Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Ion Mobility Spectrometry”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Coronaspray nebulization and ionization of liquid samples for ion mobility spectrometry.

Ion mobility spectrometry after electrospray nebulization and ionization was investigated as a method for the detection of components dissolved in liquids. While electrosprary operating conditions proved promising, greater sensitivity was achieved when the electric potential applied to the sample introduction needle was increased above breakdown potential and a corona discharge was established. Passing the liquid through the corona discharge established a "coronaspray" that efficiently nebulized and ionized the solvent and analytes. In this initial investigation of coronaspray ion mobility spectrometry (CIMS), ion current as a function of potential, temperature, and liquid flow rate was studied; several IMS spectra were obtained; and a continuous monitoring mode of operation was demonstrated. The results from this study indicated that CIMS has potential as a versatile and sensitive detection method for a variety of analytical procedures involving liquid flowing streams such as flow injection analysis, liquid chromatography, capillary zone electrophoresis, and field flow fractionation.

Electrochemistry↗

Screening of solid commercial pharmaceuticals using ion mobility spectrometry.

Ion mobility spectrometry (IMS) was used to analyze vapors generated directly above pharmaceutical solids warmed in air to 100-200 degrees C. Vapors were characterized by IMS/mass spectrometry to evaluate the air-based atmospheric pressure chemical ionization of components in analgesic medicines. A hand-held IMS was used to determine the suitability of membrane-based instrumentation for routine analyses of large polar molecules. Mobility spectra for seven compounds could be individually represented by single or a few intense product ion peaks. Ion source fragmentations were nonexistent with these pharmaceuticals but complex behavior in the IMS involving ion-molecule clustering was pronounced in certain spectra. Mobility spectra were distinct and recognizable for each compound and binary mixtures of individual ingredients and actual over-the-counter medicines produced mobility spectra suggestive of composite spectra. This work represents a first delineation of complex ion mobility spectra for mixtures using spectra from individual components. These findings support further development of IMS for use in quality control during manufacture of such preparations and in routine screening of powders containing analgesic pharmaceuticals.

Acetaminophen↗

Orthogonal extraction ion mobility spectrometry.

Ion Mobility Spectrometry is a powerful tool for the study of molecular conformations, separation of mass isomers, and analysis of complex mixtures and suppression of chemical background. The factors that limit the capabilities of the technique include its relatively low resolving power and duty cycle. New principle of gas-phase ion separation, based on ion focusing under the influence of electrostatic field and stationary in time gas flow, is proposed. Both analytical calculations and a numerical simulation show that a diffusion-limited resolution of several hundred can be achieved. The new type of ion mobility analyzer is called orthogonal extraction IMS. The proposed ortho-IMS can be interfaced with commercial mass spectrometers and offers the theoretical resolution of several hundred and ion transmission close to 100%.

Journal Article↗

Process analysis using ion mobility spectrometry.

Ion mobility spectrometry, originally used to detect chemical warfare agents, explosives and illegal drugs, is now frequently applied in the field of process analytics. The method combines both high sensitivity (detection limits down to the ng to pg per liter and ppb(v)/ppt(v) ranges) and relatively low technical expenditure with a high-speed data acquisition. In this paper, the working principles of IMS are summarized with respect to the advantages and disadvantages of the technique. Different ionization techniques, sample introduction methods and preseparation methods are considered. Proven applications of different types of ion mobility spectrometer (IMS) used at ISAS will be discussed in detail: monitoring of gas insulated substations, contamination in water, odoration of natural gas, human breath composition and metabolites of bacteria. The example applications discussed relate to purity (gas insulated substations), ecology (contamination of water resources), plants and person safety (odoration of natural gas), food quality control (molds and bacteria) and human health (breath analysis).

Bacteria↗

Ion mobility spectrometry and ion mobility spectrometry/mass spectrometric characterization of dimenhydrinate.

Positive and negative ion mobility spectra of dimenhydrinate are presented, and the calculated reduced mobility (K0) values for the most significant peaks are reported. Mass identification of the ionic species associated with the peaks in the ion mobility spectra was achieved by interfacing the ion mobility spectrometer to a mass spectrometer. The application of ion mobility spectrometry to the detection of dimenhydrinate and other drug residues on the hands of patients admitted to hospital with drug overdose is also discussed.

Dimenhydrinate↗

Electrospray ionization ion mobility spectrometry of carboxylate anions: ion mobilities and a mass-mobility correlation.

