Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “POLYMERS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Molecular sieving by polymer solutions: dependence on particle and polymer size, independence of polymer entanglement.

The previous postulate of collision and displacement mechanisms of molecular sieving based on a biphasic plot of retardation coefficient vs particle radius ("R-plot") was extended and modified in four ways: i) A wider size range of particles and polymers confirmed the biphasic nature of the R-plot and, in addition, revealed a third mechanistic phase in the largest size range of particles and polymers which exhibits a positive slope in plots of retardation coefficient vs log (particle or polymer size), presumably denoting a collision mechanism. ii) Peaks of retardation in polyethyleneglycol (PEG) solutions were found with a particle M(r) of 10(7) independently of the M(r) of PEG, and with a PEG M(r) of 4 x 10(5) independently of particle M(r), showing that the retardation mechanism is not qualitatively a function of the particle/polymer size ratio as postulated previously, although quantitatively retardation is directly related to the size of particle and polymer. iii) Items i) and ii) were confirmed using band width in lieu of mobility measurement. iv) The entanglement threshold, c*, was found to decrease monotonically across the entire polymer size range in which the triphasic retardation takes place. Thus c* cannot be the sole cause for a non-monotonic change of retardation or normalized relative bandwidth with polymer size and particle size. Moreover, Ferguson plots across c* do not reflect it in any way.

Electrophoresis, Capillary↗

Polymer-solvent interaction parameters in polymer solutions at high polymer concentrations.

Molecular mass and temperature dependences of the polymer-solvent interaction parameter have been investigated in the extreme interval of high polymer concentration using inverse gas chromatography (IGC). The observed molecular mass dependence has been compared with the predictions of a theoretical model, which emphasises the role of intramolecular contacts in the polymer chain. The model reproduces reasonably well the molecular mass dependence. However, enthalpic and entropic contributions of the interaction parameter, obtained from IGC measurements at different temperatures, exhibit behaviours difficult to explain in the framework of the current models.

Chromatography, Gas↗

Assessment of polymer-polymer interactions in blends of HPMC and film forming polymers by modulated temperature differential scanning calorimetry.

PURPOSE: To assess the miscibility and phase behavior of binary blends of hydroxypropylmethyl cellulose (HPMC) with hydroxypropyl cellulose (HPC), methylcellulose (MC), and polyvinylpyrrolidone (PVP). METHODS: Polymer-polymer miscibility was assessed by measurement of the glass transition temperature (Tg) and the width of the glass transition temperature (W-Tg), using modulated temperature differential scanning calorimetry (MTDSC). RESULTS: HPMC K4M/PVP and HPMC E5/MC blends were miscible as evidenced by a single, composition dependent, Tg throughout the entire composition range. HPMC/HPC blends were immiscible at all compositions. For the miscible blends, the variation in Tg with blend composition was compared to the values predicted by the Fox and Couchman-Karasz equations. At intermediate blend compositions, HPMC K4M/PVP blends exhibited negative deviations from ideal behavior. The Tg of the HPMC E5/MC blends was found to follow the Fox equation. The W-Tg measurements of the miscible blends gave evidence of phase separation at certain compositions. CONCLUSIONS: MTDSC was shown to be a useful technique in characterizing the interactions between some commonly used pharmaceutical polymers.

Calorimetry, Differential Scanning↗

The swelling phenomenon of acrylic resin polymer teeth at the interface with denture base polymers.

PURPOSE: This study examined the interface between acrylic resin polymer teeth and denture base polymers. MATERIAL AND METHODS: An autopolymerized denture base polymer was cured either at 30 degrees C, 50 degrees C, or 70 degrees C, and a heat-cured denture base polymer was cured at 100 degrees C in contact with acrylic resin polymer teeth. The specimens were ground wet and polished to a thickness of 0.21 mm for the examination of the interface with a light microscope. The surface of the specimens was then treated with the solvent tetrahydrofuran, and the specimens were examined with a scanning electron microscope (SEM). RESULTS: As a result of grinding, the inner parts of the beads at the interface of the teeth were exposed to the denture base polymer. The inner part in these polymer beads of the polymer teeth swelled to a depth of 3 microns when the autopolymerized polymer was cured at 30 degrees C. When cured at 70 degrees C, the thickness of the swelled layer was 21 microns (p < 0.001). Microscopically, the interface between the heat-cured denture base polymer and the polymer teeth appeared diffuse in the region of the interpenetrating polymer networks (IPN) and the matrix. The IPN appeared as a separate zone in the outer parts of the beads of the teeth, both with the light microscope and with the SEM. CONCLUSIONS: The results suggest that by increasing the polymerization temperature, the monomers of the denture base polymers diffused more effectively into acrylic resin polymer teeth. This increases the bond strength between the polymer teeth and the denture base polymer.

