Polymer solutions and entropic-based systems for double-stranded DNA capillary electrophoresis and microchip electrophoresis.

We give an overview of recent development of low-viscosity polymer solutions and entropic trapping networks for double-stranded DNA (dsDNA) separations by conventional capillary electrophoresis and microchip electrophoresis. Theoretical models for describing separation mechanisms, commonly used noncross-linked polymer solutions, thermoresponsive (viscosity-adjustable) polymer solutions, and novel entropic trapping networks are included. The thermoresponsive polymer solutions can be loaded at one temperature into microchannels at lower viscosities, and used in separation at another temperature at entanglement threshold concentrations and higher viscosities. The entropic-based separations use only arrays of regular obstacles acting as size-separations and do not need viscous polymer solutions. These progresses have potential in integration to automated capillary and microfluidic chip systems, enabling better reusability of separation microchannels, much shorter DNA separation times, and higher reproducibility due to less matrix degradation.

Electrophoresis, Capillary↗

Determination of vitamin C and preservatives in beverages by conventional capillary electrophoresis and microchip electrophoresis with capacitively coupled contactless conductivity detection.

The separation and detection of commonly used preservatives (benzoate, sorbate) and vitamin C by both conventional CE and microchip electrophoresis with capacitively coupled contactless conductivity detection is presented. The separation was optimized by adjusting the pH-value of the buffer and the use of hydroxypropyl-beta-CD (HP-beta-CD) and CTAB as additives. For conventional CE, optimal separation conditions were achieved in a histidine/tartrate buffer at pH 6.5, containing 0.025% HP-beta-CD and 0.1 mM CTAB. LOD ranged from 0.5 to 3 mg/L (S/N = 3) and the RSDs for migration time and peak area were less than 0.1 and 2%, respectively. A considerable reduction of analysis time can be accomplished by using microchip electrophoresis without significant loss in sensitivity under optimal separation conditions. A histidine/tartrate buffer at pH 6.5, incorporating 0.06% HP-beta-CD and 0.25 mM CTAB, gave detection limits ranging between 3 and 10 mg/L and satisfactory reproducibilities of < or =0.4% for the migration time and < or =3.5% for the peak area. The methods developed are useful for the quantitative determination of food additives in real samples such as soft drinks and vitamin C tablets.

2-Hydroxypropyl-beta-cyclodextrin↗

Rapid analysis of atorvastatin calcium using capillary electrophoresis and microchip electrophoresis.

In this work, a capillary electrophoretic method for the rapid quantitation of atorvastatin (AT) in a lipitor tablet was investigated and developed. Method development included studies of the effect of applied potential, buffer concentration, buffer pH, and hydrodynamic injection time on the electrophoretic separation. The method was validated with regard to linearity, precision, specificity, LOD, and LOQ. The optimum electrophoretic separation conditions were 25 mM sodium acetate buffer at pH 6, with a separation voltage of 25 kV using a 50 microm capillary of 33 cm total length. Sodium diclofenac was used as an internal standard. Analysis of AT in a commercial lipitor tablet by electrophoresis gave quite high efficiency, coupled with an analysis time of less than 1.2 min in comparison to LC. Once the separation was optimized on capillary, it was further miniaturized to a microchip platform, with linear imaging UV detection using microchip electrophoresis (MCE). Linear imaging UV detection allowed for real-time monitoring of the analyte movement on chip, so that the optimum separation time could be easily determined. This microchip electrophoretic method was compared to the CE method with regard to speed, efficiency, precision, and LOD. This work represents the most rapid and first reported analysis of AT using MCE.

Atorvastatin↗

High-throughput genotyping by microchip electrophoresis.

Easy applicability of modern microfabrication technology to electrophoresis microchips has initiated a rapidly moving interdisciplinary field in analytical chemistry. Electric field-mediated separations in microfabricated devices are significantly faster than conventional electrophoresis methods and are usually completed in seconds to minutes. The flexibility of fluidic manipulations in electrophoresis microchips allows the use of a variety of separation techniques and conditions. In this study, large-scale genotyping of the repeat polymorphism in the regulatory (promoter) region of the serotonin transporter gene 5-HTT linked polymorphic region (5-HTTLPR) was attempted using polymerase chain reaction (PCR) amplification followed by rapid microchip electrophoresis analysis of the amplicons.

