Search PubMedSearch

SEARCH · Search PubMed

Results for “Orthotic Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

60 recordsLinked to original sources

Hand Pain and Sensory Deficits: Carpal Tunnel Syndrome: 2026 Revision. Using the Evidence to Guide Musculoskeletal Rehabilitation Practice.

SYNOPSIS: Carpal tunnel syndrome is common in women, manual laborers, and during pregnancy; it is often associated with medical conditions such as obesity and diabetes. The musculoskeletal rehabilitation clinician's approach to managing hand pain and sensory deficits associated with carpal tunnel syndrome should include prescribing a neutral-positioned wrist orthosis plus instructing the patient on how to modify activities, adjust ergonomics, and reduce exposure to risk factors. Here, we present for clinicians the most up-to-date information to guide their work in managing hand pain and sensory deficits associated with carpal tunnel syndrome. J Orthop Sports Phys Ther 2026;56(9):622-623. doi:10.2519/jospt.2026.0502.

Humans

Insights from expert panels on the EU clinical evaluation consultation procedure.

BACKGROUND: The Clinical Evaluation Consultation Procedure (CECP) under the EU Medical Device Regulation aims to strengthen and harmonize the assessment of high-risk medical devices. This review summarizes early insights from expert panels to support improved clinical evaluation practices. RESEARCH DESIGN AND METHODS: This review analyses 34 expert panel opinions derived from 281 CECP submissions between April 2021 and December 2025. Statements from opinions were systematically extracted, de-duplicated, and grouped into thematic categories, with independent review and validation. The analysis focuses on common challenges found during the consultation procedure of the expert panels on the content of the clinical assessment in relation to clinical evidence, benefit-risk assessment, intended purpose alignment, and post-market clinical follow-up planning. RESULTS: Expert panel findings highlight recurrent issues in the sufficiency, consistency, and transparency of clinical evidence, underscoring the need for improved standardization and clearer guidance. CONCLUSIONS: Strengthening documentation quality and alignment across stakeholders will enhance the robustness, efficiency, and predictability of conformity assessments for high-risk medical devices.

Humans

Percutaneous left ventricular assist device in cardiogenic shock associated with and without acute myocardial infarction: a real-world retrospective cohort study.

BACKGROUND: Percutaneous left ventricular assist devices (pLVAD, such as Impella), are increasingly used for cardiogenic shock (CS). Outcomes may differ between acute myocardial infarction-related CS (AMI-CS) and non-AMI CS due to differing pathophysiology and trajectories. METHODS: Using the USA TriNetX Network (2016-2024), we identified adults with CS treated withpLVAD. AMI-CS was defined by MI within seven days of implantation; non-AMI CS included all patients with CS not attributable to acute MI, representing heterogeneous etiologies such as decompensated cardiomyopathy, myocarditis, valvular failure, pulmonary vascular causes, and arrhythmic shock. Patients with recent coronary artery bypass graft (CABG) were excluded. Propensity matching produced two balanced cohorts (n&#x2009;=&#x2009;2,026 each). RESULTS: Among 6,873 AMI-CS and 4,521 non-AMI CS patients, matched groups were similar (mean age 63&#x2009;years, 26% female). AMI-CS had higher mortality at 30&#x2009;days (hazard ratio [HR] 1.19, p&#x2009;=&#x2009;0.002), 90&#x2009;days (HR 1.13, p&#x2009;=&#x2009;0.02), and 180&#x2009;days (HR 1.14, p&#x2009;=&#x2009;0.007). Heart failure (HF) exacerbations (HR 1.21, p&#x2009;<&#x2009;0.001) and pulmonary edema (HR 1.23, p&#x2009;=&#x2009;0.005) were also more common in AMI-CS. Stroke, ventricular arrhythmias, cardiac arrest, acute kidney injury, major bleeding, vascular complications, and hemodialysis were comparable. CONCLUSION: AMI-CS patients supported with pLVAD experienced higher mortality and greater HF-related morbidity than non-AMI CS.

Humans

Effect of Music on Pain, Anxiety, and Satisfaction During Intrauterine Device Application: A Randomized Clinical Trial.

