Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Tomography, Optical”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Image reconstruction in optical tomography.

Optical tomography is a new medical imaging modality that is at the threshold of realization. A large amount of clinical work has shown the very real benefits that such a method could provide. At the same time a considerable effort has been put into theoretical studies of its probable success. At present there exist gaps between these two realms. In this paper we review some general approaches to inverse problems to set the context for optical tomography, defining both the terms forward problem and inverse problem. An essential requirement is to treat the problem in a nonlinear fashion, by using an iterative method. This in turn requires a convenient method of evaluating the forward problem, and its derivatives and variance. Photon transport models are described for obtaining analytical and numerical solutions for the most commonly used ones are reviewed. The inverse problem is approached by classical gradient-based solution methods. In order to develop practical implementations of these methods, we discuss the important topic of photon measurement density functions, which represent the derivative of the forward problem. We show some results that represent the most complex and realistic simulations of optical tomography yet developed. We suggest, in particular, that both time-resolved, and intensity-modulated systems can reconstruct variations in both optical absorption and scattering, but that unmodulated, non-time-resolved systems are prone to severe artefact. We believe that optical tomography reconstruction methods can now be reliably applied to a wide variety of real clinical data. The expected resolution of the method is poor, meaning that it is unlikely that the type of high-resolution images seen in computed tomography or medical resonance imaging can ever be obtained. Nevertheless we strongly expect the functional nature of these images to have a high degree of clinical significance.

Image Processing, Computer-Assisted↗

Volume image reconstruction for diffuse optical tomography.

Optical tomography is a potential diagnostic method for visualizing optical properties of tissues in vivo. We present an optical tomography method that has been designed for imaging of the human testes, particularly for spectroscopic tumor differentiation. In this application we need to compute three-dimensional distributions of the optical contrast (absorption coefficient) in the tissue in real time. Thus we have given special care to elaborate an efficient inverse algorithm that takes the limitations of spatial resolution and data space point density into account. Our inverse solution is based on a linearization approach and a dedicated object space discretization. Furthermore, we introduce the concept of fuzzy voxels, which enables a reconstruction-inherent image smoothing.

Algorithms↗

Parallel programming of gradient-based iterative image reconstruction schemes for optical tomography.

Optical tomography (OT) is a fast developing novel imaging modality that uses near-infrared (NIR) light to obtain cross-sectional views of optical properties inside the human body. A major challenge remains the time-consuming, computational-intensive image reconstruction problem that converts NIR transmission measurements into cross-sectional images. To increase the speed of iterative image reconstruction schemes that are commonly applied for OT, we have developed and implemented several parallel algorithms on a cluster of workstations. Static process distribution as well as dynamic load balancing schemes suitable for heterogeneous clusters and varying machine performances are introduced and tested. The resulting algorithms are shown to accelerate the reconstruction process to various degrees, substantially reducing the computation times for clinically relevant problems.

Algorithms↗

A haemodynamic response function model in spatio-temporal diffuse optical tomography.

Diffuse optical tomography (DOT) is a new and effective technique for functional brain imaging. It can detect local changes in both oxygenated and deoxygenated haemoglobin concentrations in tissue based on differential absorption at multiple wavelengths. Traditional methods in spatio-temporal analysis of haemoglobin concentrations in diffuse optical tomography first reconstruct the spatial distribution at different time instants independently, then look at the temporal dynamics on each pixel, without incorporating any temporal information as a prior in the image reconstruction. In this work, we present a temporal haemodynamic response function model described by a basis function expansion, in a joint spatio-temporal DOT reconstruction of haemoglobin concentration changes during simulated brain activation. In this joint framework, we simultaneously employ spatial regularization, spectral information and temporal assumptions. We also present an efficient algorithm for solving the associated large-scale systems. The expected improvements in spatial resolution and contrast-to-noise ratio are illustrated with simulations of human brain activation.

Algorithms↗

Physiological system identification with the Kalman filter in diffuse optical tomography.

Diffuse optical tomography (DOT) is a noninvasive imaging technology that is sensitive to local concentration changes in oxy- and deoxyhemoglobin. When applied to functional neuroimaging, DOT measures hemodynamics in the scalp and brain that reflect competing metabolic demands and cardiovascular dynamics. Separating the effects of systemic cardiovascular regulation from the local dynamics is vitally important in DOT analysis. In this paper, we use auxiliary physiological measurements such as blood pressure and heart rate within a Kalman filter framework to model physiological components in DOT. We validate the method on data from a human subject with simulated local hemodynamic responses added to the baseline physiology. The proposed method significantly improved estimates of the local hemodynamics in this test case. Cardiovascular dynamics also affect the blood oxygen dependent (BOLD) signal in functional magnetic resonance imaging (fMRI). This Kalman filter framework for DOT may be adapted for BOLD fMRI analysis and multimodal studies.

