to 58.8 +/- 9.0, p < 0.05) were significantly increased in the treatment group, whereas there were no significant changes in either measurement in the control group. The findings showed that a single administration of nilvadipine increases blood flow in the dorsal pedis arteries of diabetic patients.

Arteries↗

[Duplex Doppler ultrasonography of intra-renal arteries. Normal and pathological aspects].

Duplex Doppler ultrasonography may explore renal perfusion in frequent diseases such as renal obstruction, reno-vascular hypertension, acute or chronic renal failure or diabetic renal complications by measuring Pourcelot's resistive index (RI) of renal parenchyma arteries for each kidney. A statistical and prospective study was performed on 574 patients. In healthy patients, the RI values, equal for each kidney were included in 0.45 and 0.7 (mean RI = 0.59). For other values, there was a renal pathology. Patients with idiopathic hypertension (mean RI = 0.59) or non obstructive dilatation (mean RI = 0.61) did not have an RI significantly different from healthy patients. In cases of renal obstruction, there was a significant increase in the RI for the pathological kidney (mean RI of 0.73). The sensitivity and the specificity was 100% for acute obstructions examined during the first 48 hours. In contrast, in case of renal artery stenosis greater than 70% there was a significant decrease in the RI for pathological kidney. So the RI increased significantly in both kidneys: when there was renal failure with active disease within the tubulo-interstitial compartment (mean RI of 0.77); in all cases of diabetic nephropathy (mean RI of 0.74) where the RI increased early before laboratory signs. Duplex Doppler ultrasonography may be an original method for renal explorations by providing not only morphological data but also physiological data with the perfusion study.

Adolescent↗

Genital duplex Doppler ultrasonography before and after sexual stimulation in women with sexual dysfunction: gray scale, volumetric, and hemodynamic findings.

OBJECTIVE: To report gray scale, volumetric, and duplex ultrasound data before and after sexual stimulation in a large population of women with sexual dysfunction. DESIGN: Retrospective review of women with sexual dysfunction. SETTING: An academic center. PATIENT(S): Pre- and postmenopausal women with sexual dysfunction. INTERVENTION(S): None. MAIN OUTCOME MEASURE(S): This is an Institutional Review Board-approved retrospective study of 142 women who underwent duplex Doppler ultrasound (DDU) arousal testing for sexual dysfunction. RESULT(S): This study revealed that DDU was able to record morphologic, volumetric (clitoral and corpora spongiosa diameters), and hemodynamic (peak systolic and end-diastolic) changes in women with sexual dysfunction before and after sexual stimulation. Resistive index measurements, which are indicative of veno-occlusive function, did not significantly change before and after arousal in both the clitoris and corpora spongiosa. We also found a correlation between genital diameter and genital end-diastolic velocity value. Gray scale scanning revealed tunical thickening or plaque in several patients who sustained blunt perineal trauma. CONCLUSION(S): The role of DDU in the management of women with sexual dysfunction remains to be determined; however, end-diastolic velocity values suggest that this parameter has an important physiologic implication as a direct determinant of genital engorgement.

Adult↗

Effect of cisapride on portal haemodynamics in patients with liver cirrhosis using duplex Doppler ultrasonography.

PURPOSE: Cisapride, a benzimide derivative, is a gastrointestinal prokinetic agent without dopamine-antagonistic or cholinomimetic effects. This study aims at assessing the effect of cisapride oral administration on portal flow in patients with advanced post hepatitic cirrhosis using duplex Doppler ultrasound (US). METHODS: A total of 12 patients with post-hepatitic liver cirrhosis were included in the study. Duplex Doppler sonographic examinations were performed before and after treatment. The subjects received 10 mg cisapride before starting the measurement procedure and then three times a day for 2 days. Portal haemodynamics including vessel diameters (mm), mean flow velocities (cm/s), blood flows (ml/min) were investigated. RESULTS: Mean portal vein diameters, mean portal flow velocity and portal blood flow volume showed decreases of 18.6, 22.1 and 43.6% (P<0.001), respectively. After cisapride administration the portal vein diameter did not change in two patients and the portal vein velocity did not change in three patients. No significant change was found in systolic blood pressure, diastolic blood pressure or pulse rate after the administration of cisapride. CONCLUSION: In this study, it was demonstrated that oral administration of cisapride results in a significant reduction of portal blood flow but there were no changes in heart rate or systolic pressure in patients with cirrhosis of the liver.

Adult↗

[A test object for quality control of the instrument for doppler (duplex) ultrasonography, based on the Draft IEC 61685 Standard].

