Search PubMedSearch

SEARCH · Search PubMed

Results for “Lens Implantation, Intraocular”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

39 recordsLinked to original sources

Risk Factors and Predictive Model for Postoperative High Myopia in Children Undergoing Congenital Cataract Surgery With Intraocular Lens Implantation.

PURPOSE: To identify risk factors associated with the development of high myopia following congenital cataract surgery and to establish a robust predictive model. DESIGN: Retrospective clinical cohort study. SUBJECTS: This retrospective study included 106 pediatric patients who underwent congenital cataract surgery with primary IOL implantation (mean follow-up 8.19 years). The model was externally validated in an independent cohort of 72 patients with a mean follow-up of 7.83 years. METHODS: Preoperative and postoperative ocular biometric parameters were collected. Risk factors for postoperative high myopia were analyzed using Cox proportional hazards regression, which served as the basis for model construction. The predictive performance of the model was rigorously evaluated for discrimination and calibration. Discriminative ability was quantified using Harrell's C-index and the area under the receiver operating characteristic curve (AUC). Model calibration was assessed via calibration plots by comparing predicted probabilities with actual observed outcomes. Internal validation was performed using a bootstrapping method (500 iterations) to ensure model stability and adjust for potential overfitting. RESULTS: An initial postoperative refraction of <+0.75D, and a higher IOL Power to Axial length Ratio (IOL/AL ratio) were identified as significant risk factors for the development of postoperative high myopia. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. The predictive model demonstrated robust performance, achieving a C-index of 0.711 (internal validation C-index: 0.713). The area under the receiver operating characteristic curve (AUC) values for predicting high myopia at 5 and 10 years were 0.858 and 0.745, respectively. Furthermore, calibration curves demonstrated excellent agreement between the predicted and observed outcomes throughout the follow-up period. In external validation, the model achieved a C-index of 0.825, 5-year AUC of 0.833, and 10-year AUC of 0.713. CONCLUSIONS: Our analysis established that initial postoperative refraction <+0.75D, and an elevated IOL/AL ratio are key determinants of high myopia risk following surgery. Shorter preoperative axial length was associated with a greater magnitude of postoperative myopic shift. This predictive framework provides clinicians with a practical tool to optimize preoperative IOL selection and identify high-risk infants who require vigilant myopia prevention and balanced amblyopia management.

Humans

Axial Length Adjustment and AL/R Ratio Optimization of IOL Power Calculation in Extremely Long Eyes.

PURPOSE: To evaluate the accuracy of modern intraocular lens (IOL) power calculation formulas and axial length (AL) adjustment methods in eyes with AL &#x2265; 30.0 mm. DESIGN: Retrospective consecutive cross-sectional study. PARTICIPANTS AND CONTROLS: A total of 308 eyes (308 patients) with AL &#x2265; 30.00 mm were included. METHODS: Accuracy of modern online formulas, alone or with established AL adjustments methods, was analyzed. Subgroup analyses were performed based on AL, keratometry (K), anterior chamber depth (ACD), lens thickness (LT), and AL-to-corneal radius (AL/R) ratio. MAIN OUTCOME MEASURES: Predictive accuracy was evaluated using the formula performance index (FPI), root mean square absolute prediction error (RMSAE), standard deviation (SD) of prediction error (PE), and percentage of eyes within &#xb1;0.25 and &#xb1;0.50 diopters (D). RESULTS: Overall, Holladay 1 combined with the nonlinear polynomial Wang-Koch axial length adjustment (H1-PWK) demonstrated the best overall performance, achieving the lowest SD (0.40), RMSAE (0.40), and highest FPI (0.494). A tendency toward hyperopic error was observed in eyes with AL &#x2265; 32.0 mm, K &#x2265; 46.0 D. The AL/R ratio showed a significant positive correlation with PE in the Ladas Super formula, Barrett Universal II, EVO, PEARL-DGS, and Hoffer QST formulas. Spline-based regression analysis indicated that the transition point of AL/R from myopic to hyperopic PE varied across different formulas. CONCLUSIONS: H1-PWK provides robust refractive accuracy in extremely long eyes. The AL/R ratio may provide a useful composite biometric stratification parameter compared to AL alone.

Humans

Glaucoma filtering surgery combined with phacoemulsification in the era of new aqueous humor filtration devices: A systematic review.

