Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Finite Element Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

The effect of ventilation tubes on stresses and vibration motion in the tympanic membrane: a finite element analysis.

Finite element analysis is used to determine the mechanical behaviour of structures. The deformation of a structure caused by a force can be calculated, and the stresses and strains within the component can be found. In brief, a geometric representation-a 'drawing'-of the structure is loaded into a computer, and a component is divided into 'elements' which usually have the shape of 'bricks'. A common analogy is a 'lego' brick assembly. The deformation of an element can be determined using engineering formulae, and the deformation of the whole structure can be determined when the elements are re-asssembled. There have been very few analyses of the biomechanical behaviour of ventilation tubes, or grommets, even though clinical studies have indicated that tube design and material determines extrusion rates and may influence tympanosclerosis. This paper reports a comprehensive biomechanical analysis of the effect of a grommet on the tympanic membrane. Analytical and computer simulation techniques (finite element analysis) are used to determine the changes in the vibratory motion and stresses in the membrane when a Reuter-Bobbin ventilation tube is inserted. It is found that the presence of a ventilation tube significantly affects the motion of the membrane in the neighbourhood of the implant. When the effect of implant material is investigated, it is found that the amplitude of motion of a heavier metal implant is less than a lighter polymeric implant. If it is true that higher motion predisposes towards early extrusion, then the lighter implant (polyethylene) is predicted to have a higher extrusion rate. Regarding the maximum stresses in the tympanic membrane, they form a crescent-shaped region in the anterior and posterior quadrants in the regions where tympoansclerosis is observed. The magnitude and pattern of the stress is predicted not to depend significantly on the presence of the tube. This suggests that tympanosclerosis is not determined by the implant per se and therefore that no tube design feature can be expected to prevent it.

Computer Simulation↗

Statistical methods in finite element analysis.

Finite element analysis (FEA) is a commonly used tool within many areas of engineering and can provide useful information in structural analysis of mechanical systems. However, most analyses within the field of biomechanics usually take no account either of the wide variation in material properties and geometry that may occur in natural tissues or manufacturing imperfections in synthetic materials. This paper discusses two different methods of incorporating uncertainty in FE models. The first, Taguchi's robust parameter design, uses orthogonal matrices to determine how to vary the parameters in a series of FE models, and provides information on the sensitivity of a model to input parameters. The second, probabilistic analysis, enables the distribution of a response variable to be determined from the distributions of the input variables. The methods are demonstrated using a simple example of an FE model of a beam that is assigned material properties and geometry over a range similar to an orthopaedic fixation plate. In addition to showing how each method may be used on its own, we also show how computational effort may be minimised by first identifying the most important input variables before determining the effects of imprecision.

Cervical Vertebrae↗

Technical note: creating a four-dimensional model of the liver using finite element analysis.

Finite element analysis and two liver CT scans were used to construct a four-dimensional (4D) model of the liver during breathing. A linear elastic, small deformation mechanical model was applied to one patient to obtain intermediate organ position and shape between exhale and inhale. Known transformations between anatomically defined subsections of the exhale and inhale liver surfaces were applied as constraints to the exhale CT liver model. Intermediate states were then calculated and time weighted to determine a 4D model of the liver as it deforms during the breathing cycle. This model can be used to calculate a more accurate dose distribution during radiotherapy.

Algorithms↗

Evaluation of design parameters of osseointegrated dental implants using finite element analysis.

Finite element analyses were performed for various shapes of dental implant to study effects on stress distribution generated in the surrounding jaw bone and to determine an optimal thread shape for even stress distribution. It was found that the square thread shape filleted with a small radius was more effective on stress distribution than other dental implants used in the analyses. Additional analyses were performed on the implant with the thread shape obtained from previous analyses for varying other design parameters, such as the width of thread end and height of thread for various load directions, to determine the optimal dimensions of the implant. Stress distribution was more effective in the case when the width of thread end and the height of thread were 0.5p and 0.46p, respectively, where p is the screw pitch. Then, using the optimal implant thread dimensions determined previously, stress analyses were performed with various screw pitches and implant lengths, to investigate effects on stress distribution and to find the way to reduce the maximum effective stress generated in the jaw bone. Results show that the maximum effective stress decreased not only as screw pitch decreased gradually but also as implant length increased.

Alveolar Process↗

Determination of ankle external fixation stiffness by expedited interactive finite element analysis.

