Search PubMedSearch

SEARCH · Search PubMed

Results for “Mitral annular motion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

6 recordsLinked to original sources

Cine-derived mitral annular relaxation velocity for detection of preclinical left ventricular diastolic dysfunction.

OBJECTIVES: Imaging diastolic dysfunction in pre-clinical heart failure (HF) is challenging. We evaluated a novel cardiac MRI (CMR) biomarker, CMR e-prime (CMR-MARV), in patients at risk of HF. METHODS: In this substudy of the PARABLE trial (NCT04687111), 236 patients (71.6&#xa0;&#xb1;&#xa0;7.7&#xa0;years, 61.6% male) fulfilling trial-defined ALVDD citeria underwent CMR with measurement of mitral annular relaxation velocity (CMR-MARV) at four mitral annular anchor points. Diastolic strain rates from FT were also assessed. Twenty-five age- and sex-matched controls were included (73.8&#xa0;&#xb1;&#xa0;3.1&#xa0;years, 52% male). Group differences were tested with t-tests, diagnostic accuracy with ROC analysis, and predictors of diastolic dysfunction with adjusted logistic regression. RESULTS: Compared with controls, patients had significantly higher indexed maximal left atrial volume (LAVimax), LV end-diastolic and end-systolic volumes, and LV mass (all p&#xa0;<&#xa0;0.001). Of FT variables, only peak diastolic longitudinal velocity differed between groups (p&#xa0;<&#xa0;0.001). In multivariate models, CMR-MARV correlated with radial, circumferential, and longitudinal diastolic strain rates, radial and longitudinal diastolic velocities (all p&#xa0;<&#xa0;0.001), echocardiographic e' (r&#xa0;=&#xa0;0.20, p&#xa0;=&#xa0;0.007), LV mass (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), LAVimax (r&#xa0;=&#xa0;-0.18, p&#xa0;=&#xa0;0.008), and NT-proBNP (r&#xa0;=&#xa0;-0.30, p&#xa0;<&#xa0;0.0001). LAVimax and CMR-MARV were strongly independently associated with ALVDD (AUC 0.89 and 0.76, respectively; p&#xa0;<&#xa0;0.0001). A combined model (LAVimax + CMR-MARV) achieved excellent discrimination (AUC 0.91, 95% CI 0.86-0.97, p&#xa0;<&#xa0;0.0001). Independent predictors included LAVimax, CMR-MARV, and peak diastolic longitudinal velocity (all p&#xa0;<&#xa0;0.001). CONCLUSION: CMR-MARV provides a simple cine-derived measure of longitudinal relaxation that correlates with established structural and biochemical markers of diastolic burden. Within an at-risk population, it offers incremental functional information beyond conventional parameters and may support multiparametric CMR phenotyping of preclinical diastolic dysfunction.

Aged

Adding Rib Mobilization to Diaphragm Release Techniques in Patients With Non-Specific Neck Pain: Randomized Controlled Trial.