DNA↗

Low viscous separation media for genomics and proteomics analysis on microchip electrophoresis system.

Microchip electrophoresis has widely grown during the past few years, and it has showed a significant result as a strong separation tool for genomic as well as proteomic researches. To enhance and expand the role of microchip electrophoresis, several studies have been proposed especially for the low viscous separation media, which is an important factor for the success of microchip with its narrow separation channels. In this paper we show an overview for the done researches in the field of low viscous media developed for the use in microchip electrophoresis. For genomic separation studies polyhydroxy additives have been used enhance the separation of DNA at low polymer concentration of HPMC (Hydroxypropylmethyl cellulose) which could keep the viscosity low. Mixtures of poly(ethylene oxide) as well as Hydroxyporpyl cellulose have been successfully introduced for chip separation. Furthermore high molecular mass polyacrylamides at low concentrations have been studied for DNA separation. A mixture of polymer nanoparticle with conventional polymers could show a better resolution for DNA at low concentration of the polymer. For the proteomic field isoelectric focusing on chip has been well overviewed since it is the most viscous separation media which is well used for the protein separation. The different types of isoelectric focusing such as the ampholyte-free type, the thermal type as well as the ampholyte-depended type have been introduced in this paper. Isoelectric focusing on chip with its combination with sodium dodecyl sulfate (SDS) page or free solution could give a better separation. Several application for this low viscous separation medias for either genomic or proteomic could clearly show the importance of this field.

Animals↗

Rapid analysis of amino acids in Japanese green tea by microchip electrophoresis using plastic microchip and fluorescence detection.

Microchip electrophoresis for the short-time analysis of amino acids in Japanese green tea was developed. The amino acids in Japanese green tea were derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F). The derivatives were filtered and directly analyzed by electrophoresis on a plastic microchip with a 31-mm long separation channel with fluorescence detection. Amino acid analysis of Japanese green tea was improved by removing polyphenols using a polyvinylpolypyrrolidone pretreatment. Elution profiles of NBD-amino acids were examined under different running buffer conditions, and the sodium dodecyl sulphate in the running buffer exhibited a dramatically high-separation efficiency of amino acids by inhibiting their adsorption on the channel walls. Under the optimized conditions (5 mM phosphate buffer (pH 5.5) containing 0.05 mM sodium dodecylsulfate as running buffer), the main amino acids contained in Japanese green tea were well separated within 2 min, and theanine (1475 mg/100 g tea leaf), Arg (408 mg/100 g tea leaf) and Gln (217 mg/100 g tea leaf) were detected in Japanese green tea.

Acetonitriles↗

Simultaneous determination of glutathione and reactive oxygen species in individual cells by microchip electrophoresis.

A microchip electrophoresis method was developed for simultaneous determination of reactive oxygen species (ROS) and reduced glutathione (GSH) in the individual erythrocyte cell. In this method, cell sampling, single-cell loading, docking, lysing, and capillary electrophoretic separation with LIF detection were integrated on a microfluidic chip with crossed channels. ROS was labeled with dihydrorhodamine 123 in the intact cell, while GSH was on-chip labeled with 2,3-naphthalene-dicarboxaldehyde, which was included in the separation medium. On-chip electrical lysis, characterized by extremely fast disruption of the cellular membrane (<40 ms), was exploited to minimize enzymatic effects on analyte concentrations during the determination. The microfluidic network was optimized to prevent cell leaking from the sample reservoir (S) into separation during the separation phase. The structure of the S was modified to avoid blockage of its outlet by deposited cells. Detection limits of 0.5 and 6.9 amol for ROS and GSH, respectively, were achieved. The average cell throughput was 25 cells/h. The effectiveness of the method was demonstrated in the simultaneous determination of GSH and ROS in individual cells and the variations of cellular GSH and ROS contents in response to external stimuli.

Adult↗

Simultaneous and ultrarapid determination of reactive oxygen species and reduced glutathione in apoptotic leukemia cells by microchip electrophoresis.

