Computerized evaluation of mammographic image quality using phantom images.

A simple, quick and computerized method for quantitatively evaluating the image quality of mammography phantom images has been developed. Images of the American College of Radiology (ACR) mammographic accreditation phantoms were acquired under different X-ray techniques, scored and ranked subjectively by five expert readers, and digitized for quantitative analysis. The contrast and signal-to-noise (contrast-to-noise) ratios of the main nodule and microcalcification group were obtained accurately and reproducibly using an image processing protocol. The contrast values were successful at discriminating differences in image quality due to variations in scatter conditions (as a result of different kVp's, and the presence or absence of an acrylic scatterer and/or a moving Bucky grid). They were more precise, reproducible and sensitive than the ACR score. In particular, the contrast of the main nodule was highly correlated (r(s) = 0.988: p<0.001) with the ranking of image quality by our panel of expert readers.

Artifacts↗

A comparative study of computer assisted assessment of image quality index for mammographic phantom images.

Mammographic phantom images are usually used to study the quality of images obtained by dedicated mammographic equipment. The digital image treatment techniques allow us to carry out an automatic analysis of the phantom image. In this work, some techniques of digital image processing are applied to compute a specific image quality index (IQI) for a mammographic phantom, namely CIRS model 11A version SP01. The algorithm designed analyses the phantom image by means of automatic detection of the number of microcalcifications, and the image resolution as the number of line pairs per millimetre. Then, the IQI is calculated from a scoring system. The manner in which the functioning conditions (kV and mAs) of the mammographic equipment and the preprocessing denoising method of the digital image affect the results for the IQI are also studied.

Algorithms↗

The effect of the antiscatter grid on full-field digital mammography phantom images.

Computer Analysis of Mammography Phantom Images (CAMPI) is a method for making quantitative measurements of image quality. This article reports on a recent application of this method to a prototype full-field digital mammography (FFDM) machine. Images of a modified ACR phantom were acquired on the General Electric Diagnostic Molybdenum Rhodium (GE-DMR) FFDM machine at a number of x-ray techniques, both with and without the scatter reduction grid. The techniques were chosen so that one had sets of grid and non-grid images with matched doses (200 mrads) and matched gray-scale values (1500). A third set was acquired at constant 26 kVp and varying mAs for both grid conditions. Analyses of the images yielded signal-to-noise-ratio (SNR), contrast and noise corresponding to each target object, and a non-uniformity measure. The results showed that under conditions of equal gray-scale value the grid images were markedly superior, albeit at higher doses than the non-grid images. Under constant dose conditions, the non-grid images were slightly superior in SNR (7%) but markedly less uniform (60%). Overall, the grid images had substantially greater contrast and superior image uniformity. These conclusions applied to the whole kVp range studied for the Mo-Mo target filter combination and 4 cm of breast equivalent material of average composition. These results suggest that use of the non-grid technique in digital mammography with the GE-DMR-FFDM unit, is presently not warranted. With improved uniformity correction procedure, this conclusion would change and one should be able to realize a 14% reduction in patient dose at the same SNR by using a non-grid technique.

Artifacts↗

Quantitative versus subjective evaluation of mammography accreditation phantom images.

The precision of quantitative and subjective evaluations of phantom image quality has been studied. Twenty-seven images of the American College of Radiology (ACR) mammography accreditation phantom were acquired under different x-ray techniques and digitized. Several quantitative image quality measures were obtained from each image by analyzing microcalcification and nodule target objects in the phantom. All images were also scored subjectively by 8 observers, each of whom provided a count of the number of objects seen in each target class (fibrils, microcalcifications, and nodules). An analysis was performed to predict the subjective measurements from the quantitative measurements and to estimate their variabilities. It was found that the subjective measures could be well predicted by the quantitative measures and that the variance of the quantitative measures was significantly smaller than that of the subjective measure, by almost a factor of 10. The implication for the ACR accreditation program for mammography is that a substantial improvement is possible in the image quality evaluation process by performing computerized analysis of the phantom images in addition to subjective analysis.