BACKGROUND: Non-specific neck pain (NSNP) is a frequent issue that can negatively affect both mobility and function. Recently, there has been growing interest in newer therapeutic approaches, including rib mobilization and diaphragm release techniques, as potential ways to address NSNP and support better outcomes for those affected. PURPOSE: To find out the immediate effects of how (DRT) combined with (RMT) affects the level of pain and the extent to which patients' functional abilities are improved in cases of NSNP. METHODS: For this prospective RCT, 96 participants aged 20 to 45&#xa0;years were randomly assigned to one of three equal groups based on their pain score (VAS). Group B engaged in (DRT) for 40&#xa0;minutes, three times weekly for 8&#xa0;weeks, in contrast to Group A, which got both RMT combined with DRT. Group C (active control) received advice and some exercises. Measurements were collected before and after the intervention; the primary outcomes included pain severity, evaluated using a visual analog scale (VAS); active neck range of motion (ROM), measured with a cervical range of motion (CROM) device; and neck flexion endurance. Additionally, the secondary outcome of neck-related disability was assessed using the Neck Disability Index (NDI). RESULTS: No statistically significant difference was identified among the three groups at baseline; nevertheless, a treatment effect emerged after 8&#xa0;weeks (p&#xa0;=&#xa0;0.001 and f-value&#xa0;=&#xa0;4.15, &#x19e;2&#xa0;=&#xa0;0.306). A statistically significant time-treatment interaction was seen when comparing the pre- and post-treatment periods in groups A and B (p&#xa0;=&#xa0;0.001, f-value&#xa0;=&#xa0;3.16, &#x19e;2&#xa0;=&#xa0;0.251). CONCLUSION: The addition of rib mobilization to diaphragm release techniques in patients with non-specific neck pain resulted in statistically significant improvements in pain intensity, cervical flexion, right lateral rotation, left lateral rotation, right rotation, and neck flexor endurance, with moderate to large effect sizes for pain reduction and cervical motion. However, no statistically significant differences were observed between groups for cervical extension, left rotation, or the Neck Disability Index (NDI), and only a marginal clinical improvement in NDI was noted in Group A. The observed benefits in the combined intervention group may not be attributable solely to rib mobilization. The increased treatment complexity and greater therapist interaction inherent in the combined approach could also have influenced the outcomes. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT07133646.

Humans

Effects of Transcranial Direct Current Stimulation and Individualized Physical Therapy on Pain and Function in Individuals With Chronic Knee Pain: A Pilot Study.

BACKGROUND AND PURPOSE: Noninvasive brain stimulation is a promising neuromodulatory intervention for chronic pain. This study aimed to determine the impact that transcranial direct current stimulation (tDCS) in combination with individualized physical therapy (PT) has on pain and function in individuals with chronic knee pain. METHODS: This study was a preliminary pragmatic, triple-blinded, randomized, and sham-controlled clinical trial performed in an outpatient orthopedic physical therapy clinic. Participants participated in 5 sessions of active or sham tDCS followed by individualized PT intervention. Pain outcomes included the Numeric Pain Rating Scale, Movement-Evoked Pain, pressure pain thresholds (PPT), and the Central Sensitization Inventory. Functional outcomes included the 2-minute walk test, 5-time sit-to-stand test, quadriceps strength, knee range of motion, Patient Specific Functional Scale, and the Lower Extremity Functional Scale. RESULTS: Thirty participants with chronic knee pain completed the study. There were no significant differences observed for primary patient-centered pain and functional outcomes. For secondary outcomes, the active tDCS group had a significant effect (p&#xa0;<&#xa0;0.05) on percent change in lateral joint line PPT and a significant multivariate effect of group on PPT change scores for 3-site and 5-site clusters (p&#xa0;<&#xa0;0.05). Exploratory responder analyses demonstrated that the active tDCS group was 12.8 times more likely to achieve the minimum detectable change in quadriceps strength improvement compared with the sham tDCS group (p&#xa0;<&#xa0;0.05). DISCUSSION: There were no significant between-group differences for primary pain and functional outcomes. However, the active tDCS group showed improvements in pain sensitivity, as measured by PPT, and quadriceps strength, which were superior to those seen in the sham tDCS group. These preliminary findings provide insight into possible mechanisms of tDCS in addressing pain as opposed to efficacy. Given that there were no clear between-group differences in patient-centered outcomes, there is insufficient evidence for routine tDCS use for chronic knee pain. TRIAL REGISTRATION: NCT06132412.

Humans

Impact on analgesia, diaphragmatic function, and recovery between erector spinae plane block versus superior trunk block in arthroscopic shoulder surgery: a randomized controlled trial.