This randomized controlled trial aimed to determine the effect of music played during intrauterine device (IUD) insertion on perceived pain, state anxiety, and satisfaction levels. The study was conducted with 70 women who applied to a maternal and child health and family planning center and were randomly assigned to the intervention and control groups using simple randomization. Data were collected using a Demographic Information Form, the State-Trait Anxiety Inventory (STAI-I), and the Visual Analog Scale (VAS), as well as Bluetooth speakers and the musical piece Evgeny Grinko-Valse. Participants in the intervention group listened to music before and during the IUD insertion procedure, whereas the control group received routine care only. Data were analyzed using SPSS version 26 with appropriate descriptive and inferential statistical methods. Women in the music group had significantly lower perceived pain (p&#x2009;<&#x2009;0.001) and state anxiety levels during the procedure (p&#x2009;=&#x2009;0.022), and significantly higher satisfaction levels compared with the control group (p&#x2009;<&#x2009;0.001). In addition, post-procedure state anxiety levels were positively correlated with pain intensity experienced during and after the procedure (r&#x2009;=&#x2009;0.542 and r&#x2009;=&#x2009;0.496, respectively; p&#x2009;<&#x2009;0.001), and negatively correlated with procedural satisfaction (r&#x2009;=&#x2009;-0.652; p&#x2009;<&#x2009;0.001). These findings suggest that listening to music during IUD insertion may help reduce pain and anxiety while potentially enhancing patient satisfaction. Trial Registration: NCT06215183.

Humans

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Phase 1 Study Evaluating Gefurulimab Pharmacokinetics and Safety Following Delivery Via Autoinjector or Prefilled Syringe With Needle Safety Device in Healthy Adults.

PURPOSE: Gefurulimab, a novel dual-binding nanobody targeting complement component 5 (C5), is in clinical development for anti-acetylcholine receptor antibody-positive generalized myasthenia gravis. Gefurulimab has a low molecular weight, enabling subcutaneous (SC) self-administration by autoinjector (AI) or prefilled syringe with needle safety device (PFS-SD). We compared gefurulimab pharmacokinetic (PK) exposure and safety in healthy adults following a single SC dose administered by AI versus PFS-SD. METHODS: In this phase 1, open-label, randomized, parallel-group study (NCT06208488), healthy participants aged 18 to 65 years were stratified by weight and randomized equally to 1 of 6 combination groups of device and injection site (abdomen/thigh/upper arm). Participants received a single SC dose of gefurulimab on day 1 and were assessed throughout the 92-day evaluation period. Primary endpoints were PK parameters for each device: maximum observed concentration (Cmax) and area under the serum concentration-time curve (AUCinf, AUClast). PK across injection sites, pharmacodynamics, safety, immunogenicity, and device performance were also assessed. FINDINGS: Overall, 175 participants were randomized: AI (n = 87), PFS-SD (n = 88). Geometric least squares mean ratios (90% CI) comparing AI/PFS-SD for Cmax, AUCinf, and AUClast were 97.6% (94.5-100.8), 99.6% (96.1-103.3), and 98.8% (95.2&#x2012;102.6), respectively. Secondary analyses found no meaningful differences in PK parameters across injection sites. Serum-free C5 concentrations over time, treatment-emergent adverse event (TEAE) profiles, and antidrug antibody responses were similar between cohorts. Most TEAEs were mild; none led to study discontinuation. IMPLICATIONS: SC administration of gefurulimab by AI and PFS-SD was well tolerated with comparable exposure, meeting bioequivalence criteria.

Humans

Prothrombin complex concentrate (PCC) vs. non-PCC strategies for warfarin reversal in left ventricular assist device recipients: A systematic review and meta-analysis.

