Search PubMedSearch

SEARCH · Search PubMed

Results for “Orthodontic Appliances, Removable”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

82 recordsLinked to original sources

Ageing effects on chemical, physical, mechanical, and morphological properties of clear aligners - a systematic review.

BACKGROUND: Clear aligner (CA) therapy has experienced rapid use over the past two decades to treat orthodontic malocclusions. However, evidence on CA material degradation in the oral environment remains limited and often focuses on single brands or isolated material properties. OBJECTIVES: To investigate CA ageing characteristics across different materials and brands and evaluate the chemical, physical, mechanical, and morphological changes following simulated or intraoral ageing. SEARCH METHODS: Five databases (PubMed, Web of Science, MEDLINE [Ovid], ProQuest, and Scopus) were searched to 18 March 2026, with no restrictions. ELIGIBILITY CRITERIA: Studies assessing CA properties after intraoral use or simulated ageing (thermocycling, cyclic loading, or liquid immersion) were included. DATA COLLECTION AND ANALYSIS: Study selection followed PRISMA 2020. RoB was assessed using QUIN for purely in vitro studies, JBI for cohort in vivo studies, and Cochrane RoB 2 for RCTs. Results were synthesised narratively and organised by property domain, as substantial methodological heterogeneity precluded formal meta-analysis. Where protocols were comparable, a simple pooled weighted mean was calculated and presented graphically. RESULTS: Ninety-five studies were included. RoB was low in eight studies, moderate in sixty-two, and high in twenty-five. Chemical composition remained largely stable during ageing, though some brands showed trace elemental release. Physical, mechanical, and morphological properties showed material-dependent deterioration. Pooled discolouration was greatest with coffee (weighted mean ΔE = 70.9), versus tea (ΔE = 18.4) and red wine (ΔE = 11.5), with Invisalign® consistently exceeding the clinically perceptible threshold. Force decay of 40-90% typically occurred within 48 h. Thermoplastic polyurethane (TPU)-based and directly printed aligners (DPAs) generally showed greater susceptibility than polyethylene terephthalate glycol-modified (PETG)-based aligners, though findings on hardness, roughness, and stiffness were inconsistent. CONCLUSIONS: CA materials undergo clinically relevant degradation during use, particularly in TPU-based and DPAs aligners. Clinicians may need to prioritise material-specific protocols, reinforce dietary and cleaning instructions, and consider force decay when determining aligner replacement intervals. PROSPERO number: CRD420251110248.

Humans

Double-Axis Maxillary Skeletal Expander Suggests Higher Expansion Efficiency in Early Activation: A Finite Element Analysis.

INTRODUCTION: Conventional single-axis maxillary skeletal expanders (MSE) have some drawbacks, such as limited control over maxillary expansion and possible asymmetric expansion between the anterior nasal spine (ANS) and posterior nasal spine (PNS). This report introduces a double-axis maxillary skeletal expander (DAMSE) concept to overcome these drawbacks and enhance the efficiency of maxillary skeletal expansion. MATERIALS AND METHODS: Five different DAMSE designs were compared with a conventional single-axis MSE. Finite element analysis was performed to analyse their expansion efficiency, stress magnitude and distribution occurring in a simplified bone model. RESULTS: DAMSE outperformed the single-axis MSE and provided better control over ANS and PNS expansion. During early activation, the highest expansion efficiency (31.7%) was achieved by DAMSE Model V, 13% more efficient than the single-axis MSE. This efficiency was increased to 100.8% by combining the DAMSE Model V with midpalatal suture surgery. However, with the simplified bone model, the current study could not demonstrate that DAMSE can resolve the issue of asymmetric expansion between ANS and PNS. CONCLUSIONS: An appropriately designed DAMSE can be a promising tool for maxillary expansion treatment. DAMSE offers more efficient treatment than the conventional single-axis MSE while maintaining similar levels of patient comfort and invasiveness.

Finite Element Analysis

Radiographic assessment and orthodontic intervention effects on orthodontically induced root resorption: a systematic review and meta-analysis of clinical trials.

