Search PubMedSearch

SEARCH · Search PubMed

Results for “Tobacco Use Cessation Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

417 recordsLinked to original sources

Optimizing smoking cessation pharmacotherapy and counseling for adult primary care patients: a factorial randomized controlled trial.

BACKGROUND: Even with the most effective smoking cessation pharmacotherapies (i.e., varenicline or combination nicotine replacement [C-NRT]), the majority of people ultimately return to smoking. This research explored how to optimize the use of varenicline and C-NRT to promote smoking cessation. METHODS: Primary care patients participated in a 2x2x2x2 factorial experiment that evaluated 4 factors: 1) Medication Type (Varenicline vs. C-NRT [patch + mini-lozenge]), 2) Preparation (pre-quit) Medication (4 Weeks vs. Standard); 3) Medication Duration (Extended [24 weeks] vs. Standard [12 weeks]); and 4) Counseling Type (Cessation Counseling [4 sessions] vs. Referral Support [2 sessions focused on use of referral resources]). This study was discontinued prior to reaching the proposed sample size (N = 608) due to pandemic-related budgetary constraints. RESULTS: Participants (N = 496) were 55% women and 45.6% Black individuals. There were no statistically significant main effects of the 4 factors on abstinence at 12, 26 or 52 weeks. There was a 3-way interaction between Medication Type, Preparation Medication, and Counseling Type (p = 0.04) predicting the primary outcome of biochemically confirmed abstinence at 52 weeks; cessation counseling vs. referral support improved varenicline quit rates when 4 weeks versus 1 week of pre-quit medication was offered. For C-NRT, counseling type did not significantly improve quit rates regardless of the use of preparation medication. CONCLUSIONS: There was no robust evidence that enhanced pre-quit or extended duration of varenicline or C-NRT increased abstinence rates. More intensive counseling may support cessation for different pharmacotherapy regimens. Given the lack of consistent findings, this research should be viewed as exploratory to guide future research.

Humans

Effectiveness of tobacco cessation interventions delivered in clinical settings in South Asia: a systematic review and meta-analysis.

BACKGROUND: Despite the burden of tobacco use, access to cessation support in South Asia remains scarce. OBJECTIVE: This review evaluates the effectiveness of tobacco cessation interventions delivered in clinical settings in South Asia. METHODS: Five relevant databases were searched from inception to February 2025. Eligibility criteria included randomized and non-randomized studies evaluating behavioral, pharmacotherapy, and multicomponent interventions delivered in clinical settings in South Asia. Data on study setting and design, participant information, intervention, comparator, and outcomes were extracted. Meta-analyses using random-effect models were conducted where possible. Certainty of evidence was assessed using GRADE. RESULTS: Thirty-seven studies were included (22 randomized and 15 non-randomized). Interventions involved pharmacotherapy (n = 6; 16.2%), nicotine replacement therapy (n = 7; 18.9%), behavioral counseling (n = 12; 32.4%), or combined/multicomponent interventions (n = 12; 32.4%). Most studies were conducted in India (n = 26; 70.3%), followed by Pakistan (n = 6; 16.2%), Nepal (n = 3; 8.1%), and two studies (5.4%) were multi-country in India, Pakistan, and Bangladesh. Pooled analyses demonstrated higher quit rates among intervention versus control for continuous abstinence at 0-3 months (RR: 1.21, 95%CI: 1.06 to 1.37) and >3 months (RR: 1.68, 95%CI: 1.1.4 to 2.47), and for point abstinence at >3 months post-intervention (RR: 2.03, 95%CI:1.35 to 3.08). Heterogeneity was high for all analyses (I2 range: 94% to 97%). Combined behavioral and pharmacotherapy interventions were most effective (RR: 1.70, 95%CI: 0.98 to 2.92), although not statistically significant (p = 0.06). CONCLUSION: Tobacco cessation interventions delivered in clinical settings in South Asia are effective, particularly when combining behavioral support with pharmacotherapy. However, evidence is limited by methodological weaknesses.

Humans

Effect of flavored on!® nicotine pouch products on smoking behaviors: A sequential, multiple assignment, randomized controlled trial.

