Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Kinesis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Assessment of left ventricular regional wall motion by color kinesis technique: comparison with angiographic findings.

The analysis of segmental wall motion using two-dimensional (2-D) echocardiography is subjective with high interobserver variability. Color kinesis is a new technique providing a color-encoded map of endocardial motion. We evaluated the accuracy of color kinesis and 2-D for assessment of regional asynergy compared with left ventricular angiography as a reference method. Fifteen patients admitted for myocardial infarction were studied by echocardiography the day before left ventricular angiography. The left ventricle was divided into seven segments. Each segment was classified by two independent observers as normal or abnormal in 2-D and color kinesis. Accuracy of color kinesis and 2-D was evaluated and compared to left ventricular angiography. Color kinesis is significantly superior to 2-D for all seven segments (mean 0.80/0.68, P = 0.05), except for the septum (0.67/0.60, P = NS). Interobserver variability studied by chi-square statistic is lower with color kinesis (0.70) than with 2-D (0.57). We conclude that these data suggest that color kinesis is a useful method for assessing systolic wall motion in all segments, except the septum and for improving the accuracy of segmental ventricular function and interobserver variability.

Adult↗

Automatic backscatter analysis of regional left ventricular systolic function using color kinesis.

Assessment of regional wall motion by 2-dimensional echocardiography can be performed by either semiquantitative wall motion scoring or by quantitative analysis. The former is subjective and requires expertise. Quantitative methods are too time-consuming for routine use in a busy clinical laboratory. Color kinesis is a new algorithm utilizing acoustic backscatter analysis. It provides a color encoded map of endocardial motion in real time. In each frame a new color layer is added; the thickness of the color beam represents endocardial motion during that frame. The end-systolic image has multiple color layers, representing regional and temporal heterogeneity of segmental motion. The purpose of this study was to validate the use of color kinesis for semiquantitative analysis of regional left ventricular systolic function and quantitatively in measurement of endocardial excursion. Semiquantitative wall motion scoring was performed in 18 patients using both 2-dimensional echo and color kinesis. Scoring was identical in 74% of segments; there was 84% agreement in definition of normal vs. abnormal. There was less interobserver variability in wall motion scoring using color kinesis. Endocardial excursion was quantified in 21 patients. 70% of the imaged segments were suitable for analysis. Correlation between 2-dimensional echocardiographic measurements and color kinesis was excellent, r = 0.87. The mean difference in excursion as measured by the 2 methods was -0.05 +/- 2.0 mm. In conclusion, color kinesis is a useful method for assessing regional contraction by displaying a color map of systolic endocardial excursion. This algorithm may improve the confidence and accuracy of assessment of segmental ventricular function by echocardiographic methods.

Adult↗

Assessment of left ventricular dyssynergy by color kinesis.

Color kinesis is a new echocardiographic technique based on acoustic quantification. It has been developed to facilitate the ability to identify contraction abnormalities and has been incorporated into a commercially available ultrasound imaging system. The potential of this technique to improve the qualitative and quantitative assessment of wall motion abnormalities is described. Evaluation of color-encoded images allows detection of decreased amplitude of endocardial motion in abnormally contracting segments as well as a shorter time of endocardial excursion in segments with severely decreased motion. Compared with off-line quantitative studies, color kinesis has the advantage to be used on-line, without time-consuming manual tracing of endocardial boundaries. In addition, a single end-systolic color image contains the entire picture of spatial and temporal contraction and can be digitally stored and retrieved. In patients with proven coronary artery disease, color kinesis had a sensitivity of 88%, a specificity of 77%, and an overall accuracy of 86% in identifying the presence of segmental dysfunction. The practical application of color kinesis might be to improve our ability to distinguish normal from hypokinesis, something that has always been difficult in clinical echocardiography. Segmental analysis of color kinesis images allows objective detection of dobutamine-induced regional wall motion abnormalities in agreement with conventional visual interpretation of the corresponding 2-dimensional views. A method for objective assessment of wall dynamics during dobutamine stress echocardiography would be of particular clinical value, because these images are even more difficult to interpret than conventional echocardiograms. Quantitative assessment of diastolic function may allow objective evaluation of segmental relaxation abnormalities, especially under conditions of pharmacologic stress testing. Acquisition of color kinesis images during dobutamine stress echocardiography, both transthoracic and transesophageal, may facilitate the assessment of hybernating but viable myocardium and enhance the sensitivity in the detection of coronary artery disease.