The relative contribution of radiographic methods and characteristics of the orthodontic intervention to orthodontically induced root resorption (OIRR) remains unknown. The aims of this systematic review and meta-analysis were to (1) estimate the pooled OIRR effect across orthodontic intervention versus comparator contrasts, (2) compare pooled estimates by radiographic method (2D [two-dimensional] vs. 3D/CBCT [three-dimensional/cone-beam computed tomography]), and (3) explore whether force mechanics (intrusive versus nonintrusive) modified OIRR magnitude. Seven randomized controlled trials and one prospective study (January 2010-October 2025) were included. Only OIRR was the outcome, reported as correlation coefficients (r). The primary analysis combined within-study intervention-versus-comparator estimates. Subgroup analysis of 2D versus 3D/CBCT imaging was prespecified, whereas post-hoc analysis of intrusive versus nonintrusive mechanics was performed. The pooled analysis for the primary outcome showed a small, nonsignificant OIRR effect (r = 0.07; 95% confidence interval [CI]: -0.12 to 0.27; p = 0.372) with high heterogeneity (I2 = 84.0%). Radiographic method did not change the pooled estimates significantly (p = 0.331). Force-mechanics analysis showed that intrusive mechanics was related to significantly higher root resorption than nonintrusive mechanics (r = 0.40; 95% CI = 0.15 to 0.65 versus r = -0.03; 95% CI = -0.16 to 0.10; p < 0.001). This accounted for 87.1% of the between-study variance. The average orthodontic intervention effect on OIRR was small and not significant; however, the OIRR magnitude was strongly affected by force mechanics, particularly by intrusive forces. There was no significant difference in pooled estimates by radiographic method; however, 3D/CBCT provides superior volumetric quantification and should be used judiciously according ALARA (as low as reasonably achievable) principles.

Root Resorption

MicroRNAs in Oral Bio-Fluids as Predictive Biomarkers of Orthodontic Tooth Movement: A Systematic Review.

This systematic review was designed to assess scientific evidence of the association of microRNA expression during orthodontic tooth movement through various time points. A systematic review was performed in accordance with the PRISMA checklist. A search strategy was developed in electronic databases including Med Line, Scopus, EBSCO Host and ProQuest Dissertations & Theses Global until June 2025. Eligibility criteria included studies that investigated microRNA expression in saliva/GCF during orthodontic treatment. The risk of bias of the included studies was analysed using the QUADAS-2 and RoB-2 tools. The search retrieved 2800 records, of which nine studies were selected. Minor variations in GCF collection were noted, while stimulated saliva was collected in one study. RT-PCR and the Fluro meter accounted for the majority of miRNA estimation. Thirteen miRNAs were identified as target biomarkers for OTM regulation. Despite the high risk of bias, the evidence from the current systematic review indicates that microRNAs can be considered as potential biomarkers of orthodontic tooth movement in oral biofluids. Trial Registration: Prospero ID-CRD420251153064.

Humans

Artificial intelligence in treatment prediction for skeletal Class III malocclusion: A systematic review.

In skeletal Class III patients, treatment options range from orthodontics to orthognathic surgery. Choosing the optimal approach requires a comprehensive clinical evaluation, which may be supported by AI tools. The aim of this study was to assess the performance of AI models in predicting the need for orthognathic surgery and in identifying predictors influencing treatment decisions. A PRISMA-guided electronic database search (PubMed, Web of Science; 2009-2024; English/French) was performed to identify studies using machine learning (ML) or deep learning (DL) on cephalometric and clinical data. After screening and assessment for eligibility, 15 studies were critically appraised. Model performance was summarized using accuracy, sensitivity, specificity, and the area under the curve (AUC). ML algorithms (particularly Random Forest and XGBoost) and DL models (ResNet-based convolutional neural networks (CNNs)) achieved high accuracy for predicting surgical need. Frequently selected predictors included Wits appraisal, ANB angle, the maxillomandibular ratio (Mx/Md), overjet, and the divergence of the lower gonial angle. AI methods show promise for assisting treatment decisions in Class III malocclusion, with Random Forest and XGBoost performing well on tabular cephalometric data and CNNs on imaging. Larger, multicentre datasets and external validation are needed to improve reliability, address bias, and support clinical implementation.

Humans

Effectiveness of Platelet Rich Plasma in Reducing Oronasal Fistula and Scar Width in Primary Cleft Lip and Palate Repair-A Systematic Review and Meta-Analysis.