Acrylic Resins↗

Purification of protein and recycling of polymers in a new aqueous two-phase system using two thermoseparating polymers.

In this study we present a new aqueous two-phase system where both polymers are thermoseparating. In this system it is possible to recycle both polymers by temperature induced phase separation, which is an improvement of the aqueous two-phase system previously reported where one of the polymers was thermoseparating and the other polymer was dextran or a starch derivative. The polymers used in this work are EO50PO50, a random copolymer of 50% ethylene oxide (EO) and 50% propylene oxide (PO), and a hydrophobically modified random copolymer of EO and PO with aliphatic C14H29-groups coupled to each end of the polymer (HM-EOPO). In water solution both polymers will phase separate above a critical temperature (cloud point for EO50PO50 50 degrees C, HM-EOPO, 14 degrees C) and this will for both polymers lead to formation of an upper water phase and a lower polymer enriched phase. When EO50PO50 and HM-EOPO are mixed in water, the solution will separate in two phases above a certain concentration i.e. an aqueous two-phase system is formed analogous to poly(ethylene glycol) (PEG)/dextran system. The partitioning of three proteins, bovine serum albumin, lysozyme and apolipoprotein A-1, has been studied in the EO50PO50/HM-EOPO system and how the partitioning is affected by salt additions. Protein partitioning is affected by salts in similar way as in traditional PEG/dextran system. Recombinant apolipoprotein A-1 has been purified from a cell free E. coli fermentation solution. Protein concentrations of 20 and 63 mg/ml were used, and the target protein could be concentrated in the HM-EOPO phase with purification factors of 6.6 and 7.3 giving the yields 66 and 45%, respectively. Recycling of both copolymers by thermoseparation was investigated. In protein free systems 73 and 97.5% of the EO50PO50 and HM-EOPO polymer could be recycled respectively. Both polymers were recycled after aqueous two-phase extraction of apolipoprotein A-1 from a cell free E. coli fermentation solution. Apolipoprotein A-1 was extracted to the HM-EOPO phase with contaminating proteins in the EO50PO50 phase. The yield (78%) and purification factor (5.5) of apolipoprotein A-1 was constant during three polymer recyclings. This new phase system based on two thermoseparating polymers is of great interest in large scale extractions where polymer recycling is of increasing importance.

Apolipoprotein A-I↗

Small changes in the polymer structure influence the adsorption behavior of fibrinogen on polymer surfaces: validation of a new rapid screening technique.

Numerous studies conclude that the selective adsorption of plasma proteins on materials contacting blood or tissue affects all subsequent interactions related to the biocompatibility of artificial surfaces. However, there are only a few studies available, which clearly demonstrate that there is a correlation between surface chemistry and selective protein adsorption. Detailed knowledge of such correlations would facilitate the design of biocompatible materials. In this study, a rapid, fluorescence-based, screening technique using a 384-well format for polymer-protein interactions was developed. The screening assay was used to measure the adsorption of human fibrinogen on 46 test polymers (44 polyarylates selected from a combinatorial library of tyrosine-derived polyarylates, and two lactide-based polymers). In this library of polyarylates, structural changes are generated by variations in either the polymer backbone or the polymer pendent chain. Although no overall trend between polymer hydrophobicity and fibrinogen adsorption could be identified using the entire set of test polymers (R(2) = 0.43), fibrinogen adsorption was clearly correlated with variations in the pendent chain structure. Thus, when the test polymers were grouped by backbone composition, increased hydrophobicity of the pendent chain was significantly correlated with reduced fibrinogen adsorption. The following R(2) coefficients within the polymer backbone groups were determined: 0.87 (diglycolates); 0.98 (glutarates); 0.73 (adipates); 0.87 (suberates); 0.67 (3-methyl-adipates). Our results demonstrate that it is possible to screen for protein-material interactions in a cost-effective fashion using a miniaturized immunofluorescence technique. Further, we demonstrate that small changes in chemical composition can significantly influence the adsorption of human fibrinogen on polymer surfaces. The lactide-based polymers were among those polymers exhibiting the highest tendency to adsorb fibrinogen. This information may be useful when polymers have to be selected for specific biomaterial applications.