Echocardiography, Doppler, Color↗

Usefulness of color kinesis imaging for evaluation of regional right ventricular wall motion in patients with surgically repaired tetralogy of Fallot.

We evaluated regional right ventricular wall motion during systole in patients with surgically repaired tetralogy of Fallot (TOF) using color kinesis imaging. Color kinesis images were obtained in a subcostal sagittal view from 19 patients with repaired TOF (TOF group), aged 3 to 5 years, and 20 age-matched normal subjects (control group). For regional wall motion analysis, the endocardial motion distance and the fractional area change (FAC) were calculated for 6 segments obtained from color kinesis images. The endocardial inward excursion distances and the FACs in the upper, middle, and lower posterior segments of the TOF group were significantly greater than those of the control group (p <0.01 for each segment). The upper anterior segment showed significantly reduced inward excursion distance and FAC in the TOF group than in the control group (p <0.01, both). The dyskinetic outward excursion distances of the middle and lower posterior segments were significantly lower in the TOF group than in the control group (p <0.01, both). In the upper and middle anterior segments, the endocardial outward excursion distances were significantly higher in the TOF group than in the control group (p <0.01 and 0.05). Correlation between right ventriculographic and color kinesis measurements was excellent (y = 1.14x - 1.30, r = 0.87 for the endocardial inward excursion, and y = 1.03x +/- 0.56, r = 0.91 for the FAC). In conclusion, color kinesis is a useful method for assessing regional right ventricular wall motion. Segmental analysis of color kinesis images provides accurate, automated, and quantitative diagnosis of regional right ventricular wall motion abnormalities in patients with surgically repaired TOF.

Child, Preschool↗

Use of color kinesis for evaluation of left ventricular filling in patients with dilated cardiomyopathy and mitral regurgitation.

OBJECTIVES: We tested the feasibility of using analysis of color kinesis images to objectively assess global and regional left ventricular (LV) diastolic function in patients with dilated cardiomyopathy (DCM). In addition, the ability of this technique to track drug-induced changes on LV diastolic properties was studied. BACKGROUND: Diastolic dysfunction contributes to symptomatology in patients with DCM. The assessment of LV diastolic function using conventional Doppler echocardiography is indirect and is confounded by multiple variables. Moreover, the noninvasive evaluation of regional diastolic properties is difficult. In contrast, color kinesis directly tracks and color-encodes regional diastolic endocardial motion. METHODS: We studied 24 patients with DCM and mitral regurgitation (MR) and 24 age-matched normal subjects. Transmitral and pulmonary vein flow velocities were measured using pulsed Doppler echocardiography. Diastolic color kinesis images were used to calculate indexes of magnitude and timing of global and regional diastolic function. Diastolic asynchrony was evaluated in different subgroups of patients with DCM. The effects of drug infusions (nitroprusside and dobutamine) were also studied. RESULTS: Color kinesis indexes of global diastolic function showed significant differences between patients with DCM and normal subjects. Compared with Doppler indexes, color kinesis was less confounded by MR and was capable of differentiating between drug-induced lusitropic and vasodilator effects. Diastolic asynchrony was increased in patients with DCM and severe MR. CONCLUSIONS: Quantitative analysis of global and regional LV diastolic function in patients with DCM using color kinesis is feasible.

Adult↗

Cranial kinesis in geckoes: functional implications.

Although it is generally assumed that cranial kinesis is a plesiomorphic characteristic in squamates, experimental data tend to contradict this hypothesis. In particular, coupled kinesis (i.e. streptostyly and mesokinesis) presumably arose independently in only a limited number of highly specialised groups. In this study, we investigated cranial kinesis in one of the most specialised of these groups: geckoes. On the basis of cineradiographic and electromyographic data, the fast opening and the slow closing/power stroke phases were modelled to elucidate possible functions of the observed kinesis. The results of these analyses show that the retraction of the muzzle unit during crushing is a self-reinforcing system that increases bite force and reduces the joint forces; the active protraction of the kinetic system during jaw opening, in contrast, enhances opening speed through the coupling of the intracranial units. It can be argued that cranial kinesis in geckoes is probably not an adaptive trait as such but, instead, a consequence of the 'Bauplan' of the cranial system in these animals. Presumably as a result of constructional constraints on the size of the jaw musculature and eyes, the supratemporal and postorbital bars were lost, which resulted in enormous mobility in the skull. To counteract the potential negative factors associated with this (decrease in bite force, skull damage), the kinetic system may have become coupled, and thus functional.

