Finite element modeling of electrode-skin contact impedance in electrical impedance tomography.

In electrical impedance tomography (EIT), we inject currents through and measure voltages from an array of surface electrodes. The measured voltages are sensitive to electrode-skin contact impedance because the contact impedance and the current density through this contact impedance are both high. We used large electrodes to provide a more uniform current distribution and reduce the contact impedance. A large electrode differs from a point electrode in that it has shunting and edge effects which cannot be modeled by a single resistor. We used the finite element method (FEM) to study the electric field distributions underneath an electrode, and developed three models: a FEM model, a simplified FEM model and a weighted load model. We showed that the FEM models considered both shunting and edge effects and matched closely the experimental measurements. FEM models for electrodes can be used to improve the performance of an electrical impedance tomography reconstruction algorithm.

Algorithms↗

Factors affecting electrode-gel-skin interface impedance in electrical impedance tomography.

The magnitude, mismatch and temporal variations of the electrode-gel-skin interface impedance can cause problems in electrical impedance tomography (EIT) measurement. It is shown that at the high frequencies generally encountered in EIT the capacitive properties of the electrode interface, and especially those of the skin, are of primary importance. A wide range of techniques are reviewed that could possibly be used to minimise these problems. These techniques include the use of skin preparation, penetration enhancers, temperature and electrical impulses. Although several of these techniques appear very attractive, they are not without serious potential drawbacks. A combination of some of these techniques may well hold the key to success.

Electric Impedance↗

Temperature dependence of tissue impedivity in electrical impedance tomography of cryosurgery.

The temperature-dependent impedivity of rat liver, transverse abdominal muscle and full skin was determined in vitro as a function of frequency across the temperature range 5 degrees C to 37 degrees C and from 100 Hz to 10 kHz. This study was motivated by an increasing interest in using electrical impedance tomography (EIT) for imaging of cryosurgery and a lack of applicable data in the hypothermic range. Using a controlled-temperature impedance analyzer, it was found that as the temperature is reduced the resulting increase in tissue impedivity is more pronounced at low frequencies and that the beta dispersion, resulting from cell membrane polarization, shifts to lower frequencies. With these new data a simple case study of EIT of liver cryosurgery was examined, using a finite-element model incorporating the Pennes bio-heat equation, to determine the impact of this behavior on imaging accuracy. Overestimation of the ice-front position was found to occur if the EIT system ignored the effects of the low-temperature zone surrounding the frozen tissue. This error decreases with increasing blood perfusion and with higher measurement frequencies.

Abdominal Muscles↗

Monitoring patients with left ventricular failure by electrical impedance tomography.

Acute left ventricular failure (LVF) is a common medical emergency but detection and monitoring of pulmonary oedema remains problematic. Fluid is an important determinant of tissue impedance. Electrical impedance tomography (EIT) is a non-invasive technique allowing localisation of impedance changes within tissue. We have investigated the relationship between LVF and the electrical impedance of lung tissue. Twenty patients with a clinical diagnosis of acute left ventricular failure were compared with 30 normal subjects. Patients were monitored using serial chest radiographs and electrical impedance tomography measurements of lung impedance during hospital admission. Radiographs were graded according to the severity of pulmonary oedema by two independent radiologists. Lung impedance was significantly (P<0.0001) lower than normal in patients with left ventricular failure. Values returned towards the normal range as LVF resolved. There was a similar improvement in the score of the chest radiographs. The electrical impedance of the lung is low in left ventricular failure and increases following treatment.

Acute Disease↗

Imaging the complex impedance in electrical impedance tomography.

Measuring the reactive component of the bio-impedance enables a full characterisation of the frequency response of a tissue. The amplitude of the reactive component is relatively small in the frequency range generally used in electrical impedance tomography (EIT). Its measurement is therefore more sensitive to errors. At higher frequencies, the amplitude of this component increases, which increases the signal-to-noise ratio. The stray capacitance, however, also increases and the front-end circuit must be designed carefully. The purpose of the present study is to show the feasibility of the collection of data at relatively high frequencies; 31.25 and 250 kHz were used. Both the real and reactive components were used to reconstruct images from capacitive targets. This study suggests that it may be possible to use multifrequency systems to determine the parameters of frequency loci and therefore tissue characterisation.

Electric Conductivity↗

Determinants of thoracic electrical impedance in external electrical cardioversion of atrial fibrillation.