A number of carboxylate anions spanning a mass range of 87-253 amu (pyruvate, oxalate, malonate, maleate, succinate, malate, tartarate, glutarate, adipate, phthalate, citrate, gluconate, 1,2,4-benzenetricarboxylate, and 1,2,4,5-benzenetetracarboxylate) were investigated using electrospray ionization ion mobility spectrometry. Measured ion mobilities demonstrated a high correlation between mass and mobility in both N2 and CO2 drift gases. Such a strong mass-mobility correlation among structurally dissimilar ions suggests that the carboxylate functional group that these ions have in common is the source of the correlation. Computational analysis was performed to determine the most stable conformation of the studied carboxylate anions in the gas phase under the current experimental conditions. This analysis indicated that the most stable conformations for multicarboxylate anions included intramolecular hydrogen-bonded ring structures formed between the carboxylate group and the neutral carboxyl group. The carboxylate anions that form ring confirmations generally show higher ion mobility values than those that form extended conformations. This is the first observation of intramolecular hydrogen-bonded ring conformation of carboxylate anions in the gas phase at atmospheric pressure.

Anions↗

Solid phase microextraction with matrix assisted laser desorption/ionization introduction to mass spectrometry and ion mobility spectrometry.

Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.

Enkephalins↗

Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry.

Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

Atmospheric Pressure↗

Field asymmetric waveform ion mobility spectrometry studies of proteins: Dipole alignment in ion mobility spectrometry?

Approaches to separation and characterization of ions based on their mobilities in gases date back to the 1960s. Conventional ion mobility spectrometry (IMS) measures the absolute mobility, and field asymmetric waveform IMS (FAIMS) exploits the difference between mobilities at high and low electric fields. However, in all previous IMS and FAIMS experiments ions experienced an essentially free rotation; thus the separation was based on the orientationally averaged cross-sections Omega(avg) between ions and buffer gas molecules. Virtually all large ions are permanent electric dipoles that will be oriented by a sufficiently strong electric field. Under typical FAIMS conditions this will occur for dipole moments >400 D, found for many macroions including most proteins above approximately 30 kDa. Mobilities of aligned dipoles depend on directional cross-sections Omega(dir) (rather than Omega(avg)), which should have a major effect on FAIMS separation parameters. Here we report the FAIMS behavior of electrospray-ionization-generated ions for 10 proteins up to approximately 70 kDa. Those above 29 kDa exhibit a strong increase of mobility at high field, which is consistent with predicted ion dipole alignment. This effect expands the useful FAIMS separation power by an order of magnitude, allowing separation of up to approximately 10(2) distinct protein conformers and potentially revealing information about Omega(dir) and ion dipole moment that is of utility for structural characterization. Possible approaches to extending dipole alignment to smaller ions are discussed.

Electrochemistry↗

Characterization of benzodiazepine drugs by ion mobility spectrometry.

Chemical ionization ion mobility spectrometry (CI-IMS) was used to characterize a number of benzodiazepines. In almost every example studied, the positive ion mobility spectrum consisted of a single ion peak corresponding to [M]+ or [MH]+. With some compounds, e.g., oxazepam, lorazepam, and chlordiazepoxide, fragment ions were noted that serve as good markers for the identification of these chemicals. Reduced mobility constants (K0) for the most significant peaks were calculated, and all ions produced were mass-analyzed by injection into a quadrupole mass spectrometer. The results of this study point to the potential of IMS as a qualitative tool for the rapid detection (analysis time less than 10 s) and reliable identification of benzodiazepines. Preliminary results on the application of digital signal processing and a second-derivative algorithm to partially overlapping IMS peaks are presented, and potential improvements are discussed.

Anti-Anxiety Agents↗

The analysis of methamphetamine hydrochloride by thermal desorption ion mobility spectrometry and SIMPLISMA.