Adsorption↗

Shear bond strength of denture reline polymers to denture base polymers.

PURPOSE: This study was undertaken to characterize the shear bond strength established between four denture base polymers and four denture reline polymers. MATERIALS AND METHODS: Cylindric columns of denture reline polymers were bonded to columns of denture base polymers. Specimens were immersed in water for 4 months and then thermocycled. The strength at which the bond failed under shear stress was recorded. RESULTS: Significant differences in bond strength existed among the specimens because of the denture base polymer variable, the denture reline polymer variable, and their interaction (P < .05). A light-activated denture base polymer (Triad) bonded adequately with a light-activated reline polymer (Triad) but less well with the other reline polymers tested. The bond strength established between some denture base polymers and a different light-activated reline polymer (Rebaron LC) was relatively low. CONCLUSION: The type of denture base polymer and denture reline polymer affected the shear bond strength between them.

Acrylic Resins↗

Preparation of blood-compatible hollow fibers from a polymer alloy composed of polysulfone and 2-methacryloyloxyethyl phosphorylcholine polymer.

Blood-compatible hollow fibers were successfully prepared from a polymer alloy composed of polysulfone (PSf) and the 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer. To improve the hydrophilicity, fouling-resistance characteristics, and blood compatibility of the PSf hollow fiber in a hemodialyzer, an MPC polymer that can be blended with PSf was synthesized in order to prepare the polymer alloy (PSf/MPC polymer). The contents of the MPC polymer blended in the PSf were 7 and 15 wt%. The PSf/MPC polymer hollow fiber could be prepared by both wet and dry-wet processing methods. The hollow fiber took an asymmetric structure, that is, the hollow-fiber membrane had a dense skin layer on the porous sponge-like structure. The mechanical strength was higher than that of conventional PSf hollow fibers for hemodialysis. The surface characterization of the PSf/MPC polymer hollow fiber by x-ray photoelectron spectroscopy revealed that the MPC units were concentrated at the surface. The permeability for solutes through the PSf/MPC polymer hollow fibers was measured for 4 h. The permeabilities of both a low-molecular-weight compound and protein were greater than those of the PSf hollow fibers. The amount of adsorbed protein was lower on the PSf/MPC polymer hollow fiber when compared to that of the PSf hollow fiber. Moreover, platelet adhesion was also effectively inhibited on the PSf/MPC polymer hollow fiber. Based on these results, the addition of the MPC polymer to the PSf is a very useful method to improve the functions and blood compatibility of the hollow fiber.

Biocompatible Materials↗

Bioadhesive polymers as platforms for oral controlled drug delivery II: synthesis and evaluation of some swelling, water-insoluble bioadhesive polymers.

A series of cross-linked, swellable polymers was sythesized from monomers such as acrylic acid, methacrylic acid, and others with various cross-linking agents to produce a range of polymers differing in charge densities and hydrophobicity. The densities, rate, and extent of hydration of the polymers were determined. An increase in the number of hydrophobic groups in the polymer structure reduced hydration whereas the density of the polymer was unaffected. A sensitive in vitro method for measuring adhesion of polymer to tissue from the rabbit stomach was developed. Polymers of acrylic acid loosely cross-linked (0.3%, w/w) with three different agents, divinyl glycol, 2,5-dimethyl-1,5-hexadiene, and divinylbenzene, showed the same degree of bioadhesion while poly(methacrylic acid-divinylbenzene) showed reduced bioadhesion. The small percent of cross-linking agent, irrespective of physicochemical properties, did not contribute substantially to bioadhesion, whereas the starting monomer had a large effect. The effect of pH on the bioadhesion of poly(acrylic acid-divinyl glycol) was studied at constant temperature, ionic strength, and osmolality. The polymer showed maximum adhesion at pH 5 and 6 and a minimum at pH 7. Gastrointestinal transit studies of cross-linked polymers in rats were studied. Poly(acrylic acid-divinyl glycol) and poly(methacrylic acid-divinylbenzene) were shown to have substantially longer GI transit times than the control, Amberlite 200 resin beads. The delay in transit time was due to bioadhesion of the polymer to the mucin-epithelial cell surface which was clearly observable on animal autopsy. The acrylic acid polymer showed a longer GI transit time than the methacrylic acid polymer, and this in vivo GI transit result is consistent with in vitro bioadhesion test results.

