Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “OPTICS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

The position of the crossed and uncrossed optic axons, and the non-optic axons, in the optic tract of the rat.

The position of the crossed and uncrossed optic axons, and of the non-optic axons, within the optic tract was determined in the adult hooded rat. Horseradish peroxidase histochemistry and lesion-induced degeneration of axonal profiles were independently used to study the position of the three relevant populations of axons within the optic tract. The boundaries of the optic tract are distinct at all but its caudomedial border, where it abuts the supra-optic commissures running parallel to the fibres of the optic tract. Labelling the crossed population of optic axons, or inducing their degeneration, both demonstrate a clear caudomedial border of the optic tract, although a number of optic axons stray out of the optic tract and course within the supra-optic commissures immediately caudomedial to the tract. The uncrossed optic axons are, as a population, positioned relatively deep in the optic tract, towards its dorsal border. A few occur at further ventral positions, but their density is greatly reduced there. There is also a very thin region along the dorsalmost edge of the optic tract free of uncrossed optic axons. The relative position of the uncrossed to the crossed optic axons is discussed in the context of the mammalian optic tract as a chronological map: spatial position in the tract may reflect temporal order of axonal arrival during early development. A large population of non-optic axons belonging to Gudden's commissure courses within the boundaries of the optic tract at a relatively ventral position. They are most frequent caudomedially, and are absent rostrolaterally. Hence, axons of the optic tract and Gudden's commissure are substantially intermingled in the caudomedial half of the optic tract. These non-optic axons greatly outnumber the uncrossed optic axons, and will consequently distort counts of uncrossed optic axons based on intact profiles that remain after removal of the opposite eye. However, they are still a minority in comparison to the crossed optic axons in this region.

Animals↗

Optic nerve regeneration after intravitreal peripheral nerve implants: trajectories of axons regrowing through the optic chiasm into the optic tracts.

We have studied axon regeneration through the optic chiasm of adult rats 30 days after prechiasmatic intracranial optic nerve crush and serial intravitreal sciatic nerve grafting on day 0 and 14 post-lesion. The experiments comprised three groups of treated rats and three groups of controls. All treated animals received intravitreal grafts either into the left eye after both left sided (unilateral) and bilateral optic nerve transection, or into both eyes after bilateral optic nerve transection. Control eyes were all sham grafted on day 0 and 14 post-lesion, and the optic nerves either unlesioned, or crushed unilaterally or bilaterally. No regeneration through the chiasm was seen in any of the lesioned control optic nerves. In all experimental groups, large numbers of axons regenerated across the optic nerve lesions ipsilateral to the grafted eyes, traversed the short distal segment of the optic nerve and invaded the chiasm without deflection. Regeneration was correlated with the absence of the mesodermal components in the scar. In all cases, axon regrowth through the chiasm appeared to establish a major crossed and a minor uncrossed projection into both optic tracts, with some aberrant growth into the contralateral optic nerve. Axons preferentially regenerated within the degenerating trajectories from their own eye, through fragmented myelin and axonal debris, and reactive astrocytes, oligodendrocytes, microglia and macrophages. In bilaterally lesioned animals, no regeneration was detected in the optic nerve of the unimplanted eye. Although astrocytes became reactive and their processes proliferated, the architecture of their intrafascicular processes was little perturbed after optic nerve transection within either the distal optic nerve segment or the chiasm. The re-establishment of a comparatively normal pattern of passage through the chiasm by regenerating axons in the adult might therefore be organised by this relatively immutable scaffold of astrocyte processes. Binocular interactions between regenerating axons from both nerves (after bilateral optic nerve transection and intravitreal grafting), and between regenerating axons and the intact transchiasmatic projections from the unlesioned eye (after unilateral optic nerve lesions and after ipsilateral grafting) may not be important in establishing the divergent trajectories, since regenerating axons behave similarly in the presence and absence of an intact projection from the other eye.

Age Factors↗

Correlation between optic disc atrophy and aetiology: anterior ischaemic optic neuropathy vs optic neuritis.

