Sensitivity of linear CCD array based film scanners used for film dosimetry.

Film dosimetry is commonly performed by using linear CCD array transmission optical densitometers. However, these devices suffer from a variation in response along the detector array. If not properly corrected for, this nonuniformity may lead to significant overestimations of the measured dose as one approaches regions close to the edges of the scanning region. In this note, we present measurements of the spatial response of an AGFA Arcus II document scanner used for radiochromic film dosimetry. Results and methods presented in this work can be generalized to other CCD based transmission scanners used for film dosimetry employing either radiochromic or radiographic films.

Computer Peripherals↗

High precision film dosimetry with GAFCHROMIC films for quality assurance especially when using small fields.

Treatment units for radiosurgery, brachytherapy, implementation of seeds, and IMRT generate small high dose regions together with steep dose gradients of up to 30%-50% per mm. Such devices are used to treat small complex-shaped lesions, often located close to critical structures, by superimposing several single high dose regions. In order to test and verify these treatment techniques, to perform quality assurance tasks and to simulate treatment conditions as well as to collect input data for treatment planning, a GAFCHROMIC film based dosimetry system for measuring two-dimensional (2-D) and three-dimensional (3-D) dose distributions was developed. The nearly tissue-equivalent radiochromic GAFCHROMIC film was used to measure dose distributions. A drum scanner was investigated and modified. The spectral emission of the light source and the filters together with the efficiency of the CCD filters for the red color were matched and balanced with the absorption spectra of the film. Models based on refined studies have been developed to characterize theoretically the physics of film exposure and to calibrate the film. Mathematical descriptions are given to calculate optical densities from spectral data. The effect of darkening has been investigated and is described with a mathematical model. The influence of the scan temperature has been observed and described. In order to cope with the problem of individual film inhomogeneities, a double irradiation technique is introduced and implemented that yields dose accuracies as good as 2%-3%. Special software routines have been implemented for evaluating and handling the film data.

Absorptiometry, Photon↗

A new method of readout in radiochromic film dosimetry.

Radiochromic film as a dosimetry medium offers several advantages in high-resolution radiography. A new technique of readout was developed to measure the optical density distributions of the film in purely directed light. This technique implements radiochromic film dosimetry near the film's absorption maximum by using a single-mode top-surface emitting laser diode (675.2 nm). The effective sensitivity of the film, compared with a helium-neon laser densitometer (632.8 nm), is increased approximately threefold. Good accuracy, high spatial resolution and simple assembly of the readout system is achieved. Beam profiles of the four final collimator helmets of a Leksell Gamma Knife (Elekta Inc., Sweden) were experimentally determined. Measured profiles and full-widths at half maximum are consistent with the computer generated data of the dose planning system (Kula 4.4, Elekta Inc., Sweden). The output factor of the 4 mm collimator (the smallest collimator with the steepest dose gradient), essential for the application of well defined doses, was checked. The measurements established an output factor of 826 +/- 9 that lies 9 +/- 1% lower than the adjusted one.

Calibration↗

Directional dependence in film dosimetry: radiographic and radiochromic film.

The trend towards conformal, intensity modulated radiotherapy treatments has established the need for a true integrating dosimeter. In traditional radiotherapy, radiographic film dosimetry is commonly used. The accuracy and reproducibility of film optical density as an indicator of dose is influenced by several variables, including the chemical processing conditions. As a result radiochromic film, with all the advantages of radiographic film but without the need for chemical processing, has increased in popularity, although the low-dose sensitivity of radiochromic film does remain a disadvantage for some experiments. Several studies have investigated the reproducibility of radiochromic film results, but none have specifically addressed the well-known directional dependence seen with traditional radiographic film. In this study, the directional dependence of radiographic (Kodak X-omat V) and radiochromic (Gafchromic) films were measured. It was found that both films over responded when exposed parallel to the central axis of the beam as opposed to perpendicular exposure. An attempt is made to explain the reason for the responses of both films in terms of spectral effects and the air gap between the phantom segments. Although radiographic film exposed parallel rather than perpendicular to the central axis of the beam exhibits a measured difference in film response at depth, this over response does not occur when the extent of the film is restricted to a small region at the centre of the phantom (in this case an air gap is not introduced across the phantom). This suggests that it is the air gap rather than the orientation of the film that is the cause of the over response. Furthermore, when film occupies a slice through the entire phantom an over response occurs for both radiographic and radiochromic film, indicating that spectral effects are not the cause.

Film Dosimetry↗

Film dosimetry of clinical electron beams.

Film dosimetry is used widely to obtain relative dose distributions of clinical electron beams in phantoms. Nevertheless, measurement results obtained with film dosimetry may lack precision and reliability. In this paper well defined and reproducible methods in film dosimetry are discussed. By application of these methods, film dosimetry appears to be adequate in measuring relative dose distributions of clinically applied electron beams, with an accuracy of 1% to 2% of the dose maximum, in water and plastics as well as in heterogeneously composed material.

Electrons↗

Scanning orientation effects on Gafchromic EBT film dosimetry.