BACKGROUND: Left ventricular assist devices (LVADs) prolong survival in end-stage heart failure, and warfarin thromboprophylaxis is recommended to prevent device thrombosis and thromboembolic complications. When bleeding occurs or emergency surgery is required, rapid anticoagulation reversal is critical. Prothrombin complex concentrate (PCC) provides rapid reversal; however, its risk-benefit profile in LVAD recipients remains unclear. We conducted a systematic review and meta-analysis comparing PCC with non-PCC strategies for warfarin reversal in LVAD recipients. METHODS: MEDLINE, Embase, and Scopus were searched through June 2025 for studies of PCC versus non-PCC strategies for warfarin reversal in LVAD recipients. Two reviewers independently extracted data. Random-effects models were used to pool arm-level estimates and to pool head-to-head comparisons using mean differences or risk ratios (RRs). RESULTS: Eighteen studies involving 779 patients were included. Arm-level pooled estimates for PCC versus non-PCC comparators were 24.0% versus 15.8% for mortality, 16.5% versus 12.1% for thrombotic events, and 3.1 versus 5.7 for FFP units. Arm-level time to INR correction was longer with PCC overall (16.5 versus 13.6&#xa0;h), driven by one elective cohort, but faster within the ICH subgroup (6.0 versus 13.7&#xa0;h). In head-to-head comparisons, PCC achieved faster INR correction than non-PCC comparators (mean difference&#xa0;-&#xa0;7.6&#xa0;h; p&#xa0;=&#xa0;0.001) and required fewer FFP units (-2.6&#xa0;units; p&#xa0;=&#xa0;0.019), with no significant difference in all-cause mortality (RR 1.14; p&#xa0;=&#xa0;0.490) or thrombotic events (RR 1.43; p&#xa0;=&#xa0;0.176). CONCLUSIONS: In head-to-head studies, PCC was associated with faster INR correction and lower FFP requirements than non-PCC strategies, whereas mortality and thrombotic events did not differ significantly. Given the observational evidence, wide confidence intervals, and heterogeneity, equivalent safety cannot be established, and prospective studies are needed to define the relative safety and effectiveness of the two approaches. IMPLICATIONS FOR CLINICAL PRACTICE: PCC-based strategies may be considered for urgent warfarin reversal in LVAD recipients, particularly when rapid INR reduction or avoidance of large-volume plasma transfusion is clinically important. Treatment decisions should account for the indication, bleeding severity, and underlying thrombotic risk. TRIAL REGISTRATION: CRD42024573925.

Humans

Copper-Containing Surface Engineering for Soft-Tissue Biomedical Devices: Structure-Function Relationships and Ion Release-Driven Biological Performance, A Systematic Review.

Copper and copper-based materials have gained increasing attention for the functional modification of implantable medical devices intended for prolonged soft-tissue contact, including vascular stents, catheters, and intrauterine devices. Owing to their broad-spectrum antimicrobial activity, redox reactivity, and involvement in angiogenesis and cellular signaling, copper-based systems offer significant potential for multifunctional surface engineering. However, achieving a balance between antibacterial efficacy, corrosion behavior, controlled ion release, and cytocompatibility remains a critical challenge. This PRISMA-compliant systematic review analyzes copper-containing materials and surface modification strategies for soft-tissue biomedical applications. A structured search of Scopus, Web of Science, and PubMed (2015-2025) identified 65 eligible studies. The review encompasses bulk copper-containing alloys, electrochemical and chemical surface modification techniques, physical vapor deposition approaches, and advanced hybrid systems integrating copper with polymers, hydrogels, or metal-phenolic networks. Across the reviewed literature, antibacterial performance was strongly dependent on copper concentration, microstructural distribution, and spatiotemporal ion release profiles. Moderate, well-controlled copper incorporation frequently improved antibacterial efficacy while maintaining acceptable hemocompatibility and cytocompatibility, particularly in vascular and blood-contacting devices. In contrast, excessive copper loading often accelerated corrosion and induced adverse cellular responses. Emerging multifunctional architectures demonstrated improved regulation of biological interactions, enabling simultaneous antibacterial, antithrombotic, and proendothelial effects. Overall, copper-based surface technologies represent a versatile platform for soft-tissue implant modification. Future translational progress will require precise control of copper release kinetics and comprehensive long-term in vivo validation to ensure safety and sustained therapeutic performance. From the authors' perspective, the most promising future direction involves multifunctional copper-based hybrid coatings capable of dynamically regulating ion release, host tissue integration, and antibacterial performance simultaneously. Strategies integrating hierarchical architectures, stimulus-responsive release systems, and clinically scalable fabrication methods are expected to play a key role in translating copper-containing surfaces from experimental concepts toward commercially viable soft-tissue biomedical devices.