PURPOSE: To evaluate whether flavored versus unflavored nicotine pouch (NP) access affects cigarette reduction and smoke exposure among adults who smoke daily, and whether delayed flavor introduction affects these outcomes. METHODS: Adults who smoked ≥ 5 cigarettes/day (CPD) with interest in replacing cigarettes with NPs were enrolled in a remote, six-week, sequential multiple assignment randomized trial (n = 402 randomized; n = 400 analyzed). Participants were randomized to immediate access to seven NP flavors (Flavor), unflavored-only access for six weeks (Original), or unflavored-only for three weeks followed by flavor access (Delayed Flavor). Primary outcomes were ≥ 50% reduction in weekly mean expired-air carbon monoxide (CO) from baseline and mean CO at Week 6. Secondary outcomes included ≥ 50% CPD reduction, mean CPD, CO-verified 7-day abstinence, and incident smoke-free days. RESULTS: At Week 6, Flavor and Original did not differ in ≥ 50% CO reduction (14.3% vs 14.2%; IRR=1.0, 95% CI=0.6-1.8) or mean CO (18.3 vs 16.5 ppm; β=1.9, 95% CI=-1.3-5.0). CPD decreased across groups by Week 6, with no differences between Flavor and Original in ≥ 50% CPD reduction (50.3% vs 51.6%; IRR=1.0, 95% CI=0.8-1.2) or CO-verified abstinence (9.3% vs 8.9%; IRR=1.0, 95% CI=0.5-2.2). Flavor increased smoke-free days early, with attenuation over time. Among Week 3 non-responders, delayed flavor access increased ≥ 50% CPD reduction at Week 6 (33.3% vs 18.6%; IRR=1.8, 95% CI=1.0-3.2). CONCLUSIONS: NP access supported cigarette reduction regardless of flavor availability, but flavors may accelerate smoke-free days and improve response among individuals who do not reduce cigarette consumption with unflavored products alone.

Humans

Affective reactivity to a remote computer-based Trier Social Stress Test during a planned quit attempt: associations with short-term cigarette smoking lapse risk.

BACKGROUND: The Trier Social Stress Test (TSST) elicits affective responses and has been linked to smoking behavior. However, its remote use during a planned quit attempt-when stress reactivity may influence early lapse-remains understudied. OBJECTIVE: To quantify affective reactivity to a remotely administered TSST on a planned quit date following overnight abstinence and evaluate associations with cigarette use and lapse within 48 h. METHODS: This secondary analysis used data from a randomized controlled trial of adult smokers completing a remotely administered TSST following overnight nicotine abstinence. Urge, anxiety, and stress were assessed using visual analog scales and summarized using area under the curve (AUC) metrics. Smoking outcomes included cigarette count and lapse within 48 h. Associations were estimated using generalized estimating equations. RESULTS: In adjusted models, anxiety reactivity-but not urge or stress-was associated with cigarette count and lapse. Greater anxiety exposure (AUCtot) and change above baseline (AUCab) were associated with higher cigarette count (IRR=1.0004, 95%CI:1.0002-1.001, p=.002; IRR=1.01, 95%CI: 1.002-1.01, p=.002) and increased odds of lapse (OR=1.001, 95%CI: 1.0001-1.002, p=.03; OR=1.02, 95%CI: 1.001-1.03, p=.03). Effect sizes were small. CONCLUSIONS: Anxiety reactivity under nicotine deprivation was associated with increased cigarette use and lapse 48 h post quit attempt, suggesting individual differences in stress-evoked anxiety may serve as a behavioral marker for early lapse. Remote TSST administration appears feasible for eliciting affective responses on a quit date.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6 h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7 h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference - 7.6 h; p = 0.001) and required fewer FFP units (-2.6 units; p = 0.019), with no significant difference in all-cause mortality (RR 1.14; p = 0.490) or thrombotic events (RR 1.43; p = 0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Cannabis and cannabinoids for the treatment of mental and substance use disorders and symptoms: A systematic review and meta-analysis of experimental and observational studies.