Ion mobility spectrometry (IMS) has been successfully developed to yield an advanced portable instrument. Such instruments may detect trace quantities of regulated substances at the crime scene. The atmospheric ion chemistry that occurs within the instrument may hinder the determination of analytes in real-world samples. The use of temperature programming adds an extra dimension to the data that improves the selectivity of the IMS data when chemometric processing is applied. The SIMPLISMA (SIMPLe-to-use-Interactive Self-Modeling Mixture Analysis) method is demonstrated for modeling variances in IMS data that are introduced from the temperature program. Methamphetamine hydrochloride IMS peaks are obscured by chemical interferences that arise from cigarette smoke residue. Cigarette smoke residue is pervasive at crime scenes. The ability of SIMPLISMA to resolve the analyte peaks that correspond to methamphetamine hydrochloride from interfering cigarette smoke has been demonstrated. A reduced mobility of 1.62 cm2V-1s-1 was observed for a methamphetamine hydrochloride monomer. With the IMS drift tube at room temperature, a second peak was observed at 1.24 cm2V-1s-1, which is consistent with a dimer ion. This peak has not been previously reported.

Central Nervous System Stimulants↗

[Detection of trace organic compounds by using ion mobility spectrometry and SIMPLISMA].

Ion mobility spectrometry (IMS) is a sensitive means for detection of trace volatile organic compounds. This technique has been used as a routine method for some organic compounds in forensic science, environmental and pharmaceutical analysis, etc. SIMPLISMA (simple-to-use-interactive self-modeling mixture analysis) is an effective method for large-scale data processing. In the present work, SIMPLISMA has been applied to process IMS data of three methanephosphonate esters. The SIMPLISMA can retain the peak characteristics and eliminate much of the noises of the IMS measurements. The processed spectral data can be subsequently used for other computations, such as curve resolution and pattern recognition etc.

Chemistry Techniques, Analytical↗

Separation of cisplatin and its hydrolysis products using electrospray ionization high-field asymmetric waveform ion mobility spectrometry coupled with ion trap mass spectrometry.

Cisplatin and its mono- and dihydrated complexes have been separated using a high-field asymmetric waveform ion mobility spectrometry (FAIMS) analyzer interfaced with electrospray ionization (ESI) and ion trap mass spectrometry (ITMS). The addition of helium to the nitrogen curtain/carrier gas in the FAIMS device improved both the sensitivity and selectivity of the electrospray analysis. Introduction of a three-component mixture as curtain/carrier gas, nitrogen, helium, and carbon dioxide, resulted in further improvements to sensitivity. Compared with conventional ESI-MS, the background chemical noise in the ESI-FAIMS-ITMS spectrum was dramatically reduced, resulting in over 30-fold improvement in the signal-to-noise ratio for cisplatin. Analytical results were linear over the concentration range 10-200 ng/mL for intact cisplatin with a corresponding detection limit determined of 0.7 ng/mL with no derivatization or chromatographic separation prior to analysis.

Journal Article↗

Probing shapes of bichromophoric metal-organic complexes using ion mobility mass spectrometry.

Ion mobility mass spectrometry (IM-MS) was used to probe the structures of several metal complexes carrying pendant chromophores. The three complexes investigated were the copper(II) complex Cu(DAC)2+ (DAC = 1,8-bis(9-methylanthracyl)cyclam, cyclam = 1,4,8,11-tetraazacyclotetradecane), the N-nitrosylated ligand DAC-NO, and the Roussin's red salt ester (mu-S,mu-S')-protoporphyrin-IX-bis(2-thioethyl ester)tetranitrosyldiiron (PPIX-RSE). From the IM-MS data coupled with theoretical calculations, it was found that [Cu(II)(DAC - H)]+ exists as a single conformer, with one anthracenyl group above the cyclam and the other below, similar to the crystal structure of Cu(II)(DAC)2+. The metal-free N-nitrosylated ligand (DAC-NO + H)+ has two conformations: one family of structures has one anthracenyl group above the cyclam and one below, while the other has both anthracenyl groups on the same side of the cyclam. These observations are consistent with 1H NMR data for the neutral DAC-NO complex that indicate the presence of two geometric isomers in solution. The third species, PPIX-RSE, has a porphyrin chromophore covalently linked to an Fe2S2(NO)4 cluster for use as a precursor for the photochemical delivery of nitric oxide in single- and two-photon excitation processes. Ion mobility indicates the presence of two (PPIX-RSE + H)+ conformations, consistent with the previous interpretation of the bimodal fluorescence lifetime decay seen for PPIX-RSE. DFT structures, in good agreement with the IM-MS cross sections, indicate two "bent" conformations with the planes of the porphyrin and Fe2S2 rings at different angles with respect to each other.

Journal Article↗

Enhanced mixture analysis of poly(ethylene glycol) using high-field asymmetric waveform ion mobility spectrometry combined with fourier transform ion cyclotron resonance mass spectrometry.