A microchip electrophoresis method coupled with laser-induced fluorescence (LIF) detection was established for simultaneous determination of two kinds of intracellular signaling molecules (reactive oxygen species, ROS, and reduced glutathione, GSH) related to apoptosis and oxidative stress. As the probe dihydrorhodamine-123 (DHR-123) can be converted intracellularly by ROS to the fluorescent rhodamine-123 (Rh-123), and the probe naphthalene-2,3-dicarboxaldehyde (NDA) can react quickly with GSH to produce a fluorescent adduct, rapid determination of Rh-123 and GSH was achieved on a glass microchip within 27 s using a 20 mM borate buffer (pH 9.2). The established method was tested to measure the intracellular ROS and GSH levels in acute promyelocytic leukemia (APL)-derived NB4 cells. An elevation of intracellular ROS and depletion of GSH were observed in apoptotic NB4 cells induced by arsenic trioxide (As(2)O(3)) at low concentration (1-2 microM). Buthionine sulfoximine (BSO), in combination with As(2)O(3) enhanced the decrease of reduced GSH to a great extent. The combined treatment of As(2)O(3) and hydrogen peroxide (H(2)O(2)) led to an inverse relationship between the concentrations of ROS and GSH obtained, showing the proposed method can readily evaluate the generation of ROS, which occurs simultaneously with the consumption of the inherent antioxidant.

Apoptosis↗

Dual-electrode electrochemical detection for poly(dimethylsiloxane)-fabricated capillary electrophoresis microchips.

The development of a poly(dimethylsiloxane)-based (PDMS-based) microchip electrophoresis system employing dual-electrode electrochemical detection is described. This is the first report of dual-electrode electrochemical detection in a microchip format and of electrochemical detection on chips fabricated from PDMS. The device described in this paper consists of a top layer of PDMS containing the separation and injection channels and a bottom glass layer onto which gold detection electrodes have been deposited. The two layers form a tight reversible seal, eliminating the need for high-temperature bonding, which can be detrimental to electrode stability. The channels can also be temporarily removed for cleaning, significantly extending the lifetime of the chip. The performance of the chip was evaluated using catechol as a test compound. The response was linear from 10 to 500 microM with an LOD (S/N = 3) of 4 microM and a sensitivity of 45.9 pA/microM. Collection efficiencies for catechol ranged from 28.7 to 25.9% at field strengths between 200 and 400 V/cm. Dual-electrode detection in the series configuration was shown to be useful for the selective monitoring of species undergoing chemically reversible redox reactions and for peak identification in the electropherogram of an unresolved mixture.

Dimethylpolysiloxanes↗

Integration of combined heteroduplex/restriction fragment length polymorphism analysis on an electrophoresis microchip for the detection of hereditary haemochromatosis.

This work describes an integrated method of enzymatic digestion, heteroduplex analysis (HA) and electrophoretic sizing on a microfluidic chip. HA techniques based on microchip electrophoresis are capable of the high sensitivity detection of subtle mutations such as single nucleotide polymorphisms (SNPs) but are not readily able to detect homozygous mutant genotypes. Such homozygous conditions are commonly encountered with the gene implicated in hereditary haemochromatosis, HFE. We employed the restriction fragment length polymorphism (RFLP) method of mutation detection to complement the HA method in a rapid novel on-chip procedure that separated digested PCR fragments to reliably determine the presence or absence of the most important mutations associated with haemochromatosis. This method was able to distinguish the homozygous mutant, heterozygous and homozygous wildtype genotypes. The mutations investigated here (C282Y, H63D and S65C) are often the mutation targets used in the genetic testing for haemochromatosis. This method provides the extremely specific digestion methods needed for the analysis of the known and relatively common mutations that have a significant probability of occurring in a homozygous form. However, the high sensitivity of the HA method is useful in detecting other mutations of lesser likelihood which, by virtue of their rarity, are likely to be present only in a heterozygous form. Although the conventional methods of analysing these mutations require as much as a day to perform, this microchip method, even without robotics or multiplexed operation, can be performed in about 10 min per sample.

Electrophoresis↗

Towards disposable lab-on-a-chip: poly(methylmethacrylate) microchip electrophoresis device with electrochemical detection.