Adaptation, Physiological↗

Assessment of left ventricular wall motion abnormalities with the use of color kinesis: a valuable visual and training aid.

Accurate interpretation of left ventricular segmental wall motion by echocardiography is an important yet difficult skill to learn. Color-coded left ventricular wall motion (color kinesis) is a tool that potentially could aid in the interpretation and provide semiquantification. We studied the usefulness of color kinesis in 42 patients with a history of congestive cardiomyopathy who underwent two-dimensional echocardiograms and a color kinesis study. The expert's reading of the two-dimensional wall motion served as a reference for comparison of color kinesis studies interpreted by the expert and a cardiovascular trainee. Correlation between two-dimensional echocardiography and the expert's and trainee's color coded wall motion scores were r = 0.83 and r = 0.67, respectively. Reproducibility between reviewers and between operators was also assessed. Interobserver variability for color-coded wall motion showed a correlation of r = 0.78. Correlation between operators was also good; r = 0.84. Color kinesis is reliable and appears promising as an adjunct in the assessment of wall motion abnormalities by echocardiography. It is both a valuable visual aid, as well as a training aid for the cardiovascular trainee.

Adult↗

Validity of acoustic quantification colour kinesis for detection of left ventricular regional wall motion abnormalities: a transoesophageal echocardiographic study.

Transoesophageal echocardiography is a sensitive monitor for intraoperative myocardial ischaemia. Colour kinesis is a new technology for echocardiographic assessment of regional wall motion based on acoustic quantification. We have examined the feasibility and accuracy of quantitative segmental analysis of colour kinesis images to provide objective evaluation of systolic regional wall motion during the perioperative period using transoesophageal echocardiography (TOE). Two-dimensional echocardiograms were obtained in the transgastric short-axis and long-axis views in 60 patients with coronary artery disease undergoing noncardiac surgery. End-systolic colour overlays superimposed on the grey scale images were obtained with colour kinesis to colour encode left ventricular endocardial motion throughout systole. These colour-encoded images were divided into segments and compared with corresponding conventional two-dimensional images. Six hundred of a potential 720 left ventricular wall segments were of sufficient resolution for grading by experts; they diagnosed wall motion abnormalities in 61 of these segments by a conventional method. In comparing the conventional TOE method with colour kinesis, there were 60 true positives, 482 true negatives, 57 false positives and 1 false negative result. This yielded a sensitivity of 98%, specificity of 89%, positive predictive value of 51% and negative predictive value of 100%. Translational and rotational movement of the heart and papillary muscle interference were common problems accounting for false positive diagnoses. We conclude that colour kinesis provides a basis for objective and on-line evaluation of left ventricular regional wall motion which is a sensitive but non-specific method. It may be a useful aid for the less experienced because it can potentially direct the anaesthetist's attention towards specific segments.

Adult↗

Color Kinesis: Principles of Operation and Technical Guidelines.

Color kinesis is a new echocardiographic technique that aids in the assessment of global and regional left ventricular performance during either systole or diastole. Color kinesis uses automated border detection technology based on backscatter data to display both the magnitude and timing of endocardial motion in real time. The color kinesis display superimposes a color overlay on the two-dimensional echocardiographic image; the number of color pixels represents the magnitude of endocardial motion, while the different colors represent the timing of endocardial motion according to a predefined color scheme. Because color kinesis is an operator-dependent technique, the steps involved in performing a technically adequate study will be reviewed as well as the pitfalls and technical limitations. The potential clinical applications of color kinesis will also be discussed.

Journal Article↗

Echocardiographic quantification of regional left ventricular wall motion with color kinesis.