BACKGROUND: Interest in cannabinoids for mental and substance use disorders is increasing. We examined experimental and observational evidence for treating these disorders and their symptoms. METHODS: Systematic review and meta-analysis (PROSPERO CRD42023467536). We searched CENTRAL, MEDLINE, Embase and PsycINFO to May 2025 for studies of cannabinoids in adults (≥18 years) with ADHD, anxiety, depression, PTSD, psychosis or Tourette syndrome, or alcohol, cannabis, opioid or tobacco use disorders. Two reviewers screened, extracted and assessed quality using a risk-of-bias tool and GRADE. RESULTS: We included 82 experimental and 118 observational studies. In RCTs, cannabinoids reduced anxiety symptoms (SMD=-0.40; 95% CI: -0.57, -0.23; I²=90%) and, in one small trial, PTSD symptoms (SMD=-2.60; 95% CI: -4.58, -0.62; n=20), with trivial-to-no effect on depression (SMD=-0.20; 95% CI: -0.43, 0.04; I²=91.6%), ADHD, psychosis and Tourette syndrome. Much anxiety and depression evidence came from symptoms measured as secondary outcomes in other primary conditions. Cannabinoids worsened cannabis use disorder severity in one RCT (SMD=2.35; 95% CI: 1.49, 3.21), with no effect on craving or withdrawal; evidence for alcohol, opioid and tobacco use disorders was very limited. Observational studies suggested improvements but had high risk of bias. The only significant safety finding was increased withdrawals due to adverse events with THC (OR=2.78; 95% CI: 1.66, 4.65). Certainty was predominantly very low. DISCUSSION: The evidence base shows very low certainty, high heterogeneity and methodological limitations, and is insufficient to support cannabinoids as first-line treatment. Signals for anxiety and PTSD are limited by indirectness and low certainty; no benefit was evident for depression; THC-related safety signals warrant careful consideration.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift™), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3 ± 13.2 years; mean AHI 22.9 ± 13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

Effectiveness and usability of artificial intelligence-powered assistive technologies in Supporting daily activities of children with cerebral palsy: a systematic review.

BACKGROUND: Cerebral Palsy (CP) is the main cause of motor disabilities in childhood, necessitating innovative approaches to rehabilitation and assistive technology (AT). Simultaneously, artificial intelligence (AI) is increasingly being integrated into devices to create more adaptive, personalized, and effective AT. This systematic review aimed to evaluate the effectiveness and usability of AI-powered assistive technologies designed to support daily activities and rehabilitation in children with CP. MATERIALS AND METHODS: Five databases, including Scopus, Web of Science, PubMed, Embase, and IEEE Xplore, were systematically searched, and 23 articles were included in the final analysis. Articles were identified, selected, and categorized into emerging thematic areas based on the primary function and application of the technology. RESULTS: Five key thematic topics were identified: 1) AI-driven motor rehabilitation and gait training for functional mobility; 2) intelligent assessment and monitoring systems for clinical decision support; 3) AI-supported communication, social interaction, and intention recognition tools; 4) gamified and virtual reality-based interventions to enhance engagement and usability; and 5) smart assistive systems supporting daily living and independent mobility. The findings demonstrate a strong trend toward the application of AI technologies in personalized, engaging, and data-driven interventions for children with CP. However, the field is predominantly in the proof-of-concept stage, with limitations including small sample sizes, lack of long-term clinical validation, challenges in user-centered design, and usability for children with CP. CONCLUSION: AI-powered assistive technologies hold significant potential for transforming the care of children with CP by enabling highly personalized and engaging interventions. To actualize this potential, future work must realize that practical application remains challenging owing to limited clinical validation, technological integration, and usability barriers for children with CP. Future research must prioritize user-centered design and multidisciplinary collaboration to ensure that AI and robotic advancements improve the usability and quality of life for children with CP.

Humans

Changes in sexual behavior among women in studies evaluating the dapivirine vaginal ring for HIV prevention.