Gafchromic EBT film, a new high sensitivity radiochromic film has been tested for variations in optical properties due to scanning orientation. Gafchromic EBT film has been shown to produce a scanning orientation effect whereby variations in measured relative optical density are found due to the films orientation relative to the scanner direction. This relative optical density change was found to be relatively consistent for different films exposed to varying dose levels ranging from 0 Gy to 3 Gy. A maximum variation of 0.0157 +/- 0.0035 in optical density (OD) was found. This relates to an approximate 15% variation in net OD for a 50 cGy irradiated film and 4% variation for a 3 Gy irradiated film. No noticeable effects or variations were seen with changing scanning resolution or with the film placed "up or down" during scanning. Other Gafchromic film types were tested and compared to EBT for unirradiated film to assess the magnitude of this orientation effect on the scanner used and results showed that EBT produced a significantly higher effect that MD-55-2, HS, XR type T and XR type R film by up to 3 times. As such, providing the same orientation of EBT film when scanning for dosimetric analysis becomes an essential part of EBT film dosimetry.

Anisotropy↗

Physical mechanism of the Schwarzschild effect in film dosimetry--theoretical model and comparison with experiments.

In consideration of the importance of film dosimetry for the dosimetric verification of IMRT treatment plans, the Schwarzschild effect or failure of the reciprocity law, i.e. the reduction of the net optical density under 'protraction' or 'fractionation' conditions at constant dose, has been experimentally studied for Kodak XOMAT-V (Martens et al 2002 Phys. Med. Biol. 47 2221-34) and EDR 2 dosimetry films (Djouguela et al 2005 Phys. Med. Biol. 50 N317-N321). It is known that this effect results from the competition between two solid-state physics reactions involved in the latent-image formation of the AgBr crystals, the aggregation of two Ag atoms freshly formed from Ag(+) ions near radiation-induced occupied electron traps and the spontaneous decomposition of the Ag atoms. In this paper, we are developing a mathematical model of this mechanism which shows that the interplay of the mean lifetime tau of the Ag atoms with the time pattern of the irradiation determines the magnitude of the observed effects of the temporal dose distribution on the net optical density. By comparing this theory with our previous protraction experiments and recent fractionation experiments in which the duration of the pause between fractions was varied, a value of the time constant tau of roughly 10 s at room temperature has been determined for EDR 2. The numerical magnitude of the Schwarzschild effect in dosimetry films under the conditions generally met in radiotherapy amounts to only a few per cent of the net optical density (net OD), so that it can frequently be neglected from the viewpoint of clinical applications. But knowledge of the solid-state physical mechanism and a description in terms of a mathematical model involving a typical time constant of about 10 s are now available to estimate the magnitude of the effect should the necessity arise, i.e. in cases of large fluctuations of the temporal pattern of film exposure.

Bromides↗

Comparison of three high-resolution digitizers for radiochromic film dosimetry.

A recently introduced radiographic film scanner from Howtek is evaluated and compared to two other commercially available densitometry systems for its use in radiochromic (RC) film dosimetry in the clinical dose range 0-100 Gy. It has a high-intensity red LED light-source centered at 662 nm (near the major absorption peak for RC film), and is coupled to a CCD linear array detector. This new densitometry system is directly compared to two high-resolution film scanners commonly employed in RC film dosimetry, namely the Lumiscan 75 digitizer (He-Ne laser light source) and the Vidar VXR-16 digitizer (fluorescent light source). A spot densitometer (Nuclear Associates Radiochromic Densitometer) with a filtered 671 nm laser-diode light source is also included as a reference for comparison. The response of the spot densitometer and three high-resolution digitizers is characterized by the dose required to reach a net optical density of 1 (DNOD1), and is 16.0, 37.3, and 46.4 Gy for the Nuclear Associates Radiochromic Densitometer, Howtek MultiRAD 460 and Lumiscan 75 digitizer, respectively. The Vidar VXR-16 does not reach a net optical density of 1. The minimum usable dose at which a 2% level of uncertainty can be achieved (MUD2%) on the three digitizers are 2.6, 6.0, and 38.5 Gy for the Howtek MultiRAD 460, Lumiscan 75, and Vidar VXR-16, respectively. The Howtek MultiRAD 460 shows the greatest sensitivity, lowest MUD2% and best signal-to-noise ratio in the clinical dose range 0-100 Gy. Furthermore, it has no apparent interference (moiré) artifacts that severely limit the low optical density region of the He-Ne laser digitizer. For high-resolution radiochromic dosimetry in the clinical dose range 0-100 Gy, the high-intensity red LED light-source digitizer proves to be the superior modality.

Artifacts↗

[Radiation loading problems in petrous bone tomography. Experimental research using film dosimetry on the Alderson phantom].

Using film dosimetry and an Alderson skull phantom, the iso-dose distribution during tomography of the petrous bone was investigated. We were particularly concerned with the radiation dose to the lens of the eye, the critical organ in the skull, and to the inner ear, using different types of examination and various positions of the skull. The choice of suitable film material and standardisation against TLD measurements is crucial for the accuracy of film dosimetry, allowing for correction of film blackening in relation to varying energies. Tomography of the petrous bone in the prone position produced a reduction in radiation dose to the eye to only 1 to 4% of the dose incident on the occiput. In this way, and using high definition screen and grinds, it is possible to obtain optimal tomographic images despite drastic reduction of the scattered radiation to the eye. Radiation dose to the inner ear is greatly below any significant somatic does, irrespective of projection or technique. Special measures to reduce radiation to the inner ear are neither effective nor sensible.

Film Dosimetry↗

Precautions and strategies in using a commercial flatbed scanner for radiochromic film dosimetry.

The purpose of this study was to investigate the value of a commercially available flatbed scanner for film dosimetry with radiochromic film for external radiotherapy. The EPSON Pro 1680 Expression scanner was examined as a densitometer for two-dimensional film dosimetry with Gafchromic EBT film. An accurate and efficient scanning procedure was established. Possible drift and warm-up effects of the scanner were studied and the direct physical influence of the scanner light on the radiochromic film was assessed. Next, we investigated the scan field uniformity. Also, we examined if the accuracy of radiochromic film was improved by subtracting the optical density of the unirradiated blank film from the optical density of the irradiated film. To assess the accuracy of Gafchromic EBT film when the EPSON scanner was used as a densitometer, the depth dose of a 2 x 15 cm(2) field and the in-plane and cross-plane profiles of a 15 x 15 cm(2) field were measured and compared with diamond detector measurements. When taking consecutive scans, we found that the optical density taken from the first scan was about 1% higher than the optical density taken from subsequent scans. We attribute this to the warming up of the lamp of the scanner. Longer-term drift of the scanner was found to be absent. We found that the use of a correction matrix was necessary to correct for the non-uniform scanner response over the scan field. Subtracting the optical density of the unirradiated blank film from the irradiated film improves the precision of the Gafchromic EBT film. Depth dose and profile measurements with Gafchromic EBT film and the diamond detector are in agreement within 2.5%. The EPSON Pro 1680 Expression scanner is an excellent tool for accurate two-dimensional film dosimetry with Gafchromic EBT film provided that some precautions and corrections are taken into account.

Calibration↗

External audit of photon beams by mailed film dosimetry: feasibility study.

A feasibility study for mailed film dosimetry has been performed. The global reproducibility of the method is better than 2%. It is shown that the normalized sensitometric curve does not depend on photon beam quality in the range from Co-60 gamma-rays to 18 MV x-rays, although the dose per optical density decreases when the energy increases. The fading of the latent image before film processing is only 3% per month and the normalized sensitometric curve is not modified after a period of 51 days between irradiation and processing. Sets of films were mailed to three different institutes for irradiation and returned for processing and evaluation after more than two months in order to verify that mailing of irradiated and unprocessed films does not produce unwanted artefacts. Finally the feasibility of external audits with mailed film dosimetry is illustrated by comparison of beam profiles measured with films and ionization chambers in a polystyrene phantom.

Cobalt Radioisotopes↗

Measuring skin dose with radiochromic dosimetry film in the cardiac catheterization laboratory.

A new radiochromic dosimetry film was tested to determine its potential for patient skin dose monitoring in a fluoroscopically intensive environment such as the cardiac catheterization laboratory. The dose, time, energy, dose fractionation, dose rate, and sheet to sheet uniformity response were tested. All tests support the conclusion that this is a simple, noninvasive, retrospective method to identify skin regions at risk from high x-ray doses. The consistency and accuracy of dose measurements allow for an estimation of the localized skin dose to those patients who are susceptible to radiation induced skin injury.

Cardiac Catheterization↗

Contribution of Cerenkov radiation in high-energy x-ray and electron beam film dosimetry using water-substitute phantoms.

The contribution of Cerenkov radiation in high-energy film dosimetry was investigated using commercially available water-substitute phantoms. Doses were evaluated using six phantoms: RMI-451, Mix-DP, WE-211, WE-Black, PMMA and PMMA-Black. The contribution of Cerenkov radiation was determined from the shielded and unshielded evaluation doses when a bare film was inserted into the phantom in a dark room and irradiated. For both x-ray and electron beams, Cerenkov radiation produced a phantom-dependent increase in the unshielded dose when compared with the shielded dose. We also found that the darker the phantom, the smaller the contribution of Cerenkov radiation. These results suggest that for film dosimetry using bare film, the accuracy of dose evaluation may be improved by using phantoms with high opacity.

Artifacts↗

Film dosimetry for radiotherapy treatment planning verification of a 6 MV tangential breast irradiation.

Film dosimetry has been applied to measure relative dose distributions in an anthropomorphic polystyrene breast phantom having cork lungs, simulating a radiation therapy treatment with 6 MV opposing tangential beams. Measured relative dose distributions showed good reproducibility (about 1.5%, 1 SD) and good agreement (< 2%) with calculations performed with a three-dimensional treatment planning system. These results demonstrate that film dosimetry is a useful tool for treatment planning verification.

Breast Neoplasms↗