Frequency relationships for ultrasonic activation of free microbubbles, encapsulated microbubbles, and gas-filled micropores.

The ultrasonic activation of free microbubbles, encapsulated microbubbles, and gas-filled micropores was explored using available linear theory. Encapsulated microbubbles, used in contrast agents for diagnostic ultrasound, have relatively high resonance frequencies and damping. At 2 MHz the resonance radii are 1.75 microns for free microbubbles, 4.0 microns for encapsulated microbubbles, and 1.84 microns for gas-filled micropores. Higher-pressure amplitudes are needed to elicit equivalent subharmonic, fundamental, or second-harmonic responses from the encapsulated microbubbles, and this behavior increases for higher frequencies. If an encapsulated microbubble becomes destabilized during exposure,the resulting liberated microbubble would be about twice the linear resonance size, which would be likely to produce subharmonic signals. Scattered signals used for medical imaging purposes may be indicative of bioeffects potential: The second harmonic signal is proportional to local shear stress for a microbubble on a boundary, and a strong subharmonic signal may imply destabilization and nucleation of free-microbubble cavitation activity. The potential for bioeffects from contrast agent gas bodies decreases rapidly with increasing frequency. This information should be valuable for understanding of the etiology of bioeffects related to contrast agents and for developing exposure indices and risk management strategies for their use in diagnostic ultrasound.

Air↗

Avoiding microbubbles formation during radiofrequency left atrial ablation versus continuous microbubbles formation and standard radiofrequency ablation protocols: comparison of energy profiles and chronic lesion characteristics.

BACKGROUND: Radiofrequency (RF) energy parameters and chronic lesion characteristics associated with the microbubbles formation have not been yet fully elucidated. OBJECTIVES: The objective of this study was to compare the energy profiles and chronic lesion characteristics associated with RF ablation of the pulmonary vein antrum using three different ablation protocols: (1) avoiding microbubbles; (2) continuous microbubble formation; (3) temperature-guided ablation. METHODS: A 4-mm tip ablation catheter was used for creating RF ablation lesions in 15 adult mongrel dogs. All ablation lesions were created at the posterior aspect of the PV antrum in each animal. Avoiding microbubbles (group 1, n = 5 dogs, 23 lesions), continuous microbubble formation (group 2, n = 5 dogs, 22 lesions), and temperature-guided (group 3, n = 5 dogs, 19 lesions, target temperature 60 degrees C/power limit 50 W) ablation lesions were analyzed. RESULTS: Group 1 showed significantly lower power (19 +/- 8.6 W), lower temperature (50 +/- 4.8 degrees C), higher efficiency-of-heating index (2.9 +/- 0.8 degrees C/W), and lower impedance (109 +/- 24.4 Omega) than groups 2 (38 +/- 8.4 W; 63 +/- 10 degrees C; 1.8 +/- 0.8 degrees C/W; 148 +/- 34.4 Omega) and 3 (44 +/- 12 W; 57 +/- 2.4 degrees C; 1.4 +/- 0.5 degrees C/W; 139 +/- 23.1 Omega) (P < 0.001 vs groups 2 and 3). During ablation, no significant events were detected in group 1, but 11 cases of audible pop, 11 cases of catheter tip charring, and 1 case of fatal myocardial perforation were observed in groups 2 and 3. Transmural lesions were more frequently created in group 1. CONCLUSION: RF energy delivery applying "avoiding microbubbles" protocol seems to be associated with higher degree of safety and efficacy when compared to temperature-guided and continuous microbubble-formation ablation protocols.

Animals↗

Ethanol resistive microbubble test: a modification of the stable microbubble test used to predict respiratory distress syndrome.

