Pediatric interventional radiography equipment: safety considerations.

This paper discusses pediatric image quality and radiation dose considerations in state-of-the-art fluoroscopic imaging equipment. Although most fluoroscopes are capable of automatically providing good image quality on infants, toddlers, and small children, excessive radiation dose levels can result from design deficiencies of the imaging device or inappropriate configuration of the equipment's capabilities when imaging small body parts. Important design features and setup choices at installation and during the clinical use of the imaging device can improve image quality and reduce radiation exposure levels in pediatric patients. Pediatric radiologists and cardiologists, with the help of medical physicists, need to understand the issues involved in creating good image quality at reasonable pediatric patient doses. The control of radiographic technique factors by the generator of the imaging device must provide a large dynamic range of mAs values per exposure pulse during both fluoroscopy and image recording as a function of patient girth, which is the thickness of the patient in the posterior-anterior projection at the umbilicus (less than 10 cm to greater than 30 cm). The range of pulse widths must be limited to less than 10 ms in children to properly freeze patient motion. Variable rate pulsed fluoroscopy can be leveraged to reduce radiation dose to the patient and improve image quality. Three focal spots with nominal sizes of 0.3 mm to 1 mm are necessary on the pediatric unit. A second, lateral imaging plane might be necessary because of the child's limited tolerance of contrast medium. Spectral and spatial beam shaping can improve image quality while reducing the radiation dose. Finally, the level of entrance exposure to the image receptor of the fluoroscope as a function of operator choices, of added filter thickness, of selected pulse rate, of the selected field-of-view and of the patient girth all must be addressed at installation.

Child↗

[Selective salpingography and tubal interventional radiography].

The study involved 70 patients considered to be sterile and in whom hysterosalpingography showed no tubal passage. Selective catheterisation enabled opacification under pressure in more than 80 p. cent of cases, with perfect visualisation of the entire tubes and significant peritoneal passage. In the presence of obstructive stenosis, disobstruction-reacanalisation using a soft probe was attempted with success in more than one case out of two. Future perspectives of selective salpingography appear to be very large. This technique seems to have a large number of indications apart from transport problems: recanalisation, sterilisation, and tubal antibiotic sensitivity studies.

Evaluation Studies as Topic↗

Interventional radiography and mortality risks in U.S. radiologic technologists.

With the exponential increase in minimally invasive fluoroscopically guided interventional radiologic procedures, concern has increased about the health effects on staff and patients of radiation exposure from these procedures. There has been no systematic epidemiologic investigation to quantify serious disease risks or mortality. To quantify all-cause, circulatory system disease and cancer mortality risks in U.S. radiologic technologists who work with interventional radiographic procedures, we evaluated mortality risks in a nationwide cohort of 88,766 U.S. radiologic technologists (77% female) who completed a self-administered questionnaire during 1994-1998 and were followed through 31 December 2003. We obtained information on work experience, types of procedures (including fluoroscopically guided interventional procedures), and protective measures plus medical, family cancer history, lifestyle, and reproductive information. Cox proportional hazards regression models were used to compute relative risks (RRs) with 95% confidence intervals (CIs). Between completion of the questionnaire and the end of follow-up, there were 3,581 deaths, including 1,209 from malignancies and 979 from circulatory system diseases. Compared to radiologic technologists who never or rarely performed or assisted with fluoroscopically guided interventional procedures, all-cause mortality risks were not increased among those working on such procedures daily. Similarly, there was no increased risk of mortality resulting from all circulatory system diseases combined, all cancers combined, or female breast cancer among technologists who daily performed or assisted with fluoroscopically guided interventional procedures. Based on small numbers of deaths (n=151), there were non-significant excesses (40%-70%) in mortality from cerebrovascular disease among technologists ever working with these procedures. The absence of significantly elevated mortality risks in radiologic technologists reporting the highest frequency of interventional radiography procedures must be interpreted cautiously in light of the small number of deaths during the relatively short follow-up. The present study cannot rule out increased risks of cerebrovascular disease, specific cancers, and diseases with low case-fatality rates or a long latency period preceding death.