Accreditation↗

Image quality assessment via segmentation of breast lesion in X-ray and ultrasound phantom images from Fischer's full field digital mammography and ultrasound (FFDMUS) system.

Fischer has been developing a fused full-field digital mammography and ultrasound (FFDMUS) system funded by the National Institute of Health (NIH). In FFDMUS, two sets of acquisitions are performed: 2-D X-ray and 3-D ultrasound. The segmentation of acquired lesions in phantom images is important: (i) to assess the image quality of X-ray and ultrasound images; (ii) to register multi-modality images; and (iii) to establish an automatic lesion detection methodology to assist the radiologist. In this paper we developed lesion segmentation strategies for ultrasound and X-ray images acquired using FFDMUS. For ultrasound lesion segmentation, a signal-to-noise (SNR)-based method was adapted. For X-ray segmentation, we used gradient vector flow (GVF)-based deformable model. The performance of these segmentation algorithms was evaluated. We also performed partial volume correction (PVC) analysis on the segmentation of ultrasound images. For X-ray lesion segmentation, we also studied the effect of PDE smoothing on GVF's ability to segment the lesion. We conclude that ultrasound image qualities from FFDMUS and Hand-Held ultrasound (HHUS) are comparable. The mean percentage error with PVC was 4.56% (4.31%) and 6.63% (5.89%) for 5 mm lesion and 3 mm lesion respectively. The mean average error from the segmented X-ray images with PDE yielded an average error of 9.61%. We also tested our program on synthetic datasets. The system was developed for Linux workstation using C/C++.

Breast Neoplasms↗

Subjective evaluations of mammographic accreditation phantom images by three observer groups.

RATIONALE AND OBJECTIVES: Mammography providers are under increasing pressure to become certified by the American College of Radiology (ACR). Successful accreditation is contingent on passing a phantom image quality test. This study was undertaken to evaluate viewer performance with the phantom image evaluation process and to determine any observer group differences. METHODS: A series of standard phantom images were viewed by 30 medical physicists, 30 diagnostic radiologists, and 30 inexperienced observers. From the responses, object detection rates and passing rates according to the ACR criteria were established. These responses were analyzed with standard nonparametric tests to assess the degree of variability, correlation, and agreement among different observer groups. RESULTS: Median passing scores were similar for the radiologists and untrained readers, but the medical physicists appear to differ from the other two groups. There was not sufficient evidence to indicate that special training among physicists made a significant difference in median passing scores or mass detection rates. However, such training appeared to significantly affect the detection of microcalcification and fibril test patterns among the physicists' subgroups. Agreement among observer groups was high for all groups, but tended to be lower for overall passing rates than for any of the individual test objects. Agreement among physicists was affected by their subspecialty, presumably caused by their levels of specific training for these visual tasks. CONCLUSIONS: The authors conclude that choosing medical physicists to evaluate mammographic phantom films appears to be a good choice among potential observer groups, and that special training for reading these images affects their detection abilities and consistency. However, because passing rates did not appear to be affected by special training and given the current rapid degree of change in this area, more testing of medical physicists is desirable to examine these effects over time, and to study the effect of developing standards for training.

Accreditation↗

Retrocardiac phantom image on hypocycloidal chest tomograms.

A phantom image produced by displaced blur margins of the cardiac silhouette and mimicking a paraspinous retrocardiac mass was noted in 50% of 125 hypocycloidal full chest tomograms. It was reproduced on tomograms of a chest phantom. Careful comparison with routine posteroanterior and lateral chest radiographs prevents misinterpretation.

False Positive Reactions↗

Automated analysis of the American College of Radiology mammographic accreditation phantom images.

