New trends in biosensors for health care.
Explore the source record for details and available documents.
SEARCH · Search PubMed
Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Chip devices were introduced in chemistry and molecular biology to improve the read-out of information from molecular systems by efficient analytical procedures and to organize automated experiments. Biochips and chip reactor systems are of interest for cellular processes, too, and can be regarded as components in interfaces for the information exchange between living nature and digital electronic systems. In this minireview, different types of chip reactors for biotechnological applications like nanotiterplates, chip thermocyclers and devices for segmented flow operations are discussed. Finally, an outlook is given on the application of chip reactor systems, which are promising tools for automated experiments with highly parallelized screening procedures, for artificial microcompartmentation, cell analogue systems, micro-ecological studies, investigations on modulated morphogenesis, and for a bioanalogue molecular nanotechnology.
This paper deals with the manufacturing state of the art of biochip, and introduces a new method--laser microtechnology, including its developing procedure, characteristics and function in biochip production.
Three protocols in this issue highlight applications of emulsification procedures, which deliver high-throughput potential to the molecular biology laboratory, without the need for automation. These procedures have already generated interesting results and spurred the development of exciting new technologies, while requiring only readily available laboratory equipment.
This work integrates rapid techniques for mutation detection by producing single-stranded DNA and (renatured) double-stranded DNA on-chip, labeling these with fluorescent DNA stains and then performing two complementary methods of mutation detection-single stranded conformation polymorphism (SSCP) analysis and heteroduplex analysis (HA). This involves the denaturation of double-stranded polymerase chain reaction (PCR) product into single-stranded DNA, the mutation analysis of the single-stranded DNA by SSCP and the rehybridized double-stranded DNA by HA. These steps were performed entirely on-chip within several minutes of operation. The combination of these two mutation detection methods on-chip provides a highly sensitive method of mutation detection for either genotyping or screening. Many mutation analysis methods rely upon fluorescently labeled samples from a PCR with fluorescently labeled primers. By labeling on-chip we not only attain improved signal strength, but the method is considerably more versatile. Although we used PCR products in this work, this method could be used to analyze DNA from any source. We believe that this combination of several procedures on a single chip represents a significant step in the development of higher levels of integration upon microfluidic devices.
Molecular diagnostics is being revolutionized by the development of highly advanced technologies for DNA and RNA testing. One of the most important challenges is the integration of microelectronics to microchip-based nucleic acid technologies. The specific characteristics of these microsystems make the miniaturization and automation of any step of a molecular diagnostic procedure possible. This review describes the application of microelectronics to all the processes involved in a genetic test, particularly to sample preparation, DNA amplification and sequence variation detection.
The current interest in micro-fabrication has extended to the clinical arena where there is a growing lobby for promoting these for point-of-care purposes. The advantages of such devices are their relative speed of analysis, lower reagent costs, and their application to clinical screening and diagnosis. Two chip-based capillary electrophoresis systems have been designed and their performance evaluated for rapidly measuring the concentrations of inflammatory neuropeptides in tissue fluids of patients with neuropeptide-associated muscle pain. Both chips were manufactured to fit a commercially available chip electrophoresis system. One chip was designed to perform electrokinetic flow immunoassays while the other utilized an immunoaffinity port, containing an array of immobilized antibodies, to capture the analytes of interest. Comparison of the results to commercially available high-sensitivity immunoassays demonstrated that both chip-based systems could provide a relatively fast, accurate procedure for studying inflammatory biomarkers in complex biological fluids. However, the immunoaffinity capture system proved the superior of the two chips. Using this system, twelve different inflammation-associated mediators could be determined in approximately 2 min as compared to 30 min when using the flow immunoassay chip. With the ever-expanding array of antibodies that are commercially available, this chip-based system can be applied to a wide variety of different analyses.
Detection of native amino acids was accomplished using a capillary electrophoresis (CE)-amperometric detection system, in which a single carbon fiber cylinder (CFC) working electrode instead of a carbon fiber disc (CFD) electrode was mounted in the end part of a poly(dimethylsiloxane) (PDMS)/glass hybrid microchannel. Similar to that using CFD working electrode, here, the electrochemical reduction reaction at the working electrode is also coupled from the separation high voltage system, the coupling degree is related to the in-channel length of the CFC. This property simplifies the fabrication procedure of the working electrode and also provides a convenient and sensitive means for the determination of non-electroactive ions by amperometry. The present detection mode is successfully used to electrochemically detect non-electroactive arginine (Arg), threonine (Thr), glutamic acid (Glu) and electroactive cysteine (Cys). Furthermore, by simply changing the detection potential, we can easily distinguish peak mobilities of electroactive amino acids from that of non-electroactive amino acids.