Acrylic Resins↗

Affinity partitioning. A method for purification of proteins using specific polymer-ligands in aqueous polymer two-phase systems.

We describe a method, called affinity partitioning, for the purification of proteins containing specific ligand binding receptor sites. This method adds specificity to the procedures for protein purification with aqueous polymer two-phase systems by introduction of a polymer derivative, coupled to an appropriate ligand. The addition of a polymer-ligand that partitions predominantly into one phase shifts the protein that binds this substance to the same phase. By performing countercurrent distribution in the presence of a polymer-ligand, the protein that binds the polymer-ligand can be separated from a heterogenous mixture. One example of affinity paritioning used dextran as the polymer-ligand. Dextran was chosen since it is a constituent of the most commonly used system for partitioning proteins. In a dextran-poly(ethylene oxide) system, concanavalin A bound dextran and partitioned predominantly into the dextran-rich phase. The addition of the specific competitor, D-mannose, displaced the partition coefficient toward unity, while the application of L-fucose, a noncompetitor, had little effect. Application of affinity partitioning to the purification of another protein required the synthesis of a specific polymer-ligand. To study this we synthesized dinitrophenyl-poly-(ethylene oxide), which binds specifically to S-23 myeloma protein. Addition of dinitrophenyl-poly(ethylene oxide) to the dextran-poly(ethylene oxide) phase system shifted the S-23 myeloma protein into the poly(ethylene oxide)-rich phase. epsilon-N-dinitrophenyl-L-lysine, by competing with binding of dinitrophenyl-poly(ethylene oxide), antagonized the latter's effect on the partition coefficient of S-23 myeloma protein. By adding various amounts of dinitrophenyl-poly-(ethylene oxide), we correlated the partition coefficient with concentration of polymer-ligand. A model of the action of polymer-ligand derivatives on the partition coefficient, derived from thermodynamic considerations, was found to be consistent with the experimental data relating the concentration of polymer-ligand and partition coefficient. Affinity partitioning should prove to be a useful complement to affinity chromatography in the purification of mixtures of proteins. Since cells and subcellular particles may be purified with aqueous polymer two-phase systems, affinity partitioning might be applied to their fractionation by using polymer-ligands specific for unique surface receptors.

Animals↗

Polymers with thiol groups: a new generation of mucoadhesive polymers?

PURPOSE: To improve the mucoadhesive properties of polycarbophil by the introduction of sulfhydryl groups. METHODS: Mediated by a carbodiimide, cysteine was covalently bound to polycarbophil (PCP) forming amide bonds between the primary amino group of the amino acid and the carboxylic acid moieties of the polymer. The amount of covalently attached cysteine and the formation of disulfide bonds within the modified polymer were determined by quantifying the share of thiol groups on the polymer conjugates with Ellman's reagent. The adhesive properties of polycarbophil-cysteine conjugates were evaluated in vitro on excised porcine intestinal mucosa by determining the total work of adhesion (TWA). RESULTS: Depending on the weight-ratio of polycarbophil to cysteine at the coupling reaction, e.g., 16:1 and 2:1, 0.6+/-0.7 micromole and 5.3+/-2.4 micromole cysteine, respectively, were covalently bound per g polymer. The modified polymer displayed improved internal cohesive properties due to the formation of interchain disulfide bonds within the polymer in aqueous solutions at pH-values above 5. Adhesion studies revealed strongly improved adhesive properties. Whereas the TWA was determined to be 104+/-21 microJ for the unmodified polymer, it was 191+/-47 microJ for the polymer-cysteine conjugate 16:1 and 280+/-67 microJ for the polymer-cysteine conjugate 2:1. CONCLUSIONS: Polymers with thiol groups might represent a new generation of mucoadhesive polymers displaying comparatively stronger adhesive properties.