Algorithms↗

Dynamic physiological modeling for functional diffuse optical tomography.

Diffuse optical tomography (DOT) is a noninvasive imaging technology that is sensitive to local concentration changes in oxy- and deoxyhemoglobin. When applied to functional neuroimaging, DOT measures hemodynamics in the scalp and brain that reflect competing metabolic demands and cardiovascular dynamics. The diffuse nature of near-infrared photon migration in tissue and the multitude of physiological systems that affect hemodynamics motivate the use of anatomical and physiological models to improve estimates of the functional hemodynamic response. In this paper, we present a linear state-space model for DOT analysis that models the physiological fluctuations present in the data with either static or dynamic estimation. We demonstrate the approach by using auxiliary measurements of blood pressure variability and heart rate variability as inputs to model the background physiology in DOT data. We evaluate the improvements accorded by modeling this physiology on ten human subjects with simulated functional hemodynamic responses added to the baseline physiology. Adding physiological modeling with a static estimator significantly improved estimates of the simulated functional response, and further significant improvements were achieved with a dynamic Kalman filter estimator (paired t tests, n=10, P<0.05). These results suggest that physiological modeling can improve DOT analysis. The further improvement with the Kalman filter encourages continued research into dynamic linear modeling of the physiology present in DOT. Cardiovascular dynamics also affect the blood-oxygen-dependent (BOLD) signal in functional magnetic resonance imaging (fMRI). This state-space approach to DOT analysis could be extended to BOLD fMRI analysis, multimodal studies and real-time analysis.

Blood Pressure↗

Improved quantification of small objects in near-infrared diffuse optical tomography.

Diffuse optical tomography allows quantification of hemoglobin, oxygen saturation, and water in tissue, and the fidelity in this quantification is dependent on the accuracy of optical properties determined during image reconstruction. In this study, a three-step algorithm is proposed and validated that uses the standard Newton minimization with Levenberg-Marquardt regularization as the first step. The second step is a modification to the existing algorithm using a two-parameter regularization to allow lower damping in a region of interest as compared to background. This second stage allows the recovery of the actual size of an inclusion. A region-based reconstruction is the final third step, which uses the estimated size and position information from step 2 to yield quantitatively accurate average values for the optical parameters. The algorithm is tested on simulated and experimental data and is found to be insensitive to object contrast and position. The percentage error between the true and the average recovered value for the absorption coefficient in test images is reduced from 47 to 27% for a 10-mm inclusion, from 38 to 13% for a 15-mm anomaly, and from 28 to 5.5% for a 20-mm heterogeneity. Simulated data with absorbing and scattering heterogeneities of 15 mm diam located in different positions show recovery with less than 15% error in absorption and 6% error in reduced scattering coefficients. The algorithm is successfully applied to clinical data from a subject with a breast abnormality to yield quantitatively increased absorption coefficients, which enhances the contrast to 3.8 compared to 1.23 previously.

Algorithms↗

Near-infrared diffuse optical tomography.

Diffuse optical tomography (DOT) is emerging as a viable new biomedical imaging modality. Using near-infrared (NIR) light, this technique probes absorption as well as scattering properties of biological tissues. First commercial instruments are now available that allow users to obtain cross-sectional and volumetric views of various body parts. Currently, the main applications are brain, breast, limb, joint, and fluorescence/bioluminescence imaging. Although the spatial resolution is limited when compared with other imaging modalities, such as magnetic resonance imaging (MRI) or X-ray computerized tomography (CT), DOT provides access to a variety of physiological parameters that otherwise are not accessible, including sub-second imaging of hemodynamics and other fast-changing processes. Furthermore, DOT can be realized in compact, portable instrumentation that allows for bedside monitoring at relatively low cost. In this paper, we present an overview of current state-of-the -art technology, including hardware and image-reconstruction algorithms, and focus on applications in brain and joint imaging. In addition, we present recent results of work on optical tomographic imaging in small animals.

Algorithms↗

Initial assessment of a simple system for frequency domain diffuse optical tomography.