We evaluate the efficacy and safety of filtering glaucoma surgeries combined with phacoemulsification (PCE)-including new aqueous humor drainage devices-compared to standalone procedures. We performed a systematic search up to March 23, 2025, including all comparative studies assessing trabeculectomy (TRAB), non-penetrating deep sclerectomy (NPDS), Xen&#xae; Gel Stent (XEN), or Preserflo&#xae; MicroShunt (PMS) combined with PCE, versus the same surgery alone. Key exclusion criteria include inadequate follow-up (less than 12-month), absence of a defined success criterion, more than 50% of loss to follow-up at 12-month, and lens extraction performed without PCE. Main outcome was surgical success at &#x2265;&#x202f;12 months. Secondary outcomes included intraocular pressure (IOP) reduction, decrease in hypotensive medications, and rates of complications. A total of 27 studies were included for analysis. Among studies comparing TRAB/PCE with standalone TRAB, half reported similar success rates, while others favored standalone TRAB, particularly using strict IOP thresholds. Safety profiles were comparable. For NPDS/PCE, data mostly showed equivalent outcomes versus standalone NPDS, with comparable safety. In studies on XEN/PCE and PMS/PCE, results suggested similar rates of surgical success, efficacy in IOP and medication reduction, and safety compared to their stand-alone procedures. Small differences occasionally favored standalone procedures under stricter success definitions. Current evidence suggests that combined filtering glaucoma surgery provides long-term efficacy and safety comparable to standalone, though some subgroups and outcome thresholds may slightly favor standalone approaches. The limited availability of high-quality prospective trials underscores the need for further large-scale robust studies.

Humans

Impact of Contact Lens Use on Clinical Profile and Outcomes of Fungal Keratitis: An 8-Year Retrospective Study.

PURPOSE: To compare clinical characteristics, microbiological profiles, treatment strategies, and outcomes between contact lens-associated (CL) and noncontact lens-associated (non-CL) fungal keratitis. DESIGN: Retrospective, comparative clinical cohort study. METHODS: A review of culture-proven fungal keratitis treated at a tertiary referral center between 2018 and 2025 was conducted. Cases were categorized as CL or non-CL-associated. Demographic, clinical, microbiological, treatment, and outcome data were analyzed and compared between groups. RESULTS: Thirty-seven eyes were included, comprising 16 CL and 21 non-CL cases. CL users presented earlier than non-CL patients (median 7 vs 14 days, P = .007) and had fewer associated ocular risk factors (31% vs 81%, P = .001). Baseline visual acuity and infiltrate size did not differ significantly between groups. Candida species were isolated in 21% cases, Fusarium in 16% and Aspergillus in 8%. Fusarium (19% vs 13%) and Candida (24% vs 19%) infections were slightly more frequent in non-CL cases. Overall, filamentous fungi were the predominant organism group. Topical voriconazole was the most frequently used antifungal agent (78%). All CL-associated cases resolved with medical therapy alone, with a median time to resolution of 38 days (IQR 22-58). In contrast, 76% of non-CL cases resolved medically (median 42 days, IQR 32-76), while 23% required therapeutic keratoplasty (P = .04). Final visual acuity was comparable between groups (logMAR 0.2 vs 0.5, P = .56). CONCLUSION: Contact lens-associated fungal keratitis is characterized by earlier presentation and fewer underlying ocular comorbidities, with favorable outcomes achieved through medical therapy alone. Despite similar microbiological profiles and treatment approaches, noncontact lens-associated fungal keratitis more frequently follows a complicated course requiring surgical intervention.

Humans

Clinical Utility of Ultra-Widefield Swept-Source OCT for Intraocular Tumors: Comparison With Ultrasonography, SD-OCT, and MRI.