BACKGROUND: Access to novel HIV prevention technologies often raise concerns of risk compensation. This analysis examined changes in the sexual behaviors of MTN 020/ASPIRE participants, a placebo controlled randomized control trial, who subsequently enrolled in MTN-025/HOPE, an open-label extension using the dapivirine vaginal ring. METHODS: Both studies enrolled healthy, sexually active, HIV-negative women from Malawi, South Africa, Uganda and Zimbabwe. Longitudinal data on participants' sexual behaviors, specifically sex with a nonprimary partner (past 3&#xa0;months), and use of male or female condoms at the last vaginal sex act were compared between ASPIRE and HOPE. Conditional and mixed ordinal logistic regression models evaluated associations between study and sexual behaviors at enrollment,&#xa0;and quarterly over the first 12&#xa0;months. RESULTS: Of the 2629 individuals enrolled in ASPIRE, 1456 (55%) participated in HOPE. At enrollment, the proportion of participants who reported sex with a nonprimary partner and condom use at last vaginal sex act did not differ by study. Across all quarterly follow-up visits, sex with a nonprimary partner was more common in HOPE (13.9-18.7%) than ASPIRE (10.7-12.6%); adjusted OR&#xa0;1.47, 95% CI 1.24-1.75, P&#xa0;<&#xa0;0.001. There was no difference in condom use at the last vaginal act across all quarterly follow-up visits between ASPIRE (36.5-42.7%) and HOPE (43.6-46.7%); adjusted OR&#xa0;1.05, 95% CI 0.94-1.18. CONCLUSION: More women reported sex with nonprimary partners in HOPE, with little change in condom use over time between the two studies. Understanding behavior changes during PrEP use allows for tailored, holistic reproductive health programming.

Humans

Effects of comprehensive oral care on nasogastric tube removal in long-term care residents with dysphagia: A multi-center randomized controlled trial.

Oral care is essential for residents in long-term care (LTC) facilities to reduce complications such as aspiration pneumonia. While routine oral hygiene is standard practice, comprehensive oral care (COC)-which includes facial and intraoral muscle massage, salivary gland stimulation, and oral moisturization-may further enhance swallowing function. However, evidence linking COC directly to nasogastric (NG) tube removal remains limited. This study evaluated the effectiveness of COC in facilitating NG tube removal and improving swallowing function among LTC residents with dysphagia. A multicenter, open-label randomized controlled trial was conducted across eight LTC facilities. The intervention group (n = 40) received daily one-on-one COC sessions lasting 30-40 min, while the control group (n = 37) received routine oral hygiene. Participants were followed for six months, with outcomes including NG tube removal, swallowing function, body weight, and pneumonia incidence. At six months, the COC group demonstrated a significantly higher NG tube removal rate, with eight participants achieving full oral intake (p = 0.005). Functional Oral Intake Scale scores were also significantly higher in the intervention group (p = 0.005). Time to NG tube removal ranged from 17 to 182 days. Under intention-to-treat principles, the NG tube removal rate remained significantly higher in the COC group (16.7%vs. 0%, p = 0.005). Competing risks analysis using the Aalen-Johansen estimator confirmed a 6-month cumulative incidence of NG tube removal of 14.6% in the COC group versus 0% in the control group (Gray's test: p = 0.005), with no significant between-group difference in mortality (p = 0.500). No significant differences were observed in body weight change or pneumonia incidence between groups. Among participants who successfully discontinued NG tube use, dementia was the most common underlying condition. These findings suggest that daily one-on-one COC is a feasible intervention in LTC settings and may improve swallowing function while facilitating NG tube removal in residents with dysphagia.

Humans

Oxygen-controlled gamma-irradiation and annealing enable terminal processing of collagen-based biomaterials.

Gamma irradiation is a widely adopted method for terminal sterilization of medical devices; however, its application to collagen-based extracellular matrix (ECM) materials remains limited due to radiation-induced degradation of structural integrity and mechanical performance. Here, we present an engineered terminal-processing strategy that combines oxygen controlled gamma irradiation (25-30&#xa0;kGy) with post-irradiation dry-heat annealing to preserve ECM functionality while achieving effective sterilization. By modulating oxygen availability during irradiation, this approach alters radical reaction pathways, suppresses oxygen-mediated oxidative degradation, and generates a metastable radical-containing intermediate, which is subsequently converted into a structurally stabilized collagen network through thermal annealing. As a result, the treated matrices preserved ECM integrity and recovered clinically relevant mechanical properties. Furthermore, the process achieved cumulative viral reductions exceeding 6 log10 across a representative panel including enveloped and non-enveloped DNA and RNA viruses, demonstrating compatibility with sterility assurance and viral safety requirements for biologically derived medical devices. Notably, preliminary observations indicate that mechanical integrity can be partially preserved even at elevated irradiation doses up to 50&#xa0;kGy, suggesting potential applicability to sterilization validation frameworks requiring higher assurance levels. Overall, this work establishes a mechanistically grounded terminal-processing paradigm that enables control of radical fate, decouples sterilization efficacy from material degradation, and integrates sterilization, viral safety, and functional preservation into a unified and scalable framework for collagen-based biomaterials. This concept repositions gamma-irradiation from a purely degradative process to a controllable tool for tuning collagen structure and performance.