BACKGROUND: Color kinesis is a new technology for the echocardiographic assessment of left ventricular wall motion based on acoustic quantification. This technique automatically detects endocardial motion in real time by using integrated backscatter data to identify pixel transitions from blood to tissue during systole on a frame-by-frame basis. In this study, we evaluated the feasibility and accuracy of quantitative segmental analysis of color kinesis images to provide objective evaluation of regional systolic endocardial motion. METHODS AND RESULTS: Two-dimensional echocardiograms were obtained in the short-axis and apical four-chamber views in 20 normal subjects and 40 patients with regional wall motion abnormalities. End-systolic color overlays superimposed on the gray scale images were obtained with color kinesis to color encode left ventricular endocardial motion throughout systole on a frame-by-frame basis. These color-encoded images were divided into segments by use of custom software. In each segment, pixels of different colors were counted and displayed as stacked histograms reflecting the magnitude and timing of regional endocardial excursion. In normal subjects, histograms were found to be highly consistent and reproducible. The patterns of contraction obtained in normal subjects were used as a reference for the objective automated interpretation of regional wall motion abnormalities, defined as deviations from this pattern. The variability in the echocardiographic interpretation of wall motion between two experienced readers was similar to the diagnostic variability between the consensus of the two readers and the automated interpretation. CONCLUSIONS: Color kinesis is a promising new tool that may be used clinically to improve the qualitative and quantitative evaluation of spatial and temporal aspects of global and regional wall motion. In this initial study, segmental analysis of color kinesis images provided accurate, automated, and quantitative diagnosis of regional wall motion abnormalities.

Adult↗

Quantitative evaluation of global and regional left ventricular diastolic function with color kinesis.

BACKGROUND: Diastolic wall motion asynchrony is a major determinant of impaired left ventricular (LV) filling in patients with concentric hypertrophy and coronary artery disease. We evaluated the ability of Color Kinesis, a new echocardiographic technique that color-encodes endocardial motion, to quantitatively assess global and regional LV filling properties. METHODS AND RESULTS: Color Kinesis images and mitral and pulmonary vein flow Doppler data were acquired in 29 patients with LV hypertrophy and 29 age-matched control subjects. In addition, Color Kinesis data were correlated to coronary angiographic findings in 15 patients with suspected coronary artery disease. Segmental analysis of Color Kinesis images was used to obtain time histograms of regional diastolic fractional area change, wherein early and late peaks (peaks 1 and 2) reflected rapid LV filling and atrial contraction, respectively. Regional mean LV filling time and filling curves were used to objectively identify diastolic endocardial motion asynchrony in patients with LV hypertrophy and coronary artery disease. None of the mitral and pulmonary vein Doppler indices differentiated patients with normalized mitral Doppler profile (n=13) from control subjects, whereas reduced peak1/peak2 ratio and prolonged mean filling time indicated augmented contribution of atrial contraction toward LV filling (P<.05). In 22 of 25 patients with LV hypertrophy and preserved systolic function and in all patients with coronary artery disease, delayed diastolic endocardial motion was observed in at least one segment. CONCLUSIONS: Analysis of Color Kinesis images provides objective assessment of global and regional LV filling properties and allows identification of both diastolic dysfunction in patients with normalized Doppler indices and wall motion asynchrony.

Adult↗

The role of cranial kinesis in birds.

In birds, the ability to move the upper beak relative to the braincase has been the subject of many functional morphological investigations, but in many instances the adaptive significance of cranial kinesis remains unclear. Alternatively, cranial kinesis may be considered a consequence of the general design of the skull, rather than an adaptive trait as such. The present study reviews some results related to the mechanism and functional significance of cranial kinesis in birds. Quantitative three-dimensional X-ray has shown that in skulls morphologically as divers as paleognaths and neognaths the mechanism for elevation of the upper beak is very similar. One of the mechanisms proposed for avian jaw movement is a mechanical coupling of the upper and the lower jaw movement by the postorbital ligament. Such a mechanical coupling would necessitate upper beak elevation. However, independent control of upper and lower jaw has been shown to occur during beak movements in birds. Moreover, kinematic modeling and force measurements suggests that the maximum extensibility of collagen, in combination with the short distance of the insertion of the postorbital ligament to the quadrato-mandibular articulation do not constitute a block to lower jaw depression. The lower jaw ligaments serve to limit the maximal extension of the mandibula. It is suggested here that cranial kinesis in avian feeding may have evolved as a consequence of an increase in eye size. This increase in size led to a reduction of bony bars in the lateral aspect of the skull enabling the transfer of quadrate movement to the upper jaw. The selective forces favoring the development of a kinetic upper beak in birds may be subtle and act in different ecological contexts. Simultaneous movement of the upper and lower jaw not only increases the velocity of beak movements, but with elevated upper beak also less force is required to open the lower jaw. However, the penalty of increased mobility of elements in a lightweight skull and a large eye is potential instability of skull elements during biting, smaller bite forces and limitations on joint reaction forces. Such a lightly built, kinetic skull may have evolved in animals that feed on small plant material or insects. This type of food does not require the resistance of large external forces on the jaws as in carnivores eating large prey.

