Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Limit of Detection”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

K-ras gene mutations in the diagnosis of fine-needle aspirates of pancreatic masses: prospective study using two techniques with different detection limits.

Detection of K-ras mutations may be useful in the evaluation of pancreatic cancer. The aim of this study was to assess, in a prospective design, the diagnostic utility of K-ras mutation analysis in 62 consecutive fine-needle aspirates of pancreatic masses, using two PCR-based techniques-standard and enriched-with detection limits of a mutant allele in the presence of 10(2) or 10(3) wild-type alleles, respectively. Cytology alone offered a diagnostic sensitivity of 75%. The enriched higher sensitivity detection technique, in combination with cytology, offered a diagnostic sensitivity of 91% without false positives. The molecular analysis would have contributed to diagnosis in an additional 14 cases of pancreatic cancer. The standard technique contributed to diagnosis in an additional 9 cases. These results strongly support the use of the enriched method of detecting K-ras mutations as a complement to cytology in the evaluation of pancreatic masses.

Aged↗

Improving the detection limit of anion-selective electrodes: an iodide-selective membrane with a nanomolar detection limit.

The lower detection limit and the selectivity behavior of anion-selective electrodes (ISEs) are improved by using optimized inner solutions and membrane compositions. With a membrane based on the recently described ionophore [9]mercuracarborand-3, a detection limit of 2 x 10(-9) M has been achieved for iodide. Nevertheless, the improvements are less pronounced than in the case of cation ISEs. This is mainly due to the fact that so far no anion ISE is known with the extremely high selectivities of cation ISEs. If the membrane does not contain an ionophore, leaching of the ion exchanger from the membrane into the sample is also a relevant limiting factor except for ion exchangers of very high lipophilicity.

Anions↗

High-density fiber-optic genosensor microsphere array capable of zeptomole detection limits.

The detection limit of a fiber-optic microsensor array was investigated for simultaneous detection of multiple DNA sequences. A random array composed of oligonucleotide-functionalized 3.1-microm-diameter microspheres on the distal face of a 500-microm etched imaging fiber was monitored for binding to fluorescently labeled complementary DNA sequences. Inherent sensor redundancy in the microarray allows the use of multiple microspheres to increase the signal-to-noise ratio, further enhancing the detection capabilities. Specific hybridization was observed for each of three sequences in an array yielding a detection limit of 10(-21) mol (approximately 600 DNA molecules).

Animals↗

Imputation of data values that are less than a detection limit.

Results of the analyses of occupational and environmental samples are frequently reported as "less than a specified value," a practice followed by many analytical laboratories. A left-censored distribution occurs when analytical laboratories do not report results that fall below their limits of detection or quantification. Approximately 37% of the household interior dust lead loadings collected in a large-scale, multisite, longitudinal study of lead-based paint hazard controls were reported to be below the "method detection limit." These unreported values are unusable in any statistical analysis of the data and must be replaced by a valid dust lead loading estimate, a process called data imputation. This investigation tested how well data imputed using a newly formulated procedure for estimating the data below the method detection limit were correlated with dust lead loadings reported by the participating laboratories after special request. These results were also compared with those obtained by imputing the minimum detectable level by the square root of 2. Imputation of the low lead loadings was accomplished by substituting the value associated with the median percentile below each laboratory's method detection limit. A correlation of r = 0.50 was calculated between the predicted and reported dust lead loadings, with only slight bias (2.9%) in the predicted values. An alternative imputation procedure that used the predicted value from structural equation models fit to the noncensored dust lead loadings performed about as well, although the predictions had to be "centered" to correspond to the censored data. An estimator that combined both of these imputation procedures only slightly improved the correlation between the predicted and laboratory values (r = 0.51). These results support the use of the new procedure rather than the commonly used imputed values of the method detection limit divided by 2 or by the square root of 2. Imputing values based on either of these common approaches may result in much more biased predictions for the censored data; in the case of these data, the dust lead loadings were overestimated by 348%. The results also suggest that analytical laboratories should provide a numerical result for all analyzed samples, with a "flag" of those values below their detection limit, since these results may be more accurate than any imputed value, particularly those provided by the commonly used method of dividing the minimum detection limit by the square root of 2.

Air Pollutants↗

An evaluation of the detection limits possible for competitive capillary electrophoretic immunoassays.