Gamma Rays

The radiographic effect of cage subsidence on neuroforamina after anterior cervical discectomy and fusion.

STUDY DESIGN: Retrospective Cohort Study. OBJECTIVE: The objective of this study is to investigate the effect of cage subsidence on neuroforaminal area after anterior cervical discectomy and fusion (ACDF) utilizing computed tomography (CT). SUMMARY OF BACKGROUND DATA: Restoration of disc height via implantation of an interbody device provides an indirect decompression of the cervical neuroforamina. Interbody cage subsidence is a potential postoperative occurrence, but the effect of this on neuroforaminal area has yet to be characterized. METHODS: A retrospective review was conducted of patients who underwent one- to four-levels of ACDF utilizing an interbody device with anterior plating. Cage subsidence, neuroforaminal area, height and width were measured on CT scans preoperatively and at least 6&#xa0;months postoperatively. Levels with a cumulative sum of cranial and caudal subsidence greater than 4&#xa0;mm were classified as severely subsided, while levels with cumulative subsidence less than 4&#xa0;mm were classified as non-severely subsided. RESULTS: A total of 83 patients (151 levels) were included in this retrospective analysis. Average endplate subsidence was 3.2&#xa0;&#xb1;&#xa0;1.9&#xa0;mm. Non-severely subsided levels demonstrated a greater perioperative increase in neuroforaminal area (7.9 vs 2.1&#xa0;mm2, p&#xa0;<&#xa0;0.001), neuroforaminal height (1.1 vs 0.4&#xa0;mm, p&#xa0;<&#xa0;0.001) and neuroforaminal width (0.7 vs 0.1&#xa0;mm, p&#xa0;<&#xa0;0.001) compared to severely subsided levels. Interbody subsidence significantly predicted a decreased change in neuroforaminal height, width and area (p&#xa0;<&#xa0;0.001). Severe subsidence was associated with an increased rate of pseudarthrosis, but similar reoperation rates and recurrent neurologic deficits between the two groups. CONCLUSIONS: Severe subsidence of interbody cages after an ACDF was associated with a decreased perioperative change in neuroforaminal dimensions. This decrease in the size of the neuroforamen may reduce the effect of indirect decompression of the nerve root.

Humans

Comparative effectiveness of percutaneous coronary intervention strategies for coronary small-vessel disease: a network meta-analysis of randomized trials.

BACKGROUND: Coronary small-vessel disease (SVD) remains challenging for percutaneous coronary intervention (PCI) because small lumens magnify restenosis and ischemic risk. Multiple devices are available, yet their comparative performance is uncertain. This study evaluated and ranked PCI strategies for SVD. METHODS: A systematic review and network meta-analysis was conducted in accordance with PRISMA. PubMed, Embase, the Cochrane Central Register of Controlled Trials, Web of Science, and Google Scholar were searched from inception to 15 August 2025. Eligible studies were English-language randomized controlled trials enrolling adults with angiographic SVD defined as reference vessel diameter &#x2264;3.0&#x2009;mm, comparing PCI strategies, and reporting target lesion revascularization (TLR), binary restenosis (BR), or myocardial infarction (MI). A frequentist random-effects network meta-analysis generated odds ratios (ORs) with 95% confidence intervals (CIs) and treatment rankings using the surface under the cumulative ranking curve (SUCRA). RESULTS: Thirty-nine trials including 14,503 patients met the criteria. For TLR (37 studies; 11,980 patients), the highest SUCRA values were observed with sirolimus-eluting stents (SES 90.1%), zotarolimus-eluting stents (ZES 83.9%), and everolimus-eluting stents (EES 82.2%). For BR (32; 6,468), SES, ZES, and paclitaxel-coated balloons (DCB-PTX) ranked highest (95.0%, 80.0%, and 78.3%). For MI (37; 11,602), SES, DCB-PTX, and ZES ranked highest (79.0%, 78.7%, and 68.5%). Representative effects showed SES reduced TLR versus bare-metal stents (BMS) (OR, 0.25; 95% CI, 0.15-0.43) and MI versus BMS (OR, 0.41; 95% CI, 0.21-0.79). Conventional approaches such as BMS, plain old balloon angioplasty (POBA), and gold-plated balloon angioplasty (GPBA) ranked lowest across outcomes. CONCLUSION: SES provides the most consistent clinical benefit for coronary SVD. ZES, EES, and DCB-PTX are effective alternatives in selected settings, whereas BMS, POBA, and GPBA are less effective. These findings offer comparative evidence to guide device selection in SVD.