PURPOSE: To evaluate the clinical performance of ultra-widefield swept-source optical coherence tomography (UWF-OCT) in the assessment of choroidal tumors and to compare it with ultrasonography (US), spectral-domain (SD)-OCT, and magnetic resonance imaging (MRI). DESIGN: Retrospective diagnostic comparison. SUBJECTS: Thirty-nine eyes from 39 patients diagnosed with choroidal tumors at a single tertiary referral center. METHODS: This retrospective diagnostic comparison evaluated patients diagnosed with choroidal tumors at a single tertiary referral center between January 2023 and August 2025. All patients underwent UWF-OCT imaging at diagnosis. Tumor measurements obtained with UWF-OCT were compared with US, SD-OCT, and MRI. Comparative analysis among imaging modalities and predictors affecting UWF-OCT applicability was performed. MAIN OUTCOME MEASURES: Tumor thickness (mm) and largest basal diameter (LBD, mm) measurements, and complete measurability rate across different tumor size categories. RESULTS: Thirty-nine eyes from 39 patients (mean age 59.2 &#xb1; 16.9 years) were analyzed, including 27 choroidal melanomas (69.2%), 5 metastatic tumors (12.8%), 4 hemangiomas (10.3%), 2 osteomas (5.1%), and 1 (2.6%) indeterminate choroidal melanocytic lesion. UWF-OCT successfully measured both tumor thickness and largest basal diameter (LBD) in 100% (31/31) of small and medium choroidal tumors, substantially outperforming SD-OCT (complete measurement achieved in 63.6% of small tumors, and 0% of medium or large tumors). UWF-OCT measurements were systematically smaller than ultrasonography (thickness: -32.3%, P < .01; LBD: -11.1%, P < .01) and MRI (thickness: -29.2%, P < .01). Mushroom-shaped tumor morphology was the strongest negative predictor of UWF-OCT quality (OR = 0.015, 95% CI 0.001-0.196, P < .01). UWF-OCT's complete measurability was limited in large tumors (12.5%, 1/8). CONCLUSIONS: UWF-OCT provides precise, noninvasive, single-scan assessment of small-to-medium choroidal tumors with detailed structural visualization. It may be particularly useful for dome-shaped tumors, while multimodal imaging with US and MRI remains optimal for complex morphologies. Overall, UWF-OCT represents a valuable tool for diagnosis and treatment planning, with potential utility for longitudinal follow-up in choroidal tumor management.

Humans

Postoperative hypotony after retinectomy in rhegmatogenous retinal detachment surgery: A systematic review and meta-analysis.

We estimate the incidence of postoperative hypotony after retinectomy performed during rhegmatogenous retinal detachment surgery and explore clinical, surgical, and methodological factors associated with hypotony risk. We include human clinical studies reporting postoperative intraocular pressure (IOP) outcomes after retinectomy or retinotomy for retinal detachment. Postoperative hypotony was defined as IOP &#x2264;&#x202f;6&#x202f;mmHg, with alternative thresholds (&#x2264;5 or &#x2264;3&#x202f;mmHg) retained for sensitivity analyses. A random-effects meta-analysis was used to pool hypotony incidence, with prespecified subgroup and sensitivity analyses according to retinectomy extent, tamponade strategy, hypotony definition, assessment timepoint, and vitrectomy gauge size. Study-level associations with visual outcomes and proliferative vitreoretinopathy (PVR) severity were also explored. Thirty-three studies comprising 2673 eyes were included. The pooled incidence of postoperative hypotony was 13.71% (95% CI, 10.40-17.40), with substantial heterogeneity (I&#xb2; = 83.2%). Hypotony incidence did not increase linearly with retinectomy extent, and similar rates were observed for extents of 180&#xb0;-269&#xb0; and &#x2265;&#x202f;270&#xb0;. Stricter hypotony definitions and later postoperative assessment timepoints were associated with a higher reported incidence. A significant negative association was observed between hypotony incidence and visual improvement rates (Spearman &#x3c1; = -0.47, p&#x202f;=&#x202f;0.03). In contrast, no significant study-level difference in hypotony incidence was observed according to PVR severity grouping or vitrectomy gauge size. Postoperative hypotony after retinectomy is a frequent and clinically relevant complication, moderately associated with poorer visual outcomes and influenced by methodological factors rather than retinectomy extent alone.

Humans

Ciliochoroidal Effusion and Regional Scleral Thickening in Peripapillary Pachychoroid Syndrome.