A significant metric in federal mammography quality standards is the phantom image quality assessment. The present work seeks to demonstrate that automated image analyses for American College of Radiology (ACR) mammographic accreditation phantom (MAP) images may be performed by a computer with objectivity, once a human acceptance level has been established. Twelve MAP images were generated with different x-ray techniques and digitized. Nineteen medical physicists in diagnostic roles (five of which were specially trained in mammography) viewed the original film images under similar conditions and provided individual scores for each test object (fibrils, microcalcifications, and nodules). Fourier domain template matching, used for low-level processing, combined with derivative filters, for intermediate-level processing, provided translation and rotation-independent localization of the test objects in the MAP images. The visibility classification decision was modeled by a Bayesian classifer using threshold contrast. The 50% visibility contrast threshold established by the trained observers' responses were: fibrils 1.010, microcalcifications 1.156, and nodules 1.016. Using these values as an estimate of human observer performance and given the automated localization of test objects, six images were graded with the computer algorithm. In all but one instance, the algorithm scored the images the same as the diagnostic physicists. In the case where it did not, the margin of disagreement was 10% due to the fact that the human scoring did not allow for half-visible fibrils (agreement occurred for the other test objects). The implication from this is that an operator-independent, machine-based scoring of MAP images is feasible and could be used as a tool to help eliminate the effect of observer variability within the current system, given proper, consistent digitization is performed.

Accreditation↗

Intra- and interobserver agreement and performance score of breast phantom image interpretation: influence of ambient room lighting levels.

The influence of ambient room lighting conditions on soft-copy breast phantom image interpretation was evaluated by comparing cathode ray tube (CRT) monitors with liquid crystal displays (LCDs). Nine observers were asked to use a three-point scale to rate the visibility of various phantom objects (masses, specks, and fibers) displayed on a 21-inch CRT (2,560 x 2,048) and a 21-inch LCD (2,560 x 2,048) under three different levels of ambient lighting (20, 100 and 420 lux at the display center). Each phantom image was interpreted twice, and the reproducibility of judgment and inter-observer agreement was evaluated using kappa statistics. Except for the "mass" score, the LCD score showed a significantly higher value (p<0.05) compared with that of CRT. Nevertheless, no significant differences were found among the three lighting levels. Furthermore, intra- and inter-observer agreement in judgments showed no effects of room illumination. Although the breast phantom objects were better visualized on LCDs than on CRT monitors, room illumination did not affect the performance score of soft-copy reading.

Breast Neoplasms↗

Nonlinear filters applied on computerized axial tomography: theory and phantom images.

New nonlinear image processing techniques, in particular smoothing based on the understanding of the image, may create computerized tomography (CT) images of good quality using less radiation. Such techniques may be applied before the reconstruction and particularly after it. Current CT scanners use strong linear low-pass filters applied to the CT projections, reducing noise but also deteriorating the resolution of the image. The method in this study was to apply a weak low-pass filter on the projections, to perform the reconstruction, and only then to apply a nonlinear filter on the image. Various kinds of nonlinear filters were investigated based on the fact that the image is approximately piecewise constant. The filters were applied with many values of several parameters and the effects on the spatial resolution and the noise reduction were evaluated. The signal-to-noise ratio of a high-contrast phantom image processed were compared with the nonlinear filter, with the SNR of the phantom images obtained with the built-in CT linear filters in two scanning modes, the normal and the ultra high resolution modes. It was found that the nonlinear filters improve the SNR of the image, compared to the built-in filters, about three times for the normal mode and twice for the UHR scanning mode. The most successful filter on low-contrast phantom image was applied and it also seems to lead to promising results. These results seem to show that applying nonlinear filters on CT images might lead to better image quality than using the current linear filters.(ABSTRACT TRUNCATED AT 250 WORDS)

Humans↗

Computer analysis of mammography phantom images (CAMPI): an application to the measurement of microcalcification image quality of directly acquired digital images.