Acrylic Resins↗

Surface Modification of Conventional Polymers by Depositing Plasma Polymers of Trimethylsilane and of Trimethylsilane + O2.

The dynamic wetting properties of TMS (trimethylsilane) and TMS + O2 plasma-deposited films on ten low energy conventional polymers were investigated using the Wilhelmy balance method. Plasma deposition resulted in wetting properties that were independent of the underlying polymer substrate for the majority of polymers studied. TMS plasma modification resulted in virtually the same degree of hydrophobicity with an average cosine of the dynamic advancing contact angle from the first immersion, cos &theta;D,a,1 = -0.381 (&theta;D,a,1 = 112 +/- 3.6), for eight of the ten polymers. PTFE and UHMWPE were slightly more hydrophobic after TMS plasma treatment with an average cos &theta;D,a,1 = -0.785 (&theta;D,a,1 = 141 +/- 4.2). TMS + O2 plasma modification resulted in high wettability of all polymers with an average cos &theta;D,a,1 = 0.654 (&theta;D,a,1 = 49.2 +/- 11.7). Dynamic hysteresis, mainly a result of the change in meniscus shape during immersion and emersion, and intrinsic hysteresis, due to the extent of surface configuration change, were both found to vary according to the size of the polymer plate. In general, dynamic hysteresis can be quite large for more hydrophobic TMS treated polymers and considerably smaller for highly hydrophilic TMS + O2 treated polymers. The extent of intrinsic hysteresis of only TMS treated polymers was found to be independent of the underlying polymers within the time-scale of wetting. TMS + O2 plasma treatment resulted in wide variations in intrinsic hysteresis probably due to substrate specific etching of oxygen plasma species. The wettability of the untreated and TMS and TMS + O2 treated polymers, indicated by the static "advancing" contact angles from the sessile droplet method and dynamic "advancing" and "receding" contact angles from the Wilhelmy balance method, were found to conform well to the correlation, cos &theta;S = (cos &theta;D,a,1 + cos &theta;D,r,1)/2. Copyright 1999 Academic Press.

Journal Article↗

Influence of protein on polysiloxane polymer formation: evidence for induction of complementary protein-polymer interactions.

Results presented in the companion paper suggested that the protein itself might be actively involved in the polymerization process while being entrapped in polysiloxane polymers. It was speculated that the organo-functional side chains on the silanol monomers (or small oligomers) tended to associate with complementary residues on the protein surface during the polymerization process. This phenomenon might lead to complementary binding pockets for the protein on the polymer. To investigate this possibility, polysiloxane polymers were prepared from 3-aminopropyltriethoxysilane and tetraethylorthosilicate (1:3) in the presence of two proteins: urease and BSA. The entrapped proteins were removed by pronase digestion and washing and the resulting polymers evaluated for their ability to again bind the two proteins. It was found that urease preferentially bound to the polymer made in the presence of urease, and BSA preferentially bound to the polymer made in the presence of BSA. The absolute preferential binding excess was greater (30%) for urease binding relative to that observed for BSA (3%). However, in both cases the same relative binding ratio of 1.5 or 50% excess was found. A similar study using the closely related hemoglobin and myoglobin proteins failed to show comparable excess binding in the presence of the predetermined protein. In the latter case, it was demonstrated that the rebound proteins did not equilibrate with labeled solution proteins, indicating a very tight association with the polymer surface possibly masking any specificity which existed. However, it was possible to show that urea release of rebound hemoglobin from the polymer made in the presence of hemoglobin was less than for myoglobin bound to the same polymer and visa versa, again suggesting induced properties unique to the polymer prepared with the predetermined protein. To the extent that this notion of induced complementary order is correct, it may have implications in the development of protein specific adsorbants and in our understanding of polymer surface adhesion and the molding of template fine structure.

Binding Sites↗

Preparation of solid dispersions of nonsteroidal anti-inflammatory drugs with acrylic polymers and studies on mechanisms of drug-polymer interactions.