Animals↗

Cranial kinesis in gekkonid lizards

Cranial kinesis was studied in two species of gekkonid lizard, Gekko gecko and Phelsuma madagascariensis, using cineradiography and electromyography. The skull of these geckoes showed the three types of kinesis described by Versluys at the beginning of this century: streptostyly, mesokinesis and metakinesis. In accordance with the later model of Frazzetta, the skull of these animals can be modelled by a quadratic crank system: when the mouth opens during feeding, the quadrate rotates forward, the palato-maxillary unit is lifted and the occipital unit swings forward. During jaw closing, the inverse movements are observed; during crushing, the system is retracted beyond its resting position. The data gathered here indicate that the coupled kinesis (streptostyly + mesokinesis) is most prominently present during the capture and crushing cycles of feeding and is largely absent during late intraoral transport, swallowing, drinking and breathing. The electromyographic data indicate a consistent pattern of muscular activation, with the jaw opener and pterygoid protractor always active during the fast opening phase, and the jaw closers active during closing and crushing. Our data generally support the model of Frazzetta. Although the data gathered here do not allow speculation on the functional significance of the kinesis, they clearly provide some key elements required for a further investigation of the functional and adaptive basis of the system.

Journal Article↗

Analysis of right ventricular kinesis by means of transesophageal echocardiography: present problems and perspectives.

The evaluation of right ventricular (RV) kinesis by two-dimensional echocardiography represents a difficult task. Transthoracic echocardiography can visualize the RV in several projections, but the image quality and the variability of imaging views usually do not allow quantitative analysis. We investigated the potential of transesophageal echocardiography (TEE) for evaluating RV global function and regional kinesis, in 32 controls and in 16 patients with inferior myocardial infarction (MI) and asynergy involving the inferior wall of both ventricles. Good-quality images of at least one horizontal section of the RV were obtained in 73% of subjects by conventional, 90 degrees sector and in 100% of subjects by wide-angle, "panoramic" sector. Images of the RV in short-axis view at medium level were acquired and evaluated in 93% of cases, but at basal and apical levels only in 67% and 39%, respectively. The low percentage of successful detection and evaluation of the RV at apical level can be explained by prominent motion and trabeculation of the apex. Global systolic area changes (SAC) in controls attained similar values at apical and medium levels (60% and 59%, respectively), but were significantly lower (48%, P less than 0.05) at basal level. In patients with previous inferior MI and inferoposterior asynergy, global SAC were significantly (P less than 0.01) lower at medium and basal levels (32% and 27%, respectively) compared with controls. Regional kinesis of RV was assessed as segmental SAC in 12 different segments, by fixed and float system of center of cavity.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Cranial kinesis in the amphibia: a review.

All extant orders of amphibians are characterized by kinetic skulls. Main type of intracranial movability in amphibians is pleurokinetism, that is supplemented in different amphibian groups by various types of rhyncho- and prokinetism. The most primitive pattern of cranial kinesis is revealed in the stegocrotaphic gymnophions. More paedomorphic species retain general cranial flexibility that is characteristic of larval skull. That is unfavourable for evolution of well-regulated (adult) cranial kinesis and related feeding adaptations. Kinetism is also reduced in the species with heavily ossified skulls. Adaptive role and evolution of cranial kinesis in amphibians are discussed.

Amphibians↗

Molecular phylogenetics of emydine turtles: taxonomic revision and the evolution of shell kinesis.