The stable microbubble (SM) test on gastric aspirate obtained at birth proved useful in identifying infants who would develop respiratory distress syndrome (RDS). This test involves only the count of stable microbubbles of < or = 15 microns in diameter. Larger bubbles (> 15 microns in diameter) are not necessary for the test and may interfere with stable microbubble counting. The aims of the present study were to determine: (i) if larger bubbles could be selectively removed by adding ethanol, a potent bubble breaker; and (ii) if the predictive value of this modified test, the ethanol resistive microbubble (ERM) test, on the development of RDS was similar to that of the SM test. Varying amounts of different concentrations of ethanol-water solutions were added to the top of the bubble crop generated by the SM test procedure, and the mean counts of stable microbubbles and larger bubbles in five regions were calculated. A volume of 10 microL of 47.5% ethanol was effective in defoaming larger bubbles generated by the SM test procedure without altering the stable microbubble counts. When concurrently performed on 43 samples of gastric aspirate obtained at birth from infants of less than 35 weeks gestation, the RDS predictive value of the ERM test was similar to that of the SM test. It was concluded that the ERM test may serve as an alternative to the SM test.

Amniotic Fluid↗

Gene transfer with microbubble ultrasound and plasmid DNA into skeletal muscle of mice: comparison between commercially available microbubble contrast agents.

PURPOSE: To compare three commercial microbubble contrast agents (Optison, SonoVue, and Levovist) for their effect on gene delivery in skeletal muscle in conjunction with the use of therapeutic ultrasound. MATERIALS AND METHODS: The study was approved by the Animal Care and Use Committee. Plasmid DNA (10 microg) encoding green fluorescent protein (GFP) was mixed with microbubbles (or saline control) and injected into the tibialis anterior muscle of mice with and without adjunct ultrasound (1 MHz, 2 W/cm2, 30 seconds, 20% duty cycle). The efficiencies of GFP transgene expression were determined with four experimental conditions: (a) plasmid and saline as control (six mice), (b) plasmid and Optison (six mice), (c) plasmid and SonoVue (four mice), and (d) plasmid and Levovist (air based, four mice). The right legs were exposed to ultrasound, while the left legs were unexposed. Transfection efficiency was assessed by counting the number of GFP-positive fibers. Tissue damage was assessed by measuring the maximal-damage area on serial sections. RESULTS: When ultrasound was applied, both SonoVue and Optison significantly improved (P < .05) gene transfection efficiency. Optison was also effective (P < .05) even when no ultrasound was applied, which is consistent with previous studies. Levovist without ultrasound decreased the level of transfection (P < .05), with increased tissue damage. CONCLUSION: Both non-air-based agents show promise in gene delivery in skeletal muscle with undetectable tissue damage. Enhanced gene transfer with additional ultrasound was achieved only with SonoVue.

Albumins↗

Effect of blood and microbubble oxygen and nitrogen content on perfluorocarbon-filled dextrose albumin microbubble size and efficacy: in vitro and in vivo studies.

We hypothesized, on the basis of in vitro observations, that a higher oxygen partial pressure within perfluorocarbon-containing microbubbles (PCMB) would enhance inward nitrogen diffusion after venous injection, leading to improved myocardial contrast. The in vitro studies measured PCMB size and concentration after injection into arterial blood that was obtained during inhalation of either room air or 100% oxygen. We then compared the myocardial contrast produced from PCMB sonicated in the presence of either a nitrogen-free environment (100% oxygen) or room air in three closed chest dogs. PCMB exposed to oxygenated blood in vitro were significantly smaller after insonation than PCMB exposed to arterial blood obtained during room air inhalation, confirming the important role of dissolved nitrogen in stabilizing PCMB size. In vivo studies demonstrated that intravenous PCMB sonicated with 100% oxygen produced significantly greater anterior and posterior myocardial contrast than PCMB sonicated in the presence of room air.

Animals↗

Detection of retained microbubbles in carotid arteries with real-time low mechanical index imaging in the setting of endothelial dysfunction.