This review aimed to investigate platelet-rich plasma (PRP) and platelet-rich fibrin (PRF) efficiency in reducing oronasal fistula during primary cleft lip and palate repair. An extensive search of PubMed, Google Scholar, Global Index Medics (WHO), PubMed Scopus, Cochrane Central, Proquest was performed up to march 2025. Eligible studies included prospective RCTs and non-randomized controlled trials in human subjects. Patients aged 6-24&#x2009;months undergoing primary cleft lip and palate repair were involved. Interventions involved intraoperative use of PRP/PRF compared with controls without PRP/PRF. The primary outcome was occurrence of oronasal fistula; secondary outcomes were scar width, wound infection and postoperative bleeding with wound dehiscence. Study selection followed PRISMA guidelines, and the risk of bias was determined with the ROB-2 and ROBINS-I method of assessment. Seven studies met the required criterion and were qualitatively synthesized. Evidence suggested that PRP/PRF application was associated with a lower incidence of oronasal fistula and reduced scar width compared with controls. Additional benefits included accelerated wound healing and faster recovery. The use of autologous PRP was also reported to decrease the need for further surgical interventions. However, the certainty of evidence was limited due to small sample sizes and methodological heterogeneity. PRP and PRF show promising benefits in cleft lip and palate repair, particularly decreased fistula formation and reduced scar width. Nevertheless, current evidence is of low to very low certainty. Larger, well-designed randomized trials are required to validate the results obtained. Trial Registration: PROSPERO registration no. CRD420251032421.

Humans

The Effect of Slow Deep Breathing Relaxation Exercise on Pain and Anxiety Levels During and Post-Chest Tube Removal After CABG.

Chest tube removal after coronary artery bypass graft is frequently reported by patients as stressful and painful, highlighting the need for effective nonpharmacological interventions. Slow deep breathing relaxation exercises (SDBREs) may serve as a simple nursing strategy to reduce discomfort. In this study, we aimed to evaluate the effect of SDBRE on pain and anxiety during and after chest tube removal following coronary artery bypass grafting in Nablus hospitals. An experimental design was used with 80 patients recruited from 2 hospitals. Participants were randomly assigned to either an intervention group (n = 40) that practiced SDBRE or a control group (n = 40) that received standard care. Data were collected through a self-administered questionnaire, the Numeric Pain Scale, and the Visual Anxiety Scale. Data collection occurred from March to October 2024. The intervention group reported significantly lower pain scores during removal (M: 5.325 vs 7.125, P < .001) and after removal (P < .001). Anxiety scores were significantly lower both during and after removal (P < .001). Pain correlated with duration, with more complex operations and prolonged chest tube insertion linked to higher scores. SDBRE significantly reduced pain and anxiety during and after chest tube removal, supporting its integration into routine postoperative nursing care.

Humans

Effects of comprehensive oral care on nasogastric tube removal in long-term care residents with dysphagia: A multi-center randomized controlled trial.

Oral care is essential for residents in long-term care (LTC) facilities to reduce complications such as aspiration pneumonia. While routine oral hygiene is standard practice, comprehensive oral care (COC)-which includes facial and intraoral muscle massage, salivary gland stimulation, and oral moisturization-may further enhance swallowing function. However, evidence linking COC directly to nasogastric (NG) tube removal remains limited. This study evaluated the effectiveness of COC in facilitating NG tube removal and improving swallowing function among LTC residents with dysphagia. A multicenter, open-label randomized controlled trial was conducted across eight LTC facilities. The intervention group (n = 40) received daily one-on-one COC sessions lasting 30-40 min, while the control group (n = 37) received routine oral hygiene. Participants were followed for six months, with outcomes including NG tube removal, swallowing function, body weight, and pneumonia incidence. At six months, the COC group demonstrated a significantly higher NG tube removal rate, with eight participants achieving full oral intake (p = 0.005). Functional Oral Intake Scale scores were also significantly higher in the intervention group (p = 0.005). Time to NG tube removal ranged from 17 to 182 days. Under intention-to-treat principles, the NG tube removal rate remained significantly higher in the COC group (16.7%vs. 0%, p = 0.005). Competing risks analysis using the Aalen-Johansen estimator confirmed a 6-month cumulative incidence of NG tube removal of 14.6% in the COC group versus 0% in the control group (Gray's test: p = 0.005), with no significant between-group difference in mortality (p = 0.500). No significant differences were observed in body weight change or pneumonia incidence between groups. Among participants who successfully discontinued NG tube use, dementia was the most common underlying condition. These findings suggest that daily one-on-one COC is a feasible intervention in LTC settings and may improve swallowing function while facilitating NG tube removal in residents with dysphagia.

Humans

Intraocular Pressure Changes Following Intraluminal Stent Removal From the Paul Glaucoma Implant: A Systematic Review and Meta-Analysis.