Using a high-affinity antibody for estradiol, thermodynamic and experimental limitations on detection limits for competitive capillary electrophoretic immunoassays were examined. Theoretical modeling of the dose-response curves for such assays allowed for optimization of experimental conditions. Through the examination of experimental and theoretical results generalizations could be made as to the ability of capillary electrophoretic immunoassays to achieve low detection limits. An experimental detection limit of 310 pM, corresponding to 2100 molecules, was achieved. A minimum theoretical detection limit for the antibody of interest was approximated to be 125-525 pM depending on the standard deviation. An overview of the optimization process is given as well as commentary on theoretical predictions.

Antibodies↗

Absolute and/or relative detection limits in laser-based analysis: the end justifies the means.

The absolute limit of detection usually expresses the minimum amount of analyte detectable, while the relative limit of detection refers to the minimum concentration of analyte detectable. These concepts and their differences are obviously familiar to all analytical spectroscopists. Nevertheless, the two definitions are used liberally in the literature. For example, it is not uncommon to refer to exceptional sub-femtograms detection limits for a technique used to analyse ultratrace levels of an element in water and to a modest part per million detection limit of another technique used to characterise the microdistribution of an element in a sample mass of about one microgram. In this paper, an attempt is made to point out that the terms "ultratrace analysis" and "microanalysis" must refer to two conceptually different approaches and that there are cases in which one definition is more appropriate than the other. It is argued that, while there is no objection in reporting both detection limits when a single technique is evaluated, one has to be careful in choosing the most appropriate definition when different analytical techniques are compared.

Journal Article↗

Hydrazine detection limits in the cigarette smoke matrix using infrared tunable diode laser absorption spectroscopy.

Infrared absorption lines of hydrazine are broad and typically not baseline resolved, with line strengths approximately 100 times weaker than the more widely studied compound ammonia. Hardware and software improvements have been made to a two-color infrared tunable diode laser (IR-TDL) spectrometer in order to improve the limit of detection (LOD) of hydrazine (N2H4) in the cigarette smoke matrix. The detection limit in the smoke matrix was improved from 25 parts-per-million-by-volume (ppmv) to 4.2 ppmv using a 100 m pathlength cell with acquisition of background spectra immediately prior to each sample and 100 ms temporal resolution. This study did not detect hydrazine in cigarette smoke in the 964.4-964.9 cm(-1) spectral region, after mathematically subtracting the spectral contributions of ethylene, ammonia, carbon dioxide, methanol, acrolein, and acetaldehyde. These compounds are found in cigarette smoke and absorb in this spectral region. The LOD is limited by remaining spectral structure from unidentified smoke species. The pseudo random noise (root mean square) in the improved instrument was 2 x 10(-4) absorbance units (base e) which is equivalent to a 0.09 ppmv hydrazine gas sample in the multipass cell. This would correspond to a detection limit of 0.44 ppmv of hydrazine, given the dilution of the smoke by a factor of 5 by the sampling system. This is a factor of 10 less than the 4.2 ppmv detection limit for hydrazine in the smoke matrix, and indicates that the detection limit is primarily a result of the complexity of the matrix rather than the random noise of the TDL instrument.

Hydrazines↗

The limitations due to exposure detection limits for regression models.

Biomarker use in exposure assessment is increasingly common, and consideration of related issues is of growing importance. Exposure quantification may be compromised when measurement is subject to a lower threshold. Statistical modeling of such data requires a decision regarding the handling of such readings. Various authors have considered this problem. In the context of linear regression analysis, Richardson and Ciampi (Am J Epidemiol 2003;157:355-63) proposed replacement of data below a threshold by a constant equal to the expectation for such data to yield unbiased estimates. Use of such an imputation has some limitations; distributional assumptions are required, and bias reduction in estimation of regression parameters is asymptotic, thereby presenting concerns about small studies. In this paper, the authors propose distribution-free methods for managing values below detection limits and evaluate the biases that may result when exposure measurement is constrained by a lower threshold. The authors utilize an analytical approach and a simulation study to assess the effects of the proposed replacement method on estimates. These results may inform decisions regarding analytical plans for future studies and provide a possible explanation for some amount of the discordance seen in extant literature.

Bias↗

Efficient design and analysis of biospecimens with measurements subject to detection limit.

Pooling biospecimens is a well accepted sampling strategy in biomedical research to reduce study cost of measuring biomarkers, and has been shown in the case of normally distributed data to yield more efficient estimation. In this paper we examine the efficiency of pooling, in the context of information matrix related to estimators of unknown parameters, when the biospecimens being pooled yield incomplete observations due to the instruments' limit of detection. Our investigation of three sampling strategies shows that, for a range of values of the detection limit, pooling is the most efficient sampling procedure. For certain other values of the detection limit, pooling can perform poorly.