BACKGROUND: Effective analgesia and preservation of diaphragmatic function are key considerations in analgesia for shoulder surgery. The superior trunk block provides analgesia with reduced phrenic nerve involvement, while the erector spinae plane block offers minimal impact on diaphragm motion. This randomized controlled trial compared the analgesic efficacy, impact on diaphragmatic motion, and postoperative recovery between the two blocks. METHODS: Sixty patients undergoing arthroscopic shoulder surgery were randomized to receive either erector spinae plane block or superior trunk block. Primary outcomes were postoperative VAS and changes in diaphragmatic excursion. Secondary outcomes included Quality of Recovery-15 (QoR-15) scores, morphine-equivalent consumption, and the handgrip strength motor blockade. RESULTS: The superior trunk block resulted in significantly lower dynamic VAS at 1-h postoperatively (0.1 [0.0, 0.2] vs. 5.7 [4.0, 7.6]; p&#x2009;<&#x2009;0.001) and reduced 24-h morphine consumption (7.8 [2.5, 15.0] mg vs. 12.7 [7.5, 17.3] mg; p&#x2009;=&#x2009;0.038) compared to the erector spinae plane block. However, diaphragmatic excursion was better preserved in the erector spinae plane block group (8.37% &#xb1; 20.7% vs. -20.09% &#xb1; 22.2%; p&#x2009;<&#x2009;0.001), with a lower incidence of partial hemidiaphragm paresis (3.3% vs. 46.7%; p&#x2009;<&#x2009;0.001). At 24&#x2009;h postoperatively, QoR-15 scores were higher in the superior trunk block group (p&#x2009;=&#x2009;0.047), and no patient in either group developed handgrip motor blockade. CONCLUSIONS: Superior trunk block offers superior early postoperative analgesia and better overall recovery, while erector spinae plane block minimizes diaphragmatic impairment. However, the erector spinae plane block may represent an option only in carefully selected patients at high respiratory risk, acknowledging its significantly poorer early analgesic profile.

Humans

Evaluation of Physical and Mental Workload and Transfusion Time in Trauma Resuscitation.

BACKGROUND: Trauma resuscitation is time sensitive and complex. Whole blood (WB) and blood components are standard treatments for trauma related hemorrhage, yet their nursing workload and transfusion time have not been well evaluated. PURPOSE: To assess feasibility of a simulation-based crossover trial and obtain preliminary estimates comparing nursing workload and transfusion completion time between WB and blood component administration. METHODS: A randomized crossover pilot study using in situ simulation was conducted with experienced trauma nurses. Time-motion analysis measured transfusion completion time, and the National Aeronautical and Space Administration Task Load Index assessed workload domains. RESULTS: Strong feasibility was demonstrated across recruitment, retention, adherence, and completion. WB was associated with significantly shorter transfusion time, lower overall workload and mental demand, less effort, and better perceived performance. CONCLUSIONS: These findings support the feasibility and justify a fully powered trial. WB may improve resuscitation efficiency and reduce cognitive burden, with potential implications for patient outcomes and nursing workflow.

Humans

AI-driven snapshot hyperspectral imaging for on-line sorting systems in food industry: From real-time sensing to intelligent decision-making.

High-throughput food sorting requires rapid, non-destructive detection of external defects, foreign materials, and internal quality attributes in heterogeneous food matrices. Conventional scanning hyperspectral imaging may suffer from motion-induced spatial-spectral mismatches, whereas snapshot hyperspectral imaging (S-HSI) captures spectral images within a single integration time. However, its advantage is limited by trade-offs in resolution, signal-to-noise ratio (SNR), reconstruction uncertainty, and calibration stability, which are further amplified by variable tissue structure, surface reflection, moisture, and fat distribution in foods. This review critically examines artificial intelligence (AI)-driven S-HSI for on-line food sorting within a sensing-representation-decision-execution framework. Compact architectures are compared according to their physical constraints, food-sorting suitability, and ability to support mapping between spectral responses and physicochemical quality attributes. AI strategies are reviewed for spectral reconstruction, image restoration, spatial-spectral representation, band selection, uncertainty-aware decision-making, and edge implementation. AI can partially compensate for snapshot-specific limitations, but current evidence remains largely limited to laboratory or prototype studies. Future work should link system performance to food safety and quality outcomes by reporting throughput, decision latency, calibration drift, missed-detection risk, false-rejection cost, and closed-loop sorting success.

Hyperspectral Imaging