Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Electromagnetic Phenomena”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

The role of Biot slow waves in electroseismic wave phenomena.

The electromagnetic fields that are generated as a spherical seismic wave (either P or S) traverses an interface separating two porous materials are numerically modeled both with and without the generation of Biot slow waves at the interface. In the case of an incident fast-P wave, the predicted electric-field amplitudes when slow waves are neglected can easily be off by as much as an order of magnitude. In the case of an incident S wave, the error is much smaller (typically on the order of 10% or less) because not much S-wave energy gets converted into slow waves. In neglecting the slow waves, only six plane waves (reflected and transmitted fast-P, S, and EM waves) are available with which to match the eight continuity conditions that hold at each interface. This overdetermined problem is solved by placing weights on the eight continuity conditions so that those conditions that are most important for obtaining the proper response are emphasized. It is demonstrated that when slow waves are neglected, it is best to also neglect the continuity of the Darcy flow and fluid pressure across an interface. The principal conclusion of this work is that to properly model the electromagnetic (EM) fields generated at an interface by an incident seismic wave, the full Biot theory that allows for generation of slow waves must be employed.

Elasticity↗

Spontaneous ultraweak photon emission from biological systems and the endogenous light field.

Still one of the most astonishing biological electromagnetic phenomena is the ultraweak photon emission (UPE) from living systems. Organisms and tissues spontaneously emit measurable intensities of light, i.e. photons in the visible part of the electromagnetic spectrum (380-780 nm), in the range from 1 to 1,000 photons x s-1 x cm-2, depending on their condition and vitality. It is important not to confuse UPE from living systems with other biogenic light emitting processes such as bioluminescence or chemiluminescence. This article examines with basic considerations from physics on the quantum nature of photons the empirical phenomenon of UPE. This leads to the description of the non-thermal origin of this radiation. This is in good correspondence with the modern understanding of life phenomena as dissipative processes far from thermodynamic equilibrium. UPE also supports the understanding of life sustaining processes as basically driven by electromagnetic fields. The basic features of UPE, like intensity and spectral distribution, are known in principle for many experimental situations. The UPE of human leukocytes contributes to an endogenous light field of about 1011 photons x s-1 which can be influenced by certain factors. Further research is needed to reveal the statistical properties of UPE and in consequence to answer questions about the underlying mechanics of the biological system. In principle, statistical properties of UPE allow to reconstruct phase-space dynamics of the light emitting structures. Many open questions remain until a proper understanding of the electromagnetic interaction of the human organism can be achieved: which structures act as receptors and emitters for electromagnetic radiation? How is electromagnetic information received and processed within cells?

Biophysical Phenomena↗

MESA: a new configuration for measuring electromagnetic field fluctuations.

This paper describes how the multi-energy sensor array has been refitted to meet the needs of measuring geomagnetic and other types of electromagnetic phenomena in an environment. This portable laptop computer system was designed to measure the interaction of multiple frequencies with the psychological and physiological processes that underlie human exposure to electromagnetic fields across the spectra. New sensors and analytical software have been implemented in the new configuration.

Computer Systems↗

[Normative aspects of sources].

The human body is more and more exposed to the electromagnetic phenomena generated by all domestic and professional electric appliances. This problem "EMF and health" is devoted to the possible effects known as "biological" and the possibilities of disturbances of the medical implants. Although many studies still did not give conclusions on these long-term effects, international standardisation is in progress and could lead to a difficult use of electricity such that it currently exists. The modelling of the phenomena in the human body can contribute to a better knowledge of the interactions field-man and to the development of more realistic standards.

Electromagnetic Fields↗

Computational analysis of the high pass birdcage resonator: finite difference time domain simulations for high-field MRI.