Adult↗

[Reduction of radiation exposure for patient and investigator in interventional radiography].

PURPOSE: In a retrospective analysis of vascular interventional procedures, relations between parameters of the examination and radiation exposure of patient and medical personnel are examined. MATERIAL AND METHOD: 1208 vascular interventional procedures are evaluated. Interventional procedures are divided into three groups: percutaneous transluminal angioplasty, implantation of a stent, thrombolysis. RESULTS: Mean values of the radiation dose of patient and radiology personnel are reported for these examinations. The mean value of the radiation dose of the physician was 7 microSv (maximum 24 microSv), that of the patient 1548 cGy.cm2 (maximum 8485 cGy.cm2). CONCLUSION: The quantity of X-rays to the patient may be lowered by using pulsed fluoroscopy and by reducing the number of radiographs. Reduction of the number of radiographs may be achieved by using the last-image hold and the road mapping mode. The operator's dose can be decreased by using additional radiation protection systems like a MAVIG-radiation protection wall. The radiation dose reduction was 61% for the physician and 17% for the patient.

Angiography↗

[Role of interventional radiography in the treatment of the hepato-pancreato-duodenal area, complicated by obstructive jaundice].

We assessed the role of interventional radiological procedures used in the treatment of patients with hepatopancreatobiliary cancer complicated by obstructive jaundice. Between 1990 and 2000, 71 patients underwent percutaneous transhepatic biliary drainage (PTBD): external drainage--18 (group A); external-internal drainage or stenting (group B), and external-internal drainage or stenting plus chemoinfusion or chemoembolization of the hepatic artery--15 (group C). Mean survival (M(SD) calculated for patients who died was 2.1(0.5 mo for group A; (pb,c(0.01), 7.9(6.7 mo (group B), and 16.6(14.8 mo for group C (NS with B). The actual one-year survival was 10, 25, and 45%, respectively. External-internal PTBD and stenting are safe effective palliative procedures for patients with malignant obstructive jaundice. Survival in patients with hepatopancreatobiliary cancer doubled after chemoinfusion or chemoembolization, without grave complications or lethality.

Adult↗

A low-cost system for digital image processing of moving images in real time: application to X-ray fluoroscopy.

A low-cost image processing system and two real-time digital image processing algorithms using parallel processing have been developed to provide automatic equalization of moving images at video frequencies. The algorithms differ in the processing time required and the characteristics of the final image. The system takes an entire image from the video sequence, digitizes it, automatically calculates its histogram and the lowest and highest useful grey levels, equalizes the histogram, and finally converts it to the analogue image. Methods were applied to X-ray fluoroscopy (angiography) images, which are usually saturated or of uniform intensity (low contrast), leading to information loss. An application of these methods is in interventional radiography, which requires images in real time.

Algorithms↗

[Application of interventional radiology for stenosis of vascular anastomosis in living-donor liver transplantation].

Stenosis of vascular anastomosis is a significant complication leading to graft loss after liver transplantation. For the diagnosis of portal vein stenosis, clinical signs of portal hypertension such as ascites and thrombocytopenia, stenosis and/or poststenotic dilatation on ultrasonography (US), and jet flow, rambling, or scarcity flow of the intrahepatic portal vein on Doppler US are useful. Three-dimensional computed tomography is used to confirm the indications for interventional radiography (IVR) to treat portal stenosis. For the diagnosis of hepatic vein stenosis, clinical signs such as ascites and slight jaundice, dilatation and stenosis on US, and reduced flow with a flat wave form of the intrahepatic portal vein on Doppler US are useful. The percutaneous transcaval approach is safer than the percutaneous transhepatic approach for patients with ascites. The requirement for multiple procedures could be a good indication for stent placement before patients develop liver cirrhosis. For hepatic artery stenosis, percutaneous intraluminal angioplasty and stenting are possible and good results have been reported recently. However, the long-term results must be evaluated in the future. IVR can be safely and successfully applied to the treatment of vascular complications using balloon dilatation and/or stent placement techniques before graft dysfunction becomes irreversible.