The purpose of this investigation was to apply the recently developed CAMPI (computer analysis of mammography phantom images) method to a Fischer Mammotest Stereotactic Digital Biopsy machine. Another aim was to further elucidate the nature of the empirically introduced CAMPI measures. Images of an American College of Radiology (ACR) accreditation phantom centered on the largest two speck groups were obtained on this machine under a variety of x-ray conditions. An additional measure, alternative SNR (ASNR) is introduced which is complementary to the SNR measure. Analyses of the Mammotest images revealed that the mAs and kVp dependencies of the CAMPI measures could be understood from basic imaging physics principles. It is shown that: (1) the measures reflect the expected linearity of the digital detector and Poisson photon statistics; (2) under automatic exposure control (AEC) conditions the signal (SIG) measure is proportional to subject contrast; and (3) under AEC conditions the noise (NOI) measure is proportional to the square root of the average absorbed photon energy. Correspondence with basic imaging physics principles shows that the measures are significantly free of artifacts. Precision of the CAMPI measures exceeds that of human observers by orders of magnitude. CAMPI measures are expected to be more relevant to clinical mammography than Fourier metrics as the measurements are done on objects of arbitrary shape and size that were designed by the manufacturer to resemble various detection tasks in mammography. It is concluded that CAMPI can perform objective and highly precise evaluations of phantom image quality in mammography. It could be used as a sophisticated quality control tool, as a replacement for the current ACR/MQSA phantom evaluation program, and to evaluate the rapidly evolving digital mammography technology.

Biophysical Phenomena↗

Increasing the utility of the mammographic phantom image.

To increase the utility of the monthly accreditation mammographic phantom image, the authors added a light sensitometric strip on the same film. The optical densities of the steps on the sensitometric strip with values nearest those of the phantom background and disk were measured, and these optical densities and the density difference were recorded and plotted on a control chart. The ability was increased to determine if changes in the contrast or optical density on an image were due to film and associated processing or to the x-ray source.

Mammography↗

In-phantom imaging of all dose components in boron neutron capture therapy by means of gel dosimeters.

The experimental method for in-phantom imaging and profiling the absorbed dose in neutron capture therapy has been improved. The method separates the contributions of the various secondary radiation components and is based on suitably designed gel dosimeters in the form of layers. The discrimination of the dose components is achieved by means of pixel-to-pixel manipulations of images obtained with gel dosimeters having different isotopic composition. Large dose images are obtainable with this method, because the layer geometry of dosimeters avoids sensible variation of neutron transport due to the isotopic composition of gel. Operation modalities aimed at attaining more reliable results have been studied. Some results, together with the results of punctual measurements performed with conventional dosimeters and with MC calculations, are here reported.

Boron Neutron Capture Therapy↗

Comparison of contrast detail curves of full field digital with screen film breast phantom images.

In this investigation, we imaged a standard breast phantom and compared the contrast detail curves from a prototype full breast digital mammography system with the corresponding curves for a conventional, analog screen-film system. The full breast digital system exhibited superior contrast detail detectability. The results from this study will be used to plan future clinical evaluations comparing full breast digital and screen film mammography.

Breast Neoplasms↗

[Selection of parameters for multi-objective frequency processing in CR mammography: visual evaluation of mammographic phantom images].

The multi-objective frequency processing installed in the FCR5000R (Fuji Film Medical) is superior to the conventional processing used in the FCR9000 (Fuji Film Medical) in evaluating frequency processing. A suitable combination of parameters for multi-frequency-processing in computed radiography (CR) mammography was evaluated. The paired-comparison method using phantom images was performed for the visual evaluation. Results showed that the evaluation score of mass and fiber lesions depended on the multi-frequency balance type (MRB) parameter, and the low-frequency-cycle emphasizing parameter had the highest score. In contrast, the score of microcalcifications depended on the degree of multi-frequency enhancement (MRE). The most suitable parameters for the multi-frequency processing of every size and type of breast lesion were not obtained. However, MRB=A, MRT=p, and MRE=1.0 can be recommend for CR mammography.

Humans↗

Effects of nonionic intravenous contrast agents at PET/CT imaging: phantom and canine studies.