A microchip-based enzyme-linked immunosorbent assay (microELISA) system was developed and interferon-gamma was successfully determined. The system was composed of a microchip with a Y-shaped microchannel and a dam structure, polystyrene microbeads, and a thermal lens microscope (TLM). All reactions required for the immunoassay were done in the microchannel by successive introduction of a sample and regents. The enzyme reaction product, in a liquid phase, was detected downstream in the channel using the TLM as substrate solution was injected. The antigen-antibody reaction time was shortened by the microchip integration. The limit of the determination was improved by adopting the enzyme label. Moreover, detection procedures were greatly simplified and required time for the detection was significantly cut. The system has good potential to be developed as a small and automated high throughput analyzer.
A thin chip polymer-based microsprayer has been coupled to a hybrid quadrupole time-of-flight mass spectrometer (QTOF MS) and introduced in carbohydrate research. The feasibility of the approach is demonstrated for mapping, sequencing and structural elucidation of glycoconjugates originating from human body fluids and tissues such as a glycopeptide mixture from normal human urine and an isolated and purified GT1 ganglioside fraction from normal adult human brain. The optimization procedure required by each glycoconjugate category is described and the advantages of the system in terms of flexibility and adaptability to QTOF MS, stability of the ESI MS signal, carbohydrate ionization and sequencing, sensitivity, speed of analysis and sample consumption are discussed.
Design and synthesis of a new heterobifunctional reagent, N-(iodoacetyl)-N'-(anthraquinon-2-oyl)-ethylenediamine (IAED), have been described for the preparation of oligonucleotide-based biochips. The performance of the featured reagent is probed by the immobilization of thiolated and thiophosphorylated oligonucleotides on modified glass microslides via two routes (routes A and B). The immobilization procedure was accelerated by performing a chemical reaction between thiolated oligomers and the iodoacetyl moiety of the reagent under microwaves (MW), where it is completed in just 10 min. The quality of the constructed oligonucleotide microarrays was tested by performing a hybridization assay with a complementary target and subsequently used for the detection of base mismatches. The immobilized probes were found to be thermally stable.
DNA microarrays have become a powerful tool for expression profiling and other genomics applications. A critical factor for their sensitivity is the interfacial coating between the chip substrate and the bound DNA. Such a coating has to embrace the divergent requirements of tightly binding the capture probe DNA during the spotting process and of minimizing the nonspecific binding of target DNA during the hybridization assay. To fulfill these conditions, most coatings require a passivation step. Here we demonstrate how the chain density of a graft copolymer with a polycationic backbone, poly(l-lysine)-graft-poly(ethylene glycol), can be tuned such that the binding capacity during capture probe deposition is maximized while the nonspecific binding during hybridization assays is kept to a minimum, thus alleviating the requirement for a separate passivation procedure. Evidence for the superior performance of such coatings in terms of signal-to-noise ratio and spot quality is presented using an evanescent field-based fluorescent sensing technique (the ZeptoREADER). The surface architecture is further characterized using optical waveguide lightmode spectroscopy and time-of-flight secondary ion mass spectrometry. Finally, in a model assay, we demonstrate that expression changes can be detected from 1 microg of total mRNA sample material with a limit of detectable differential expression of +/-1.5.