Diffuse optical tomography is an imaging technique whereby spatial maps of absorption and scattering coefficients are derived from the characteristics of multiply scattered light transmitted through the object. The system described here used four intensity-modulated light sources and measurements of the intensity and phase (relative to each source) at 16 or 20 detectors on the surface of a 10 cm diameter cylinder. An iterative Newton-Raphson algorithm was used to estimate the absorption and scattering coefficients at each pixel in a 17 x 17 array minimizing the difference between measured and calculated values of the intensity and phase at the measurement sites. Forward calculations of the intensity and phase were based on a multigrid finite-difference solution of the frequency domain diffusion equation. Numerical simulations were used to examine the resolution, contrast, and accuracy of the reconstructions as well as the effects of measurement noise, systematic uncertainties in source-detector location, and accuracy of the initial estimates for the optical properties. Experimental tests also confirmed that the system could identify and locate both scattering and absorbing inhomogeneities in a tissue-simulating phantom.

Algorithms↗

Optode positional calibration in diffuse optical tomography.

Although diffuse optical tomography is a highly promising technique used to noninvasively image blood volume and oxygenation, the reconstructed data are sensitive to systemic difference between the forward model and the actual experimental conditions. In particular, small changes in optode location or in the optode-tissue coupling coefficient significantly degrade the quality of the reconstruction images. Accurate system calibration therefore is an essential part of any experimental protocol. We present a technique for simultaneously calibrating optode positions and reconstructing images that significantly improves image quality, as we demonstrate with simulations and phantom experiments.

Calibration↗

Spectrally resolved bioluminescence optical tomography.

Spectrally resolved bioluminescence optical tomography is an approach to recover images of luciferase activity within a volume using multiwavelength emission data from internal bioluminescence sources. The underlying problem of uniqueness associated with nonspectrally resolved intensity-based bioluminescence tomography is highlighted. Reconstructed images of bioluminescence are presented by using as input both simulated and real multiwavelength data from a tissue-simulating phantom. The location of the internal bioluminescence is obtained with 1 mm accuracy. Further, the amplitude of the reconstructed source is proportional to the actual bioluminescence intensity.

Imaging, Three-Dimensional↗

Stochastic explanation of speckle contrast detection in ultrasound-modulated optical tomography.

Ultrasound-modulated optical tomography is an imaging technique that detects ultrasonically tagged light in optically turbid media to obtain images with optical contrast and ultrasonic spatial resolution. A CCD-camera-based speckle contrast detection scheme has been introduced previously to detect modulated light emerging from the ultrasonic sample volume. Differences in speckle contrast were experimentally observed when ultrasound was applied compared to when it was not. In this paper we provide an analytic explanation for this phenomenon and connect speckle statistics with ultrasonic field parameters. The theory predicts that speckle contrast changes linearly with applied acoustic intensity. This prediction is experimentally validated for both 1 and ultrasound. Signal dependence on ultrasound frequency is discussed.

Gelatin↗

Noncontact optical tomography of turbid media.

Optical tomography of turbid media has so far been limited by systems that require fixed geometries or measurements employing fibers. We present a system that records noncontact optical measurements from diffuse media of arbitrary shapes and retrieves the three-dimensional surface information of the diffuse medium. We further present a novel method of combining this composite data set and obtain accurate fluorescence reconstructions. This approach offers significant experimental simplicity and yields high-information-content datasets. The performance of this novel tomographic approach is demonstrated with experimental reconstructions of phantoms.

Models, Theoretical↗

Imaging of spatiotemporal coincident states by DC optical tomography.

The utility of optical tomography as a practical imaging modality has, thus far, been limited by its intrinsically low spatial resolution and quantitative accuracy. Recently, we have argued that a broad range of physiological phenomena might be accurately studied by adopting this technology to investigate dynamic states (Schmitz et al., 2000; Barbour et al., 2000; Graber et al., 2000; Barbour et aL, 2001; and Barbour et aL, 1999). One such phenomenon holding considerable significance is the dynamics of the vasculature, which has been well characterized as being both spatially and temporally heterogeneous. In this paper, we have modeled such heterogeneity in the limiting case of spatiotemporal coincident behavior involving optical contrast features, in an effort to define the expected limits with which dynamic states can be characterized using two newly described reconstruction methods that evaluate normalized detector data: the normalized difference method (NDM) and the normalized constraint method (NCM). Influencing the design of these studies is the expectation that spatially coincident temporal variations in both the absorption and scattering properties of tissue can occur in vivo. We have also chosen to model dc illumination techniques, in recognition of their favorable performance and cost for practical systems. This choice was made with full knowledge of theoretical findings arguing that separation of the optical absorption and scattering coefficients under these conditions is not possible. Results obtained show that the NDM algorithm provides for good spatial resolution and excellent characterization of the temporal behavior of optical properties but is subject to interparameter crosstalk. The NCM algorithm, while also providing excellent characterization of temporal behavior, provides for improved spatial resolution, as well as for improved separation of absorption and scattering coefficients. A discussion is provided to reconcile these findings with theoretical expectations.