PURPOSE: This study aims to systematically review and perform a single-arm meta-analysis to comprehensively evaluate the effect of removal of intraluminal stent from the Paul glaucoma implant (PGI) on intraocular pressure (IOP) changes and to summarize its long-term efficacy and safety. CLINICAL RELEVANCE: Glaucoma remains one of the leading global causes of irreversible vision loss, necessitating effective surgical management for refractory cases. Glaucoma drainage devices are critical for these complex forms, and intraluminal stent removal from the PGI serves as a key strategy to titrate aqueous outflow and optimize long-term IOP control. METHODS: A systematic review was conducted by searching EMBASE, Medline, and CENTRAL. The meta-analysis ultimately included 5 observational studies. The Risk of Bias in Nonrandomized Studies of Interventions (ROBINS-I) tool was used to assess the quality of the included studies. Continuous outcomes (eg, postremoval stent IOP reduction) were analyzed using the mean difference (MD) with 95% confidence intervals (CI); dichotomous outcomes (eg, hypotony incidence) were evaluated using pooled proportion with 95% CI. All meta-analyses employed a random-effects model. RESULTS: Our meta-analysis included 5 studies, involving a total of 283 eyes. The meta-analysis revealed that removal of the stent leads to a significant and immediate IOP reduction. The IOP reduction (immediate postremoval stent IOP minus preremoval stent IOP) was significant, with a pooled MD of -9.09 mm Hg IOP (MD = 9.09; 95% CI = [-11.77, -6.41]). In the preremoval stent high-IOP (>21 mm Hg) subgroup, the IOP reduction is -11.82 (95% CI = [-10.14, -13.51]). This reduction was significantly greater than the preremoval stent low-IOP (<21 mm Hg) subgroup, whose reduction is -6.66 mm Hg (95% CI = [-5.55, -7.77]). Regarding safety, the pooled proportion of clinically hypotony was low and highly consistent (I&#xb2; = 0.00%) at only 0.03 (95% CI = [0.00, 0.15]). CONCLUSIONS: Intraluminal stent removal from the PGI is an effective and safe IOP-lowering intervention. Its IOP reduction effect is significantly more pronounced in patients with preremoval stent high IOP, providing crucial clinical guidance for managing persistently high IOP after PGI implantation.

Humans

Effectiveness of high-power laser use in the removal of esthetic restorations: a systematic review.

This systematic review aimed to evaluate the effectiveness of high-power lasers in the removal of esthetic restorations compared with conventional methods. The review was conducted in accordance with the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) and registered in PROSPERO (registration number: CRD420251055736). A comprehensive electronic search was performed in MEDLINE, Scopus, Embase, Web of Science, and the Cochrane Library. Study selection, data extraction, and methodological quality assessment were independently performed by four reviewers using QUIN tool for in vitro studies. A total of 2.384 records were identified, of which 19 in vitro studies conducted on extracted human permanent teeth met the eligibility criteria and were included in the qualitative synthesis. The included studies evaluated different high-power laser systems, predominantly Er: YAG and Er, Cr: YSGG lasers, as well as CO&#x2082; lasers. Five studies were classified as high quality, whereas the remaining fourteen studies were classified as moderate quality. Available laboratory evidence suggests that laser-assisted techniques may represent a potential alternative approach for removing esthetic restorations, with advantages including conservative tissue removal, reduced damage to underlying tooth structures, and intrapulpal temperature increases within acceptable limits. The Er: YAG laser was the most frequently investigated system, with power settings ranging from 1.5 to 5.9&#xa0;W, showing particularly favorable laboratorial performance in the removal of lithium disilicate restorations, especially in thinner substrates. Within the limitations of the available evidence, high-power lasers appear to be a promising and minimally invasive alternative to conventional methods for the removal of esthetic restorations. However, the predominance of in vitro studies highlights the need for well-designed clinical trials to confirm these findings and support their clinical application.

Humans

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption

UV-based homogeneous disinfection process for removal of antibiotic resistance genes: Efficiency, mechanisms and influencing factors.