Constriction, Pathologic↗

Radiation dose and image quality in diagnostic radiology. Optimization of the dose-image quality relationship with clinical experience from scoliosis radiography, coronary intervention and a flat-panel digital detector.

UNLABELLED: X-rays are known to cause malignancies, skin damage and other side effects and they are thus potentially dangerous. Therefore, it is essential and in fact mandatory to reduce the radiation dose in diagnostic radiology as far as possible. This is also known as the ALARA (as low as reasonably achievable) principle. However, the dose is linked to image quality and the image quality may not be lowered so far that it jeopardizes the diagnostic outcome of a radiographic procedure. The process of reaching this balance between dose and image quality is called optimization. The aim of this thesis was to propose and evaluate methods for optimizing the radiation dose-image quality relationship in diagnostic radiography with a focus on clinical usefulness. The work was performed in three main parts. OPTIMIZATION OF SCOLIOSIS RADIOGRAPHY: In the first part, two recently developed methods for digital scoliosis radiography (digital exposure and pulse fluoroscopy) were evaluated and compared to the standard screen-film method. Radiation dose was measured as kerma area-product (KAP), entrance surface dose (ESD) and effective dose; image quality was assessed with a contrast-detail phantom and through visual grading analysis. Accuracy in angle measurements was also evaluated. The radiation dose for digital exposure was nearly twice as high as the screen-film method at a comparable image quality while the dose for pulsed fluoroscopy was very low but with a considerably lower image quality. The variability in angle measurements was sufficiently low for all methods. Then, the digital exposure protocol was optimized to a considerably lower dose with a slightly lower image quality compared to the baseline. FLAT-PANEL DETECTOR: In the second part, an amorphous-silicon direct digital flat-panel detector was evaluated using a contrast-detail phantom, measuring dose as entrance dose. The flat-panel detector yielded a superior image quality at a lower dose than both storage phosphor plates and screen-film. Equivalent image quality compared to storage phosphor plates was reached at about one-third of the dose. OPTIMIZATION OF PERCUTANEOUS CORONARY INTERVENTION (PCI): In the third part, influence of various settings on radiation dose and image quality in coronary catheterisation and PCI was investigated. Based on these findings, the dose rate for fluoroscopy was reduced to one-third. The dose reduction was evaluated in a clinical series of 154 PCI procedures before and 138 after the optimization. Through this optimization, the total KAP was significantly reduced to two-thirds of the original value. IN SUMMARY: This thesis indicates the possibility of dose reduction in diagnostic radiology through optimization of the radiographic process.

Coronary Angiography↗

[Pleural biopsies and pleural drainage: interventional radiology].

Interventional radiography performed for diagnostic and therapeutic purposes enables specific orientation of the diagnostic and/or therapeutic interention under radiographic guidance. This minimally invasive approach reduces intervention related morbidity. Mortality remains exceptional. Pleural biopsies and pleural drainage are two interventional procedures performed as routine practices in many centers.

Biopsy↗

Radiography of the lumbar spine in primary care patients with low back pain: randomised controlled trial.

