Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Denture Repair”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Cyanoacrylate home denture repair: the problem and a solution.

Patients often attempt to repair denture fractures at home by using cyanoacrylate. Cyanoacrylate is difficult to remove and may prevent the fractured sections from being reassembled properly. This method permits aligning the fractured sections in the mouth before repairing the denture.

Acrylic Resins↗

Fracture force, deflection at fracture, and toughness of repaired denture resin subjected to microwave polymerization or reinforced with wire or glass fiber.

STATEMENT OF PROBLEM: The ultimate goal of denture repair is to restore the denture's original strength and avoid further fracture. The best materials and methods for repair have not been conclusively determined. PURPOSE: This study investigated the fracture force, deflection at fracture, and toughness of a heat-polymerized denture base material repaired with heat-polymerized resin, autopolymerized resin alone, or autopolymerized resin with glass fiber or wire reinforcement. MATERIAL AND METHODS: Eight groups were evaluated: 6 with autopolymerized resin repairs, 1 with heat-polymerized resin repairs, and a control group of intact specimens. The 6 autopolymerized resin groups included 1 group with no reinforcement, 1 treated with microwave irradiation after polymerization, 2 with monolayer or multilayer glass fiber reinforcement, and 2 with round or braided wire reinforcement. Each group consisted of 12 specimens. The experimental specimens were cut, and a 3-mm butt joint gap was repaired as indicated by the group assignment. A 3-point bending test was used to determine the fracture force, deflection at fracture, and toughness of the specimens. The data were analyzed with 1-way analysis of variance and the Tukey post-hoc test (alpha=.05). RESULTS: The fracture force (28.4 to 73.4 N), deflection (1.6 to 3.8 mm), and toughness (0.02 to 0.13 J) values for all repaired groups were significantly lower than those for the control group (82.79 N, 4.4 mm, and 0.16 J, respectively), with one exception: the mean fracture force of specimens reinforced with round wire (102.9 N). Failure mode was always adhesive, meaning that fracture occurred between the denture base and repair resin. CONCLUSION: Among the repair treatments tested, the most effective was microwave-irradiated, autopolymerized resin reinforced with round wire or monolayer glass fiber ribbon.

Analysis of Variance↗

The effect of chemical surface treatments of different denture base resins on the shear bond strength of denture repair.

STATEMENT OF PROBLEM: Fracture of a repaired denture base often occurs at the junction of the base and repair materials rather than within these materials. PURPOSE: The purpose of the study was to evaluate the shear bond strengths of 4 denture base acrylic resins following the use of 3 chemical solvents and to examine treated acrylic resin surfaces under a field emission scanning electron microscope (SEM). MATERIAL AND METHODS: Forty discs (15 mm in diameter and 3 mm thick) were fabricated for each denture base material (a conventionally molded, heat-polymerized [Meliodent, M], an injection-molded, heat-polymerized [SR-Ivocap, I], and a microwave-polymerized [Acron MC, A]) repaired with an autopolymerizing acrylic resin (Meliodent), for a total of 120 specimens, processed according to manufacturers' instructions, embedded in acrylic resin blocks, and divided into 4 groups of 10. One of the groups served as control and had no surface treatment. In the 3 experimental groups, specimen surfaces were treated with chemical etchants by immersion in acetone (ac) for 30 seconds, in methylene chloride (mc) for 30 seconds, or in MMA (mo) for 180 seconds, respectively. Then autopolymerizing acrylic resin (Meliodent) was placed on the treated surfaces using a brass ring (6 mm in diameter and 2 mm in height) to confine the material to a standardized dimension. After 24 hours of storage at 37 degrees C, the shear bond strength (MPa) of the specimens was measured in a universal testing machine. A 2-way analysis of variance and the Tukey HSD test were performed to identify significant differences (alpha=.05). The nature of the failure was noted as adhesive, cohesive, or mixed. The effect of the chemical treatments on the surface of base resins was examined under an SEM. RESULTS: Chemical treatments increased the bond strength of repair material significantly. Significant differences were found between the control and experimental groups (P<.001). In the control group, M showed the highest (16.7 MPa) bond strength, and A showed the lowest (9.4 MPa). No significant differences were detected between M (18.9 MPa) and A (19.9 MPa) with acetone treatment, or between M (19.3 MPa) and A (20.3 MPa) with methylene chloride treatment. The SEM observations showed that application of chemical etchants produced smoother surfaces than controls. CONCLUSION: Chemical treatment prior to denture base repair showed significant improvement on the bond strength of the base materials. Although the microwave-polymerized acrylic resin, A, showed the lowest shear bond strength compared to the control groups, the highest percentage increase was obtained with A after chemical treatments.

Acetone↗

Shear bond strength of microwaveable acrylic resin for denture repair.