PURPOSE: To assess anterior scleral thickness and the presence of ciliochoroidal effusion (CE) in eyes with peripapillary pachychoroid syndrome (PPS), and to compare the results with a cohort of healthy age-matched controls. DESIGN: Retrospective cross-sectional study METHODS: A total of 20 eyes from 12 patients diagnosed with PPS and 30 eyes from 15 healthy control subjects. All participants underwent a comprehensive ophthalmic examination, including spectral-domain optical coherence tomography with enhanced depth imaging (EDI-OCT) and anterior segment OCT (AS-OCT). Choroidal thickness was measured at predefined macular and peripapillary locations, while anterior scleral thickness was assessed 6 mm posterior to the scleral spur in 4 quadrants. Ciliochoroidal effusion was evaluated qualitatively using AS-OCT. Comparisons between groups were performed using linear mixed models with Bonferroni correction (scleral thickness corrected P < .010) RESULTS: The mean age of PPS patients was 75.6 &#xb1; 9.8 years, and 16% were females. Anterior scleral thickness was significantly greater in the temporal quadrant in PPS eyes compared to controls (396.85 &#xb1; 74.97 &#xb5;m vs 331.13 &#xb1; 62.65 &#xb5;m: P = .007). Ciliochoroidal effusion was detected in 60% of PPS eyes, predominantly in the superior and temporal sectors, whereas no effusion was observed in healthy controls (P < .001). Eyes with CE exhibited a thicker mean scleral thickness and a thicker subfoveal choroidal thickness compared to eyes without effusion (P < .05). CONCLUSION: Eyes with PPS demonstrated increased temporal scleral thickness and a high prevalence of CE. These findings suggest that scleral characteristics may represent a predisposing anatomical factor in PPS, although the precise pathophysiological mechanisms remain to be elucidated.

Humans

Association Between 24-Hour Blood Pressure and Rates of Retinal Nerve Fiber Layer Progression in Glaucoma: The Vascular Imaging in Glaucoma Study.

PURPOSE: Low systemic blood pressure (BP) has been implicated as a risk factor for glaucoma progression. The purpose of this study was to investigate the association between 24-hour BP and rates of retinal nerve fiber layer (RNFL) loss in eyes with primary open-angle glaucoma. DESIGN: Prospective cohort study. PARTICIPANTS: Seventy-nine eyes from 42 subjects with glaucoma (mean age, 68.5 &#xb1; 7.6 years) enrolled in the Vascular Imaging in Glaucoma Study at the Bascom Palmer Eye Institute. METHODS: Participants underwent 24-hour ambulatory BP monitoring at baseline. Follow-up evaluations were conducted at 4-month intervals and included ophthalmic examination, BP measurement, and peripapillary RNFL thickness measurement with spectral-domain optical coherence tomography. The association between BP and RNFL loss over time was assessed using linear mixed-effects models adjusted for age, sex, race, baseline RNFL thickness, central corneal thickness, and intraocular pressure. MAIN OUTCOME MEASURES: The effect of baseline 24-hour mean arterial pressure (MAP), systolic BP (SBP), and diastolic BP (DBP) on the rate of average RNFL loss over time. RESULTS: Eyes underwent an average of 13 &#xb1; 3 optical coherence tomography exams over 43 &#xb1; 10 months of follow-up. The mean rate of RNFL loss was -0.34 &#xb1; 0.64 &#xb5;m/y (median: -0.32; interquartile range: -0.66 to -0.04 &#xb5;m/y). After adjusting for confounding factors, every 10 mm Hg lower in 24-hour minimum MAP, SBP, and DBP was associated with -0.542 &#xb5;m/y (P < .001), -0.360 &#xb5;m/y (P = .003), and -0.458 &#xb5;m/y (P = .008) faster RNFL loss, respectively. Eyes in the lowest quartile of average 24-hour MAP (81-90 mm Hg) and minimum 24-hour DBP (35-47 mm Hg) experienced significantly faster progression compared to those in the highest quartile, with differences of -0.68 &#xb5;m/y (P = .017) and -0.63 &#xb5;m/y (P = .030), respectively. CONCLUSIONS: Lower systemic BP, especially minimum MAP, SBP, and DBP measured by 24-hour ambulatory BP monitoring, is associated with faster rates of RNFL loss in primary open-angle glaucoma eyes. 24-hour BP monitoring may help predict glaucoma patients at greater risk of progression.

Humans

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Influence of nicotine on protein expression around hydrophilic osseointegrated implants: A proteomic study in male rats.

OBJECTIVE: To ensure the success of dental implant treatment, various factors must be considered, including osseointegration and systemic conditions. There is evidence in the literature that smokers may exhibit alterations in tissue healing, which can compromise the success of implant rehabilitation. Therefore, this study aimed to investigate the influence of nicotine on the protein profile of bone tissue around hydrophilic implants during the osseointegration process in rats. DESIGN: Bone tissue samples from the control and nicotine groups (n&#x202f;=&#x202f;3 per group) were subjected to protein extraction, mass spectrometry, and bioinformatic analyses. Protein identification was performed using Proteome Discoverer 2.1 software and the SEQUEST algorithm, and the protein data were compared with those of a protein database of Rattus norvegicus obtained from UniProt. RESULTS: A total of 740 proteins were detected in both the control group and the nicotine-exposed group. Among them, the proteins biglycan, periostin and histone H4 were highlighted because of their higher abundance in the healthy implant group, while they were reduced in the nicotine-exposed group. CONCLUSIONS: Nicotine has the potential to alter the protein profile of bone tissue around hydrophilic implants during osseointegration, which may impair tissue remodeling and healing.