The proliferation and dissemination of antibiotic resistance genes (ARGs) in aquatic environments pose a serious threat to global public health. Ultraviolet-driven homogeneous advanced oxidation processes (UV-AOPs) represent a prospective suite of technologies for the efficient removal of ARGs. This review critically assesses recent advances in the application of UV-AOPs, specifically UV/hydrogen peroxide (UV/H2O2), UV/peracetic acid (UV/PAA), UV/persulfate (UV/PS), and UV/chlorine (UV/Cl), for the elimination of extracellular ARGs and intracellular ARGs. The underlying mechanisms involve direct ultraviolet-induced DNA damage, including pyrimidine dimer formation and strand breakage, as well as oxidation mediated by radicals such as hydroxyl radicals, sulfate radicals, carbon-centered radicals, and reactive chlorine species. The relative contribution of radical and non-radical pathways is strongly influenced by water chemistry and process conditions. We further expound on the critical operational and environmental factors governing ARG removal kinetics, including UV wavelength and fluence, oxidant type and dosage, ARG sequence characteristics, pH, ubiquitous anions, and dissolved organic matter, which collectively affect radical generation, quenching, and reaction microenvironments. Notably, for i-ARGs, UV-AOPs facilitate degradation not only through direct radical attack but also by disrupting cellular integrity and permeabilizing membranes, thereby enhancing the exposure of genetic materials to oxidative and photolytic damage. This review synthesizes current understanding to provide a mechanistic basis for the design and optimization of UV-AOP systems, highlighting their potential as effective barriers against the dissemination of antibiotic resistance in water reuse and purification scenarios.

Disinfection

Leveraging environmental applications and risks of coal gangue: A critical review on authigenic inorganic heavy metals, organic contaminants, and the removal of exogenetic contaminants.

Coal gangue (CG) as bulk solid waste has seriously threatened the ecosystem. Therefore, identifying the key risk drivers and exploring feasible disposal methods for CG are essential for developing a sustainable strategy. However, there is currently a lack of comprehensive information that balances the contamination risks with the valuable constituents present in CG, which hinders its full potential for sustainable use without negative environmental impacts. Given the complex composition and associated risks, we propose that addressing the critical properties related to contamination is crucial for the efficient utilization of CG. On this premise, we summarized several practical resource pathways (ecological multifunctional materials, extraction of rare elements, and soil additives) that are more favorable for sustainable development relative to conventional disposals. Meanwhile, we also propose that coupling disposals could intensely reduce CG's environmental footprints and capital costs. Consequently, regardless of the number of challenges to be solved, we believe the CG has broad application prospects, and we hope this review will promote the conversion of CG into an asset with lower ecological and social impacts.

Metals, Heavy

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

K-wire versus screw fixation in Scarf-Akin osteotomy for hallux valgus: A retrospective cohort study.

BACKGROUND: Retention of metal implants after Scarf-Akin osteotomy (SAO) may cause irritation and psychological discomfort, often necessitating a hardware removal procedure. This study aimed to introduce K-wire fixation, allowing for outpatient removal, and to compare it with screw fixation. METHODS: This retrospective study included 64 patients with hallux valgus, comprising 32 in the K-wire fixation group and 32 in the screw fixation group. Clinical outcomes were assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) score, visual analogue scale (VAS), and patient satisfaction. Radiographic parameters included hallux valgus angle(HVA), intermetatarsal angle(IMA), and distal metatarsal articular angle(DMAA). RESULTS: Both groups showed significant clinical and radiographic improvement (P&#x202f;<&#x202f;0.01). No significant between-group differences were observed in the other clinical or radiographic outcomes (P&#x202f;>&#x202f;0.05). Treatment costs were significantly lower in the K-wire group (P&#x202f;<&#x202f;0.001). CONCLUSIONS: K-wire fixation provides clinical and radiographic outcomes comparable to screw fixation, while avoiding the need for an additional procedure to remove the implant. LEVEL OF EVIDENCE: Level III.

Humans

Timing of carbetocin administration in vaginal deliveries: a double-blind, randomized controlled trial.

