Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Lab-On-A-Chip Devices”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Multiport flow-control system for lab-on-a-chip microfluidic devices.

A multiport system suitable for pressure control on a lab-on-a-chip microfluidic device is described. An algorithm and a strategy for calculating pressures were developed to control the flow from multiple reservoirs for the microfluidic devices. Dye mixing and enzyme assay titration experiments were performed using pressure-driven flow only. Results show a good linear response over two orders of dynamic range.

Algorithms↗

Recent developments in electrokinetically driven analysis on microfabricated devices.

This review is devoted to the rapid developments in the field of microfluidic separation devices in which the flow is electrokinetically driven, and where the separation element forms the heart of the system, in order to give an overview of the trends of the last three years. Examples of microchip layouts that were designed for various application areas are given. Optimization of mixing and injection strategies, designs for the handling of multiple samples, and capillary array systems show the enormous progress made since the first proof-of-concept papers about lab-on-a-chip devices. Examples of functional elements for on-chip preconcentration, filtering, DNA amplification and on-chip detection indicate that the real integration of various analytical tasks on a single microchip is coming into reach. The use of materials other than glass, such as poly(dimethylsiloxane) and polymethylmethacrylate, for chip fabrication and detection methods other than laser-induced fluorescence (LIF) detection, such as mass spectrometry and electrochemical detection, are described. Furthermore, it can be observed that the separation modes known from capillary electrophoresis (CE) in fused-silica capillaries can be easily transferred to the microchip platform. The review concludes with an overview of applications of microchip CE and with a brief outlook.

Animals↗

On-chip electrophoretic accumulation of DNA oligomers and streptavidin.

A micro-chamber for electrophoretic accumulation of charged biomolecules has been designed and evaluated. The system is based on a chip with an array of planar focusing electrodes. Particular attention was devoted to a design which enables penetration of a large sample volume by the electric field of the focusing electrodes. General design principles for a cylindrically symmetrical arrangement of the focusing electrodes were derived. Accumulation of DNA oligomers and streptavidin in aqueous solution was demonstrated. The concentration of biomolecules in the centre of the chip was enhanced by up to a factor of 200. The major fraction of the total charge delivered during electrophoretic accumulation results from Faradaic processes. The maximum charge density deliverable without visible gas formation was determined. By careful control of the voltage and current density applied to the electrodes, evolution of gas bubbles could be avoided for the time required to accumulate analyte molecules in the centre of the micro-chamber. On-chip electrophoretic accumulation of biomolecules can be applied to sample pre-conditioning in lab-on-a-chip devices for analysis of DNA and protein samples.

Animals↗

Chips and Qi: microcomponent-based analysis in traditional Chinese medicine.

Over the last 50 years or so Traditional Chinese medicine (TCM) has been subject to intensive basic and clinical research. Although the effectiveness and remarkable safety of TCM have been documented after controlled clinical studies, there are several herbal and animal parts that are toxic or difficult to identify. DNA polymorphism-based assays have recently been developed for the identification of herbal medicines. In this approach, small amounts of DNA are amplified by the polymerase chain reaction and the reactions products are analyzed by gel electrophoresis, sequencing, or hybridization with species-specific probes. With the DNA based identification of TCM materials as an example, chip-based analytical micro devices were developed with the goal of fabricating an integrated device that will enable sample preparation, amplification, and analysis on a single microchip-based device ("lab-on-a-chip"). The application of a silicon-based polymerase chain reaction microreactor and a DNA microarray for the DNA sequence-based identification of toxic medicinal plants is reported here.

DNA, Plant↗

On-chip thermopneumatic pressure for discrete drop pumping.

A class of "lab-on-a-chip" devices use external air pressure for pumping discrete drops in a microchannel network. External air connectors can be cumbersome and are real-estate intensive. We have developed an on-chip technique to generate pressures required for metering and pumping of nanoliter-volume discrete drops. This is achieved by heating of trapped air in a pressure-generating chamber. The pressure-generating chamber is connected to the point of pressure application in the liquid-conveying microchannel through an air-delivery channel. The trapped air volume on the order of 100 nL is heated by resistive metal heaters by tens of degrees celcius to generate air pressures on the order of 7.5 kN/m2. The rate of discrete drop pumping is electronically controlled in the microchannel device by controlling the rate of air heating. Flow rates on the order of 20 nL/s are obtained in the microchannel (300 microns x 30 microns) by heating the air chamber at the rate of approximately 6 degrees C/s. In this paper, we describe the design, fabrication, and operation of this new technique of generating on-chip air pressure, used for metering and pumping nanoliter discrete drops in microchannels.