Animals

Assessment of Surgical Salvage Outcomes for Exposed Cranial Neuromodulating Devices.

OBJECTIVES: Implanted neuromodulating devices (NMDs) such as cochlear implants (CIs) and deep brain stimulators (DBSs) are commonly used in modern medicine. Rarely, complications arise post-operatively, including hardware exposure. Traditional teaching suggests that these devices require removal if exposed; however, surgical salvage is a high risk, high reward alternative. We review our single institution experience managing NMD exposure with surgical salvage. METHODS: Retrospective chart review was performed on individuals who had a NMD implanted and underwent an attempt at surgical salvage for exposure during the study period (January 01, 2021 through December 31, 2023). Study outcome success was defined as maintaining a functional NMD 1&#x2009;year after salvage was attempted. Surgical techniques associated with successful salvage were compared. RESULTS: Nine of 729 patients (1.2%) implanted with NMDs experienced hardware exposure during this 2-year study period. Nine subjects were referred for NMD salvage; however, only 6 of 9 subjects (66.7%, CI&#x2009;=&#x2009;3; DBS&#x2009;=&#x2009;3) underwent NMD salvage attempts. Four of the subjects had successful salvage demonstrated successful salvage with a functioning NMD and without wound healing concerns 1&#x2009;year after their salvage procedure. CONCLUSIONS: Classic teaching states that exposed NMDs require explantation. However, this approach necessarily imposes time without benefit from the NMD between explantation and reimplantation. Our experience demonstrates that surgical salvage can be a successful alternative for the majority (66.7%) of individuals.

Humans

Proteomic insights into the immunomodulatory effects of Ca/Sr co-doped sol-gel coatings for titanium implants.

Ionic functionalization of biomaterial coatings has emerged as a powerful strategy to regulate early host responses at the implant interface. However, how combined Ca/Sr incorporation governs the adsorbed proteome and downstream immune signaling remains poorly understood. This study analyses, employing in vitro tests and proteomics, the effect of adding Sr and Ca to Si-based coatings designed to bioactivate Ti implants. Hybrid Si-based coatings were synthesized by the sol-gel route with a fixed Ca content (0.5&#x202f;wt%) and increasing Sr contents (0.5, 1.0, 1.5&#x202f;wt%), and their physicochemical properties, ion release kinetics, and hydrolytic stability were characterized. The coatings remained highly crosslinked despite Ca/Sr incorporation, whereas the highest Sr content increased hydrolytic degradation to around 70% after 56 days. Proteomic analysis identified 183 adsorbed proteins, of which 56 were differentially adsorbed on Ca/Sr-coatings, mainly associated with immune and coagulation pathways. In vitro, RAW 264.7 showed increased gene expression of TNF-&#x3b1; and TGF-&#x3b2;; with an enhanced TNF-&#x3b1; secretion by the addition of Ca and Sr. In parallel, MC3T3-E1 indicated that Ca/Sr-coatings were not cytotoxic and did not impair cell proliferation. However, ALP activity was reduced in the co-doped groups, indicating that the immunomodulatory effects induced by Ca/Sr incorporation were not accompanied by enhanced early osteogenic differentiation. The Ca/Sr combination induced alterations in the adsorption of immune-related proteins, which correlated with the in vitro findings. The deeper insight into how Ca/Sr mixtures modulate protein adsorption on biomaterial surfaces may be key to understanding the immunomodulatory capacity of these bioactive cations.

Animals

Cochlear Implantation in Sickle Cell Disease: A Systematic Review of Feasibility and Outcomes.