The success of external cardioversion (ECV) of atrial fibrillation depends on generating sufficient transmyocardial current for defibrillation with minimal myocardial injury. Thoracic electrical impedance plays an important role in the relation between the delivered energy and transmyocardial current. This study assessed the determinants of thoracic electrical impedance in ECV of atrial fibrillation. ECV of atrial fibrillation was performed in 80 consecutive patients (mean age 73 +/- 9 years; men 69%; body mass index 26.0 +/- 3.6 kg/m(2)) within 12 months, using biphasic shocks (Multipulse Biowave) delivered through adhesive pads in an anteroposterior position. Thoracic electrical impedance was measured using the first shock. The mean thoracic electrical impedance was 57.7 +/- 12.3 Omega (energy 71 +/- 43 J, current intensity 33 +/- 12 A). Sinus rhythm was immediately restored in 75 patients (94%). Thoracic electrical impedance was greater (60.9 +/- 11.8 vs 51.7 +/- 11.0 Omega, p = 0.001) in patients requiring >1 shock (65%). At multivariate linear regression analysis (R = 0.761, p <0.001), female gender (+9.7 +/- 2.0 Omega, p <0.001), body mass index (+1.5 +/- 0.3 for a 1 kg/m(2) increase, p <0.001), hemoglobin concentration (+1.9 +/- 0.6 for a 1 g/dl increase, p = 0.004), and the presence of chronic heart failure (-5.3 +/- 2.0 Omega, p = 0.009) were independent predictors of thoracic electrical impedance. In conclusion, to increase ECV efficacy and minimize complications, the delivered energy should be adjusted in accordance with the clinical variables that independently affect thoracic electrical impedance and, hence, transmyocardial current.

Aged↗

A Kalman filter approach to track fast impedance changes in electrical impedance tomography.

In electrical impedance tomography (EIT), an estimate for the cross-sectional impedance distribution is obtained from the body by using current and voltage measurements made from the boundary. All well-known reconstruction algorithms use a full set of independent current patterns for each reconstruction. In some applications, the impedance changes may be so fast that information on the time evolution of the impedance distribution is either lost or severely blurred. In this paper, we propose an algorithm for EIT reconstruction that is able to track fast changes in the impedance distribution. The method is based on the formulation of EIT as a state-estimation problem and the recursive estimation of the state with the aid of the Kalman filter. The performance of the proposed method is evaluated with a simulation of human thorax in a situation in which the impedances of the ventricles change rapidly. We show that with optimal current patterns and proper parameterization, the proposed approach yields significant enhancement of the temporal resolution over the conventional reconstruction strategy.

Algorithms↗

Electrical impedance tomography.

Electrical impedance tomography (EIT) is a technique which allows cross-sectional images related to the local electrical impedance within an object to be reconstructed from sets of measurements made on its surface. The main drive behind the development of EIT has been its possible application in medical imaging, as biological tissues are known to exhibit a wide range of electrical impedance and many physiological events are accompanied by electrical impedance changes. This article reviews the technical aspects of EIT as a medical imaging modality, and considers the range of applications over which it might be employed. Existing technical limitations and future developments are discussed. It is concluded that the future of EIT as a clinical diagnostic tool is likely to lie in the area of functional monitoring, where the capability of performing image-guided localized electrical impedance measurements with high acquisition speed, good sensitivity and no hazard can be exploited.

Body Composition↗

Electrical impedance tomography; the construction and application to physiological measurement of electrical impedance images.

Electrical impedance tomography enables images of tissue resistivity to be produced from measurements made via an array of surface electrodes. Using the technique of Applied Potential Tomography (APT) an array of 16 electrodes placed around the trunk has been used to image gastric, respiratory and cardiac related events. Some of the advantages and disadvantages of the technique are considered and the possibility of improvement discussed. Some cardiac gated images are presented which show the movement of blood on systole so allowing cardiac output and lung perfusion to be displayed.

Algorithms↗

The use of magnetic resonance imaging data and the inclusion of anisotropic regions in electrical impedance tomography.

Electrical Impedance Tomography (EIT) involves determining the electrical conductivity inside a biological body, given electrical impedance measurements on the surface of the body. This paper will discuss the use of Magnetic Resonance Imaging (MRI) data and the inclusion of anisotropic regions in EIT algorithms to reconstruct a more accurate conductivity profile for a canine torso. MRI data is used to determine the boundaries between regions of different conductivities with greater precision than is presently available using EIT alone. The inclusion of anisotropic regions allows better modeling of the muscle regions (e.g. skeletal muscle) which exhibit a greater conductivity in the direction parallel to the muscle fiber.