This work studied the mechanisms of interaction between Eudragit RS100 (RS) and RL100 (RL) polymers with 3 nonsteroidal anti-inflammatory drugs: diflunisal (DIF), flurbiprofen (FLU), and piroxicam (PIR). Solid dispersions of polymers and drugs at different weight ratios were prepared by coevaporation of their ethanol solutions. The resulting coevaporates were characterized in the solid state (Fourier-transformed infrared spectroscopy (FT-IR) IR, differential scanning calorimetry, powder-x-ray diffractometry) as well as by studying the in vitro drug release in a gastroenteric environment. Absorption tests from drug solutions to the solid polymers were also performed to better explain the mechanism of interactions between them. The preparative conditions did not induce changes in the crystalline state of the drugs (amorphization or polymorphic change). Drugs strongly interacted with the ammonium groups present in polymers, giving an electrostatic interaction that reinforced the mere physical dispersion of drug molecules within polymer networks. Such interactions are related to the chemical structure of the drugs and to their dissociated or undissociated state. The dispersion of drugs in the polymer matrices strongly influenced their dissolution rate, which appeared slower and more gradual than those of the pure drugs, when polymer ratios were increased. RL coevaporates usually displayed higher dissolution rates. The kinetic evaluation of the dissolution profile, however, suggested that both the drug solubility in the external medium and its diffusion capacity within the polymer network are involved. In the sorption experiments, RL showed a greater adsorptive capacity than RS, in relation to the greater number of quaternary ammonium functions, which behave as activity sites for the electrostatic interactions. In the presence of Tris-HCl buffer (pH 7.4), drug adsorption was reduced, as a consequence of the competition of the chloride ions with drug anions for the polymer binding sites. In general, DIF and FLU displayed a similar interaction with RS and RL active sites; PIR's was different. The different molecular structures of these agents can justify such findings. The presence of a carboxyl group (instead of another dissociable acidic moiety, like the hydroxy-enolic one in the PIR molecule) could help explain the strong interaction with RS and RL polymers' quaternary ammonium centers. Preliminary studies like ours are important in helping develop better forecasting and increasing the understanding of the incorporation/release behavior of drugs from particulate delivery systems that can be made from these polymers.

Acrylic Resins↗

Thermal property and processability of elastomeric polymer alloy composed of segmented polyurethane and phospholipid polymer.

To develop a thermoplastic elastomer with high blood compatibility, a 2-methacryloyloxyethyl phosphorylcholine (MPC) polymer was blended with the segmented polyurethane (SPU) for preparing the polymer alloy. A tensile strength measurement was carried out to evaluate its mechanical strength. The mechanical strength of the SPU/MPC polymer alloy is the same as that of the original SPU and sufficient for use in medical applications. The thermal properties of the polymer alloy were evaluated by differential scanning calorimetry (DSC). The DSC curves indicated that the MPC polymer blended into the SPU did not affect the hard segment domain of the SPU. The SPU/MPC polymer alloy can be processed by heat treatment at 150 degrees C. Even after heat treatment, the SPU/MPC polymer alloy showed good mechanical properties, and MPC units were observed on the surface. Protein adsorption from human plasma was observed to evaluate the blood compatibility of the polymer alloy. The SPU/MPC polymer alloy suppressed protein adsorption on the surface before and after the heat treatment. Based on these results, it is concluded that the SPU/MPC polymer alloy has an excellent potential for application in various medical devices.

Adsorption↗

Molecular modeling of polymers 16. Gaseous diffusion in polymers: a quantitative structure-property relationship (QSPR) analysis.

PURPOSE: The purpose of this study was to identify the key physicochemical molecular properties of polymeric materials responsible for gaseous diffusion in the polymers. METHODS: Quantitative structure-property relationships, QSPRs were constructed using a genetic algorithm on a training set of 16 polymers for which CO2, N2, O2 diffusion constants were measured. Nine physicochemical properties of each of the polymers were used in the trial basis set for QSPR model construction. The linear cross-correlation matrices were constructed and investigated for colinearity among the members of the training sets. Common water diffusion measures for a limited training set of six polymers was used to construct a "semi-QSPR" model. RESULTS: The bulk modulus of the polymer was overwhelmingly found to be the dominant physicochemical polymer property that governs CO2, N2 and O2 diffusion. Some secondary physicochemical properties controlling diffusion, including conformational entropy, were also identified as correlation descriptors. Very significant QSPR diffusion models were constructed for all three gases. Cohesive energy was identified as the main correlation physicochemical property with aqueous diffusion measures. CONCLUSIONS: The dominant role of polymer bulk modulus on gaseous diffusion makes it difficult to develop criteria for selective transport of gases through polymers. Moreover, high bulk moduli are predicted to be necessary for effective gas barrier materials. This property requirement may limit the processing and packaging features of the material. Aqueous diffusion in polymers may occur by a different mechanism than gaseous diffusion since bulk modulus does not correlate with aqueous diffusion, but rather cohesive energy of the polymer.