INTRODUCTION: Sickle cell disease (SCD) is associated with systemic complications, including sensorineural hearing loss (SNHL) from microvascular occlusion and chronic inflammation. Although reports link SCD to higher rates of SNHL, current evidence is limited by small sample size, varied audiologic methods, and lack of standardized screening. This systematic review summarizes available literature on SNHL and cochlear implantation (CI) in SCD. METHODS: A literature search of PubMed MEDLINE, Embase, Scopus, Web of Science, and CINAHL identified 79 citations. After removal of duplicates, 35 records were screened in Rayyan. Studies published between January 1, 2000, and June 30, 2025, were eligible if they reported patients with SCD who developed hearing loss and underwent CI. Nine full texts were reviewed, and 4 met the inclusion criteria. Screening and review were performed independently by 2 authors per PRISMA guidelines. RESULTS: Across 4 case reports, a total of 5 patients with SCD underwent CI, ranging in age from 2 to 42 years. Four presented with bilateral severe-to-profound SNHL and one with unilateral loss. Implantation was technically feasible in all cases, including patients with cochlear fibrosis or ossification requiring modified insertion techniques. Postoperative outcomes were favorable: all patients demonstrated reliable device function and low impedances. Only 60% showed meaningful auditory benefit, characterized by improved functional speech perception in 2 patients (40%) and access to the speech frequency range with hearing testing going from moderate/profound hearing loss to mild hearing loss in 3 patients (60%). Complications occurred in 2 patients (40%): one developed unilateral middle ear infection leading to meningitis, and another experienced a postoperative pulmonary embolism requiring anticoagulation. The remaining 3 patients (60%) had uncomplicated recoveries with reported improved hearing from moderate/profound hearing loss to mild hearing loss post implantation. CONCLUSION: While CI appears feasible in SCD, our findings suggest that additional data are needed to assess its effectiveness in this patient population. However, evidence is limited to case reports, and complications such as thromboembolism and rapid cochlear fibrosis highlight the need for close perioperative management. More comprehensive studies with larger sample size are required to define surgical risk, optimize management, and establish best practices for timely implantation in this population.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Soft Tissue Volume Augmentation at Single Implant Sites Applying Collagen Matrices or Connective Tissue Grafts: 10-Year Follow-Up of a Randomized Controlled Trial.

AIM: To compare up to 10&#x2009;years clinical, profilometric and patient-reported outcomes of implant sites previously augmented using a volume-stable collagen matrix (VCMX) or connective tissue graft (SCTG) in the aesthetic zone. METHODS: The original non-inferiority randomized controlled trial (RCT) enrolled 20 patients who received soft tissue volume augmentation with VCMX or SCTG at single implant sites. Clinical assessments and standardized measurements were performed at baseline after crown insertion and at 6&#x2009;months, 1, 3, 5, 7.5, and 10&#x2009;years. The primary outcome was mucosal thickness. Secondary outcomes included marginal bone levels (MBL), probing depth (PD), bleeding on probing (BOP), plaque control record, Pink Aesthetic Score (PES), OHIP-14 and buccal profilometric changes. Group comparisons were performed using mixed-effects and generalized estimating equation (GEE) models, which account for within-patient correlations due to repeated measurements and allow inclusion of all available data without requiring imputation for missing observations. RESULTS: Of the 20 originally enrolled patients, 10 (5 in the SCTG group and 5 in the VCMX group) were available for re-examination at 10&#x2009;years. The adjusted between-group difference in mucosal thickness was -0.02&#x2009;mm (95% CI -0.99 to 0.96). As the lower bound of the confidence interval remained above the prespecified non-inferiority margin of -1&#x2009;mm, non-inferiority of VCMX was shown. Buccal contour changes were comparable during the early follow-up, while a trend toward a greater long-term contour decrease was observed in group VCMX (-0.31&#x2009;mm [95% CI, -0.65 to 0.03]; p&#x2009;=&#x2009;0.07). Mean PES values were 10.6 in the SCTG group and 9.6 in the VCMX group, with no significant between-group differences (p&#x2009;=&#x2009;0.45). Both groups revealed high levels of oral health-related quality of life, with low median OHIP-14 scores (SCTG, 0.0; VCMX, 1.0; p&#x2009;=&#x2009;0.26). CONCLUSION: These preliminary long-term findings showed no clinically relevant differences between SCTG and VCMX in terms of clinical, profilometric and patient-reported outcomes. While SCTG remains the reference standard, VCMX represents a less invasive alternative but with a slight tendency toward greater long-term contour reduction. CLINICAL SIGNIFICANCE: Volume-stable collagen matrices serve as a viable alternative to autogenous connective tissue grafts for peri-implant soft tissue volume augmentation, particularly in patients seeking a reduced morbidity, without compromising long-term clinical or aesthetic outcomes. TRIAL REGISTRATION: German Clinical Trials Register: DRKS00017484.

Humans