Air Pressure↗

DNA transport by a micromachined Brownian ratchet device.

We have micromachined a silicon-chip device that transports DNA with a Brownian ratchet that rectifies the Brownian motion of microscopic particles. Transport properties for a DNA 50-mer agree with theoretical predictions, and the DNA diffusion constant agrees with previous experiments. This type of micromachine could provide a generic pump or separation component for DNA or other charged species as part of a microscale lab-on-a-chip. A device with reduced feature size could produce a size-based separation of DNA molecules, with applications including the detection of single-nucleotide polymorphisms.

DNA↗

Recent advances in electrochemical detection in capillary electrophoresis.

Recent advances in the design and application of electrochemical (EC) detection systems in capillary electrophoresis (CE) are reviewed, with the objective of providing the nonelectrochemist with a state-of-the-art picture of CEEC instrumentation and an overview of the principal analytes for which CEEC is best suited. The detection schemes considered here include those based both on amperometry and on potentiometry as both kinds of EC systems are being actively developed in CE and have the potential for broad application in analysis. Over the three-year period covered by this review, an important direction that CEEC has taken is the construction of more complex electrode systems beginning with the use of multiple EC electrodes and culminating with the adaptation of EC detection to microfabricated "lab-on-a-chip" analysis devices. In addition, CEEC applications have now grown to include a broad variety of inorganic, organic, and biochemical analytes and samples.

Electrophoresis, Capillary↗

Bridging Organ-on-a-Chip and Omics: A Multi-Dimensional Frontier in Biomedical Research.

Organ-on-a-Chip (OOC) technology offers a powerful platform for replicating human tissue-specific microenvironments, thereby narrowing the translational gap between conventional biomedical models and actual human physiology. Concurrently, omics technologies deliver comprehensive molecular-level insights into biological systems. This review highlights the transformative potential of integrating OOC platforms with high-throughput omics methodologies. We systematically examine the classification, structural configurations, and engineering principles underlying OOC systems, alongside the defining attributes of key omics domains-genomics, transcriptomics, proteomics, and metabolomics. The convergence of dynamic OOC models with advanced omics technologies enables high-resolution, multi-dimensional analyses across numerous biomedical applications, including drug metabolism, disease mechanisms, environmental toxicity assessments, and host-microbiome interactions. This interdisciplinary integration is driving a paradigm shift in precision and translational medicine. However, several challenges remain to be addressed, such as the development of whole-organ mimetics, adaptation of sample collection techniques, and real-time artificial intelligence-based integration of biosensor data with multi-omics datasets. Addressing these hurdles will be vital for unlocking the full potential of this technological synergy in biomedical science.

Multiomics↗

Phase Transition of Wax Enabling CRISPR Diagnostics for Automatic At-Home Testing of Multiple Sexually Transmitted Infection Pathogens.

Sexually transmitted infections (STIs) significantly impact women's reproductive health. Rapid, sensitive, and affordable detection of these pathogens is essential, especially for home-based self-testing, which is crucial for individuals who prioritize privacy or live in areas with limited access to healthcare services. Herein, an automated diagnostic system called Wax-CRISPR has been designed specifically for at-home testing of multiple STIs. This system employs a unique strategy by using the solid-to-liquid phase transition of wax to sequentially isolate and mix recombinase polymerase amplification (RPA) and CRISPR assays in a microfluidic chip. By incorporating a home-built controlling system, Wax-CRISPR achieves true one-pot multiplexed detection. The system can simultaneously detect six common critical gynecological pathogens (CT, MG, UU, NG, HPV 16, and HPV 18) within 30 min, with a detection limit reaching 10-18 M. Clinical evaluation demonstrates that the system achieves a sensitivity of 96.8% and a specificity of 97.3% across 100 clinical samples. Importantly, eight randomly recruited untrained operators performe a double-blinded test and successfully identified the STI targets in 33 clinical samples. This wax-transition-based one-pot CRISPR assay offers advantages such as low-cost, high-stability, and user-friendliness, making it a useful platform for at-home or field-based testing of multiple pathogen infections.

Sexually Transmitted Diseases↗

Endodermal Organoids Along Two Axes: Single-Organ Fidelity, Inter-Organ Reconstruction, and the Unbuilt Gut-Lung Frontier.