Algorithms↗

Focusing optics of a parallel beam CCD optical tomography apparatus for 3D radiation gel dosimetry.

Optical tomography of gel dosimeters is a promising and cost-effective avenue for quality control of radiotherapy treatments such as intensity-modulated radiotherapy (IMRT). Systems based on a laser coupled to a photodiode have so far shown the best results within the context of optical scanning of radiosensitive gels, but are very slow ( approximately 9 min per slice) and poorly suited to measurements that require many slices. Here, we describe a fast, three-dimensional (3D) optical computed tomography (optical-CT) apparatus, based on a broad, collimated beam, obtained from a high power LED and detected by a charged coupled detector (CCD). The main advantages of such a system are (i) an acquisition speed approximately two orders of magnitude higher than a laser-based system when 3D data are required, and (ii) a greater simplicity of design. This paper advances our previous work by introducing a new design of focusing optics, which take information from a suitably positioned focal plane and project an image onto the CCD. An analysis of the ray optics is presented, which explains the roles of telecentricity, focusing, acceptance angle and depth-of-field (DOF) in the formation of projections. A discussion of the approximation involved in measuring the line integrals required for filtered backprojection reconstruction is given. Experimental results demonstrate (i) the effect on projections of changing the position of the focal plane of the apparatus, (ii) how to measure the acceptance angle of the optics, and (iii) the ability of the new scanner to image both absorbing and scattering gel phantoms. The quality of reconstructed images is very promising and suggests that the new apparatus may be useful in a clinical setting for fast and accurate 3D dosimetry.

Equipment Design↗

Computational calibration method for optical tomography.

We propose a computational calibration method for optical tomography. The model of the calibration scheme is based on the rotation symmetry of source and detector positions in the measurement setup. The relative amplitude losses and phase shifts at the optic fibers are modeled by complex-valued coupling coefficients. The coupling coefficients can be estimated when optical tomography data from a homogeneous and isotropic object are given. Once these coupling coefficients have been estimated, any data measured with the same measurement setup can be corrected for the relative variation in the data due to source and detector losses. The final calibration of the data for the source and detector losses and the source calibration between the data and the forward model are obtained as part of the initial estimation for reconstruction. The calibration method was tested with simulations and measurements. The results show that the coupling coefficients of the sources and detectors can be estimated with good accuracy. Furthermore, the results show that the method can significantly improve the quality of reconstructed images.

Algorithms↗

Intense acoustic bursts as a signal-enhancement mechanism in ultrasound-modulated optical tomography.

Biophotonic imaging with ultrasound-modulated optical tomography (UOT) promises ultrasonically resolved imaging in biological tissues. A key challenge in this imaging technique is a low signal-to-noise ratio (SNR). We show significant UOT signal enhancement by using intense time-gated acoustic bursts. A CCD camera captured the speckle pattern from a laser-illuminated tissue phantom. Differences in speckle contrast were observed when ultrasonic bursts were applied, compared with when no ultrasound was applied. When CCD triggering was synchronized with burst initiation, acoustic-radiation-force-induced displacements were detected. To avoid mechanical contrast in UOT images, the CCD camera acquisition was delayed several milliseconds until transient effects of acoustic radiation force attenuated to a satisfactory level. The SNR of our system was sufficiently high to provide an image pixel per acoustic burst without signal averaging. Because of the substantially improved SNR, the use of intense acoustic bursts is a promising signal enhancement strategy for UOT.

Feasibility Studies↗

Symmetries, inversion formulas, and image reconstruction for optical tomography.

We consider the image reconstruction problem for optical tomography with diffuse light. The associated inverse scattering problem is analyzed by making use of particular symmetries of the scattering data. The effects of sampling and limited data are analyzed for several different experimental modalities, and computationally efficient reconstruction algorithms are obtained. These algorithms are suitable for the reconstruction of images from very large data sets.

Algorithms↗