Copper

Analyzing the impact of subcutaneous injection needle, device, and administration characteristics on patient pain, anxiety, and safety: a systematic literature review.

The subcutaneous (SC) injection route is a commonly used and important method for therapeutic delivery of a wide range of compounds, and needle characteristics have a significant influence on patient pain, anxiety, safety, and other outcomes. This systematic review evaluates the evidence on how needle-specific characteristics (e.g. gauge, length, tip design, wall thickness, concealment) and administration- or device-related factors can affect patient-reported outcomes and clinical safety indicators during and following SC injections. A comprehensive search was conducted in MEDLINE, PubMed, Embase, and ClinicalTrials.gov in June 2024. Studies were included if they assessed the relationship between needle characteristics and pain, anxiety, safety, or related outcomes in individuals receiving SC injections. A dual-reviewer process was used for study selection, data extraction, and quality assessment. Sixty-two studies met inclusion criteria. Evidence consistently indicated that thinner and shorter needles reduced patient-reported pain and adverse events such as bruising and bleeding. Tapered and lubricated needles, hidden or retractable needle designs, and use of autoinjectors or prefilled syringes also contributed to reduced anxiety and improved user satisfaction. However, results were heterogeneous, and many studies lacked sufficient power or single-variable evaluation of individual needle parameters, limiting definitive conclusions. Needle characteristics significantly influence patient experience and safety with SC delivery. While both clinical evidence and practical experience clearly favor thinner, shorter, and concealed needles, further standardized, high-quality research is needed to isolate and quantify the specific contributions of individual needle characteristics to optimize injection practices and support patient-centered device design.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Prostate morcellation devices: a systematic review and meta-analysis of clinical outcomes and efficiency.

OBJECTIVE: To systematically evaluate the efficiency and safety of different prostate morcellators used during prostate enucleation for benign prostatic hyperplasia (BPH). METHODS: A systematic review was performed according to the Preferred Reporting Items for Systematic Review and Meta-analyses guidelines. PubMed/Medline, Scopus, and Web of Science were searched for studies published between October 2012 and May 2025. Studies reporting clinical outcomes of morcellators used during prostate enucleation were included. Primary outcome was morcellation efficiency (g/min). Secondary outcomes included intraoperative complications, device malfunction, and cost when available. Risk of bias (RoB) was assessed using the Risk Of Bias In Non-randomised Studies of Interventions (ROBINS-I), RoB 2 tool, and European Association of Urology case-series criteria. Random-effects meta-analyses and multilevel meta-regression adjusted for prostate volume were conducted. RESULTS: A total of 22 studies comprising 5980 patients were included, most undergoing holmium laser enucleation of the prostate. The most frequently evaluated devices were the Piranha&#x2122; (Richard Wolf GmbH, Knittlingen, Germany) and Lumenis VersaCut&#x2122; (Lumenis Ltd., Yokneam, Israel; 12 and 13 studies, respectively), followed by DrillCut&#x2122; (Karl Storz SE & Co. KG, Tuttlingen, Germany), MultiCut&#x2122; (Asclepion Laser Technologies GmbH, Jena, Germany), and Cyber Blade&#x2122; (Quanta System SpA, Milan, Italy) systems. Unadjusted weighted mean morcellation efficiency was 7.80&#x2009;g/min (95% confidence interval [CI] 6.26-9.34&#x2009;g/min) for Piranha, 4.70&#x2009;g/min (95% CI 3.61-5.79&#x2009;g/min) for VersaCut, 5.90&#x2009;g/min (95% CI 3.16-8.64&#x2009;g/min) for DrillCut, and 9.59&#x2009;g/min (95% CI 4.78-14.39&#x2009;g/min) for MultiCut. In volume-adjusted meta-regression using Piranha as reference, VersaCut remained significantly less efficient (-2.75&#x2009;g/min; 95% CI -4.58 to -0.92&#x2009;g/min; P&#x2009;=&#x2009;0.003), with an even greater difference in prostates >70&#x2009;mL (-4.34&#x2009;g/min). Bladder mucosal injury was the most frequently reported complication; however, relatively rare across all devices. Meta-analysis demonstrated a significantly higher risk with VersaCut compared to Piranha (risk ratio 3.22, 95% CI 1.81-5.71), with low heterogeneity. CONCLUSION: This systematic review provides a contemporary clinical benchmark of the efficiency and safety of currently available prostate morcellators. Oscillating blade systems, particularly the Piranha morcellator, demonstrated higher morcellation efficiency and a more favourable safety profile than reciprocating blade devices, with the largest performance differences observed in patients with larger prostates.