OBJECTIVES: We sought to determine if intravenously injected microbubbles would be retained by the carotid arteries (CAs) in the setting of endothelial dysfunction (ED) using a linear transducer equipped with a low mechanical index pulse sequence scheme (PSS). BACKGROUND: Microbubbles normally pass freely through large and small vessels but are retained in regions with ED. New high-frequency low mechanical index PSS can potentially be utilized to image these retained microbubbles. METHODS: Intravenous albumin- and lipid-encapsulated microbubbles were administered in seven pigs while imaging the CAs before and after a 20% intralipid infusion to induce hypertriglyceridemia. The degree of microbubble retention was quantified by measuring endothelial acoustic intensity (AI) after clearance of free-flowing microbubbles. Microbubble adherence was also evaluated after selective balloon injury of the CAs. The CA diameter responses to acetylcholine were quantified. RESULTS: After induction of hypertriglyceridemia, adherence of albumin-encapsulated microbubbles was visually evident in all CAs, and endothelial AI increased significantly (p < 0.001 compared with baseline). The CA responses to acetylcholine went from vasodilation at baseline to vasoconstriction during hypertriglyceridemia. Endothelial AI also increased in the balloon-stretched vessels (p < 0.01 compared with uninjured vessels) after albumin-encapsulated microbubble injection, with a ring of microbubbles selectively adhering to the injured segment. This retention was not observed with lipid-encapsulated microbubbles. Scanning electron microscopy confirmed that albumin-coated microbubbles adhered to endothelial cells. CONCLUSIONS: Retention of intravenously injected albumin microbubbles occurs in the setting of both global and regional ED in large vessels and can be noninvasively imaged with high-frequency low mechanical index PSS.

Acoustics↗

[Synthesis of new gene-loaded microbubbles serve as gene delivery vehicle applied in reporter gene transfer into cardiac myocytes].

To improve the stability and gene-carried capability of gene-attached microbubbles, the method for manufacture of albumin microbubbles was modified and new gene-loaded microbubbles were synthesized by incorporated gene-PEI complex into the shell of microbubbles. Agarose gel electrophoresis and bacteria transformation showed that PEI had the ability to provide the protection of plasmid DNA from ultrasonic degradation. The new gene-loaded microbubbles exhibited excellent acoustical and hemorheological properties. Moreover, they could carry more plasmid DNA than gene-attached microbubbles. beta-galactosidase plasmid transfection into cardiac myocytes was performed by using ultrasound targeted destruction of new gene-loaded microbubbles or gene-attached microbubbles. Gene expression in cardiac myocytes was detected by beta-galactosidase in situ staining and quantitive assay. It was shown that beta-galactosidase activity in cardiac myocytes was enhanced 107-fold by ultrasonic destruction of gene-loaded microbubbles compared with naked plasmid transfection and new gene-loaded microbubbles resulted in 6.85-fold increase in beta-galactosidase activity compared with optimal transfection mediated by gene-attached microbubbles. These results suggested that ultrasonic destruction of the gene-loaded microbubbles can enhance the cardiac myocytes exogenous gene transfer efficiency significantly and new gene-loaded microbubbles is an efficient and safe gene delivery vehicle.

Animals↗

Fundamental studies on contrast images from different-sized microbubbles: analytical and experimental studies.

Microbubbles are very useful as ultrasound (US) contrast agents because of their excellent scattering properties. Because microbubbles of different sizes can be used for this purpose, the contrast images produced by different-sized microbubbles are studied in this paper. The contrast images from microbubbles of average sizes 35.5 microm and 2.1 microm were investigated experimentally. Although a low concentration of microbubbles produces contrast-enhanced images without artefacts, an excess of microbubbles results in distorted images. From experimental observation, the distortion of an image caused by microbubbles of average size 35.5 microm was mainly due to multiple scattering, and that by 2.1-microm microbubbles was due to the acoustic shadowing effect. With the use of the tissue-mimicking phantoms of known acoustical properties, the brightness of the contrast images from the microbubble suspension was calculated. The calculated and experimental results of the contrast images produced from microbubbles of average size 35.5 microm were closer to each other when there was no image distortion. When image distortion caused by multiple-scattering occurred, the experimental pixel brightness was higher. For smaller microbubbles of average size 2.1 microm, calculated results of free microbubbles showed a weaker contrast effect than the experimental results. By taking the effect of the coatings of microbubbles into consideration, the calculated brightness of contrast images became much closer to the experimental one.