BACKGROUND: The morphologic features of swollen disc in the acute stage of optic neuritis and anterior ischaemic optic neuropathy (AION) have been extensively investigated in contrast to the morphologic features of optic disc atrophy after these events. OBJECTIVE: : A prospective study to evaluate the morphologic features of optic disc atrophy 6 months or more after optic neuritis and nonarteritic AION. PATIENTS AND METHODS: A total of 35 optic discs after nonarteritic AION (n=27) and 24 after optic neuritis (n=19) in otherwise healthy subjects have been evaluated by direct fundoscopic examination with a +90 diopters lens and optic disc photography. The average age of patients at the onset of AION was 57.8 years (range: 38-80) and at the onset of optic neuritis was 32.6 (range: 19-46). The female:male ratio was 18 : 17 in the former and 15 : 9 in the latter. The evaluated parameters included: degree of rim pallor (0 to +3), location of rim pallor, height of rim above the retina, depth and width of cup, peripapillary retinal artery to vein (A : V) ratio, and peripapillary pigment epithelial atrophy. A comparison was made also with 17 age-matched normal discs of 17 patients. Statistical significance was calculated with chi(2) and Fisher's exact test. RESULTS: Most of the discs after AION were paler (+2: 70%, +3: 26%) than after optic neuritis (normal colour: 8%, +1: 58%, P< or =0.007). Rim segmental involvement after AION was usually either superior 'altitudinal' (53%) or inferior 'altitudinal' (29%), whereas after optic neuritis, it was usually either temporal-central (papillomacular) (42%) or diffuse temporal (42%, P<0.0001). Discs had lower A : V ratio (1 : 3, 40%) after AION compared with optic neuritis (1 : 3, 8%) (P=0.007). There were no significant differences between the two groups in height of the rim, cupping, and peripapillary atrophy. CONCLUSIONS: : A combination of the degree of rim pallor, location of rim pallor, and A : V ratio may be of value in assessing the aetiology of optic disc atrophy when no previous clinical data are available and a compressive lesion has been ruled out.

Acute Disease↗

Diameter of the optic nerve in idiopathic optic neuritis and in anterior ischemic optic neuropathy.

PURPOSE: There is considerable overlap in the clinical profile of patients with idiopathic optic neuritis (ON) and anterior ischemic optic neuropathy (AION). We tested the hypothesis that the retrobulbar diameter of the optic nerve may be a criterion for the differential diagnosis between ON and AION. METHODS: The diameter of the optic nerve was measured by B-scan ultrasonography with the eye in an abducted position. Only patients with a unilateral optic neuropathy were included, 16 ON patients (mean age 24 years, 5 with and 11 without disc swelling) and 9 patients with AION (mean age 72 years). As controls for the ON patients 10 young normal subjects (mean age 25 years) and as controls for the AION patients 10 elderly subjects with eye problems not related to the optic nerve (mean age 76 years) were examined. RESULTS: In the ON patients with disc swelling the diameter of the optic nerve was 5.4 +/- 0.5 mm in the affected and 3.0 +/- 0.3 mm in the unaffected side. This difference was significant (Wilcoxon-test, p = 0.043). In the ON patients without disc swelling the diameter of the optic nerve was 4.4 +/- 0.4 mm in the affected and 3.0 +/- 0.3 mm in the unaffected side. This difference was significant (Wilcoxon-test, p = 0.003). In the AION patients the diameter of the optic nerve was 3.0 +/- 0.3 mm on the affected and 2.8 +/- 0.4 mm on the unaffected side. This difference was not significant (Wilcoxon-test, p = 0.093). Comparing the optic nerves with ON and AION to those of the controls, the diameter was significantly enlarged in the nerves with ON and normal in the nerves with AION (one factor repeated ANOVA). CONCLUSION: The diameter of the optic nerve is increased in ON without disc swelling and even more so in ON with disc swelling. The enlargement is probably due to edema of the nerve itself, not the surrounding subarachnoidal space. In AION, the diameter of the optic nerve is normal. Measuring the diameter of the optic nerve by B-scan ultrasonography is particularly useful in the differential diagnosis between ON with disc swelling and AION.

Adolescent↗

Does optic disc appearance distinguish ischemic optic neuropathy from optic neuritis?