Humans

HPV Testing Versus Cytology for Cervical Cancer Screening&#xa0;Among Women 50&#x2009;Years and Older: Evidence From the HPV FOCAL Randomized Controlled Trial.

Evidence on the comparative effectiveness of HPV testing versus cytology specifically in women aged &#x2265;&#x2009;50&#x2009;years who are approaching screening cessation remains limited. This analysis included 6471 women aged &#x2265;&#x2009;50 at baseline screening in the HPV FOCAL randomized clinical trial. Women were randomly allocated to receive cytology (Control Group, n&#x2009;=&#x2009;3248, 50.19%) or HPV testing (Intervention Group, n&#x2009;=&#x2009;3223, 49.81%) at baseline, with co-testing at 48-month exit. We calculated incidence rates and risk ratios for CIN2+ detection over follow-up and compared missed lesions at exit by screening method. At the 48-month exit, CIN2+ detection was lower among HPV baseline-negative women than among those in the cytology group (1.61/1000 [95% CI, 0.52-3.76] vs. 3.15/1000 [95% CI, 1.51-5.78]; risk ratio, 0.51 [95% CI, 0.11-0.91]), reflecting higher baseline detection with HPV testing and fewer prevalent lesions at exit. Even with cytology re-screening at 2&#x2009;years, 50% of CIN2+ cases were missed compared to 30% with HPV testing. After adjusting for age, education, smoking status, and lifetime sexual partners, the hazard ratio for CIN2+ comparing HPV to cytology was 0.44 (95% CI, 0.22-0.88). Among women aged &#x2265;&#x2009;50&#x2009;years, HPV primary screening was more effective than cytology at detecting CIN2+ lesions and was associated with a continued lower subsequent risk following a negative HPV test, supporting its use in cervical cancer screening programs in this age cohort.

Aged

Relationships between cannabis and cocaine use in a randomized trial of combined buprenorphine and naltrexone for DSM-IV cocaine dependence.

BACKGROUND: Cannabis is the most commonly used drug in the United States, and among people who use cannabis, polysubstance use is common and understudied. We aimed to examine the association of tetrahydrocannabinol (THC) positive urine drug screen (+UDS) with the odds of submitting a cocaine&#xa0;+&#xa0;UDS during cocaine use disorder treatment. METHODS: We conducted a secondary data analysis of a previously reported double-blind, placebo-controlled clinical trial, CTN0048. Participants meeting criteria for opioid abuse/dependence were assigned to receive extended-release naltrexone and one of three conditions of buprenorphine (placebo, 4&#xa0;mg/day, 16&#xa0;mg/day) for 8&#xa0;weeks. Generalized estimating equations (GEE) were used to analyze urine samples (Liu et al., 2018) collected over time, examining the association between THC&#xa0;+&#xa0;UDS and cocaine&#xa0;+&#xa0;UDS during treatment. RESULTS: Participants (n&#xa0;=&#xa0;301) averaged 46 (SD&#xa0;=&#xa0;8.64) years of age, were majority male (78.41&#xa0;%), non-Hispanic (89.70&#xa0;%), and African American (66.45&#xa0;%). GEE results indicated that patients who submitted THC&#xa0;+&#xa0;UDS had significantly higher odds of submitting cocaine&#xa0;+&#xa0;UDS compared to participants who submitted THC-negative UDS across the 25 time points examined (OR&#xa0;=&#xa0;1.47, 95&#xa0;% CI&#xa0;=&#xa0;1.21-1.79, p&#xa0;=&#xa0;0.00). Time (OR&#xa0;=&#xa0;0.9998, 95&#xa0;% CI: 0.9997, 0.9999, p&#xa0;=&#xa0;0.018) and the covariate of sex assigned at birth (OR&#xa0;=&#xa0;1.77, 95&#xa0;% CI&#xa0;=&#xa0;1.13-2.77, p&#xa0;=&#xa0;0.013) were also significant in the model, indicating very small decreases in the odds of submitting a cocaine&#xa0;+&#xa0;UDS over time for all patients and 77&#xa0;% higher odds of submitting cocaine&#xa0;+&#xa0;UDS for females. CONCLUSION: THC&#xa0;+&#xa0;UDS was associated with increased odds of submitting a cocaine&#xa0;+&#xa0;UDS during treatment. Further investigation is needed to discern whether decreasing THC use will result in reduced cocaine use; however, these results suggest that it may be beneficial to counsel patients on cannabis use cessation both before and during treatment for cocaine use, as it is related to cocaine use treatment outcomes. TRIAL REGISTRATION: Secondary data analysis of ClinicalTrials.gov, TRN: NCT01402492 ("A randomized study to test the safety and effectiveness of buprenorphine in the presence of naltrexone for the treatment of cocaine dependence"; National Drug Abuse Treatment Clinical Trials Network (CTN) clinical trial: CTN0048), Registration date: 27 July 2011.