Analytic Sample Preparation Methods↗

Comparison of detection limits, for two metallic matrices, of laser-induced breakdown spectroscopy in the single and double-pulse configurations.

Limits of detection have been studied for several elements in aluminium and steel alloys, at atmospheric pressure in air, by use of the single and collinear double-pulse configurations of laser-induced breakdown spectroscopy. For this purpose, calibration plots were constructed for Mg, Al, Si, Ti, Cr, Mn, Fe, Ni, and Cu using a set of certified aluminium alloy samples and a set of certified steel samples. The investigation included optimization of the experimental conditions to furnish the best signal-to-noise ratio. Inter-pulse delay, gate width, and acquisition delay were studied. The detection limits for the elements of interest were calculated under the optimum conditions for the double-pulse configuration and compared with those obtained under the optimum conditions for single-pulse configuration. Significantly improved detection limits were achieved, for all the elements investigated, and in both aluminium and steel, by use of the double-pulse configuration. The experimental findings are discussed in terms of the measured plasma conditions (particle and electron density, and temperature).

Journal Article↗

Subnanomolar detection limit for sodium dodecyl sulfate-capillary gel electrophoresis using a fluorogenic, noncovalent dye.

Picomolar limits of detection are obtained using the noncovalent, fluorogenic dye, Sypro Red. The size separation of four commonly used sodium dodecyl sulfate-capillary gel electrophoresis (SDS-CGE) molecular weight markers with 8% linear polyacrylamide (PAA) as the sieving matrix is used to construct a calibration curve for molecular weight determinations. SDS-CGE purity and molecular weight determination of purified chorismate mutase-prephenate dehydrogenase (CMPD) from Escherichia coli is shown to be comparable in accuracy with slab gel SDS-polyacrylamide gel electrophoresis (SDS-PAGE). A migration time precision study indicates excellent reproducibility. Sypro red labeling of SDS-bovine serum albumin (SDS-BSA) complexes at nanomolar protein concentrations suggests assay detection limits surpassing those of silver staining. This detectability exceeds that achieved in previous SDS-CGE laser-induced fluorescence studies. This approach is expected to be easily adapted for use with commercial polymer formulations and automated instrumentation.

Buffers↗

The use of health risk assessment to estimate desirable sampling detection limits.

The inclusion of non-detected chemicals in a health risk assessment may lead, in some cases, to estimated risks that exceed regulatory thresholds, because one must use the detection limit or half of the detection limit. This study presents a methodology which will allow one to estimate appropriate detection limits by conducting a health risk assessment prior to the source sampling program. The advantages and shortcomings of various levels of detail in the risk assessment to determine those detection limits are discussed. The application of the methodology is demonstrated with a case study of the potential health effects of power plant stack emissions.

Environmental Monitoring↗

Rational design of potentiometric trace level ion sensors. A Ag+-selective electrode with a 100 ppt detection limit.

Submicromolar to picomolar lower detection limits have recently been obtained with various polymer membrane ion-selective electrodes by minimizing biases due to ion fluxes through the membrane. For the best performance, the compositions of the membrane and inner solution should be optimized for each application. Given the number of parameters to be adjusted, it has been difficult to find the best parameters for a target sample. In this paper, a much simplified and more practical steady-state model of zero-current ion fluxes is derived, which is based on measurable parameters. The model allows one to predict achievable lower detection limits for a membrane with given selectivities. It can also be used to predict the optimal composition of the inner filling solution for the measurement of samples with a known, typical ionic background. Selectivity coefficients of monovalent and divalent analyte ions required for desired detection limits in drinking water are calculated. As an application of the proposed general recipe, a silver-selective electrode is developed on the basis of the ionophore O,O''-bis[2-(methylthio)ethyl]-tert-butylcalix[4]arene. With the predicted optimal composition of the inner electrolyte, its lower detection limit is found to be 10(-9) M or 100 ppt Ag+ with an ionic background of 10(-5) M LiNO3, which is very close to the expected value.

Cations, Divalent↗

Comparison of various detection limit estimates for volatile sulphur compounds by gas chromatography with pulsed flame photometric detection.