OBJECTIVE: To determine whether characteristics of optic nerve swelling assist in distinguishing between optic neuritis and anterior ischemic optic neuropathy. METHOD: Optic nerve stereophotograph review by masked observers. RESULTS: Altitudinal swelling, pallor, arterial attenuation, and hemorrhage are found more commonly in anterior ischemic optic neuropathy than in optic neuritis. CONCLUSION: Optic disc appearance does help to distinguish anterior ischemic optic neuropathy from optic neuritis, although there are overlapping features.

Acute Disease↗

Optical trapping of a spherically symmetric sphere in the ray-optics regime: a model for optical tweezers upon cells.

Since their invention in 1986, optical tweezers have become a popular manipulation and force measurement tool in cellular and molecular biology. However, until recently there has not been a sophisticated model for optical tweezers on trapping cells in the ray-optics regime. We present a model for optical tweezers to calculate the optical force upon a spherically symmetric multilayer sphere representing a common biological cell. A numerical simulation of this model shows that not only is the magnitude of the optical force upon a Chinese hamster ovary cell significantly three times smaller than that upon a polystyrene bead of the same size, but the distribution of the optical force upon a cell is also much different from that upon a uniform particle, and there is a 30% difference in the optical trapping stiffness of these two cases. Furthermore, under a small variant condition for the refractive indices of any adjacent layers of the sphere, this model provides a simple approximation to calculate the optical force and the stiffness of an optical tweezers system.

Animals↗

[Comparison of scanning laser polarimetry, optical coherence tomography 1 and Stratus optical coherence tomography for the detection of axonal loss in band atrophy of the optic nerve].

PURPOSE: To compare the abilitiy of scanning laser polarimetry (GDx), optical coherence tomography (OCT) 1 and Stratus- optical coherence tomography to discriminate between healthy eyes and eyes with band atrophy of the optic nerve and temporal hemianopsia. METHODS: Twenty-three eyes with band atrophy of the optic nerve and 23 eyes from healthy subjects were included in this observational prospective case-control study. All eyes underwent retinal nerve fiber layer (RNFL) thickness analysis using GDx, optical coherence tomography-1 and Stratus-optical coherence tomography. Mean values obtained with each equipment were compared between band atrophy and normal eyes. Receiver operating characteristic (ROC) curves and sensitivities at fixed specificities (80% e 95%) were calculated for each parameter calculated with each equipment and compared. RESULTS: When compared with healthy subjects, the parameters corresponding to the global average as well as each of the four quadrant retinal nerve fiber layer thickness in eyes with band atrophy were significantly smaller (p<0.05), than in normal eyes, with the exception of GDx's temporal thickness parameter. Comparison of the areas under ROC curves (AUCs) of the parameters from the three equipments revealed significantly greater values for the Stratus-OCT when compared to the OCT-1 in the global average and in the temporal quadrant thickness measurement. Stratus-OCT was significantly more sensitive than GDx in the global average as well as in the temporal, nasal and inferior quadrant. OCT-1 was superior to GDx only in the temporal quadrant. All three equipments revealed a similar ability to identify retinal nerve fiber layer reduction in the superior quadrant. CONCLUSIONS: The Stratus OCT showed the best ability to discriminate between eyes with band atrophy of the optic nerve and healthy eyes although all three equipments were able do identify most of the abnormal eyes. OCT-1 was inferior to Stratus-OCT and superior do GDx in the temporal quadrant. Although GDx was able identify some abnormality in most studied eyes, the equipment showed poor sensitivity in the detection of axonal loss in the nasal and temporal aspect of the optic disc and should be used with caution in neuro-ophthalmic diseases that cause retinal nerve fiber layer loss in those areas of the optic disc.

Axons↗

Evaluation of the influence of tilt of optic disc on the measurement of optic disc variables obtained by optical coherence tomography and confocal scanning laser ophthalmoscopy.