Artifacts↗

Interactions between microbubbles and ultrasound: in vitro and in vivo observations.

OBJECTIVES: We attempted to examine the interactions between ultrasound and microbubbles. BACKGROUND: The interactions between microbubbles and ultrasound are poorly understood. We hypothesized that 1) ultrasound destroys microbubbles, and 2) this destruction can be minimized by limiting the exposure of microbubbles to ultrasound. METHODS: We performed in vitro and in vivo experiments in which microbubbles were insonated at different frequencies, transmission powers and pulsing intervals. Video intensity decay was measured in vitro and confirmed by measurements of microbubble size and concentrations. Peak video intensity and mean microbubble myocardial transit rates were measured in vivo. RESULTS: Imaging at lower frequencies and higher transmission powers resulted in more rapid video intensity decay (p = 0.01), and decreasing exposure of microbubbles to ultrasound minimized their destruction in vitro. Although these effects were also noted in vivo with venous injections of microbubbles, they were not seen with aortic root or direct coronary artery injections. CONCLUSIONS: Ultrasound results in microbubble destruction that is more evident at lower frequencies and higher acoustic powers. Reducing the exposure of microbubbles to ultrasound minimizes their destruction. This effect is most marked in vivo with venous rather than aortic or direct coronary injections of microbubbles. These findings could lead to effective strategies for myocardial perfusion imaging with venous injections of microbubbles.

Albumins↗

Noninvasive imaging of inflammation by ultrasound detection of phagocytosed microbubbles.

BACKGROUND: We have previously shown that microbubbles adhere to leukocytes in regions of inflammation. We hypothesized that these microbubbles are phagocytosed by neutrophils and monocytes and remain acoustically active, permitting their detection in inflamed tissue. METHODS AND RESULTS: In vitro studies were performed in which activated leukocytes were incubated with albumin or lipid microbubbles and observed under microscopy. Microbubbles attached to the surface of activated neutrophils and monocytes, were phagocytosed, and remained intact for up to 30 minutes. The rate of destruction of the phagocytosed microbubbles on exposure to ultrasound was less (P</=0.05) than that of free microbubbles at all acoustic pressures applied. Intravital microscopy and simultaneous ultrasound imaging of the cremaster muscle was performed in 6 mice to determine whether phagocytosed microbubbles could be detected in vivo. Fifteen minutes after intravenous injection of fluorescein-labeled microbubbles, when the blood-pool concentration was negligible, the number of phagocytosed/attached microbubbles within venules was 7-fold greater in tumor necrosis factor-alpha (TNF-alpha)-treated animals than in control animals (P<0.01). This increase in retained microbubbles resulted in a 5- to 6-fold-greater (P<0.01) degree of ultrasound contrast enhancement than in controls. CONCLUSIONS: After attaching to activated neutrophils and monocytes, microbubbles are phagocytosed intact. Despite viscoelastic damping, phagocytosed microbubbles remain responsive to ultrasound and can be detected by ultrasound in vivo after clearance of freely circulating microbubbles from the blood pool. Thus, contrast ultrasound has potential for imaging sites of inflammation.

Animals↗

The role of complement in the adherence of microbubbles to dysfunctional arterial endothelium and atherosclerotic plaque.