Algorithms↗

A real-time electrical impedance tomograph.

Electrical properties of tissues in the human body can be imaged using a technology known as Electrical Impedance Tomography. In this modality, sinusoidal electrical currents are applied to the body using electrodes attached to the skin, and voltages that are developed on the electrodes are measured. Using these data, a reconstruction algorithm computes the conductivity and permittivity distributions within the body. This paper describes the reconstruction algorithm, image display algorithm, and hardware of a real-time Electrical Impedance Tomograph known as the Real-Time Imaging System. The reconstruction algorithm, executed by a commercially available coprocessor board that resides in a 386-based personal computer, is a modification of the Newton's One Step Error Reconstructor (NOSER) that minimizes algorithm execution time by precomputing many quantities. The image display algorithm, also executed by the coprocessor board, maps the output of the reconstruction algorithm into an image which is displayed using a video graphics board. The architecture of the system and execution times of algorithms implemented by the system are discussed. Using the continuous data acquisition mode of the Real-Time Imaging System, data from the thorax of a normal human subject were collected. Admittivity changes in the chest, as a result of respiration and the cardiac cycle, are presented. Data that were collected from the leg of a normal subject are shown which demonstrate capabilities of the triggered data acquisition mode of the system, allowing data acquisition synchronization with an electrocardiogram.

Algorithms↗

Determinants of pulmonary perfusion measured by electrical impedance tomography.

Electrical impedance tomography (EIT) is a non-invasive imaging technique for detecting blood volume changes that can visualize pulmonary perfusion. The two studies reported here tested the hypothesis that the size of the pulmonary microvascular bed, rather than stroke volume (SV), determines the EIT signal. In the first study, the impedance changes relating to the maximal pulmonary pulsatile blood volume during systole (Delta Z(sys)) were measured in ten healthy subjects, ten patients diagnosed with chronic obstructive pulmonary disease, who were considered to have a reduced pulmonary vascular bed, and ten heart failure patients with an assumed low cardiac output but with a normal lung parenchyma. Mean Delta Z(sys) (SD) in these groups was 261 (34)x10(-5), 196 (39)x10(-5) ( P<0.001) and 233 (61)x10(-5) arbitrary units (AU) (P=NS), respectively. In the second study, including seven healthy volunteers, Delta Z(sys) was measured at rest and during exercise on a recumbent bicycle while SV was measured by means of magnetic resonance imaging. The Delta Z(sys) at rest was 352 (53)x10(-5 ) and 345 (112)x10(-5 )AU during exercise (P=NS), whereas SV increased from 83 (21) to 105 (34) ml (P<0.05). The EIT signal likely reflects the size of the pulmonary microvascular bed, since neither a low cardiac output nor a change in SV of the heart appear to influence EIT.

Aged↗

Pulmonary perfusion measured by means of electrical impedance tomography.

Electrical impedance tomography (EIT) is a recent imaging technique based on electrical impedance, offering the possibility of measuring pulmonary perfusion. In the present study the influence of several pulmonary haemodynamical parameters on the EIT signal were investigated. First, the influence on the systolic wave of the EIT signal (delta Zsys) of stroke volume, large pulmonary artery distensibility (both assessed by means of MRI) and the extent of the pulmonary peripheral vascular bed in 11 emphysematous patients (reduced peripheral vascular bed) and 9 controls (normal peripheral vascular bed) was investigated. Second, the influence of hypoxic pulmonary vasoconstriction on delta Zsys was examined in 14 healthy subjects. Finally, the origin of the diastolic wave was examined in three patients with atrioventricular dissociation. Multiple regression analysis showed that delta Zsys was only dependent on the variable emphysema (p < 0.02), but not dependent on stroke volume (p < 0.3) or pulmonary artery distensibility (p > 0.9). The mean value of delta Zsys for emphysematous patients (131 +/- 32 arbitrary units (AU)) was significantly lower (p < 0.001) than in the control group (200 +/- 39). In the group of healthy subjects delta Zsys decreased significantly (p < 0.001) during hypoxia (193 +/- 38 AU) compared with rest measurements (260 +/- 62 AU). The absence of the diastolic wave in the cardiological patients suggests the influence of reverse venous blood flow on the EIT signal. It is concluded that volume changes in the small pulmonary vessels contribute significantly to the EIT signal. Moreover, the hypoxia induced decrease in delta Zsys indicates the potential of EIT for measuring pulmonary vascular responses to external stimuli.