PURPOSE: The authors, forming part of a multicenter project funded by the European Community, summarize the validation of a tissue-mimicking flow Doppler test object and of procedures for testing medical diagnostic Doppler equipment. The results of the project are expected to contribute to a future international IEC Standard concerning flow Doppler test objects (Draft IEC 61685 Standard) and for the European Medical Device Directive (MD 93/42/EEC). METHODS: Within this project a test protocol was developed that includes a set of different procedures, suitable for checking Spectral and Colour Doppler systems. The performance parameters for describing the image quality as well as the accuracy and the correct functioning of a system are in accordance with the definitions made in the Draft IEC 61685 Standard. RESULTS: A survey of the design and materials used for this Doppler test object will be presented with a special emphasis on the suitability of the procedures for routine measurement of performance parameters in hospitals. CONCLUSION: The test object satisfies the requirements of the Draft IEC 61685 Standard. The test procedures in combination with this test object can be used for checking different transducer models with nominal frequencies between 2.5-10.0 MHz.

Blood↗

Determination of sixty percent or greater carotid artery stenosis by duplex Doppler ultrasonography.

PURPOSE: The Asymptomatic Carotid Atherosclerosis Study, demonstrating the benefit of carotid endarterectomy for symptom-free patients with 60% or greater carotid artery stenosis, has given rise to the need for development of screening parameters for detection of these lesions. Traditional duplex categories (50% to 79%, 80% to 99%) are not applicable. We sought to develop duplex criteria for determination of 60% or greater carotid artery stenosis by comparison with arteriography. METHODS: The duplex scans and arteriograms of 110 patients (210 carotid arteries), obtained within 1 month of each other, were reviewed by blinded readers. Arteriographic stenosis was determined by the method of the Asymptomatic Carotid Atherosclerosis Study. Duplex measurements of peak systolic velocity (PSV) and end-diastolic velocity (EDV) were recorded, and ratios of velocities in the internal and common carotid arteries (ICA, CCA) were calculated. Sensitivity, specificity, positive and negative predictive values (PPV, NPV), and accuracy were determined, and receiver-operator characteristic curves were generated. RESULTS: Interobserver agreement for measurement of arteriographic stenosis was "almost perfect" (kappa = 0.86). The criteria determined for detection of 60% or greater stenosis were as follows: PSVICA > 170 cm/sec (sensitivity 98%, specificity 87%, PPV 88%, NPV 98%, accuracy 92%), EDVICA > 40 cm/sec (sensitivity 97%, specificity 52%, PPV 86%, NPV 86%, accuracy 86%), PSVICA/PSVCCA > 2.0 (sensitivity 97%, specificity 73%, PPV 78%, NPV 96%, accuracy 76%), EDVICA/EDVCCA > 2.4 (sensitivity 100%, specificity 80%, PPV 88%, NPV 100%, accuracy 88%). If all of the above criteria were met, 100% accuracy was achieved. CONCLUSION: It is concluded that 60% or greater carotid artery stenosis can be reliably determined by duplex criteria. The use of receiver-operator characteristic curves allows the individualization of duplex criteria appropriate to specific clinical situations of patient screening for lesions (high sensitivity and NPV) or use as a sole preoperative imaging modality (high PPV). Individual vascular laboratories must validate their own results.

Blood Flow Velocity↗

Current applicability of duplex Doppler ultrasonography in pancreatic head and biliary malignancies.

In most patients with a pancreatic head carcinoma or a cholangiocarcinoma of the liver (Klatskin tumour) US is the first imaging modality. Tumour detection using US can exceed that of CT. For small tumours, endosonography or ERCP is recommended. Enlarged lymph nodes are not a major diagnostic parameter, because a reliable differentiation between reactive and malignant lymph nodes is generally not possible. Very tiny liver and peritoneal metastases are missed by the current imaging modalities including US and only detectable by laparoscopy and/or laparoscopic US. Tumour involvement of the portal venous system is an important determinant for irresectability which can often be assessed by duplex Doppler US obviating invasive or expensive imaging modalities. In pancreatic head carcinoma an abnormal pulsed Doppler signal is highly suspicious for involvement of the portal venous system. However, a normal pulsed Doppler signal does not exclude involvement at all. In Klatskin tumour, Doppler US had an accuracy of 91% compared with surgical findings in predicting portal venous involvement. In most cases of pancreatic head carcinoma or Klatskin tumour, US can assess irresectability. However, assessment of curative resectability in these tumours remains a problem.

Bile Duct Neoplasms↗