OBJECTIVE: To determine whether serum complement C3 mediates adherence of albumin-encapsulated microbubbles to vascular endothelium in the development of atherosclerotic plaques. METHODS: Adherence of microbubbles to aortic endothelium was examined with scanning electron microscopy following intravenous injection of 20% intralipid in wild-type mice, genetic complement-deficient mice (C3-/-), and in pharmacologic C3-depleted wild-type mice. In a second experimental model, atherosclerostic plaque was induced in apolipoprotein E-deficient mice (apoE-/-), and adherence of microbubbles to atherosclerotic plaques was evaluated using fluorescent microscopy of fluorescein isothiocynate-conjugated microbubbles. Finally, imaging of aortas was performed in eight rats (four JCR:LA-cp atherosclerosis-prone rats on high cholesterol diets; four controls) following intravenous albumin microbubble injections (PESDA) to determine whether microbubble adherence to the endothelium could be detected with low mechanical index pulse sequence schemes. RESULTS: Scanning electron microscopy confirmed the adherence of microbubbles to the endothelial cells of the aorta in wild-type mice following induction of hypertriglyceridemia but not in C3-depleted mice. Microbubble adherence to the endothelial surface of atherosclerotic plaque was confirmed in all apoE-/- mice (median 172 microbubbles/field; compared to a median of 3 microbubbles/field in cobra venom factor-treated apoE-/- mice; p < 0.001). Low mechanical index ultrasound imaging detected microbubble adherence in all JCR atherosclerosis prone rats even in the absence of vasomotor or phenotypical evidence of endothelial dysfunction. The numbers of adherent microbubbles correlated with serum triglyceride levels, and were seen in conjunction with increased endothelial nitric oxide synthase activity. CONCLUSIONS: Complement C3 binds to albumin-encapsulated microbubbles and mediates microbubble adherence to vascular endothelium both early and late in the atherosclerotic process.

Albumins↗

Deformable gas-filled microbubbles targeted to P-selectin.

Ultrasound contrast microbubbles have been successfully targeted to a number of intravascular disease markers. We hypothesized that targeted delivery could be improved further, by making the microbubbles deformable, leading to increased microbubble-endothelium adhesion contact area and stabilized adhesion. Activated leukocytes utilize such strategy; they deform after binding to inflamed endothelium in the vasculature. Lipid-shell microbubbles were targeted to the endothelial inflammatory protein P-selectin with a monoclonal anti-P-selectin antibody attached to the microbubble shell. Deformable microbubbles were created by controlled pressurization with partial gas loss, which generated an average excess shell surface area of approximately 30% and the formation of outward-projected wrinkles and folds. Targeted microbubble adhesion and deformability were assessed in the parallel plate flow chamber under shear flow. Sustained adhesion of deformable microbubbles at wall shear stresses between 0.4 and 1.35 dyn/cm(2) was consistently better than adhesion of wrinkle-free microbubbles. Over this shear range, targeted wrinkled microbubbles were deformed by shear flow, unlike wrinkle-free microbubbles. In a murine cremaster inflammation model, a significant improvement of deformable microbubble targeting was observed by intravital microscopy. Overall, the mechanical aspects of adhesion, such as particle shape, deformability and surface microstructure, are important in engineering efficient site-targeted particle-based agents for medical imaging and therapy.

Animals↗

Influence of microbubble surface charge on capillary transit and myocardial contrast enhancement.