Interactive finite element analysis holds the potential to quickly and accurately determine the mechanical stiffness of alternative external fixator frame configurations. Using as an example Ilizarov distraction of the ankle, a finite element model and graphical user interface were developed that provided rapid, construct-specific information on fixation rigidity. After input of specific construct variables, the finite element software determined the resulting tibial displacement for a given configuration in typically 15s. The formulation was employed to investigate constructs used to treat end-stage arthritis, both in a parametric series and for five specific clinical distraction cases. Parametric testing of 15 individual variables revealed that tibial half-pins were much more effective than transfixion wires in limiting axial tibial displacement. Factors most strongly contributing to stiffening the construct included placing the tibia closer to the fixator rings, and mounting the pins to the rings at the nearest circumferential location to the bone. Benchtop mechanical validation results differed inappreciably from the finite element computations.

Ankle↗

The HUKM Spinal Instrumentation System for adolescent idiopathic scoliosis. A biomechanical comparison study using finite element analysis.

This finite element analysis is aimed at comparing relative stiffness of three different posterior instrumentation constructs: the Hospital Universiti Kebangsaan Malaysia Spinal Instrumentation System (HUKM-SIS), the Cotrell-Dubousset Instrumentation (CDI) and Harrington Instrumentation System (HIS), used in the treatment of adolescent idiopathic scoliosis (AIS). The constructs were tested under various loads using MSC Patran 2001 r2a. Under increasing flexion loads, there was a linearly corresponding increase in deflection magnitudes for all constructs on the load-deflection curve. The CDI was the stiffest construct under axial, forward flexion and extension loads, followed by the HUKM-SIS and HIS. Under lateral bending loads, the HUKM-SIS construct was the stiffest followed by CDI and HIS. The HUKM-SIS construct was stiffer than HIS under torsional loads. We conclude that multiple pedicle screws increase the stiffness of posterior instrumentation constructs under all loads and inter-segmental spinous processes wiring increase the stiffness against lateral bending.

Adolescent↗

Stress variations in recast Ni-Cr alloy--a finite element analysis.

A finite element analysis was carried out to analyse the stress variations in a mandibular posterior fixed partial denture (FPD), made of recast nickel-chromium alloy. A two dimensional finite element model was developed and then analysed with STAAD III/ISDS program with an occlusal load of 1 kg applied to the casting surface. The analysis revealed that the connectors experienced maximum stresses and the generated stress values decreased within the fixed partial denture made of recast Ni-Cr alloy. It seemed unlikely that FPD inspite of being made of recast alloy might fail before the other tissue components show signs of degeneration thus establishing the potential for recycling the Ni-Cr alloy in actual dental practice.

Bite Force↗

Effects of friction on the unconfined compressive response of articular cartilage: a finite element analysis.

A finite element analysis is used to study a previously unresolved issue of the effects of platen-specimen friction on the response of the unconfined compression test; effects of platen permeability are also determined. The finite element formulation is based on the linear KLM biphasic model for articular cartilage and other hydrated soft tissues. A Galerkin weighted residual method is applied to both the solid phase and the fluid phase, and the continuity equation for the intrinsically incompressible binary mixture is introduced via a penalty method. The solid phase displacements and fluid phase velocities are interpolated for each element in terms of unknown nodal values, producing a system of first order differential equations which are solved using a standard numerical finite difference technique. An axisymmetric element of quadrilateral cross-section is developed and applied to the mechanical test problem of a cylindrical specimen of soft tissue in unconfined compression. These studies show that interfacial friction plays a major role in the unconfined compression response of articular cartilage specimens with small thickness to diameter ratios.

Biomechanical Phenomena↗

Comparison of plate-screw systems used in mandibular fracture reduction: finite element analysis.

A finite element model of the human dentate mandible has been developed to provide a comparison of fixation systems used currently for fracture reduction. Volume domains for cortical bone, cancellous bone, and teeth were created and meshed in ANSYS 8.0 based on IGES curves created from computerized tomography data. A unilateral molar clench was loaded on the model with a fracture gap simulated along the symphysis. Results based on Von Mises stress in cortical and cancellous bone surrounding the screws, and on fracture surface spatial fixation, show some relative differences between different screw-plate systems, yet all were judged to be appropriate in their reduction potential.

Adult↗

Stress-related molar responses to the transpalatal arch: a finite element analysis.