In this work, a finite difference time domain (FDTD) algorithm is validated at 1.5 tesla using the standard GE Signa quadrature head coil and a muscle phantom. The electrical characteristics of the birdcage head coil are then calculated for the linear and quadrature cases. Unlike previous computational analysis which assume idealized currents on the end rings and the struts of the resonator, a complete computational analysis is provided. This treatment considers the coupling between the resonator and the sample and includes a real coil excitation, a complete current derivation, and a thorough description of both B(1) fields and RF radiation. With this improvement, electromagnetic phenomena such as radiation, standing wave currents on the wires, and field inhomogeneities due to interactions between the coil and the load inside the coil are observed. At 200 MHz, it is demonstrated that this particular coil does not work well due to radiation and non-uniformities on the struts of the device. Also, at this frequency magnetic field inhomogeneities become large when the coil is loaded with a phantom.

Computer Simulation↗

All-metallic three-dimensional photonic crystals with a large infrared bandgap.

Three-dimensional (3D) metallic crystals are promising photonic bandgap structures: they can possess a large bandgap, new electromagnetic phenomena can be explored, and high-temperature (above 1,000 degrees C) applications may be possible. However, investigation of their photonic bandgap properties is challenging, especially in the infrared and visible spectrum, as metals are dispersive and absorbing in these regions. Studies of metallic photonic crystals have therefore mainly concentrated on microwave and millimetre wavelengths. Difficulties in fabricating 3D metallic crystals present another challenge, although emerging techniques such as self-assembly may help to resolve these problems. Here we report measurements and simulations of a 3D tungsten crystal that has a large photonic bandgap at infrared wavelengths (from about 8 to 20 microm). A very strong attenuation exists in the bandgap, approximately 30 dB per unit cell at 12 microm. These structures also possess other interesting optical properties; a sharp absorption peak is present at the photonic band edge, and a surprisingly large transmission is observed in the allowed band, below 6 microm. We propose that these 3D metallic photonic crystals can be used to integrate various photonic transport phenomena, allowing applications in thermophotovoltaics and blackbody emission.

Journal Article↗

A subfemtotesla multichannel atomic magnetometer.

The magnetic field is one of the most fundamental and ubiquitous physical observables, carrying information about all electromagnetic phenomena. For the past 30 years, superconducting quantum interference devices (SQUIDs) operating at 4 K have been unchallenged as ultrahigh-sensitivity magnetic field detectors, with a sensitivity reaching down to 1 fT Hz(-1/2) (1 fT = 10(-15) T). They have enabled, for example, mapping of the magnetic fields produced by the brain, and localization of the underlying electrical activity (magnetoencephalography). Atomic magnetometers, based on detection of Larmor spin precession of optically pumped atoms, have approached similar levels of sensitivity using large measurement volumes, but have much lower sensitivity in the more compact designs required for magnetic imaging applications. Higher sensitivity and spatial resolution combined with non-cryogenic operation of atomic magnetometers would enable new applications, including the possibility of mapping non-invasively the cortical modules in the brain. Here we describe a new spin-exchange relaxation-free (SERF) atomic magnetometer, and demonstrate magnetic field sensitivity of 0.54 fT Hz(-1/2) with a measurement volume of only 0.3 cm3. Theoretical analysis shows that fundamental sensitivity limits of this device are below 0.01 fT Hz(-1/2). We also demonstrate simple multichannel operation of the magnetometer, and localization of magnetic field sources with a resolution of 2 mm.

Magnetics↗

Relationship between radiographic measurements of reconstructed hip joint position and the Trendelenburg sign.

We evaluated 60 limbs, including 34 primary total hip arthroplasties in 30 patients (mean age, 56 years) at a minimum of 2 years postoperatively. Femoral offset ratio (%FO) was calculated by dividing the femoral offset by the distance between the centers of the bilateral femoral heads on radiographs. The tilt angle of the pelvis by the Trendelenburg test was measured using the magnetic sensor system. In the limbs having a negative Trendelenburg sign after reconstruction, the %FO averaged 20.1% (range, 14.7% to 24.7%), and the tilt angle of the pelvis averaged +0.8 degrees (range, -1.0 degrees to +5.0 degrees ). The tilt angle of the pelvis correlated positively with %FO (P=.0160, r=0.407). The reconstructed hip joint position is crucial to improve hip abductor function.

Adolescent↗

A comparison of the effect of ski sidecut on three-dimensional knee joint kinematics during a ski run.