Three-dimensional organoids of the gut, liver, and lung have become mainstream models of human development, disease, and therapy. These organs share an embryonic endodermal origin, yet the field measures their progress inconsistently because the word "maturity" carries two unrelated meanings. Herein, we review the organoid work across all three organs and propose that the two orthogonal axes of advancement be analyzed separately. The first axis is single-organ fidelity. Adult stem cell organoids are faithful but partial, reproducing the adult epithelium of their source tissue with genomic stability yet lacking stromal, vascular, immune, and neural compartments. Human pluripotent stem cell organoids are complete but immature, co-emerging with multiple lineages yet arrested in a fetal-like state. The cost of each limitation is organ-dependent, smallest in the intestine, largest for hepatic drug metabolism, and most spatially defined across the proximal and distal lungs. The second axis is inter-organ reconstruction, where progress is strongly asymmetric. The gut-liver axis is comparatively advanced and sustained by linked organoid and microphysiological systems. The gut-lung axis, by contrast, remains the least-developed frontier, and no such linked organoid has yet been built. We therefore frame it as a proposal, using in vivo and correlative evidence to outline the design principles for such a model. Four bottlenecks recur across both axes: limited vascularization; batch-to-batch variability; organ-skewed immune, microbial, and stromal microenvironments; and unidirectional signaling. We argue that benchmarking models against single-cell developmental atlases and prioritizing construction of the gut-lung frontier should guide the field over the next decade.

Intestines↗

Exploring the Translation of Organ-on-a-Chip Technology for Human-Relevant Diagnostic Biomarkers.

Microphysiological systems (MPSs) are gaining traction as a viable alternative model for toxicity studies. Further characterization is necessary to explore the full translational potential of MPSs to human physiology, along with the utility of these platforms to serve as a diagnostic tool. Multiomics analyses have emerged as a key means for identifying host biomarkers associated with chemical and drug exposure. Correlations between published human omics and MPS technology omics data will inform the potential of organ chips to accurately represent human responses and provide an alternative approach for improved biomarker discovery for toxicity assessment and exposure identification. To interrogate these potential overlaps, TissUse Chip3 multiorgan chips (MOCs) seeded with kidney organoids, liver organoids, and respiratory tract tissue were exposed to low, therapeutic, and toxic doses of acetaminophen (n = 4 for each condition) for 24 h and subjected to proteomic and metabolomic analysis. The data from our organ chips are largely consistent with biomarkers and dysregulations identified in published human omics data, in vitro and in vivo data, to include the identification of several known acetaminophen metabolites and biotransformation products. These data suggest that organ chips may be a suitable surrogate for human biomarker identification and drug or hazardous chemical exposure diagnosis.

Humans↗

Measuring single-cell susceptibility to antibiotics within monoclonal bacterial populations.

The emergence of new resistant bacterial strains is a worldwide challenge. A resistant bacterial population can emerge from a single cell that acquires resistance or persistence. Hence, new ways of tackling the mechanism of antibiotic response, such as single cell studies are required. It is necessary to see what happens at the single cell level, in order to understand what happens at the population level. To date, linking the heterogeneity of single-cell susceptibility to the population-scale response to antibiotics remains challenging due to the trade-offs between the resolution and the field of view. Here we present a platform that measures the ability of individual E. coli cells to form small colonies at different ciprofloxacin concentrations, by using anchored microfluidic drops and an image and data analysis pipelines. The microfluidic results are benchmarked against classical microbiology measurements of antibiotic susceptibility, showing an agreement between the pooled microfluidic chip and replated bulk measurements. Further, the experimental likelihood of a single cell to form a colony is used to provide a probabilistic antibiotic susceptibility curve. In addition to the probabilistic viewpoint, the microfluidic format enables the characterization of morphological features over time for a large number of individual cells. This pipeline can be used to compare the response of different bacterial strains to antibiotics with different action mechanisms.

Anti-Bacterial Agents↗

Microchips, microarrays, biochips and nanochips: personal laboratories for the 21st century.

Micro miniaturization of analytical procedures is having significant impact on diagnostic testing, and will enable highly complex clinical testing to be miniaturized and permit testing to move from the central laboratory into non-laboratory settings. The diverse range of micro analytical devices includes microchips, gene chips, bioelectronic chips. They have been applied to several clinically important assays (e.g., PCR, immunoassay). The main advantages of the new devices are integration of multiple steps in complex analytical procedures, diversity of application, sub-microliter consumption of reagents and sample, and portability. These devices form the basis of new and smaller analyzers (e.g., capillary electrophoresis) and may ultimately be used in even smaller devices useful in decentralized testing (lab-on-a-chip, personal laboratories). The impact of microchips on healthcare costs could be significant via timely intervention and monitoring, combined with improved treatments (e.g., microchip-based pharmacogenomic tests). Empowerment of health consumers to perform self-testing is limited, but microchips could accelerate this process and so produce a level of self-awareness of biochemical and genetic information hitherto unimaginable. The next level of miniaturization is the nanochip (nanometer-sized features) and the technological foundation for these futuristic devices is discernable in nanotubes and self-assembling molecular structures.