PURPOSE: To evaluate the relationship between optic disc variables measured by confocal scanning laser ophthalmoscopy (CSLO) and optical coherence tomography (OCT). METHODS: Fifty-one eyes in 27 non-glaucomatous patients were scanned using a CSLO-TopSStrade mark and an OCT-OCT 3000trade mark. The relationship between the following four optic disc variables-disc area (DA), cup area (CA), neuroretinal rim area (NRRA), and cup-disc area ratio (CDAR)-measured by CSLO and OCT were evaluated, and the relationship between these measurements and optic disc tilt was assessed. Horizontal (HD) and vertical diameters (VD) of the optic disc were measured from disc photographs, and by CSLO and OCT, and ratios (HD/VD) were then compared. RESULTS: There was a good correlation in DA, CA, and CDAR except NRRA between OCT and CSLO measurements. In eyes with a tilt >/=4 degrees, DA and NRRA were measured larger, and CDAR and CA were measured smaller by OCT than by CSLO. However, in the eyes with a tilt of <4 degrees, no significant differences in measurement of disc variables were observed for the two measurement systems. HD/VD measured from disc photographs was well correlated with those determined by CSLO (r = 0.741, P < 0.0001), however, it correlated poorly with those measured by OCT in whole study eyes (r = 0.410, P = 0.008) and in eyes tilted by >/=4 degrees, respectively (P = 0.280). CONCLUSIONS: Although CSLO and OCT measurements of the optic disc are highly correlated, discrepancy becomes prominent in eyes with a disc tilted >/=4 degrees. Therefore, analysis of the optic nerve head by OCT must be cautiously interpreted in eyes with a highly tilted disc.

Adolescent↗

[Revascularization decompression of the optic nerve: a new surgery of the optic nerve in progressive glaucomatous optic neuropathy].

A new operation on the optic nerve scleral canal, revascularization compression of the optic nerve, was carried out in 21 patients (21 eyes) in order to improve the visual functions and stabilize the glaucomatous process. The operation combines the advantages of decompression of the optic nerve by dissection of the posterior scleral ring with creation of an additional source of blood supply to the optic nerve from the myovascular bundle of the internal rectal muscle. Good functional effect and notable improvement of hemoperfusion of the optic nerve and retina were attained (period of observation up to 2 years). The degree of visual field extension correlated with the degree of increase in hemoperfusion values. Comparative analysis showed a higher functional efficiency of revascularization decompression of the optic nerve in comparison with optic nerve decompression, which is due to a more essential improvement of ocular hemoperfusion.

Aged↗

Visual function 5 years after optic neuritis: experience of the Optic Neuritis Treatment Trial. The Optic Neuritis Study Group.

OBJECTIVE: To assess the 5-year visual course, including the incidence of recurrent optic neuritis, in 454 patients enrolled in the Optic Neuritis Treatment Trial. METHODS: Five-year follow-up vision testing, which included measures of visual acuity, contrast sensitivity, visual field, and color vision, was completed for 397 (87%) of the 454 patients. RESULTS: Visual function test results in the eyes that experienced optic neuritis at study enrollment (affected eyes) were normal or only slightly abnormal after 5 years in most patients; the results did not significantly differ by treatment group (P=.37 for visual acuity). The visual acuity in the affected eyes was 20/25 or better in 87%, 20/25 to 20/40 in 7%, 20/50 to 20/190 in 3%, and 20/200 or worse in 3%. The recurrence of optic neuritis in either eye occurred in 28% of the patients and was more frequent in patients with multiple sclerosis (P=.001) and in patients without multiple sclerosis who were in the prednisone treatment group (P=.004). Most eyes with a recurrence retained normal or almost normal visual function. CONCLUSIONS: Most patients retained good to excellent vision in the 5 years following an attack of optic neuritis, even if the optic neuritis recurred. Recurrences were more frequent in patients with multiple sclerosis and in those treated with oral prednisone alone. The completion of the 5-year follow-up by the Optic Neuritis Treatment Trial cohort has not altered our management recommendations based on the results we reported earlier.

Administration, Oral↗

Diffractive optical elements based on Fourier optical techniques: a new class of optics for extreme ultraviolet and soft x-ray wavelengths.

A diffractive optical element, based on Fourier optics techniques, for use in extreme ultraviolet/soft x-ray experiments has been fabricated and demonstrated. This diffractive optical element, when illuminated by a uniform plane wave, will produce two symmetric off-axis first-order foci suitable for interferometric experiments. The efficiency of this optical element and its use in direct interferometric determination of optical constants are also discussed. Its use in direct interferometric determination of optical constants is also referenced. Its use opens a new era in the use of sophisticated optical techniques at short wavelengths.