The popularity of alpine skis with large sidecuts has increased dramatically in the last few years. However, little scientific data exists regarding the effect of these skis on certain human factors. The purpose of this study was to compare three-dimensional knee joint motions during entire ski runs while skiing on two skis with a large difference in sidecut (Elan SCX and Elan RP90). Five, expert male skiers performed three runs on each ski. Three-dimensional knee joint motion was collected throughout each run using a portable, magnetic motion tracking system. Twenty-four turns from each run were analyzed for joint motion characteristics. The results indicated that no statistically significant differences in knee joint range of motion or angular velocities were found to exist between the Elan SCX and Elan RP90 during normal skiing maneuvers. Further research is needed on the effect of ski sidecut on knee joint kinematics while skiing on varied terrain and/or with different skiing styles. In addition, similar studies comparing the effect of ski sidecut on metabolic cost and effect on injury rates are also needed.

Adult↗

Electric field prediction for a human body-electric machine system.

A system consisting of an electric machine and a human body is studied and the resulting electric field is predicted. A 3-phase induction machine operating at full load is modeled considering its geometry, windings, and materials. A human model is also constructed approximating its geometry and the electric properties of tissues. Using the finite element technique the electric field distribution in the human body is determined for a distance of 1 and 5 m from the machine and its effects are studied. Particularly, electric field potential variations are determined at specific points inside the human body and for these points the electric field intensity is computed and compared to the limit values for exposure according to international standards.

Biomechanical Phenomena↗

Temporal analysis of moving DC electric fields in aquatic media.

Many aquatic vertebrates can sense the weak electric fields generated by other animals and may also sense geoelectric or electromagnetic phenomena for use in orientation. All these sources generate stationary (dc) fields. In addition, fields from animals are modulated by respiration and other body movements. Since electroreceptors are insensitive to a pure dc field, it has been suggested that the ac modulation carries most of the relevant information for electrosensory animals. However, in a natural situation pure dc fields are rare since any relative movement between source and receiver will transform a dc field into a time varying signal. In this paper, we will describe the properties of such signals and how they are filtered at the first stage of electrosensory information processing in the brain. We will show that the signal perceived by an animal traversing a dc electric field contains all the information necessary to reconstruct the distance to the source and that the signal conditioning algorithms are perfectly adapted to preserve such information.

Algorithms↗

Radiation pressure of light pulses and conservation of linear momentum in dispersive media.

We derive an expression for the Minkowski momentum under conditions of dispersive susceptibility and permeability, and compare it to the Abraham momentum in order to test the principle of conservation of linear momentum when matter is present. We investigate cases when an incident pulse interacts with a variety of structures, including thick substrates, resonant, free-standing, micron-sized multilayer stacks, and negative index materials. In general, we find that for media only a few wavelengths thick the Minkowski and Abraham momentum densities yield similar results. For more extended media, including substrates and Bragg mirrors embedded inside thick dielectric substrates, our calculations show dramatic differences between the Minkowski and Abraham momenta. Without exception, in all cases investigated the instantaneous Lorentz force exerted on the medium is consistent only with the rate of change of the Abraham momentum. As a practical example, we use our model to predict that electromagnetic momentum and energy buildup inside a multilayer stack can lead to widely tunable accelerations that may easily reach and exceed 10(10) m/s(2) for a mass of 10(-5) g. Our results suggest that the physics of the photonic band edge and other similar finite structures may be used as a testing ground for basic electromagnetic phenomena such as momentum transfer to macroscopic media.

Journal Article↗

Metamaterials and negative refractive index.

Recently, artificially constructed metamaterials have become of considerable interest, because these materials can exhibit electromagnetic characteristics unlike those of any conventional materials. Artificial magnetism and negative refractive index are two specific types of behavior that have been demonstrated over the past few years, illustrating the new physics and new applications possible when we expand our view as to what constitutes a material. In this review, we describe recent advances in metamaterials research and discuss the potential that these materials may hold for realizing new and seemingly exotic electromagnetic phenomena.

Journal Article↗