Humans

Use of wearable technologies for physical activity promotion in older adults: A systematic review.

This systematic review, conducted according to PRISMA guidelines and registered in PROSPERO (CRD420251055299), examined the use of wearable technologies for promoting physical activity (PA) in adults aged 60 years and older. Searches across five databases (PubMed, Scopus, Web of Science, CINAHL, Cochrane) identified 2438 records, of which only six randomized controlled trials published between 2021 and 2025 met inclusion criteria, with sample sizes ranging from 36 to 551 participants and mean ages between 65 and 79 years. Given the small number of included studies, findings should be interpreted as preliminary. The studies ranged from the standalone use of commercial trackers (Fitbit, Polar, ActiGraph) to multicomponent interventions combining wearables with physiotherapist feedback, telephone counseling, web-based platforms, or interactive cognitive-motor training. Wearables used alone, as in the REACT trial, produced small or non-significant PA effects. In contrast, interventions integrating devices with personalized feedback, professional support, or digital platforms, such as PROMOTE and TASMANIA, were associated with more consistent improvements in PA, physical function, and cognitive outcomes. Multicomponent programs, such as PEER and ICMT, reported broader benefits, including cognition, balance, and reductions in sedentary behavior, though these findings derive from individual trials and require replication. Risk of bias, assessed with the Cochrane Risk of Bias tool version 2 (RoB 2.0), was rated as "some concerns" for five studies and low for only one, mainly due to gaps in randomization reporting, missing data, and lack of preregistration. Tentatively, and based on a very limited evidence base, wearables may have greater impact when embedded within broader behavioral systems, incorporating feedback, coaching, or interactive components, rather than when used in isolation as passive monitoring tools. Adherence and psychosocial outcomes appeared related to comfort and perceived usefulness among older adults, though larger and more robust trials are needed to confirm these patterns.

Humans

Effectiveness of Wearable Digital Therapeutics in Improving Sleep Outcomes Among Individuals With Insomnia: Systematic Review and Meta-Analysis of Randomized Controlled Trials.

BACKGROUND: Wearable devices are increasingly used for sleep monitoring and as adjunctive treatment. Existing meta-analyses mostly pool composite digital therapies and rarely isolate stand-alone wearables or distinguish between objective and subjective end points. Whether stand-alone wearable interventions improve sleep outcomes in adults with insomnia, and which factors moderate treatment heterogeneity, remains unclear. OBJECTIVE: This study aims to evaluate the effectiveness of wearable digital interventions on sleep outcomes in adults with insomnia versus control strategies and explore moderators of effectiveness, including device-wearing position, intervention duration, and control type, using meta-regression. METHODS: This systematic review and meta-analysis was conducted in accordance with the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses) 2020 statement and the PRISMA-S (Preferred Reporting Items for Systematic Reviews and Meta&#x2011;Analyses Literature Search Extension) guideline. Five electronic databases and clinical trial registries were searched from inception to May 18, 2026. Eligible studies were randomized controlled trials (RCTs) evaluating wearable digital interventions in adults with insomnia compared with sham, waitlist, usual care, or active control conditions and had an intervention duration of at least 1 week. Study screening, data extraction, and risk-of-bias assessment were carried out independently by 2 reviewers. Pooled estimates were calculated using a restricted maximum likelihood random-effects model with the Hartung-Knapp-Sidik-Jonkman correction. Heterogeneity was assessed using the I&#xb2; statistic, and 95% prediction intervals (PIs) were calculated for the primary analyses. The certainty of evidence was rated using the GRADE (Grading of Recommendations, Assessment, Development, and Evaluation) approach. RESULTS: Sixteen RCTs (N=910) were included. Wearable digital interventions were associated with a significant reduction in objective sleep-onset latency (SOL; mean difference [MD] -4.52, 95% CI -8.38 to -0.67, PI -9.52 to 0.47 min) and a significant improvement in subjective sleep efficiency (SE; MD 2.00%, 95% CI 1.90%-2.11%, PI 1.85%-2.15%). Subjective total sleep time (TST) also showed a significant increase (MD 19.11, 95% CI 2.98-35.24, PI -16.20 to 54.43 minutes). Meta-regression showed that control type, intervention duration, and device location did not explain the heterogeneity of the insomnia severity index (ISI) (R&#xb2;=0). Sensitivity analysis confirmed the robustness of pooled ISI estimates, and an Egger test indicated no small-study effects (P=.07). Certainty of evidence ranged from moderate to high. CONCLUSIONS: Wearable digital interventions provide selective benefits for objective SOL, subjective SE, and subjective TST in adults with insomnia, with no improvement in overall ISI. Despite statistically significant effects on several sleep parameters, wide PIs, substantial heterogeneity, and limited study numbers indicate preliminary, nonconclusive findings. Wearables should be viewed as affordable adjunctive tools requiring further validation, not substitutes for first-line cognitive behavioral therapy for insomnia. Large-scale, long-term RCTs with standardized protocols and patient-level external validation are required to consolidate the evidence base.