Journal Article↗

Concept of a miniature optical spectrometer using integrated optical and micro-optical components.

We describe the concept of a super compact diffractive imaging spectrometer, with optical components a few millimeters across in all dimensions, capable of detecting optical fluorescence spectra within the entire visible spectral range from 400 nm to 700 nm with resolution of the order of 2 nm. In addition, the proposed spectrometer is capable of working simultaneously with multiple, up to 35, independent input optical channels. A specially designed diffractive optical element integrated with a planar optical waveguide is the key component of the proposed device. In the preliminary experimental tests, a uniform waveguide grating with a microlens was used to mimic operation of the diffractive optical element. A microspectrometer with optical components measured below 1 cm in all dimensions covers the spectral range from 450 nm to 650 nm and shows a spectral resolution of 0.5 nm at wavelengths close to 514 nm and 633 nm.

Journal Article↗

Absorption spectrometry by narrowband light in optically saturated and optically pumped collision and Doppler broadened gaseous media under arbitrary optical thickness conditions.

This work examines absorption spectrometry by narrowband light in gaseous media with arbitrary optical thickness when the light induces optical saturation or optical pumping. Two quantities are defined: the observed absorbance, A(obs), and the true absorbance, A(true). The former is the absorbance that is measured under the existing conditions, whereas the latter represents the absorbance one would measure if the light acted solely as a probe of the populations of the various levels, and it is therefore directly proportional to the concentration or density of absorbers. A general integral equation for the propagation of light in media of arbitrary optical thickness in which the light influences the populations of the levels involved is derived. This expression is transcendental in the observed absorbance and cannot be solved analytically. It is shown that an analytical expression can be derived by investigating the inverse relationship, i.e., A(true) = f(A(obs)). Inasmuch as collision and Doppler broadened media react differently to optical saturation, they are considered separately. It is shown that a nonlinear response results if the medium is optically saturated (or pumped) and not optically thin. Expressions for the error introduced if the technique of standard additions is uncritically applied to such a system are derived.

Journal Article↗

Baseline visual field profile of optic neuritis. The experience of the optic neuritis treatment trial. Optic Neuritis Study Group.

The purpose of the present study was to determine the baseline visual field characteristics in 448 patients with acute optic neuritis who were entered into the Optic Neuritis Treatment Trial. The severity and pattern of visual field loss in both the affected and fellow eyes were classified. For affected eyes, diffuse visual field loss was present in 48.2% of eyes, central or centrocecal scotoma was present in 8.3% of eyes, altitudinal or other nerve-fiber bundle-type defects were present in 20.1% of eyes, and a variety of other defects were present in 23.4% of eyes. Visual field involvement was present in the fellow eye at baseline in 308 (68.8%) of the 448 patients. Evidence of a chiasmal or retrochiasmal visual field defect was present in 2.9% of the patients. Since a wide variety of visual field defects can occur with an acute attack of optic neuritis, the pattern of visual field loss is of limited utility in distinguishing optic neuritis from ischemic optic neuropathy and other optic nerve disorders. Asymptomatic visual field defects in the fellow eye are common.

Acute Disease↗

Impulse blockade by intraocular tetrodotoxin during optic regeneration in goldfish: HRP-EM evidence that the formation of normal numbers of optic synapses and the elimination of exuberant optic fibers is activity independent.

Optic fibers and synapses labeled with HRP were counted in the primary optic innervation layer of tectum after continuously blocking visual impulse activity with TTX during regeneration. Normal numbers of optic and nonoptic fibers and synapses were found at both 30 and 60 d, and key ultrastructural features of optic afferents such as fiber fasciculation, myelination, terminal clustering, synaptogenesis onto different classes of postsynaptic targets and general morphology were not notably affected by impulse blockade. These findings indicate that during regeneration the normal proliferation and elimination of optic fibers and the formation of normal numbers of optic synapses are not regulated by activity and are consistent with a pattern formation role for impulse activity rather than a trophic one.

Animals↗

Optic nerve head circulation in nonarteritic anterior ischemic optic neuropathy and optic neuritis.