Carbon Dioxide↗

Molar mass profiling of synthetic polymers by free-solution capillary electrophoresis of DNA-polymer conjugates.

The molar mass distribution of a polymer sample is a critical determinant of its material properties and is generally analyzed by gel permeation chromatography or more recently, by MALDI-TOF mass spectrometry. We describe here a novel method for the determination of the degree of polymerization of polydisperse, uncharged, water-soluble polymers (e.g., poly(ethylene glycol) (PEG)), based upon single-monomer resolution of DNA-polymer conjugates by free-solution capillary electrophoresis. This is accomplished by end-on covalent conjugation of a polydisperse, uncharged polymer sample (PEG) to a monodisperse, fluorescently labeled DNA oligomer, followed by electrophoretic analysis. The monodisperse, charged DNA "engine" confers to each conjugate an equal amount of electromotive force, while the varying contour lengths of the uncharged, polydisperse polymers engender different amounts of hydrodynamic drag. The balance of electromotive and hydrodynamic forces enables rapid, high-resolution separation of the DNA-polymer conjugates as a function of the size of the uncharged PEG tail. This provides a profile of the molar mass distribution of the original polymer sample that can be detected by laser-induced fluorescence through excitation of the dye-labeled DNA. We call this method free solution conjugate electrophoresis (FSCE). Theory-based analysis of the resulting electrophoresis data allows precise calculation of the degree of polymerization of the PEG portion of each conjugate molecule. Knowledge of the molecular mass of the uncharged polymer's repeat unit allows for direct calculation of the molar mass averages as well as sample polydispersity index. The results of these analyses are strikingly reminiscent of MALDI-TOF spectra taken of the same PEG samples. PEG samples of 3.4-, 5-, and 20-kDa nominal average molar mass were analyzed by FSCE and MALDI-TOF; the values of the molar mass averages, Mw and Mn, typically agree to within 5%. Measurements and molar mass calculations are performed without any internal standards or calibration. Moreover, when DNA-polymer conjugate analysis is performed in a chip-based electrophoresis system, separation is complete in less than 13 min. FSCE offers an alternative to MALDI-TOF for the characterization of uncharged, water-soluble polymers that can be uniquely conjugated to DNA.

DNA↗

The effect of heat- and auto-polymerized denture base polymers on clonogenicity, apoptosis, and necrosis in fibroblasts: denture base polymers induce apoptosis and necrosis.

Eluates from poly(methyl methacrylate)-based denture base polymers have recently been found to enhance death by apoptosis and necrosis in U-937 human monoblastoid cells. The present study investigated the potential of such polymers to induce apoptosis and/or necrosis and to alter clonogenicity in L929 murine fibroblasts. A fibroblast cell line was chosen because the impairment of fibroblasts subjacent to denture bases may result in a weaker or more permeable mucosa. Two aspects were addressed: the effect of direct contact with the denture base polymers and the effect of eluates extracted from the polymers. For this purpose L929 fibroblasts were seeded on disks manufactured from three heat-polymerized and four autopolymerized denture base polymers or in different concentrations of their eluates. The effects were evaluated by light, fluorescent, confocal and electron microscopy, counting of colonies, and flow cytometry. Disks and eluates of all polymers enhanced cell death by apoptosis and necrosis in L929 cells and decreased their clonogenic potential in a dose-dependent manner. Apoptosis was the main form of cell death. In general, the deleterious effects were stronger when cells were plated directly on the polymer disks than in the eluates. The autopolymerized polymers, except one, yielded higher percentages of apoptosis and necrosis than the heat-polymerized polymers. The results of the study indicated that poly(methyl methacrylate)-based denture base polymers trigger death-signals in L929 fibroblasts and open doors for possible modulation of the cell/biomaterial interaction.

Animals↗