The design and optimization of light-based analytical devices often require optical characterization of materials involved in their construction. With the aim of benefiting lab-on-a-chip applications, a transmission spectrometric method for determining refractive indices, n, of transparent solids is presented here. Angular dependence of the reflection coefficient between material-air interfaces constitutes the basis of the procedure. Firstly, the method is studied via simulation, using a theoretical algorithm that describes the light propagation through the sample slide, to assess the potentially attainable accuracy. Simulations also serve to specify the angles at which measurements should be taken. Secondly, a visible light source and an optical fiber spectrometer are used to perform measurements on three commonly used materials in optical lab-on-a-chip devices. A nonlinear regression subroutine fits experimental data to the proposed theoretical model and is used to obtain n. Because the attainable precision using this method of refractive index determination is dictated by the uncertainty in the transmission measurements, the precision (with 95% confidence) for mechanically rigid samples, namely glass and poly(methyl methacrylate) (PMMA), is higher than those estimated for the elastomer sample (in-house-molded poly(dimethylsiloxane) (PDMS)). At wavelengths with the highest signal-to-noise ratio for the spectrometer setup, the estimated refractive indices were 1.43+/-0.05 (580 nm) for PDMS, 1.54+/-0.02 (546 nm) for glass, and 1.485+/-0.005 (656 nm) for PMMA. Accurate refractive index estimations with an average precision equal to 0.01 refractive index units (RIU) were obtained for PMMA and glass samples, and an average precision of 0.09 RIU for the PDMS molded slide between 550 and 750 nm was obtained.
We examined the feasibility of using a two-color time-resolved detection scheme with microdevices for DNA sequencing applications. A home-built dual-color optical-fiber-based time-resolved near-infrared (IR) fluorescence microscope successfully coupled lifetime discrimination with color discrimination, increasing fluorescence multiplexing capabilities. The instrument was constructed by using two pulsed-diode lasers (680/780-nm excitation) and two avalanche photodiodes as the basic building blocks. The data were processed using electronics configured in a time-correlated single-photon counting format. The use of near-IR fluorescence detection greatly simplified the hardware and allowed low detection limits (< 0.1nM). We examined the separation of a single-base tract on a microchip and compared the performance with that of conventional capillary gel electrophoresis. The microchip was fabricated in glass and contained an effective separation length of 7.0 cm. It was found that, without incorporating a solid-phase reversible immobilization cleanup procedure, the calculated lifetime of the dye label on the microchip was longer and the standard deviation was larger than those of the same sample analyzed using capillary electrophoresis. Using cleanup steps, the accuracy and precision of the measurements improved. Lifetimes of four near-IR dyes (AlexaFluor680, IRD700, IRD800, and IRD40) used in this study were determined to be 986 ps (RSD=2.1%), 1551 ps (RSD=1.8%), 520 ps (RSD=3.3%), and 788 ps (RSD=4.9%), respectively, in a microchannel filled with poly(dimethylacrylamide) (POP-6) gel. The lifetimes calculated using maximum likelihood estimators provided favorable precision on the microchip, where small numbers of photocounts were collected. An M13mp18 template was sequenced on the microchip using a two-color two-lifetime format with POP-6 as the sieving polymer. Read lengths of 294 bp with calling accuracies of 90.8 and 83.7% were achieved in each color channel. The relatively low calling accuracy and the short read length resulted primarily from the short separation channel, which yielded low electrophoretic resolution.
A novel DNA solid-phase extraction protocol based on the pH-dependent charge of chitosan was developed specifically for low-volume DNA extraction on microchips. The method uses chitosan-coated beads to extract DNA at pH 5 and release it from the chitosan at pH 9. DNA extraction efficiency as high as 92% could be attained, even from complex samples such as human blood containing significant amounts of protein. Using this method, PCR inhibitors that are typically used in DNA extraction procedures (e.g., chaotropic salts, 2-propanol) can be avoided, making the method more conducive to downstream sample processing using PCR. A high-density multichannel microchip device was then fabricated and the microchannels coated with chitosan for DNA extraction in an open channel configuration without the need for an additional stationary phase. This design provided a relatively high surface area-to-volume ratio for extraction, while retaining the low flow resistance commensurate with open channels. With a flow rate of approximately 1 microL/min during the extraction, the total extraction time was less than 10 min, with most of the DNA recovered in the first 2 microL of elution buffer. Using the microchip device, extraction efficiencies for lambda-phage DNA and human genomic DNA were as high as 67 and 63%, respectively. Human genomic DNA from whole blood samples could be extracted in 10 min with an extraction efficiency of 75 +/- 4% (n = 3), and the purified DNA was suitable for PCR amplification of a fragment of the gelsolin gene. The combination of an entirely aqueous DNA extraction method with a high-density, low-flow resistance microchannel pattern sets the stage for future integration into microfluidic genomic analysis devices.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.