The finite element method of analysis (FEM) was used to analyze theoretically the effects of a transpalatal arch (TPA) on periodontal stresses of molars that were subjected to typical retraction forces. The purposes of this investigation were (1) to construct an appropriate finite element model, (2) to subject the model to orthodontic forces and determine resultant stress patterns and displacements with and without the presence of a TPA, and (3) to note any differences in stress patterns and displacements between models with and without a TPA. Because anchorage is stress-dependent, a TPA must be able to modify periodontal stresses as a prerequisite for increasing orthodontic anchorage. A finite element model, consisting of two maxillary first molars, their associated periodontal ligaments and alveolar bone segments, and a TPA, was constructed. The model was subjected to simulated orthodontic forces (2 N per molar) with and without the presence of the TPA. Resultant stress patterns at the root surface, periodontal ligament, and alveolar bone, as well as displacements with and without a TPA, were calculated. Analysis of the results revealed minute differences of less than 1% of the stress range in stress values with respect to the presence of a TPA. Modification of bone properties to allow for increased displacement levels confirmed the ability of the TPA to control molar rotations; however, no effect on tipping was noted. Results suggested that the presence of a TPA has no effect on molar tipping, decreases molar rotations, and affects periodontal stress magnitudes by less than 1%. The final results suggest an inability of the TPA to modify orthodontic anchorage through modification of periodontal stresses.

Alveolar Process↗

Thermo-debonding mechanisms in dentin bonding systems using finite element analysis.

The finite element method (FEM) has been extensively used in evaluating the interfacial status of biomaterials. We used FEM to explore the microscopic debonding mechanism of the dentin/hybrid layer/resin adhesive interface. The stress status of the local material was used as an index to judge whether the adhesive interface would develop a debonding mechanism. To generate the local stress concentration, the thermal boundary condition was applied to the model which has the phenomenon of the coefficient of thermal expansion (CTE) mismatch. The thermal boundary condition was used to emulute a previous study conducted with a laser thermoacoustic technique (LTAT). The materials, Scotchbond MP, Optibond, and Tenure bonding systems, used in the previous experiment were also tested in this study. The results show that interfacial debonding in the finite element model occurred through the hybrid layer for both the Scotchbond MP and Tenure systems, as well as within the adhesive layer itself for the Optibond system. These findings are compatible with observations by SEM obtained by LTAT. Another transformed model was created to test the "elastic cavity wall" concept. The result also confirms the importance of the elastic cavity wall concept. These compatible results between FEM and LTAT indicate that FEM can be a very useful supplement to thermoacoustic testing.

Biocompatible Materials↗

Application of laminates to mouthguards: finite element analysis.

A finite element model comprising a flat-ended indentor and a disc representing a colliding object and mouthguard materials, respectively, has been developed to study stress distribution and impact force in laminates. The disc consists of two layers and its top layer is in contact with the indentor. Two different combinations of layers were employed for the simulation. One had a soft layer placed on top of the rigid layer and the other was vice versa. It was found that the former had no significant difference from a monolayer in stress distribution and impact force. However, the latter was found to have a significant effect on stress distribution, and this effect could be increased by controlling ratios of modulus and volume fractions of the top and bottom layers. It was also found that the magnitude of the impact force increases with increasing effect of stress distribution, but this competition can be reduced to some degree by decreasing the volume fraction ratio of top to bottom layers.

Journal Article↗

Slatted floors and solid floors: stress and strain on the bovine hoof capsule analyzed in finite element analysis.

An established finite element model of a bovine claw was used to compare mechanical stress levels in a loaded model claw on different types of flooring. The following situations were compared: a claw standing on a solid floor, a claw standing on the edge of a short tie stand, and claws standing on slatted floors with slats of 28 and 40 mm (wide) running parallel and perpendicular to the claw axis. Finite element analysis allowed visualization of stress peaks seen predominantly in the weight-bearing border of the dorsal abaxial wall and of the bulbar region and in the proximal axial wall. Maximum stress values of 13 MPa were found in the model claw loaded on the solid floor and values of 18 to 22 MPa were seen in the model claw loaded on the edge of the solid floor. On slatted floors, stresses increased in the situation in which the claw was not supported under the abaxial wall. Comparison between the other slatted floors showed little difference in amounts of mechanical stress. A clear distinction was detected between the solid floor with full claw contact and the slatted floors. From the point of view of the mechanical stress seen in finite element analysis, a large contact area between claw and floor, as seen in the solid surface floor, is preferable. When use of slatted floors is unavoidable, direction of the slats should run perpendicular to the direction of the walkway to prevent even more mechanical impact in certain footing situations.

Animals↗

Measurement of ventricular volume from blood conductance using two-dimensional finite element analysis.