The combination of high-field asymmetric waveform ion mobility spectrometry (FAIMS) with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) makes possible lower detection limits, increased sensitivity, and increased dynamic range in the analysis of poly(ethylene glycol) (PEG) samples of low molecular weight. The signal gain obtained using FAIMS depends on ion identity, with a range between 1.8x and 14x obtained for various molecular ions of PEG 600. A 1.7-fold reduction in noise is obtained using FAIMS due to the elimination of chemical noise. The improved detection performance is predominantly due to a reduction in adverse Coulomb effects as a result of ions being selectively introduced into the mass spectrometer. The high ion transmission obtained using FAIMS combined with the high sensitivity of FTICR-MS detection make possible separation of multiple gas-phase conformers of PEG molecular cations that have low abundance (less than 0.2% relative abundance) and that have not been detected previously. Mixed dications of PEG that have the same nominal mass but differ by the number polymer subunits (m/Delta m up to 25,000) can be separately introduced into the mass spectrometer using FAIMS. Interactions of the carrier gas with the metal ions that are attached to the PEG molecules appear to be the most significant factor in these FAIMS separations.

Cations↗

Ion mobility spectrometry for food quality and safety.

Ion mobility spectrometry is known to be a fast and sensitive technique for the detection of trace substances, and it is increasingly in demand not only for protection against explosives and chemical warfare agents, but also for new applications in medical diagnosis or process control. Generally, a gas phase sample is ionized by help of ultraviolet light, ss-radiation or partial discharges. The ions move in a weak electrical field towards a detector. During their drift they collide with a drift gas flowing in the opposite direction and, therefore, are slowed down depending on their size, shape and charge. As a result, different ions reach the detector at different drift times, which are characteristic for the ions considered. The number of ions reaching the detector are a measure of the concentration of the analyte. The method enables the identification and quantification of analytes with high sensitivity (ng l(-1) range). The selectivity can even be increased - as necessary for the analyses of complex mixtures - using pre-separation techniques such as gas chromatography or multi-capillary columns. No pre-concentration of the sample is necessary. Those characteristics of the method are preserved even in air with up to a 100% relative humidity rate. The suitability of the method for application in the field of food quality and safety - including storage, process and quality control as well as the characterization of food stuffs - was investigated in recent years for a number of representative examples, which are summarized in the following, including new studies as well: (1) the detection of metabolites from bacteria for the identification and control of their growth; (2) process control in food production - beer fermentation being an example; (3) the detection of the metabolites of mould for process control during cheese production, for quality control of raw materials or for the control of storage conditions; (4) the quality control of packaging materials during the production of polymeric materials; and (5) the characterization of products - wine being an example. The challenges of such applications were operation in humid air, fast on-line analyses of complex mixtures, high sensitivity - detection limits have to be, for example, in the range of the odour limits - and, in some cases, the necessity of mobile instrumentation. It can be shown that ion mobility spectrometry is optimally capable of fulfilling those challenges for many applications.

Cheese↗

Hadamard transform ion mobility spectrometry.

Traditionally, the spectrum acquired using ion mobility spectrometry (IMS) is an average of multiple experimental cycles. Each cycle is initiated by passing a short burst of ions into a drift tube containing a homogeneous electric field. Prior to starting the subsequent cycle, all ions in the system must arrive at the detector or spectral overlap may occur. To maximize resolution, the ion pulse admitted to the drift tube is small in relation to the total scan time with the unfortunate consequence of an inherently low duty cycle (approximately 1%). Offering an improved SNR through a 50% duty cycle, the Hadamard transform (HT) applied to ion mobility spectrometry represents a fresh alternative to signal-averaged data acquisition. Initial results from measurements of amphetamine and cytochrome c samples indicate a 2-10-fold increase in SNR for the HT-IMS technique with no reduction in resolution.

Journal Article↗

Developments in ion mobility spectrometry-mass spectrometry.

Ion mobility spectrometry (IMS) has been used for over 30 years as a sensitive detector of organic compounds. The following is a brief review of IMS and its principles with an emphasis on its usage when coupled to mass spectrometry. Since its inception, IMS has been interfaced with quadrupole, time-of-flight, and Fourier-transform ion cyclotron resonance mass spectrometry. These hybrid instruments have been employed for the analysis of a variety of target analytes, including biomolecules, explosives, chemical warfare degradation products, and illicit drugs.

Journal Article↗