This paper addresses the variations that presently exist regarding the definition, determination, and reporting of detection limits for volatile sulphur compounds by gas chromatography with pulsed flame photometric detection (GC-PFPD). Gas standards containing hydrogen sulphide (H(2)S), carbonyl sulphide (COS), sulphur dioxide (SO(2)), methyl mercaptan (CH(3)SH), dimethyl sulphide (DMS), carbon disulphide (CS(2)), and dimethyl disulphide (DMDS) in concentrations varying from 0.36ppb (v/v) up to 1.5ppm (v/v) in nitrogen were prepared with permeation tubes and introduced in the gas chromatograph using a 0.25-ml gas sampling loop. After measuring the PFPD response versus concentration, the method detection limit (MDL), the Hubaux-Vos detection limit (x(D)), the absolute instrument sensitivity (AIS), and the sulphur detectivity (D(s)) were determined for each sulphur compound. The results show that the MDL determined by the US Environmental Protection Agency procedure consistently underestimates the minimum concentrations of volatile sulphur compounds that can be practically distinguished from the background noise with the PFPD. The Hubaux-Vos detection limits and the AIS values are several times higher than the MDL, and provide more conservative estimates of the lowest concentrations that can be reliably detected. Sulphur detectivities are well correlated with AIS values but only poorly correlated with MDL values. The AIS is recommended as a reliable and cost-effective measure of detection limit for volatile sulphur compounds by GC-PFPD, since the AIS is easier and faster to determine than the MDL and the Hubaux-Vos detection limit. In addition, this study confirmed that the PFPD response is nearly quadratic with respect to concentration for all volatile sulphur compounds.

Chromatography, Gas↗

Detection limit of isotope dilution mass spectrometry.

The detection limit is an important figure of merit for evaluating instrumentation and analytical methods. While the detection limit for techniques using linear calibration functions has been studied extensively, this fundamental metric has rarely been discussed for mass spectrometry that bases the calibration on the principle of isotope dilution. We have developed a formulation for the detection limit for isotope dilution mass spectrometry (IDMS) after a thorough analysis of the uncertainty of IDMS measurements. The new formulation describes the IDMS detection limit as a function of the enrichment of the isotopic spike and the linear calibration detection limits measured at the masses for the isotope ratio measurement.

Journal Article↗

Extending the detection limit of the TDx fluorescence polarization immunoassay for benzoylecgonine in urine.

This modified calibration method decreases from 300 to 27 micrograms/L the limit of detection for the cocaine metabolite (hydrolysis product), benzoylecgonine, by the Abbott Laboratories TDx fluorescence polarization immunoassay. For this determination we used 30 controls prepared from a single urine pool known to be negative for cocaine metabolite. Assay of 80 controls prepared from 20 different patients' urine samples yielded a limit of detection of 44 micrograms/L. To test these limits of detection, we analyzed 90 patients' urine samples known to be negative for cocaine metabolite and 74 patients' samples known to be positive for cocaine metabolite, using the TDx with our revised calibration. Results for two of the known negative samples and 96% of the samples containing cocaine in the 50 to 100 micrograms/L range fell above the 44 micrograms/L limit. The TDx showed excellent calibration stability. For 28 days during the test, the instrument was not recalibrated. During this period the day-to-day analysis of 50 micrograms/L controls produced a mean TDx response of 0.485 (SD 0.007) with a coefficient of variation of 1.5%.

Autoanalysis↗

An immunoassay for small analytes with theoretical detection limits.

A flow-based immunoassay that uses microspheres as the solid phase accomplished the theoretical limit of detectability achievable with the antibody. An equilibrated mixture of anti-estriol monoclonal antibody and estriol was briefly exposed to a bead pack containing immobilized estriol in a flow cell. A small portion of free antibody was separated rapidly from the mixture by binding it to immobilized hormone, but the antibody-hormone complex was kinetically excluded from binding. This rapid separation prevented shift in the equilibrium of the liquid phase binding. Signals were generated by labeling the separated antibodies on the beads with a Cy5-conjugated antispecies secondary antibody. By labeling after the separation step, perturbing the liquid-phase or solid-phase binding was prevented. This assay allowed the reduction of the concentration of primary antibody by continuously accumulating free antibody onto the beads prior to quantification and, thus, offered ideal conditions to achieve theoretical limits of detectability. The optimum achievable dynamic range of this immunoassay was 4-300 pM. Because the proportion of free anti-estriol antibody in the mixture was controlled by the Kd of the antibody-estriol interaction, when the concentration of the antibody was below the Kd, the smallest detectable estriol concentration approached the theoretical limit of detectability achievable with this antibody.

Antibodies, Monoclonal↗