OBJECTIVE: To test the hypothesis that radiography of the lumbar spine in patients with low back pain is not associated with improved clinical outcomes or satisfaction with care. DESIGN: Randomised unblinded controlled trial. SETTING: 73 general practices in Nottingham, north Nottinghamshire, southern Derbyshire, north Lincolnshire, and north Leicestershire. 52 practices recruited participants to the trial. SUBJECTS: 421 patients with low back pain of a median duration of 10 weeks. INTERVENTION: Radiography of the lumbar spine. MAIN OUTCOME MEASURES: Roland adaptation of the sickness impact profile, visual analogue scale for pain, health status, EuroQol, satisfaction with care, use of primary and secondary care services, and reporting of low back pain at three and nine months after randomisation. RESULTS: The intervention group were more likely to report low back pain at three months (relative risk 1.26, 95% confidence interval 1.00 to 1.60) and had a lower overall health status score and borderline higher Roland and pain scores. A higher proportion of participants consulted their doctor in the three months after radiography (1.62, 1.33 to 1.97). Satisfaction with care was greater in the group receiving radiography at nine but not three months after randomisation. Overall, 80% of participants in both groups at three and nine months would have radiography if the choice was available. An abnormal finding on radiography made no difference to the outcome, as measured by the Roland score. CONCLUSIONS: Radiography of the lumbar spine in primary care patients with low back pain of at least six weeks' duration is not associated with improved patient functioning, severity of pain, or overall health status but is associated with an increase in doctor workload. Guidelines on the management of low back pain in primary care should be consistent about not recommending radiography of the lumbar spine in patients with low back pain in the absence of indicators for serious spinal disease, even if it has persisted for at least six weeks. Patients receiving radiography are more satisfied with the care they received. The challenge for primary care is to increase satisfaction without recourse to radiography.

Adult↗

Comparison of scintigraphy and magnetic resonance imaging for stress injuries of bone.

OBJECTIVE: To compare findings of radiography, scintigraphy, and magnetic resonance imaging (MRI) in stress injuries of bone and evaluate changes of these findings with time correlated with clinical symptoms. DESIGN: Prospective study. SETTING: A primary care hospital outpatient orthopedic clinic. PATIENTS: All 31 patients with stress injuries of bone who visited our clinic from July 1996 to June 2000. INTERVENTION: Radiography, scintigraphy, MRI, and clinical examinations were performed on the same day or at least within 1 week of each other, and the findings were compared. If symptoms of stress injury of bone continued, these examinations were repeated at intervals of 2 months until symptoms disappeared. These radiologic findings were assessed by an independent radiologist who was blinded to the clinical symptoms of the patients. MAIN OUTCOME MEASURES: Correlation accuracy of MRI and scintigraphy findings with clinical symptoms. RESULTS: Even with negative initial radiographic findings, all initial scintigraphy and MRI indicated stress injury of bone. There were no patients with positive/negative examinations. Grade of scintigraphy and MRI were closely correlated, and these findings also correlated with the degree of clinical symptoms. Compared with scintigraphy, MRI showed more diagnostic information, such as fracture line and periosteal edema. Areas of increased activity in scintigraphy were consistent with the grades of MRI, especially high signal intensity areas of STIR (short tau inversion recovery) image. CONCLUSIONS: From these observations, MRI is less invasive, provides more information than scintigraphy, and is recommended for initial diagnosis and assessment stages of stress injury of bone.

Adolescent↗

How well can radiographers triage x ray films in accident and emergency departments?

OBJECTIVE: To assess the ability of radiographers to identify abnormal radiographs of patients attending accident and emergency departments. DESIGN: Prospective study over six weeks. SETTING: Teaching hospital casualty x ray department. PATIENTS: 3394 consecutive patients referred for radiography. INTERVENTIONS: Radiographs were assessed by radiographers who were offered a four point triage scheme: normal, abnormal, insignificantly abnormal, or further advice required. MAIN OUTCOME MEASURES: Comparison of radiographers' assessments with an assessment made independently by the reporting radiologists. RESULTS: Overall disagreement between the radiographers and radiologists was 9.4%. There were 7% false positives and 14% false negatives. Most errors occurred in assessing radiographs of the skull, facial bones, chest, abdomen, and soft tissues. CONCLUSION: Unselected radiographers can offer useful advice on radiographs to casualty officers, but their high rate of false positive diagnoses indicates that they cannot triage casualty radiographs sufficiently accurately to allow them to extend their current reporting role.

Clinical Competence↗

Chest radiography in children aged 2-59 months diagnosed with non-severe pneumonia as defined by World Health Organization: descriptive multicentre study in Pakistan.