Humans

Wearable Sleep Monitoring in Pediatric Acute Lymphoblastic Leukemia: Associations With Subjective Sleep Ratings and Neurocognitive Functioning.

BACKGROUND: Sleep disturbances are associated with increased fatigue, reduced quality of life, and neurocognitive dysfunction and have emerged as a common complication among pediatric cancer survivors. Sleep disturbances are particularly concerning given their potential to exacerbate existing neurocognitive impacts of cancer treatments. This pilot study examined the feasibility and acceptability of a home-wearable EEG-based sleep device (Sleep ProfilerTM) for acute lymphoblastic leukemia (ALL) survivors as well as associations between specific sleep parameters and neurocognitive functioning. PROCEDURE: Children (ages 8-12; M = 10 years, SD = 1.6; N = 23) >6 months post-treatment for ALL were enrolled at clinical visits and wore the Sleep ProfilerTM for two consecutive nights at home, followed by neurocognitive testing of attention, inhibitory control, working memory, and processing speed. Parents completed subjective measures of child sleep, anxiety, depression, and acceptability. Feasibility reflected the percentage of children wearing the device at least one night and the percentage of nights with good EEG quality data. RESULTS: All participants wore the device both nights, with 84% meeting the threshold for good quality measurement. Few children met recommended quantity and quality sleep thresholds based on objective measurement, including 5 patients with elevated snoring levels; 43.5% of subjective ratings fell above the threshold for sleep disturbance. Greater sleep latency was associated with worse inhibitory control (r = -0.42, p = 0.046), and total sleep time was positively associated with inhibitory control and attention. CONCLUSIONS: Findings confirm the feasibility and acceptability of home EEG sleep monitoring in school-age survivors, and associations of sleep latency and snoring with reduced neurocognitive functioning may offer modifiable risk factors for aspects of neuropsychological dysfunction common in pediatric survivorship. CLINICAL TRIAL REGISTRATION: At the time this study was conducted, we were not required to register the study on ClinicalTrials.gov. It was a single-institution feasibility study without intervention, which was not considered a clinical trial.

Humans

One in three patients with positional obstructive sleep apnea does not benefit from positional therapy: Insights from a home-based trial.

PURPOSE: Positional obstructive sleep apnea (POSA) is the most common phenotype of obstructive sleep apnea, yet patient selection for positional therapy (PT) remains suboptimal. With this analysis we aimed to clarify how many patients with POSA may not require PT because they do not habitually sleep supine at home, and how many fail vibrotactile PT despite appropriate indication. METHODS: We conducted a retrospective observational study of consecutive adults with POSA evaluated at a tertiary sleep center between 2021 and 2024. All patients underwent a home-based trial with a neck-based vibrotactile positional therapy device (Night Shift&#x2122;), consisting of monitoring mode followed by therapy mode. Outcomes included the proportion of non-supine sleepers at home, failure rate of vibrotactile PT, device compliance and differences in supine sleep time between diagnostic testing and home monitoring. RESULTS: Of 92 screened patients, 74 met inclusion criteria (mean age 60.3&#x202f;&#xb1;&#x202f;13.2 years; mean AHI 22.9&#x202f;&#xb1;&#x202f;13.3 events/h). Fifteen percent (11/74) did not habitually sleep supine at home, indicating no clinical need for PT, and an additional 14.8% (11/74) failed vibrotactile PT. Overall, 30% of patients were either unlikely to benefit from PT or failed therapy. Non-response was frequently associated with psychotropic or sedative medication use and neurological or sleep-related comorbidities. CONCLUSION: A substantial proportion of patients diagnosed with POSA either do not require or fail vibrotactile treatment in real-world conditions. Incorporating a brief home monitoring and therapy trial into routine clinical practice may optimize patient selection, reduce unnecessary costs, and improve personalized management of POSA.