Humans

Implementing a novel digital health platform for self-management of postmenopausal osteoporosis: A qualitative study of user experiences, perspectives and implementation outcomes.

BACKGROUND: Osteoporosis self-management requires scalable support, and digital health platforms may meet this need. This study aimed to characterise the experiences and perspectives of postmenopausal women who participated in a 12-month randomised controlled trial (RCT) of a digital voice assistant (DVA) delivered osteoporosis self-management intervention, and to assess key implementation outcomes. METHODS: This was a qualitative analysis of interviews with postmenopausal women from the intervention arm (DVA group) of the RCT. The DVA program broadcast education videos, medication reminders, home-based exercise, nutrition advice and monthly quizzes through a DVA device. Semi-structured interviews were recorded, transcribed and managed in NVivo through reflexive thematic analysis, guided by the Practical Planning for Implementation and Scale-Up and Proctor's implementation outcome taxonomy frameworks. Evidence weighting summarised participant coverage and code density. RESULTS: Twenty-two of 25 (88%) DVA group participants completed semi-structured interviews. Thematic analysis identified seven themes mapped to Proctor's implementation outcomes. Evidence weighting indicated strong support for the intervention's appropriateness and acceptability, moderate support for its adoption, fidelity, feasibility and sustainability, and limited support for costs. Participants valued clear audiovisual guidance, conversation-based interactions with natural language, and flexible home-based access to self-management. CONCLUSION: Digital health platforms for osteoporosis self-management appear feasible, acceptable and sustainable among postmenopausal women. Findings indicate that these platforms are approaching readiness for evaluation in implementation-focused settings, contingent on streamlined content, reliable delivery modalities, accessible user support, clear privacy regulations and pragmatic pricing models.

Humans

Impact of kangaroo care on circadian rhythm, growth, physiological stability in premature infants, and cortisol and melatonin levels in maternal breast milk: A randomized controlled trial.

PURPOSE: This study aimed to examine the effects of regular kangaroo care (KC) on sleep-wake cycles, growth, physiological stability, and maternal breast milk cortisol and melatonin levels in premature infants. DESIGN: This study was a parallel group, single-blind, pre-test-post-test, randomised controlled trial (RCT). METHODS: This randomized controlled study was conducted in a neonatal intensive care unit (NICU) in T&#xfc;rkiye between September 2024 and September 2025 Thirty-six premature infants were randomized to intervention (n = 28) or control (n = 28). Infants in the intervention group received KC for three consecutive days, twice daily (10:00 a.m. and 10:00 p.m.) for 60 min per session. Data were collected using the Infant Information Form, Physiological Parameters Monitoring Chart, and Premature Infant Sleep-Wake Cycles Tracking Chart. Sleep-wake cycles were monitored using a Bispectral Index device. Breast milk cortisol and melatonin levels were measured at baseline and on day three using the competitive ELISA method. The study was registered at ClinicalTrials.gov (NCT06589349). RESULTS: Regular KC had a statistically significant effect on BIS values, heart rate, respiratory rate, oxygen saturation, and body temperature (p < 0.05). No statistically significant effects were observed on infant body weight or on maternal breast milk cortisol and melatonin levels (p > 0.05). CONCLUSION: The findings indicate that regular KC is associated with improved regulation of the sleep-wake cycle and enhanced physiological stability in premature infants. No significant changes were observed in maternal breast milk cortisol or melatonin levels following KC.

Humans