OBJECTIVES: To evaluate the chest radiographs of children diagnosed with non-severe pneumonia on the basis of the current World Health Organization guidelines (fast breathing alone) for radiological evidence of pneumonia. DESIGN: Descriptive analysis. SETTING: Outpatient departments of six hospitals in four cities in Pakistan. PARTICIPANTS: 2000 children with non-severe pneumonia were enrolled; 1932 children were selected for chest radiography. INTERVENTIONS: Two consultant radiologists used standardised WHO definitions to evaluate chest radiographs; no clinical information was made available to them. If they disagreed, the radiographs were read by a third radiologist; the final classification was based on agreement between two of the three radiologists. MAIN OUTCOME MEASURES: Presence or absence of pneumonia on radiographs. RESULTS: Chest radiographs were reported normal in 1519 children (82%). Radiological evidence of pneumonia was reported in only 263 (14%) children, most of whom had interstitial pneumonitis. Lobar consolidation was present in only 26 children. The duration of illness did not correlate significantly with the presence of radiological changes (relative risk 1.17, 95% confidence interval 0.91 to 1.49). CONCLUSION: Most children diagnosed with non-severe pneumonia on the basis of the current WHO definition had normal chest radiographs.

Bronchiolitis↗

Over-the-wire placement of large bore thoracostomy tubes.

A simple method is described for placement of large caliber thoracostomy tubes utilizing an over-the-wire (Seldinger) technique. The method employs an angioplasty balloon catheter on which a renal fascial dilator and sheath are mounted. Through the sheath a large caliber thoracostomy tube is placed into the pleural space.

Humans↗

Laser ablation of lung metastases: results according to diameter and location.

Lung tumour ablation with a thin-calibre laser applicator system was evaluated. We quantified feasibility, technical success and complication rates in relation to lesion diameter and location. Forty-two patients with 64 lung tumours were treated (39 patients with metastases and three with primary tumours). Mean follow-up was 7.6 months (range 6 weeks to 39 months). Eighty-six percent of treatments were technically successful in the first session. Pneumothorax was the main complication and occurred in 50% of the first 20 patients and in 35% of the rest. Two patients required a chest tube. Fourteen lesions were central and 50 were peripheral. It took several weeks for the effect of the therapy to become apparent on follow-up CT. Thirty-nine percent of all lesions increased in size immediately after treatment. Gross reduction in size with scar formation was seen in 50% of the lesions and cavitation in 13%. Local tumour control was achieved in 51 lesions. Progression after therapy was seen in 9% of lesions <1.5 cm but in more than 11% of larger lesions. Progression was also more frequent in lesions located in the basal parts of the lung (47%). Sixteen patients died due to systemic progression. Our results suggest that successful laser ablation of lung lesions is possible with a miniaturized applicator.

Adult↗

Complications of central venous catheters diagnosed by computed tomography.

Numerous reports of complications of central venous catheters have appeared in the literature. Most often these complications are diagnosed by plain or interventional radiography. Two cases are reported in which computed tomography was instrumental in diagnosing an abnormality that was not obvious on conventional radiography. This report demonstrates the value of this noninvasive technique for rapid and accurate evaluation.

Catheters, Indwelling↗

The utility of the frontal chest radiograph in the evaluation of chest drain placement.

AIM: To define the utility of the frontal chest radiograph in the assessment of chest drain position. PATIENTS AND METHODS: Fifty-six frontal chest radiographs in 45 patients with 61 chest drains (18 anterior, 9 interlobar, and 34 posterior position) were reviewed retrospectively to determine radiographic characteristics. RESULTS: Eighty-nine percent of the anterior drains demonstrated a curved appearance at the insertion site, while 50% of posterior drains and all interlobar drains were straight at the insertion site. A curved intrapleural drain was a common finding when positioned anteriorly and posteriorly (67% and 59%, respectively). Interlobar drains were often straight throughout their course (89%). The tips of interlobar drains were usually positioned at the hilum (89%). CONCLUSION: Results suggest that interlobar positioning can be suspected on the frontal chest radiograph. A curving chest drain with straight appearance at the insertion site was indicative of a posterior location.

Adult↗