Miniaturization↗

Capillary electrophoresis chips with integrated electrochemical detection.

Capillary electrophoresis systems with integrated electrochemical detection have been microfabricated on glass substrates. Photolithographic placement of the working electrode just outside the exit of the electrophoresis channel provides high-sensitivity electrochemical detection with minimal interference from the separation electric field. Microchip electrophoretic separations of neurotransmitters in under 100 s exemplify the good resolution and attomole detection sensitivity of these devices. Using indirect electrochemical detection, high-sensitivity DNA restriction fragment and PCR product sizing has also been performed. These microdevices match the detector's size to that of microfabricated separation and reaction devices, bringing to reality the lab-on-a-chip concept.

DNA↗

A microfluidic device for measuring cellular membrane potential.

Recent developments in microfluidics have enabled the design of a lab-on-a-chip system capable of measuring cellular membrane potential. The chip accesses liquid samples sequentially by sipping from a microplate through a capillary, mixes the samples with cells flowing through a microchannel, contacts the cells with potential-sensitive dyes, and reads out cellular responses using fluorescence detection. The rate of cellular uptake of membrane-permeable, ionic fluorophores by THP-1 cells was found to depend strongly on membrane potential. The ratio of the fluorescence of the anionic dye DiBAC(4)(3) and the cationic dye Syto 62 taken up by cells was found to double for every 33 mV change in membrane potential. The utility of this approach was demonstrated by assaying ion channel activity in human T lymphocytes. Because of the high sensitivity, low cellular and reagent consumption, and high data quality obtained with the microfluidic device, the lab-on-a-chip system should be widely applicable in high-throughput screening and functional genomics studies.

Barbiturates↗

Microchip systems for immunoassay: an integrated immunoreactor with electrophoretic separation for serum theophylline determination.

A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 +/- 0.03 and an intercept of -0.04 +/- 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 micrograms/L at the detector) was obtained. Recovery values were 107% +/- 8% for 15 mg/L serum samples.

Automation↗

Cambridge Healthtech Institute's Third Annual Conference on Lab-on-a-Chip and Microarrays. 22-24 January 2001, Zurich, Switzerland.

Cambridge Healthtech Institute's Third Annual Conference on Lab-on-a-Chip and Microarray technology covered the latest advances in this technology and applications in life sciences. Highlights of the meetings are reported briefly with emphasis on applications in genomics, drug discovery and molecular diagnostics. There was an emphasis on microfluidics because of the wide applications in laboratory and drug discovery. The lab-on-a-chip provides the facilities of a complete laboratory in a hand-held miniature device. Several microarray systems have been used for hybridisation and detection techniques. Oligonucleotide scanning arrays provide a versatile tool for the analysis of nucleic acid interactions and provide a platform for improving the array-based methods for investigation of antisense therapeutics. A method for analysing combinatorial DNA arrays using oligonucleotide-modified gold nanoparticle probes and a conventional scanner has considerable potential in molecular diagnostics. Various applications of microarray technology for high-throughput screening in drug discovery and single nucleotide polymorphisms (SNP) analysis were discussed. Protein chips have important applications in proteomics. With the considerable amount of data generated by the different technologies using microarrays, it is obvious that the reading of the information and its interpretation and management through the use of bioinformatics is essential. Various techniques for data analysis were presented. Biochip and microarray technology has an essential role to play in the evolving trends in healthcare, which integrate diagnosis with prevention/treatment and emphasise personalised medicines.

Computational Biology↗

Electrophoresis in microfabricated devices using photopolymerized polyacrylamide gels and electrode-defined sample injection.

Microfabrication techniques have become increasingly popular in the development of the next generation of DNA analysis systems. While significant progress has been reported by many researchers, complete microfabricated integrated DNA analysis devices are still in the earliest stages of development. Most miniaturized analysis systems have incorporated noncross-linked polymer solutions as the separation medium of choice and the operation of these systems necessitates the use of high electric fields and long separation lengths. In this paper, we present two techniques that may help alleviate this problem and accelerate the development of the so-called 'lab-on-a-chip' systems. We present the use of photodefinable polyacrylamide gels as a sieving medium for DNA electrophoresis. These gels offer the significant advantages of faster curing times, locally controlled gel interface, and simpler handling over chemically polymerized gels. We also introduce an electrode-defined sample compaction and injection technique. This technique helps achieve sample compaction without migration into the gel and offers significant control over the size and application of the sample plug. The use of these technologies for double-stranded DNA separations in microfabricated separation systems is demonstrated.

Acrylic Resins↗