A fully disposable microanalytical device based on combination of poly(methylmethacrylate) (PMMA) capillary electrophoresis microchips and thick-film electrochemical detector strips is described. Variables influencing the separation efficiency and amperometric response, including separation voltage or detection potential are assessed and optimized. The versatility, simplicity and low-cost advantages of the new design are coupled to an attractive analytical performance, with good precision (relative standard deviation RSD = 1.68% for n = 10). Applicability for assays of mixtures of hydrazine, phenolic compounds, and catecholamines is demonstrated. Such coupling of low-cost PMMA-based microchips with thick-film electrochemical detectors holds great promise for mass production of single-use micrototal analytical systems.

Catecholamines↗

Analysis of inorganic and small organic ions with the capillary electrophoresis microchip.

Capillary electrophoresis microchip devices are receiving considerable attention due to their versatility, portability, and sample handling capabilities. This article is a comprehensive review of the analysis of inorganic and small, charged organic species on microchip platforms. The application of conductivity, amperometry, laser-induced fluorescence, absorbance, and chemiluminescence detection methods are discussed. The potential utilization of these devices for miniaturized analytical systems is described.

Electrochemistry↗

Analysis of DNA polymorphisms on the human Y-chromosome by microchip electrophoresis.

Validation of microchip electrophoresis in DNA analysis has been carried out using an Agilent 2100 Bioanalyzer. With a DNA 500 Assay Kit, the reproducibility and accuracy of fragment sizing of a 10 bp DNA ladder have been shown to be satisfactory with the relative standard deviation and the relative error mostly below 1.0 and 5.0% (n = 12), respectively. Both intraday and interday validations of fragment sizing and quantitation have also been performed with a 7500 Assay Kit (n = 48). Although the results of quantitation are not as good as that of sizing, due to the manual introduction of samples and markers into the chip wells, they are still sufficient to carry out further analyses of practical samples. Based on such reliable results, fast analysis of DNA polymorphisms on the human Y-chromosome has been realized with microchip electrophoresis. The total analysis times of three genomic polymorphisms on the Y-chromosome, Y Alu polymorphism, 47z/StuI, and 12f2, are all within 100 s, and the relative standard deviation and relative error of fragment sizes are below 3.5 and 3.7%, respectively. In addition, a mixture of nine DNA markers on the human Y-chromosome related to examine the cause of spermatogenic failure have been separated successfully with the smallest fragment size difference of 7 bp. Our results demonstrate the potential of microchip electrophoresis in polymorphism analysis with the advantages of high speed, good reproducibility, high precision, and high resolution.

Chromosomes, Human, Y↗

Capillary and microchip electrophoresis for rapid detection of known mutations by combining allele-specific DNA amplification with heteroduplex analysis.

BACKGROUND: Detection of mutations by gel electrophoresis and allele-specific amplification by PCR (AS-PCR) is not easily scaled to accommodate a large number of samples. Alternative electrophoretic formats, such as capillary electrophoresis (CE) and microchip electrophoresis, may provide powerful platforms for simple, fast, automated, and high-throughput mutation detection after allele-specific amplification. METHODS: DNA samples heterozygous for four mutations (185delAG, 5382insC, 3867G-->T, and 6174delT) in BRCA1 and BRCA2, and homozygous for one mutation (5382insC) in BRCA1 and two mutations (16delAA and 822delG) in PTEN were chosen as the model system to evaluate the capillary and microchip electrophoresis methods. To detect each mutation, three primers, of which one was labeled with the fluorescent dye 6-carboxyfluorescein and one was the allele-specific primer (mutation-specific primer), were used to amplify the DNA fragments in the range of 130-320 bp. AS-PCR was combined with heteroduplex (HD) analysis, where the DNA fragments obtained by AS-PCR were analyzed with the conditions developed for CE-based HD analysis (using a fluorocarbon-coated capillary and hydroxyethylcellulose). The CE conditions were transferred into the microchip electrophoresis format. RESULTS: Three genotypes, homozygous wild type, homozygous mutant, and heterozygous mutant, could be identified by CE-based AS-PCR-HD analysis after 10-25 min of analysis time. Using the conditions optimized with CE, we translated the AS-PCR-HD analysis mutation detection method to the microchip electrophoresis format. The detection of three heterozygous mutations (insertion, deletion, and substitution) in BRCA1 could be accomplished in 180 s or less. CONCLUSIONS: It is possible to develop a CE-based method that exploits both AS-PCR and HD analysis for detecting specific mutations. Fast separation and the capacity for automated operation create the potential for developing a powerful electrophoresis-based mutation detection system. Fabrication of multichannel microchip platforms may enable mutation detection with high throughput.