OBJECTIVES: This study aimed to compare the efficacy of administering carbetocin before vs. after placental delivery in preventing postpartum hemorrhage (PPH) in low-risk vaginal deliveries. METHODS: The randomized controlled trial was conducted at Kartal City Hospital, Istanbul, Turkey. A total of 160 primiparous women with uncomplicated pregnancies who underwent vaginal delivery were enrolled. Participants were randomly assigned to receive 100&#x202f;&#x3bc;g of carbetocin either before or after placental delivery. The primary outcome was the incidence of PPH. Secondary outcomes included the need for additional uterotonics, manual removal of the placenta with consequent antibiotic administration, blood transfusions, maternal adverse events, and changes in hemoglobin levels at baseline and 24&#x202f;h postpartum. RESULTS: The incidence of PPH was significantly lower in the carbetocin-before group than in the carbetocin-after group (p=0.015). The carbetocin-before group had a significantly lower mean hemoglobin drop compared to the carbetocin-after group (p<0.001). The need for additional uterotonics was significantly higher in the carbetocin-after group (p<0.001). Manual placenta removal and the need for antibiotics were more frequent in the carbetocin-before group (p=0.017). No significant differences in adverse maternal events were observed between the groups. CONCLUSIONS: Administering carbetocin before placental delivery significantly reduces the incidence of PPH, blood loss, and the need for additional uterotonics. However, the increased rate of manual placenta removal necessitates individualized risk-benefit assessment; pre-placental administration may be most advantageous in women at elevated risk for PPH, in whom the hemorrhagic benefit outweighs the risks associated with manual extraction.

Humans

Sacral Neuromodulation in the Management of Refractory Pediatric Lower Urinary Tract Dysfunction.

INTRODUCTION: Sacral neuromodulation is currently used in the pediatric patient population for refractory lower urinary tract dysfunction (LUTD). Evidence, however, is currently limited for institutional experiences of long-term outcomes for sacral neuromodulation in the pediatric patient population. OBJECTIVE: The objective of this study is to perform a retrospective review of a large multi-institutional cohort of pediatric patients that underwent sacral neuromodulation (SNM) for refractory LUTD, focused on rates of symptom improvement, quality of life, and bowel-bladder dysfunction measures following device implantation. Secondary objectives included assessing device complication rates and device removals due to failure or successful resolution of symptoms. METHODS: We performed a retrospective cohort study of pediatric patients at three children's hospitals that underwent SNM device implantation for refractory LUTD. Patients 4-18 years of age who were diagnosed with refractory LUTD and managed at a participating institution with follow-up were included. Outcomes were evaluated at baseline and post-operatively after two-stage device implantation at initial follow-up and annually until device removal or final follow-up. RESULTS: From 2010 to 2022, a total of 205 children underwent SNM procedures at three pediatric hospital centers. 204 patients completed the two-stage procedure for permanent device implantation with a median follow-up of 3.4 years (1.3, 4.9). One hundred seventy-eight patients reported partial (25%) or complete (54%) device response/symptom improvement by final follow-up. Comparison of patient-reported validated questionnaires completed at baseline and by final follow-up visit revealed significant improvement in median Pediatric Quality of Life Inventory (PedsQL) (p&#x2009;=&#x2009;0.004) and Vancouver Nonneurogenic Lower Urinary Tract Dysfunction/Dysfunctional Elimination Syndrome bowel-bladder dysfunction (BBD) scores (p&#x2009;<&#x2009;0.001). Of those with any device complication (n&#x2009;=&#x2009;43;21%), 19 patients required device revision, and 20 required complete device removal. Separately, twenty-eight patients (13%) underwent device removal due to resolution of symptoms or treatment success at a median period of 5 years (4,7). CONCLUSION: SNM use demonstrated a majority of patients reporting at least partial subjective symptom improvement following device implantation across multiple institutions by final follow-up. SNM is a viable treatment option for refractory LUTD in the pediatric patient if willing to undergo an invasive procedure and in which thorough counseling of risks and benefits has occurred.

Humans

Proteomic serum profiles before and after lipoprotein apheresis in patients with peripheral artery disease with ulceration.

INTRODUCTION: The efficacy of lipoprotein apheresis (LA) in peripheral arterial disease (PAD) has been primarily attributed to its anti-atherosclerotic effects through the adsorption of lipoproteins. However, the other potential effects of LA remain unknown. We evaluated changes in serum profiles before and after LA using a comprehensive analysis to explore the underlying mechanism. METHODS: Ten patients with leg ulcers were included from the LETS-PAD study, in which patients with lipoprotein-controlled PAD underwent LA. Serum samples collected at baseline and 1&#x2009;month after LA were analyzed for proteomic changes. RESULTS: Six patients exhibited ulcer epithelialization and skin perfusion pressure improvement. Proteomic analysis identified 2033 proteins. Fifty-five proteins showed significant differences. B-cell lymphoma protein-2 associated X (BAX) and C-X-C motif chemokine 10 (CXCL10) were downregulated. CONCLUSION: Serum BAX and CXCL10 levels significantly decreased after LA, which may be involved in the ulcer epithelialization mechanism of LA, which potentially acts through angiogenesis promotion.

Humans