PURPOSE: To investigate the effects of intravenous contrast agents on quantitative values obtained with a combined positron emission tomographic (PET) and computed tomographic (CT) scanner by using several phantoms and a dog. MATERIALS AND METHODS: Fluorine 18 fluorodeoxyglucose (FDG) was mixed with different concentrations of contrast agent with the same syringe (phantom 1), and the phantom was scanned. After image reconstruction with various attenuation maps, radioactivity concentrations were compared. Then, FDG solutions with (phantom 2) or surrounded by (phantom 3) various concentrations of contrast agent were scanned repeatedly, and radioactivity concentration was compared. Finally, PET and CT with and without contrast agent were performed in a dog. PET images were reconstructed by using different attenuation maps, and radioactivity concentrations were compared. The radioactivity concentration on germanium 68 (68Ge)-based corrected images was regarded as standard, and percentage bias, defined as difference divided by measured activity of 68Ge-based corrected images, was assessed. The relationship between the concentration of contrast agent and the percentage bias was assessed with the Pearson coefficient r, and the significance of correlations was evaluated with the Fisher z test. RESULTS: All phantom studies demonstrated that presence of a contrast agent resulted in overestimation of emission data. CT numbers showed a strong positive correlation with the percentage bias in phantoms 2 (r = 0.999) and 3 (r = 0.987); the maximum percentage bias at 1,360 HU reached approximately 45%. These effects were independent of FDG concentration. In a canine model, presence of a contrast agent also increased emission activity, but the percentage bias was less than 15% in the liver and smaller in all other organs except the kidney (26%). CONCLUSION: High concentrations of a contrast agent caused considerable overestimation of apparent tracer activity in phantom studies; however, the emission bias was relatively modest in vivo, except in areas with very high contrast agent concentrations.

Animals↗

Review of the first 50 cases completed by the RACR mammography QA programme: phantom image quality, processor control and dose considerations.

The Mammography Quality Assurance Programme, recently established by the Royal Australasian College of Radiologists, has processed the first 50 applications. This programme, which closely follows the programme of the American College of Radiology (ACR), utilizes phantom film images, thermoluminescent dosimetry measurement of mean glandular dose, processor control charts, clinical images, equipment reports and required survey information to establish that a centre conforms to a minimum standard in mammography. The present paper describes the initial results of the first phantom images, dose measurements, processor control and survey information. A film review panel of six members has been trained in phantom film reading. Their evaluation of phantom films was compared with film readings by members of the ACR and was found to be in close agreement. Fifty films have been evaluated up to the present time with a failure rate of 26%. The major causes of failure were unacceptable film artefacts and poor contrast (as indicated by reduced fibre and mass visibility). A surprising result was the high failure in processing, where 23% of units reviewed had significant problems, including failure to keep the processor within required control limits. Only one centre recorded a mean glandular dose above 2 mGy with no centre over the 3 mGy limit. A review of the frequency of the quality control testing shows that the acceptance of quality assurance in mammography, while greater than in the initial stages of the ACR programme, is less than current US practice. These initial results for the accreditation process probably reflect an initial period of adjustment, as seen by the high pass rate achieved by centres that have resubmitted material to gain accreditation.

Accreditation↗

BaSO4-loaded agarose: a construction material for multimodality imaging phantoms.

RATIONALE AND OBJECTIVES: Phantom studies are an important part of the evaluation of imaging techniques; however, presently available phantom construction materials are not adequate for studies involving both magnetic resonance (MR) imaging and computed tomography (CT). The purpose of this study was to design a phantom construction material useful for multimodality imaging experiments. MATERIALS AND METHODS: Iodinated contrast agent or BaSO4 was added during the formation of agarose gels. Both CT and MR imaging were performed, and T1 and T2 values and CT numbers (in Hounsfield units) were obtained for multiple combinations of contrast material and agarose. Results. The T2 values of agarose gels span the range of those values found in biologic tissues. Phantoms containing iodinated contrast agent were not stable; contrast agent diffused across concentration gradients. BaSO4-loaded agarose phantoms were stable, however, and varying barium concentrations produced phantoms that spanned the range of CT numbers found in biologic tissues. Addition of BaSO4 did not substantially alter T1 or T2 values of agarose gels. Agarose concentration had only a small effect on the CT numbers of BaSO4 suspensions. CONCLUSION: BaSO4-loaded agarose is an effective material for construction of multimodality imaging phantoms. It provides adequate signal intensity for MR imaging and attenuation for CT, with independently variable contrast in both modalities.

Agar↗