BRCA1 Protein↗

A design of nanosized PEGylated-latex mixed polymer solution for microchip electrophoresis.

We report here advanced microchip electrophoresis using a nanoparticle doped polymer solution that enables greater separation of DNA. The proposed system is simple and effective without any new apparatus or complicated procedures. Various amounts and sizes (80 nm, 110 nm, and 193 nm) of polymer nanoparticle solutions (PEGylated-latex) were mixed with a conventional polymer solution for microchip electrophoresis. When a 0.49 wt% hydroxyl propyl methyl cellulose (HPMC) buffer solution was mixed with a 2.25 wt% 80 nm-PEGylated-latex a higher separation efficiency and a higher mobility of a wider molecular range of dsDNA (10 bp to 2 kbp) was achieved under low viscosity conditions (<5.5 cP) than in conventional 0.7% HPMC. The separation performance was dependent on the particle size and concentration. Furthermore, the effectiveness of the larger PEGylated-latex (193 nm) was not as high as the smaller one (80 to 110 nm). The observed separation improvement by polymer solution with latex-nanoparticles seems to derive from the balance between wider polymer mesh size and the structural obstacles of particles in the buffer.

DNA↗

Measurement of monomolecular binding constants of neutral phenols into the beta-cyclodextrin by continuous frontal analysis in capillary and microchip electrophoresis via a competitive assay.

Measurement of binding constant by chip electrophoresis is a very promising technique for the high throughput screening of non-covalent interactions. Among the different electrophoretic methods available that yield the binding parameters, continuous frontal analysis is the most appropriate for a transposition from capillary electrophoresis (CE) to microchip electrophoresis. Implementation of this methodology in microchip was exemplified by the measurement of inclusion constants of 2-naphtalenesulfonate and neutral phenols (phenol, 4-chlorophenol and 4-nitrophenol) into beta-cyclodextrin by competitive assays. The issue of competitor choice is discussed in relation to its appropriateness for proper monitoring of the interaction.

Electrophoresis, Capillary↗

Conformational separation of monosaccharides of glycoproteins labeled with 2-aminoacrydone using microchip electrophoresis.

The conformational separation of monosaccharides labeled with fluorescent 2-aminoacrydone (AMAC) was performed by electrophoresis on a plastic microchip with light-emitting diode confocal fluorescence detection. The AMAC-labeled five neutral monosaccharide mixture (D-glucose (Glc), D-mannose, D-galactose, L-fucose, and D-xylose) or two amino monosaccharide mixture (N-acetyl-D-glucosamine and N-acetyl-D-galactosamine) were well separated at pH 8.5 and 0.5% w/v methylcellulose of 200 mM borate buffer conditions using microchip electrophoresis. The separation was successfully performed considering the difference in stability of the complex between the hydroxyl residue of the monosaccharide and borate ions, and we found that 200 mM and pH 8.5 of borate buffer conditions were critical. High-speed separation for the neutral monosaccharides (50 s) and for amino monosaccharides (70 s) was attained at a 400 V/cm of electric field condition, showing all peak resolutions were greater than 0.9% and RSD of mobility were less than 1.9%. The detection limits of 0.86 microM for Glc and <1 microM for all other monosaccharides were enhanced with the addition of 0.5% w/v methylcellulose to the buffer. These attainments are fully compatible with conventional CE. The analysis of the subtle differences in the conformational stability and the value of the hydroxyl residue of the borate complex allowed the development of an efficient prospective tool for attaining high-resolution separation of monosaccharide mixtures having complicated and analogous conformations.

Aminoacridines↗

Microchip electrophoresis for chiral separations.

Microchip electrophoresis (MCE) is a promising new technique for the separation of enantiomers. This recently introduced technique enables chiral separations to be performed in seconds on tiny micromachined devices. This review is intended to give a brief introduction into the principles of chiral separations with MCE with regard to methodology and instrumentation. Different approaches to realize chiral separations in microfluidic devices are described and discussed. This review gives an overview of original work done in this field with emphasis on approaches to improve detection and resolution in chiral MCE.

Electrophoresis, Capillary↗