OBJECTIVE: The goal of the study was to determine whether microbubble charge influences the microvascular retention of microbubble contrast agents. BACKGROUND: Interactions between serum proteins and lipid membranes are greater with anionic compared with neutral membranes. These interactions may influence the microvascular behavior of anionic lipid microbubbles. METHODS: Intravital microscopy of the cremaster muscle was performed in six wild-type mice and three C3-deficient mice during intravenous injection of lipid-shelled microbubbles with either a neutral or a negative charge. Both agents were prepared with and without a protective surface layer of polyethyleneglycol (PEG). Complement attachment to microbubbles was assessed by flow cytometry with flourescein isothiocyanate-conjugated anti-C3b monoclonal antibody. Myocardial contrast echocardiography was performed in six dogs to assess pulmonary and myocardial retention of microbubbles. RESULTS: Size-independent capillary retention of microbubbles, occurring for a few seconds to >10 min, was frequently observed with anionic, but rarely with neutral, microbubbles (4.3 +/- 0.3 vs. 0.4 +/- 0.1 mm(-3), p < 0.01). Anionic microbubble retention was reduced by 70% by surface PEG and was also markedly reduced in C3-deficient mice (1.4 +/- 0.1 mm(-3), p < 0.05 vs. wild-type). Flow cytometry demonstrated complement attachment to only anionic microbubbles. Contrast echocardiography indicated both pulmonary and myocardial retention of only anionic microbubbles, the latter evidenced by persistent opacification >10 min after bolus intravenous injection. CONCLUSIONS: Lipid microbubbles with a net negative charge can be retained within capillaries via complement-mediated attachment to endothelium. This property may be useful for the development of ultrasound contrast agents that can be imaged late after venous injection.

Animals↗

Smaller intravenous perfluorocarbon-containing microbubbles produce greater myocardial contrast with intermittent harmonic imaging and better delineation of risk area during acute myocardial ischemia.

The purpose of this article was to determine whether applying negative or positive pressure to perfluorocarbon-containing microbubbles before intravenous injection would improve the myocardial contrast when using newer imaging techniques such as harmonic and intermittent imaging. Perfluorocarbon-containing microbubbles were exposed to sustained negative or positive pressure before intravenous injection in 10 dogs. Microbubble size distribution and concentration were measured after each exposure. Peak myocardial videointensity with intermittent harmonic imaging with each sample was compared. Microbubbles exposed to -200 mm Hg pressure before intravenous injection produced both the highest concentration of microbubbles and greater numbers of microbubbles less than 4 microns. Peak myocardial videointensity did not correlate with microbubble concentration or size but did correlate with the absolute number of microbubbles < 4 microns (mean r value 0.76, range 0.61 to 0.90). Risk area was best visualized with perfluorocarbon-containing microbubble samples containing the smallest microbubbles. We conclude that the myocardial contrast observed with perfluorocarbon-containing microbubbles can be enhanced by applying negative pressure before injection. The mechanism for this improved contrast appears to be related to creation of smaller microbubbles.

Animals↗

Acoustic properties of NC100100 and their relation with the microbubble size distribution.

RATIONALE AND OBJECTIVES: NC100100 is a contrast agent for medical imaging with ultrasonography consisting of stabilized gas microbubbles in an aqueous suspension. The objective of this article is to explore the acoustic properties of NC100100 and their relation with the microbubble size distribution. The results are used to motivate the choice of a suitable assay/dosage parameter for precise control of product efficacy. METHODS: The concentration and size distribution of microbubbles in > 50 preparations of NC100100 were determined by Coulter counting, and the acoustic attenuation and backscatter efficacy were determined for all samples. The in vivo efficacy of the product was investigated by harmonic imaging of the heart in a dog model. RESULTS: The results demonstrated that the attenuation and backscatter efficacy per microbubble volume vary strongly with size, showing distinct maxima with respect to microbubble diameter. Sizes for optimal attenuation per volume ranged from 2.6 to 5.8 microns, depending on ultrasound frequency. The contribution of the smaller end tail of the microbubble distribution was shown to be negligible. From the observed size dependency for the acoustic properties, the volume concentration of microbubbles was chosen as the assay/dosage parameter for NC100100. The accuracy of this parameter as a descriptor of product efficacy was demonstrated by precise, linear relations between volume, concentration, and attenuation/backscatter. In comparison, the correlation between the microbubble number and acoustic properties was not significant. Results from the in vivo study showed a precise, linear relation between injected microbubble volume and the observed in vivo efficacy. CONCLUSIONS: The acoustic properties of NC100100 are dependent on microbubble size. The observed batch-to-batch variance in the acoustic properties of the product may be fully explained by variation in concentration and size. Microbubble volume is a more precise predictor of in vitro/in vivo efficacy than microbubble number and consequently was chosen as the assay/dosage parameter for NC100100.