We used finite element analysis to study the relationship between the intraventricular blood conductance and the right ventricular volume. Previous studies reported a quasi-linear dependence between these two quantities. We quantified the effects of the resistivities of the surrounding tissues (e.g. heart wall, lungs) on this relationship and performed simulations for four different right ventricular longitudinal sectional areas to assess the linearity of the relationship. The relationship was most significantly affected by the blood conductivity. However, the effects of the cardiac muscle and the lungs could not be neglected. The dependence of the intraventricular blood conductance on the ventricular volume was found to be non-linear. Although to some extent inaccurate, a linear approximation of this relationship is useful for the development of rate-responsive implantable cardiac pacemakers, where the pacing rate is adjusted based on the need for cardiac output. The cardiac output is computed from the product of the heart rate and the stroke volume. The stroke volume can be estimated by measuring the changes in the intraventricular blood conductance. The electrodes needed for the stroke volume estimation can be placed on the same catheter as those used for pacing. The use of this method for clinical monitoring or diagnosis has to be investigated further given that its errors in the estimation of the stroke volume are considerably larger than those corresponding to standard methods such as dye- or thermo-dilution.

Blood Physiological Phenomena↗

Effect of a thin HA coating on the stress/strain distribution in bone around dental implants using three-dimensional finite element analysis.

Three-dimensional finite element analysis was performed for thin hydroxyapatite (HA) coated and titanium dental implants to study the effects on stress/strain distribution in the mandible with application of axial and oblique loads. The implants were of screw and cylinder types. With an axial load, the maximum equivalent bone stresses in the titanium implants were 21.5 and 29.0 MPa for the cylinder and screw types respectively, and the stress and strain distributions differed. For the cylinder type, the highest stress was located at the implant base, and for the screw type, it was located at the top edge of the first thread within the cortical bone. For the HA-coated cylinder and screw implants, the maximum equivalent bone stresses were 7.1 and 7.2 MPa respectively. The stress and strain distributions were similar, and the highest stress was located on the upper side of the cortical bone around the implant neck for both implants. Of the implants examined, the screw type HA-coated implant had the most uniform stress distribution in bone.

Anisotropy↗

The effect of preparation height and taper on cement lute stress: a three-dimensional finite element analysis.

Three dimensional finite element models of an upper second premolar and molar with full veneer gold crown preparations were developed from extracted samples. The cement lute width was kept constant at 40 microm, but the height and preparation taper were varied. For both models the preparation height was either 1.5 mm (short preparation) or 3 mm (long preparation). The preparation taper was either 10 degree or 30 degree, giving a total of eight models. Each model was loaded with a 10 N horizontal load, a 10 N vertical load or a 10 N load distributed across the occlusal surface. The maximum shear stress and the maximum Von Mises' stress in the cement lute of each model were recorded. For the premolar, the maximum shear stresses ranged from 0.3-5.43 MPa and the maximum Von Mises' stress ranged from 1.44-14.98 MPa. For the molar, the maximum shear stresses ranged from 0.15-5.22 MPa and the maximum Von Mises' stress ranged from 0.3 7-15.02 MPa. The stress fields were consistently higher in the premolar with a 30 degree preparation taper compared to the 10 degree taper. The attainment of a cavity taper of 100 is still important to minimise stress in the cement lute and is particularly important in teeth with a lower preparation surface area such as a premolar

Bicuspid↗

Finite element analysis in spine research.

Finite element analysis is a widely accepted tool used in many industries and research activities. It allows new designs to be thoroughly 'tested' before a prototype is even manufactured, components and systems which cannot readily be experimented upon to be examined, and 'diagnostic' investigations to be undertaken. Finite element models are already making an important contribution to our understanding of the spine and its components. Models are being used to reveal the biomechanical function of the spine and its behaviour when healthy, diseased or damaged. They are also providing support in the design and application of spinal instrumentation. The spine is a very complex structure, and many of the models are simplified and idealized because of the complexity and uncertainty in the geometry, material properties and boundary conditions of these problems. This type of modelling simplification is not peculiar to spinal modelling problems. Indeed, the idealization is often a strength when there is such uncertainty and variation between one individual and another, allowing cause-effect relationships to be isolated and fully explored, and the inherent variability of experimental tests to be eliminated. This paper reviews the development of finite element analysis in spinal modelling. It shows how modelling provides a wealth of information on our physiological performance, reduces our dependence on animal and cadaveric experiments and is an invaluable complement to clinical studies. It also leads to the conclusion that, as computing power and software capabilities increase, it is quite conceivable that in the future it will be possible to generate patient-specific models that could be used for patient assessment and even pre- and inter-operative planning.

Biomechanical Phenomena↗