Humans

Efficacy of targeted neuromodulation treatments: a clinical report.

BACKGROUND: Peripheral neuropathy is a debilitating condition characterized by chronic pain, numbness, tingling, burning, and tightness/swelling. Conventional therapies often focus on symptom management, and some patients experience chronic and refractory symptoms. RESEARCH DESIGN AND METHODS: This retrospective clinical analysis evaluated the clinical outcomes of neuromodulation neuropathy treatment using the NeuroGen-Series device in patients with diabetic peripheral neuropathy (DPN) or idiopathic peripheral neuropathy (IPN). 9,805 unique patients who underwent 133,741 treatments between 18 August 2017, and 23 July 2024, were analyzed. Patients were divided into treatment completers (&#x2265;24 sessions) and noncompleters (<24 sessions). Paired t-tests confirmed statistically significant reductions in pre- and post-treatment symptom scores (p&#x2009;<&#x2009;0.001). RESULTS: Among completers, symptom severity decreased by an average of 46.2%. Tingling and pain showed the greatest improvement, while tightness/swelling and numbness showed the least reduction. 64% of patients reported improvement after one session, and 84% reported improvement after 24 sessions. Nonresponders accounted for 5.8% of patients overall. Younger patients and those with higher initial symptom severity were more likely to discontinue treatment. CONCLUSIONS: Overall, neuromodulation treatment resulted in statistically significant reductions in symptom severity, though nonresponders and high attrition rate highlight the need for individualized treatment strategies and further investigation.

Humans

Smart crutch tipsTM real-time feedback improves adherence to partial weight-bearing protocols following lower extremity fracture surgery: a pilot study.

PURPOSE: To evaluate the effectiveness of Smart Crutch Tips&#x2122; in promoting adherence to prescribed early partial weight-bearing (PWB) protocols and to assess patient experience with real-time weight-bearing feedback during home rehabilitation. METHODS: Twenty patients with lower extremity fractures prescribed partial weight-bearing (PWB) were randomized into two groups utilizing real-time feedback crutch tips (RFC). The Intervention group (n&#x2009;=&#x2009;10) used Smart Crutch Tips&#x2122; (ComeBack Mobility Inc., Kiev, Ukraine), which provided real-time feedback on weight-bearing compliance. The Control group (n&#x2009;=&#x2009;10) also used crutches equipped with Smart Crutch Tips&#x2122;, but notifications were disabled, allowing passive data collection without patient feedback. Weight-bearing compliance was defined as the percentage of steps within &#xb1;&#x2009;10% of the prescribed target. Secondary outcomes included patient satisfaction and device usability assessed using the System Usability Scale (SUS) throughout the home rehabilitation period. RESULTS: The Intervention group demonstrated significantly greater PWB compliance compared with the Control group (73.6% vs. 21.1%, p&#x2009;<&#x2009;0.01). The Intervention group reported a mean SUS score of 84.25, indicating excellent usability. No device-related complications or adverse events were observed. Patient satisfaction, assessed through video interviews, was high, with participants in the Intervention group expressing a strong willingness to recommend the device to others with similar injuries and rating it 10 out of 10. CONCLUSION: Smart Crutch Tips&#x2122; significantly improved adherence to prescribed partial weight-bearing protocols following lower extremity fracture surgery. The RFC device demonstrated high usability, excellent patient satisfaction, and no device-related complications during home rehabilitation throughout the study period.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans