Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Environmental matrix”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Determination of polycyclic aromatic hydrocarbons with molecular weight 300 and 302 in environmental-matrix standard reference materials by gas chromatography/mass spectrometry.

An analytical approach based on gas chromatography/ mass spectrometry (GC/MS) is presented for the measurement of polycyclic aromatic hydrocarbons with molecular weight (MW) 300 and 302 in environmental samples. Three different GC stationary phases [5% and 50% phenyl methylpolysiloxane and dimethyl (50% liquid crystalline) polysiloxane] were compared, and retention indexes (RI) are given for 23 individual MW 302 isomers. Identification of MW 300 and 302 isomers in four environmental-matrix Standard Reference Materials (SRMs) (SRM 1597, coal tar extract; SRM 1648 and SRM 1649a, air particulate matter; and SRM 1941, marine sediment) was based on the comparison of RI data and mass spectra from authentic standards. Dibenzo[a,l]pyrene, which is of considerable interest because of its high carcinogenicity, was identified and quantified in the four environmental-matrix SRMs. A total of 23 isomers of MW 302 and four isomers of MW 300 were quantified in four different environmental-matrix SRMs, and the results are compared to previously reported results based on liquid chromatography with fluorescence detection.

Environmental Pollutants↗

Matrix effect-free analytical methods for determination of perfluorinated carboxylic acids in environmental matrixes.

Perfluorocarboxylic acids (PFCAs) are persistent chemicals that have been found widely in the environment. Their accurate determination in environmental matrixes, particularly soil, sediment, and sludge, at low levels presents significant analytical challenges. The commercialization of electrospray interfaces for liquid chromatography-mass spectrometric analysis facilitated analysis of PFCAs at low levels, but issues with quantitative analysis due to matrix suppression or enhancement still persist. The methods described in this study utilize simple and rapid sample purification procedures to remove matrix components sufficiently so that errors due to coeluting matrix peaks are negligible and recoveries of PFCAs are consistently and reproducibly quantitative. Extracts from solid samples (soil and sediment) and liquid bacterial sludge are purified using dispersive solid-phase extraction. Recovery values generally are in the 70-120% range, with limits of quantitation of 1 ppb. The method utilizes an extraction solvent previously shown to release and recover aged residues of PFCAs. A confirmatory method using two precursor to product ions is also provided and demonstrated.

Calibration↗

Determination of methylmercury in environmental matrixes by on-line flow injection and atomic fluorescence spectrometry.

The precision and bias of monomethylmercury (MMHg) determinations in environmental samples can be improved by directly coupling and automating the numerous steps involved with analysis of this toxic Hg species. We developed a simple and robust mercury speciation analyzer (MSA) for measurement of MMHg in environmental matrixes. This on-line hyphenated system couples the main analytical steps, including sample introduction, aqueous-phase ethylation, Tenax preconcentration, and gas chromatographic separation, to cold vapor atomic fluorescence detection and data acquisition. Here we describe the MMHg-MSA, present results of laboratory optimization and performance tests, and compare the reproducibility between dual analytical channels. With alternating sample concentration and analysis, a dual-channel system permits six high-accuracy MMHg determinations per hour. Additional advantages compared to the traditional manual method include ease of operation and high precision (<5% relative standard deviation). The MSA is applicable to the determination of MMHg in various environmental matrixes, and it can be fully automated. This method was validated by analysis of MMHg in certified reference materials of sediment and biological tissue. Estimated detection limits for MMHg with the MSA are approximately 0.01 ng g(-1) for a 0.1-g sample of dry sediment or fish and approximately 0.01 ng L(-1) for 0.15 L of water.

Journal Article↗

Determination of Cr3+, CrO42-, and Cr2O72- in environmental matrixes by high-performance liquid chromatography with diode-array detection (HPLC-DAD).

A high-performance liquid chromatographic method with diode array detection (HPLC-DAD), based on chelation with ammonium pyrrolidinedithiocarbamate (APDC), has been developed for the determination of chromium species. Determination of Cr3+, CrO42-, and Cr2O72- was performed for standards and synthetic environmental matrixes. This method is robust, rugged, and can be used for rapid routine determination of chromium species with high precision and reliability. Sample pretreatment is simple. The method is capable of discriminating not only between Cr(III) and Cr(VI) but also between the chemical forms of Cr(VI) - CrO42- and Cr2O72-. By analysis of numerous samples the method has been shown to be selective, sensitive, and free from matrix interference, which is crucial for the determination of chromium species in difficult-to-analyze environmental matrixes. This method has been validated by means of an interlaboratory study. Although different speciation techniques were used during this study, there was good agreement between results from the two laboratories. The method detection limits were 7 and 4 mg L(-1) for Cr3+ and Cr2O72-, respectively. Recoveries of the analytes from spiked samples were 98% and 100% for Cr3+ and Cr2O72-, respectively. Both were based on a 10-mL sample volume spiked with 0.4 mg L(-1) chromium.

Chromates↗

Speciation of iodide, iodine, and iodate in environmental matrixes by inductively coupled plasma atomic emission spectrometry using in situ chemical manipulation.

Dissolved iodine, iodide, and iodate are determined in environmental matrixes by in situ chemical manipulation and inductively coupled plasma atomic emission spectrometry (ICPAES). The method uses equipment commonly available to most laboratories involved in environmental inorganic analysis. Total dissolved iodine, iodide, and iodate are determined by ICPAES using iodine vapor generation. Total iodine is determined directly by ICPAES after filtration. Total dissolved iodide (I-) is oxidized in situ to iodine by the addition of sodium nitrite in sulfuric acid in a simplified continuous flow manifold. Iodate is determined by prereduction at the instrument before analysis by the in situ oxidation ICPAES procedure. A standard nebulizer produces the gas-liquid separation of the total iodine, which is then quantified by ICPAES at 206.16 nm. The instrument detection limit for the iodine analysis was 0.04 microgram/mL. Recoveries from seawater, saltwater, and freshwater standard reference materials ranged from 85 to 118% and averaged 98%. For samples containing both iodine and iodide, the total is determined with in situ oxidation, iodine is determined without the oxidizing reagents, and iodine is calculated from the difference. For samples containing all 3 species, pre-reduction is used and the iodine and iodide concentrations are subtracted for quantitation of iodate. The analysis is selective for these 3 species (I-, I2, and IO3). A group of 20-30 samples may be analyzed and quantitated for all 3 individual, commonly occurring iodide species in less than 1 h. The procedure is considerably faster than any other reported techniques. This method is especially well-suited to the analysis of small environmental samples.

Environmental Monitoring↗

Measurement of voltammetric peak area and resolution of overlapping peaks in the simultaneous determination of copper, lead, cadmium, and nickel in environmental matrixes.

Peak area was used for the simultaneous determination of copper(II), lead(II), cadmium(II), and nickel(II) in environmental matrixes by differential pulse voltammetry. The voltammetric measurements were performed with a conventional 3-electrode cell and an ammonia-ammonium chloride buffer, pH 9.1, as the supporting electrolyte. The analytical procedure was verified first in aqueous reference solutions and later by analysis of the standard reference materials Estuarine Sediment BCR-CRM 277 and River Sediment BCR-CRM 320. The precision and accuracy of the method, expressed as the relative standard deviation and the relative error, respectively, were <5% in all cases; the detection limit for each element under the experimental conditions used was in the range 1-5 microg/L. In the case of mutual interference between neighboring elements, an analytical procedure is proposed that is based on the standard additions technique, which allows the resolution of the overlapping voltammetric peaks.

Ammonium Chloride↗

Heavy metals monitoring at a Mediterranean natural ecosystem of Central Italy. Trends in different environmental matrixes.

The study deals with the evaluation of the impact of heavy metal pollution on a Mediterranean natural ecosystem, and presents the results derived from a monitoring of heavy metals in different environmental matrixes (atmospheric dry depositions, suspended particulate matter (SPM) and stemflow of forest trees). Two sites in Castelporziano Presidential Estate (Rome), one internal and one near the sea-side, were chosen in order to assess the differences in pollutant load. Results showed that heavy metal contamination can arise from local anthropogenic activities, in particular road traffic, and long-range pollution, from industrial and artisan activities near Rome.

Air Pollutants↗

Determination of platinum and rhodium in environmental matrixes by solid sampling-electrothermal vaporization-inductively coupled plasma mass spectrometry.

Electrothermal vaporization from a graphite furnace was used in combination with inductively coupled plasma mass spectrometry (ICPMS) for the determination of Pt and Rh in environmental matrixes. Solid samples of tunnel dust, grass, and atmospheric aerosol collected on a cellulose filter could be analyzed directly, such that sample dissolution-which is not self-evident for the determination of platinum group metals-could be avoided. By heating the graphite furnace according to a multistep temperature program, spectral interferences were avoided, since a "dry" plasma was obtained, while "parent" ions such as Cu, Zn, and Pb, giving origin to interfering molecular ions, were vaporized during the thermal pretreatment step. For tunnel dust, the most demanding sample matrix, a mixture of HCl and HF was used as a modifier to stimulate the vaporization of matrix components during the thermal pretreatment step and, hence, to alleviate matrix-induced analyte signal suppression during the actual vaporization step. Calibration was accomplished by means of single standard addition with an aqueous standard solution. The results obtained agreed within the experimental uncertainty with the corresponding reference values (certified values or results obtained using pneumatic nebulization ICPMS), while relative standard deviations of < or = 15% were typical for both Pt and Rh. In all samples, a Pt/Rh ratio of approximately 6-8 was established. For a typical sample mass of 2 mg, limits of detection were 0.35 ng/g for Pt and 0.05 ng/g for Rh.

Calibration↗

Evaluation of "shotgun" proteomics for identification of biological threat agents in complex environmental matrixes: experimental simulations.

There is currently a great need for rapid detection and positive identification of biological threat agents, as well as microbial species in general, directly from complex environmental samples. This need is most urgent in the area of homeland security, but also extends into medical, environmental, and agricultural sciences. Mass-spectrometry-based analysis is one of the leading technologies in the field with a diversity of different methodologies for biothreat detection. Over the past few years, "shotgun"proteomics has become one method of choice for the rapid analysis of complex protein mixtures by mass spectrometry. Recently, it was demonstrated that this methodology is capable of distinguishing a target species against a large database of background species from a single-component sample or dual-component mixtures with relatively the same concentration. Here, we examine the potential of shotgun proteomics to analyze a target species in a background of four contaminant species. We tested the capability of a common commercial mass-spectrometry-based shotgun proteomics platform for the detection of the target species (Escherichia coli) at four different concentrations and four different time points of analysis. We also tested the effect of database size on positive identification of the four microbes used in this study by testing a small (13-species) database and a large (261-species) database. The results clearly indicated that this technology could easily identify the target species at 20% in the background mixture at a 60, 120, 180, or 240 min analysis time with the small database. The results also indicated that the target species could easily be identified at 20% or 6% but could not be identified at 0.6% or 0.06% in either a 240 min analysis or a 30 h analysis with the small database. The effects of the large database were severe on the target species where detection above the background at any concentration used in this study was impossible, though the three other microbes used in this study were clearly identified above the background when analyzed with the large database. This study points to the potential application of this technology for biological threat agent detection but highlights many areas of needed research before the technology will be useful in real world samples.

Biological Warfare↗

Comparison of supercritical fluid extraction and Soxhlet extraction for the determination of polychlorinated biphenyls in environmental matrix standard reference materials.

Supercritical fluid extraction (SFE) was compared to traditional Soxhlet extraction for the determination of polychlorinated biphenyl congeners in three standard reference materials: SRM 1941a (Organics in Marine Sediment), SRM 1944 (New York/New Jersey Waterway Sediment) and SRM 2974 [Organics in Mussel Tissue (Mytilus edulis) (Freeze-Dried)]. The concentrations determined using SFE compared well with the certified concentrations for the majority of the polychlorinated biphenyl congeners.

Animals↗

Optimization of accelerated solvent extraction for polyhalogenated dibenzo-p-dioxins and benzo-p-furans in mineral and environmental matrixes using experimental designs.

This paper deals with the optimization of accelerated solvent extraction (ASE) for the analysis of the polychlorinated dibenzo-p-dioxins, benzo-p-furans (PCDD/Fs), mixed bromine/chlorine-dibenzo-p-dioxins, and benzo-p-furans (so-called MXDD/Fs) in solid samples. Previous theoretical studies have shown that these compounds exhibit similar electronic properties. It is reasonable to assume that there is little difference in the behavior, formation, and toxicity of PCDD/Fs and MXDD/Fs. Indeed, for most of the cases, the affinity is defined by these weak interactions. Only eight native standards are available for the MXDD/Fs; hence, the use of similar compounds (native and (13)C(12)-labeled), such as PCDD/Fs, is required to optimize and to validate experimental methods. This would allow conclusions to be applied for the MXDD/Fs without extended studies involving complex synthesis methods. Experimental design methodology was used to evaluate the influence of five parameters (temperature, pressure, static time, number of cycles, and solvent nature) on the polyhalogenated dibenzodioxin and -furan (PXDD/Fs) extractions in different materials. The extraction profiles and the optimal operating conditions were determined for each matrix from the modeling of extraction performance. The two following effects, the relative peak area and the co-extracted matrix (CEM), were screened in this study. The temperature of extraction was found to be the most important parameter. ASE offers automation and appears to be as efficient as Soxhlet or Soxtet; however, a major benefit was that a 4-fold decrease in extraction time was obtained. Results suggest that extraction efficiency was quantitative with extraction times as low as 15 min for all congeners at 130 degrees C with a mixed solvent (n-hexane/acetone (1/1)). Under these operating conditions, the CEM and the degradation of the highly brominated compounds were minimized. The analysis of some real life samples from municipal solid waste incinerators showed significant amounts of PXDD/Fs.

Journal Article↗

The environmental health matrix: information for use in planning.

Environmental and Health planners and policy makers would benefit from a presentation of the casual relationships and the use of that information for plan development and priority setting. The concept of the Environmental-Health Matrix provides a simple structure for constructing data base of environmental-health research information. The Matrix is organized so that it can be used by either environmental or health planners. Entries in the cells of the Matrix assess the nature of the research evidence and direct the user to summaries of research findings. The initial application of the Matrix as both a guide for a literature review and a data base for planning is discussed.

Environment↗

Determination of As in environmental solid matrix.

In line with recent European environmental guidelines on biomasses, one of the most important parameters to take into account is the As concentration, especially when present in biomasses and complex matrices. The goal of the present study is to give information about possible technical-analytical problems during the determinations of such elements by means of different instrumental spectroscopy techniques, in particular inductively coupled plasma atomic emission (ICP-AES) and atomic absorption (AAS), using two different wavelengths, 188.98 nm and 193.70 nm. In the Laboratory of Hygiene of National Institute of Health in Italy, a specific study has been carried out concerning the determination of As contents in environmental solid matrices, using as reference material BCR 141 R, represented by a calcareous soil. In particular, whereas recovery tests did not show particular drawbacks, difficulties were met in the As detection in reference material. Spectral interference was seen during determination by ICP-AES and matrix interference during determination by AAS, in particular using ETAAS with deuterium background correction and HAAS. Using ETAAS with Zeeman background correction at 193.70 nm, the As line did not show particular matrix interference during the reading of samples.A ring test involving two more laboratories and another certified reference material (IAEA-356 in marine sediment matrix) produced important information about problems of under/over estimation of data. Two different instrumental techniques, ICP-MS and HAAS, confirmed previous data, i.e., overestimation for inductively coupled plasma mass spectrometry and that As values achieved by HAAS were of the same order as the references, but affected by considerable standard deviation. In the light of this study, data achieved on the environmental matrices investigated suggest that the critical step in As determination is the instrumental reading, rather than the mineralization process. Further, each of the methods proposed, apart from ETAAS with Zeeman background correction, presents its own peculiar drawbacks and no particular advantage over other techniques.

Arsenic↗

Standard reference materials (SRMs) for determination of organic contaminants in environmental samples.

For the past 25 years the National Institute of Standards and Technology (NIST) has developed certified reference materials (CRMs), known as standard reference materials (SRMs), for determination of organic contaminants in environmental matrices. Assignment of certified concentrations has usually been based on combining results from two or more independent analytical methods. The first-generation environmental-matrix SRMs were issued with certified concentrations for a limited number (5 to 10) of polycyclic aromatic hydrocarbons (PAHs) and polychlorinated biphenyls (PCBs). Improvements in the analytical certification approach significantly expanded the number and classes of contaminants determined. Environmental-matrix SRMs currently available include air and diesel particulate matter, coal tar, marine and river sediment, mussel tissue, fish oil and tissue, and human serum, with concentrations typically assigned for 50 to 90 organic contaminants, for example PAHs, nitro-substituted PAHs, PCBs, chlorinated pesticides, and polybrominated diphenyl ethers (PBDEs).

Animals↗

Analysis of cartilage differentiation from skeletal muscle grown on bone matrix. III. Environmental regulation of glycosaminoglycan and proteoglycan synthesis.

The ability of numerous nutritional and topographic factors to influence differentiation of embryonic mesenchyme has given rise to several theories which attempt to explain the development of muscle and cartilage from these similar-appearing cells. Some theories are challenged by the observation that a substratum of demineralized bone is capable of supporting the transformation of skeletal muscle into cartilage in vitro and that the potential to form cartilage still resides within cloned myoblasts and fibroblasts of skeletal muscle. In the present study, culture media CMRL-1066, minimal essential medium (MEM), and F-12 provide varied nutritional environments and are tested for their ability to support the morphological and biochemical transformation of skeletal muscle into cartilage. Morphologically, CMRL-1066 reproducibly supports hyaline cartilage formation, whereas MEM does so in only one out of three explants onto demineralized bone, and F-12 is incapable of supporting formation of a hyaline matrix. Biochemically, each medium is sufficient to elicit synthesis of cartilage-like patterns of sulfated glycosaminoglycans and proteoglycan monomer. Synthesis of hyaluronic acid (HA) initially increases in explants grown in CMRL-1066, but decreases prior to chondrogenesis. MEM elicits a similar increase in HA synthesis, but the subsequent decrease is not as rapid. In F-12, synthesis remains depressed throughout the experiment. The data show that increases in HA synthesis occur concurrent with the appearance of fibroblast-like cells, which normally precede chondroblasts. Decreases in HA synthesis correlate well with the onset of chondrogenesis. Explants grown in CMRL-1066 reproducibly from cartilage and synthesize the greatest amounts of proteoglycan aggregate. Those grown in MEM form cartilage infrequently, synthesize reduced amounts of proteoglycan aggregate-like material, and contain greater amounts of HA, of low molecular weight. The data demonstrate that chondrogenesis can be subtly regulated by environmental factors, and such factors regulate both the morphological and biochemical expression of the phenotype through HA synthesis.

Animals↗

Field method for the determination of hexavalent chromium by ultrasonication and strong anion-exchange solid-phase extraction.

A simple, fast, sensitive, and economical field method was developed and evaluated for the determination of hexavalent chromium (CrVI) in environmental and workplace air samples. By means of ultrasonic extraction in combination with a strong anion-exchange solid-phase extraction (SAE-SPE) technique, the filtration, isolation, and determination of CrVI in the presence of trivalent chromium (CrIII) and potential interferents was achieved. The method entails (1) ultrasonication in basic ammonium buffer solution to extract CrVI from environmental matrixes; (2) SAE-SPE to separate CrVI from CrIII and interferences; (3) elution/acidification of the eluate; (4) complexation of chromium with 1,5-diphenylcarbazide; and (5) spectrophotometric determination of the colored chromium-diphenylcarbazone complex. Several critical parameters were optimized in order to effect the extraction of both soluble (K2CrO4) and insoluble (PbCrO4) forms of CrVI without inducing CrIII oxidation or CrVI reduction. The method allowed for the dissolution and purification of CrVI from environmental and workplace air sample matrixes for up to 24 samples simultaneously in less than 90 min (including ultrasonication). The results demonstrated that the method was simple, fast, quantitative, and sufficiently sensitive for the determination of occupational exposures of CrVI. The method is applicable for on-site monitoring of CrVI in environmental and industrial hygiene samples.

Air Pollutants, Occupational↗