PURPOSE: To quantify optic nerve head circulatory abnormalities in patients with unilateral nonarteritic anterior ischemic optic neuropathy (NAION) or optic neuritis (ON), and to assess the potential of such measurements to differentiate NAION from ON. DESIGN: Prospective, cross-sectional, observational study. PARTICIPANTS: Thirty consecutive patients with unilateral NAION, 22 consecutive patients with unilateral ON, and 50 healthy control subjects. METHODS: All subjects underwent a complete neuro-ophthalmologic evaluation. The widths of Doppler-broadened frequency spectra, which are directly proportional to the speed of blood cells flowing through the capillaries of the optic nerve head, were measured at multiple sites in both eyes of each subject. The variation of Doppler broadening (DB) with age was determined in the control subjects. Doppler broadening values in the patients were compared between similar sites in affected and contralateral eyes, and between both affected and contralateral eyes and the age-adjusted values determined in the control subjects. MAIN OUTCOME MEASURES: The differences in DB between (1) the affected and contralateral eyes of the patients, (2) the patients and the control subjects, and (3) the patients with NAION and those with ON. RESULTS: In NAION, DB was decreased at both temporal (-20.2% and -18.5%) and nasal (-12.8% and -12.4%) sites of the nerve head in affected eyes compared with contralateral eyes or eyes of control subjects. In ON, DB was also decreased at temporal sites (-11.3% and -9.2%) in affected eyes compared with contralateral or control eyes. At nasal sites, there were no significant differences in DB in affected eyes of ON patients compared with contralateral or control eyes. The DB decreases were significantly greater in NAION patients than in ON patients. CONCLUSIONS: Optic nerve head circulatory abnormalities are present in patients with NAION or ON. This is the first demonstration of such abnormalities in ON, a finding consistent with the recent attention given to the phenomenon of axonal loss in this disease. Although there are differences in the circulatory abnormalities between the 2 diseases that provide insights into the pathophysiological mechanisms at play, they are not large enough to enable the clinician to distinguish between ON and NAION in an individual patient.

Adolescent↗

Optical characteristics of a refractive optical attenuator with respect to the wedge angles of a silicon optical leaker.

We design, fabricate, and characterize the micromachined refractive variable optical attenuator (VOA) with a wedge-shaped silicon optical leaker (SOL). The vertical structures of the VOA device can be simply fabricated by deep reactive ion etching with no sidewall metallization, and the 8 degrees angled fibers are employed for a high return loss even in air-ambient conditions. The SOL successively transmits and refracts part of the incident light far outside the acceptance angle of the output fiber, showing an effective optical attenuation. The fabricated VOA gives high optical performances, such as a response time of 6 ms, a return loss of 39 dB, an insertion loss of 0.6 dB, an attenuation range of 43 dB, and a polarization-dependent loss (PDL) of a 10% attenuation level, including a wavelength-dependent loss. The optical characteristics of the VOA are also theoretically investigated with respect to the wedge angles of the SOL. The experimental characteristics are in good agreement with the theoretical values calculated, considering light scattered from the endface of an optical fiber and sidewall of the SOL. The PDL estimation was confirmed especially to sufficiently explain the fundamental characteristic of the PDL for the refractive VOA.

Journal Article↗

10 Gbit/s all-optical non-return to zero-return-to-zero data format conversion based on a backward dark-optical-comb injected semiconductor optical amplifier.

By using a semiconductor optical amplifier backward injected by a dark-optical-comb pulse train at 10 GHz, we demonstrate a 10 Gbit/s all-optical nonreturn-to-zero (NRZ) to return-to-zero (RZ) format conversion of an incoming optical pseudorandom binary sequence (PRBS) data stream. Both the polarity and the wavelength of data are conserved during format conversion. Without any pre-amplification, the extinction ratio of degraded optical NRZ PRBS data is greatly improved from 7.13 to 13.6 dB after NRZ-to-RZ conversion. An ultralow bit-error rate of 10(-12) at a data rate as high as 10 Gbits/s is obtained with a received optical power of -18.3 dBm. The converted RZ PRBS data exhibit a negative power penalty of >3.7 dB compared with the NRZ PRBS data at a bit-error rate of 10(-12).

Journal Article↗