Acoustics↗

Microbubble persistence in the microcirculation during ischemia/reperfusion and inflammation is caused by integrin- and complement-mediated adherence to activated leukocytes.

BACKGROUND: Albumin microbubbles that are used for contrast echocardiography persist within the myocardial microcirculation after ischemia/reperfusion (I-R). The mechanism responsible for this phenomenon is unknown. METHODS AND RESULTS: Intravital microscopy of the microcirculation of exteriorized cremaster muscle was performed in 12 wild-type mice during intravenous injections of fluorescein-labeled microbubbles composed of albumin, anionic lipids, or cationic lipids. Injections were performed at baseline and after 30 to 90 minutes of I-R in 8 mice and 2 hours after intrascrotal tumor necrosis factor-alpha (TNF-alpha) in 4 mice. Microbubble adherence at baseline was uncommon (<2/50 high-power fields). After I-R, adherence increased (P<0.05) to 9+/-5 and 5+/-4 per 50 high-power fields for albumin and anionic lipid microbubbles, respectively, due to their attachment to leukocytes adherent to the venular endothelium. TNF-alpha produced even greater microbubble binding, regardless of the microbubble shell composition. The degree of microbubble attachment correlated (r=0.84 to 0.91) with the number of adhered leukocytes. Flow cytometry revealed that microbubbles preferentially attached to activated leukocytes. Albumin microbubble attachment was inhibited by blocking the leukocyte beta(2)-integrin Mac-1, whereas lipid microbubble binding was inhibited when incubations were performed in complement-depleted or heat-inactivated serum rather than control serum. CONCLUSIONS: Microvascular attachment of albumin and lipid microbubbles in the setting of I-R and TNF-alpha-induced inflammation is due to their beta(2)-integrin- and complement-mediated binding to activated leukocytes adherent to the venular wall. Thus, microbubble persistence on contrast ultrasonography may be useful for the detection and monitoring of leukocyte adhesion in inflammatory diseases.

Albumins↗

Prevalence of microbubbles associated with mechanical prosthetic cardiac valves: a prospective transesophageal echocardiography study.

BACKGROUND AND AIM OF THE STUDY: The study aim was to identify the prevalence of microbubbles in different types of mechanical cardiac valve and, if feasible, to associate microbubbles with various clinical conditions, including thrombotic occlusion of the valves. METHODS: A total of 153 mechanical prosthetic valves were studied (58 aortic, 95 mitral) in 140 patients, prospectively. All valves were functioning normally. In addition, eight mitral prosthetic valves were selected without microbubbles and with an obstructive valvular thrombosis that had undergone successful thrombolysis (group 1); a further eight patients with unsuccessful thrombolysis (group 2) were studied by transesophageal echocardiography before and after thrombolytic therapy. RESULTS: Microbubbles were detected in 75% (114/153) of prosthetic valves, 99% (88/89) of bileaflet valves, and 45% (29/64) of monoleaflet valves (p < 0.0001). Only 14% (4/28) of Sorin monoleaflet valves were associated with microbubbles, which is distinctively less than other valves (p < 0.001 for each); 71% and 77% of aortic and mitral prosthetic valves, respectively, were associated with microbubbles (p = NS). Prosthetic valves with an obstructive thrombosis and no microbubbles in group 1 showed new appearance of microbubbles in 88% (7/8) of cases after successful thrombolysis. Absence of microbubbles in group 2 persisted in all eight patients at the second examination. CONCLUSIONS: Microbubbles were detected in a greater proportion of patients than reported previously and were found to be associated more with bileaflet prosthetic heart valves than with monoleaflet valves. Sorin monoleaflet valves were associated with microbubbles dramatically less than all other valves. The new appearance of microbubbles after thrombolytic therapy of mechanical prosthetic heart valves with an obstructive thrombosis may indicate successful thrombolysis.

Adult↗