Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Tape Recordings”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

A device for recording automatic audio tape recording.

Adaptation of a commercially available timer for use as a means of operating an audio tape recorder several times during the day is described. Data on a mother's rates of commanding her children were collected via both physically present observer and recorder methods in order to compare the usefulness of the recordings with direct observation. There was a high positive relationship between observer-recorder command rates, with the observer rates being consistently higher, when data were collected via both methods simultaneously as well as at different points in time.

Journal Article↗

Effect of tape recording on perturbation measures.

Tape recorders have been shown to affect measures of voice perturbation. Few studies, however, have been conducted to quantitatively justify the use or exclusion of certain types of recorders in voice perturbation studies. This study used sinusoidal and triangular waves and synthesized vowels to compare perturbation measures extracted from directly digitized signals with those recorded and played back through various tape recorders, including 3 models of digital audio tape recorders, 2 models of analog audio cassette tape recorders, and 2 models of video tape recorders. Signal contamination for frequency perturbation values was found to be consistently minimal with digital recorders (percent jitter = 0.01%-0.02%), mildly increased with video recorders (0.05%-0.10%), moderately increased with a high-quality analog audio cassette tape recorder (0.15%), and most prominent with a low-quality analog audio cassette tape recorder (0.24%). Recorder effect on amplitude perturbation measures was lowest in digital recorders (percent shimmer = 0.09%-0.20%), mildly to moderately increased in video recorders and a high-quality analog audio cassette tape recorder (0.25%-0.45%), and most prominent in a low-quality analog audio cassette tape recorder (0.98%). The effect of cassette tape material, length of spooled tape, and duration of analysis were also tested and are discussed.

Humans↗

Validating the content of pediatric outpatient medical records by means of tape-recording doctor-patient encounters.

Information in 51 tape-recorded physician-patient encounters was compared with information written in the patients' medical records. Diagnoses, chief complaints, scheduled appointments, non-drug therapy, and diagnostic studies were uniformly well-recorded. Medication names were well-recorded but dosages were not. Characteristics of care such as levels of function, probable cause of illness, reason for follow-up, and compliance were recorded poorly. Patients were more likely to known about and understand their diagnosis, and names, dosage, and intended function of their medications when this information was written in the record than when it was not. These findings indicate a relationship between the quality of medical records and the effectiveness of care.

Child↗

Comparison between tape-recorded and amplitude-integrated EEG monitoring in sick newborn infants.

In 15 ill newborn infants a comparison between long-term multichannel and single-channel recordings of simultaneously tape-recorded (Medilog system) and amplitude-integrated EEG (Cerebral Function Monitor) was made. There was good agreement between the main type of background activity diagnosed with the tape-recorded and the amplitude-integrated EEG for all recordings. Two infants had repetitive subclinical and subtle seizure activity, lasting for several hours, which was detected by both techniques. Short, single seizures were diagnosed in the recordings of nine infants. When a single electrographic seizure appeared in an otherwise stable recording, it was identified by both the tape-recorded and the amplitude-integrated EEG. Very short (5-30 s) seizure patterns, which were diagnosed with the tape-recorded EEG, were not identified in the cerebral function monitor recordings. In the single-channel recordings of both the EEG and the cerebral function monitor there were, on some occasions, difficulties in distinguishing single seizures from interference due to external artefacts. In the multichannel recordings the diagnosis of seizure patterns was facilitated by comparison with the other channels. Both the Medilog EEG and the cerebral function monitor are feasible techniques for following cerebral electrical activity in sick neonates, although neither technique is specifically constructed for this purpose. For clinical use in the neonatal intensive care unit the advantage with the cerebral function monitor is the immediately available recording. The tape-recorded EEG offers possibilities of more channels and a higher reliability when diagnosing short subclinical seizures, however, only after offline analysis.

Electroencephalography↗

Long-term ECG in ambulatory clinical practice. Analysis and 2-year follow-up of 100 patients studied with a portable ECG tape recorder.

A portable tape recorder for long-term ECG monitoring is described. Its light weight (500 g) and small size (138 X 115 X 39 mm) make its usage in routine clinical practice a practical proposition. The most important application has been in the differential diagnosis of Adams--Strokes syndrome. The results from the first 100 patients with a 2-yr follow-up are presented. The importance of GCG recording during the patients' relevant subjective symptoms is stressed. The mean duration of recording was 2.8 days. In the 28 patients with histories which fitted the symptoms of Adams--Stokes syndrome this diagnosis was confirmed by an arrhythmia recorded simultaneously with the symptoms. In 36 other patients with a similar history the diagnosis was excluded becase of a normal ECG during subjective symptoms. Of the 28 patients with Adams--Stokes sydrome, bradyarrhthmia was the causal factor in 20 patients and these had a pacemaker implanted, whereas the remaining 8 patients had a tachyarrhythmia, which wa treated with antiarrhythmic drugs. The 2-yrs follow-up revealed an improvement and a disappearance of the Adams--Stokes attack in all the patients with an implanted pacemaker. In several of the 36 patients in whom Adams--Stokes syndrome could not be confirmed the syncopal attacks disappeared spontaneously. A large number of arrhythmias, including ventricular and supraventricular tachycardia, 2nd degree AV block and sinus bradycardia were observed during symptom-free intervals in these 36 patients. The introduction of long-term ECG recording routinely in patients with dizziness and syncope of unknown reason has resulted in an increase of the number of patients with a confirmed diagnosis of the Adams--Stokes syndrome, and it has contributed to an increase in the incidence of pacemaker implantation in Malmö from 130 per million inhabitants in 1971 to 220 in 1973, and 1974, respectively.

Adams-Stokes Syndrome↗

Recording electrophysiological data on video tape: a superior and less costly alternative to conventional tape recorders.

Electrical potentials recorded extracellularly from the sinus gland of the isopod, Oniscus asellus, were stored on video tape with the aid of a digital-audio (DA) processor and a video cassette recorder (VCR). The DA processor transforms the analog signal to digital pulses of equal amplitude and converts these pulses into a television signal for recording on video tape. In playback, the DA processor reconverts the pulses to an analog signal with negligible distortion. When viewed on the oscilloscope screen, electrical potentials reproduced by this method were indistinguishable from electrical potentials recorded 'live' from the sinus gland. However, electrical potentials recorded from the same sinus gland and reproduced by a conventional FM tape recorder were easily differentiated from the 'live' recording. The special effects inherent in the VCR (e.g. stop action, frame advance) also permitted detailed analysis of spontaneously occurring electrical potentials. Special effects were not possible with the FM tape recorder. The price, ease of operation and ability to produce extremely high quality recordings, makes the DA processor and VCR an exceptional system for storing electrophysiological data.

Animals↗