The 10 extant species of emydine turtles represent an array of morphological and ecological forms recognizable and popular among scientists and hobbyists. Nevertheless, the phylogenetic affinities of most emydines remain contentious. Here, we examine the evolutionary relationships of emydine turtles using 2092 bp of DNA encoding the mitochondrial genes cyt b, ND4, and adjacent tRNAs. These data contain 339 parsimony informative characters that we use to erect hypotheses of relationships for the Emydinae. Both maximum parsimony and maximum likelihood methods yield a monophyletic Emydinae in which all but three nodes are well resolved. Emys orbicularis, Emydoidea blandingii, and Clemmys marmorata form a monophyletic clade, as do the species of Terrapene. Clemmys muhlenbergii and Clemmys insculpta form a third monophyletic group that may be sister to all other emydines. Clemmys guttata is problematic and probably related to Terrapene. Based on this phylogeny, and previous molecular work on the group, we suggest the following taxonomic revisions: (1) Clemmys should be restricted to a single species, C. guttata. (2) Calemys should be resurrected for C. muhlenbergii and C. insculpta. (3) Emys should be expanded to include three species: E. orbicularis, E. blandingii, and E. marmorata. Furthermore, our analyses show that neither kinetic-shelled nor akinetic-shelled emydines form monophyletic groups. Therefore, shell kinesis was either independently gained in Emys and Terrapene or secondarily lost in E. marmorata and C. guttata. Parsimony, paleontological evidence, and the multiple origins of shell kinesis in related turtle lineages (especially geoemydines) support the independent origin of plastral kinesis.

Animals↗

Effects of inotropic stimulation on segmental left ventricular relaxation quantified by color kinesis.

Although myocardial ischemia impairs left ventricular (LV) relaxation before contractile function, regional LV diastolic dysfunction is difficult to evaluate by conventional echocardiography. Because beta-adrenergic stimulation enhances myocardial relaxation, we sought to characterize segmental LV diastolic function (by color kinesis) during dobutamine stress echocardiography and compare it with independently assessed segmental systolic function. We studied 22 patients with suspected coronary artery disease with color kinesis by acquiring digital images with endocardial motion display throughout diastole. Quantification of LV segmental diastolic peak filling rate (SPFR, normalized to segmental end-diastolic area/s) was obtained at rest, low-dose, and peak dobutamine infusion in myocardial segments visualized from the short-axis and/or apical 4-chamber views. In patients with resting normal LV systolic function and a dobutamine-induced hypercontractile response (group I, n = 13 patients; 102 segments), progressive increases in SPFR (p <0.001) were seen in all segments. However, in LV segments with resting systolic wall motion abnormalities (group II, n = 9 patients; 74 segments) SPFR measured at rest was significantly lower than that in group I (p <0.005) and did not increase significantly in response to dobutamine. In both groups of patients, LV myocardial segments (n = 528; rest and after dobutamine)-systolic and quantitative diastolic function-were concordant in 84% and 77% as viewed from short-axis and apical views, respectively. Thus, segmental LV diastolic function can be measured with color kinesis at rest and after inotropic stimulation, allowing comparison with segmental systolic function during pharmacologic stress testing.

Aged↗

Echocardiographic quantification of regional left ventricular wall motion with color kinesis.

Echocardiographic assessment of regional systolic left ventricular function is usually performed qualitatively and depends on investigator experience. In this study, we investigated a new method for quantifying regional systolic wall motion based on color kinesis. In this study, regional systolic wall motion velocity (Vsys) was determined by dividing end-systolic color width by systolic time. High regional wall motion velocity (Vhigh) was determined by dividing the width of the widest color by its duration of 40 ms. First, in vitro measurements with an acrylic glass model were obtained; these demonstrated a high correlation between echocardiographically determined and real "wall motion velocities" (R = 0.99, p<0.001, R2 = 0.99). Then, 17 healthy, young persons were examined, and normal values for each left ventricular wall segment (16-segment model) were determined. The mean Vsys and Vhigh of all 272 wall segments were 2.3+/-0.6 and 7.4+/-1.8 cm/s, respectively. Finally, in 12 patients with coronary artery disease and prior myocardial infarction, Vsys and Vhigh of each left ventricular wall segment were determined and compared with conventional echocardiographic wall motion analysis using the usual 4-grade score system. Analysis of data showed that quantitative color kinesis measurements demonstrated significantly lower velocity values in pathologic than in normal wall segments (Mann-Whitney U test, p<0.05). Measurements discriminated between pathologic and normal wall motion, with an accuracy of 89% for Vsys and 83% for Vhigh (chi-square test, p<0.05). To summarize, in this first study, measurements of regional wall motion velocities with color kinesis demonstrated reliable results for the quantification of regional left ventricular systolic function.

Aged↗