Aged↗

Effect of cooling and re-warming on cerebral and whole body electrical impedance.

Cerebral electrical impedance is useful for the detection of cerebral edema following hypoxia in newborn infants. Thus it may be useful for determining neurological outcome or monitoring treatment. Hypothermia is a promising new therapy currently undergoing trials, but will alter impedance measurements. This study aimed to define the relationship between temperature and both cerebral and whole body electrical impedance, and to derive correction factors for adjustment of impedance measurements during hypothermia. In eight anaesthetized 1-2 day old piglets rectal, tympanic and scalp temperatures were monitored continuously. Following baseline readings at a rectal temperature of 39 degrees C, piglets were cooled to 32 degrees C. Four piglets were re-warmed. Cerebral and whole body impedance were measured at each 0.5 degrees C as rectal temperature decreased. There was a strong linear relationship between both cerebral and whole body impedance and each of the temperatures measured. There was no difference in the relationship between impedance and rectal, tympanic or scalp temperatures. The relationship for impedance and rectal temperature was the same during cooling and re-warming. Using the correction factors derived it will be possible to accurately monitor cerebral and whole body fluid distribution during hypothermic treatment.

Animals↗

Real-time extraction of tissue impedance model parameters for electrical impedance spectrometer.

This paper presents a new algorithm for real-time extraction of tissue electrical impedance model parameters from in vivo electrical impedance spectroscopic measurements. This algorithm was developed as a part of a system for muscle tissue ischemia measurements using electrical impedance spectroscopy. An iterative least square fitting method, biased with a priori knowledge of the impedance model was developed. It simultaneously uses both the real and imaginary impedance spectra to calculate tissue parameters R0, R infinity, alpha and tau. The algorithm was tested with simulated data, and during real-time in vivo ischemia experiments. Experimental results were achieved with standard deviations of sigma R0 = 0.80%, sigma R infinity = 0.84%, sigma alpha = 0.72%, and sigma tau = 1.26%. On a Pentium II based PC, the algorithm converges to within 0.1% of the results in 17 ms. The results show that the algorithm possesses excellent parameter extraction capabilities, repeatability, speed and noise rejection.

Algorithms↗

Classification of breast tissue by electrical impedance spectroscopy.

Electrical impedance spectroscopy is a minimally invasive technique that has clear advantages for living tissue characterisation owing to its low cost and ease of use. The present paper describes how this technique can be applied to breast tissue classification and breast cancer detection. Statistical analysis is used to derive a set of rules based on features extracted from the graphical representation of electrical impedance spectra. These rules are used hierarchically to discriminate several classes of breast tissue. Results of statistical classification obtained from a data set of 106 cases representing six classes of excised breast tissue show an overall classification efficiency of approximately 92% with carcinoma discrimination > 86%.

Breast Neoplasms↗

Characterization of three-dimensional tissue cultures using electrical impedance spectroscopy.

Electrical impedance spectroscopy was used to characterize the cell environment of multilayered cell cultures (MCCs), a culture system in which cells are grown on a permeable support membrane to form a thick disc of cells with tumor-like properties. Cultures were grown using SiHa tumor cells as well as V79 wild-type cells and V79/DOX cells cultivated to exhibit multidrug resistance. Electrical impedance measurements were made on MCCs over a frequency range of 0. 1 kHz to 1 MHz. Data analysis using a simple electrical model for the cell environment yielded estimates for parameters related to the intra- and extracellular resistance and net membrane capacitance, which were then related to MCC thickness. The extracellular fraction and tortuosity of the MCCs were determined in separate experiments where the rate of diffusion and the equilibrium level of C14-inulin, which does not penetrate the cell membrane, was measured within MCCs. Impedance measurements predicted the barrier to diffusion posed by the extracellular space of MCCs to be roughly two times greater than that inferred from the C14-inulin experiments. However, the relative ranking of the three cell types used to grow MCCs was similar for the two methods. Results indicate that impedance spectroscopy is well suited for use in characterizing the MCC cell environment, offering a fast, nondestructive method for monitoring cell culture growth and integrity.

Animals↗