Microwaveable acrylic denture resins are believed to provide an effective means of repairing fractured dentures. This in vitro investigation compared the bond strength of a microwaveable acrylic resin as a denture repair material to two established auto-polymerized resins. Fifty-one specimens were made using Lucitone 199 as a simulated denture base, and were then divided into three groups of 17 samples each. Each test group was bonded with the following acrylic resins: Acron Mc, Rapid Repair and Palapress. A shear bond strength test was carried out 24 h after the samples were bonded. Fracture analysis showed that bond failure was adhesive for all groups. Shear bond values showed a statistically significant difference at P < 0.05 level between Acron Mc and Rapid Repair; Palapress and Rapid Repair, and indicated that Acron Mc and Palapress were superior to Rapid Repair as a repair material. However, there was no statistical difference found between Acron Mc and Palapress. Microwaveable acrylic resins produce repaired junctions of adequate strength.

Acrylic Resins↗

Microwave pressure chamber processing of a denture repair polymer.

Most denture base repairs are made using a chemically activated acrylic resin polymer for reasons of cost and expediency. Heat-activated polymers are not typically used because they require a custom split cast gypsum mold, longer polymerization time, and higher laboratory fees. Repairs made using a chemically activated polymer compared with a heat-activated polymer generally have reduced transverse strength, poorer color stability, increased water sorption, and weak bond strength to existing acrylic resin. A method of utilizing a microwave polymer in a commercially available microwave flask is described. This technique allows denture base repairs to be made with a heat-activated polymer in a manner similar to that of chemically activated repairs.

Acrylic Resins↗

An evaluation of bond strengths of denture repair resins by a torsional method.

Chemical cure resin materials are generally used in the repair of dentures. Different repair resins used may yield different results. The bond strength of three autopolymerizing resins were evaluated using a torsional test method. The results showed that Palapress and Caulk resins had a higher repair strength than Rapid Repair resin.

Acrylic Resins↗

Effect of surface treatments on the repair strength of a light-activated denture repair resin using censored data.

OBJECTIVES: The aim of this study was to evaluate the effect of three different chemical surface modifications on the bond strength of light-activated denture repair resin (Triad, Dentsply International) to a heat-cured resin (Lucitone, Dentsply International). METHODS: Transverse flexure test specimens were made, with surface treatment of 1) Triad bonding agent, 2) unreacted Lucitone monomer, and 3) a 1:1 mixture of methylene chloride and monomer, using two different application times (2 and 4 min). For all except one group, 18 specimens were made. The controls were solid single composition bars, 18 for each material. The elastic modulus in transverse flexure was measured for each material. The statistical analysis employed the Weibull distribution. Fracture strength values were obtained in a three-point flexure test. RESULTS: It was noted that many fractures occurred away from the interface and the center member of the test fixture. For those fractures, the observed fracture strength is a censored value of the fracture strength. Algorithms for the statistical treatment of censored data were used to get the maximum likelihood estimates of the fracture strength. A mechanical model showed that under three-point bending of a beam of two joined materials, fractures will occur in the part with the higher elastic modulus. This finding is indeed observed in the data. The 4 min monomer treatment showed the highest estimate of the bond strength (187.8 MPa). SIGNIFICANCE: Censored data can be used to obtain fracture strength estimates, and the censoring indicates that the bond strength may exceed the strength of the bulk material.

Acrylic Resins↗

Denture repairs in different regions of Croatia in relation to prosthodontic teams.

The purpose of this paper is to evaluate the incidence of denture repairs in different districts of Croatia through the year of 2002. and to analyse the percentage of different repairs (relinings, simple repairs up to 2 elements and complicated repairs-more than 2 elements) in relation to prosthodontic teams. Data on the number of dentures, and the number and types of denture repairs delivered in the Croatian regions of Zagreb, Rijeka, Split and Karlovac were obtained from the Croatian Institute for Health Insurance for the whole of the year 2002. Information of the number of prosthodontic teams operating in those regions was also obtained. Proportionally more denture repairs were carried out in Karlovac (18%) than Split (5%). The smallest percantage of dentures that required relining was registered in Split and the highest in Rijeka (chi2 = 36.7, p < 0.01). The smallest percentage of simple repairs was registered in Rijeka and the highest in Split (chi2 = 24.3, p < 0.01). The smallest percentage of complicated repairs was registered in Split and the highest in Karlovac. In each region the proportion of denture repairs and types of repairs were correlated with a number of prosthodontic teams in that region. Karlovac had the smallest percentage of specialistic prosthodontic teams and the highest rate of denture repairs.

Croatia↗

Efficacy of conventional and experimental techniques for denture repair.

This study investigated the efficacy of one experimental and three conventional techniques for denture repair. Forty maxillary dentures were constructed in dental stone casts duplicated from an edentulous copper-aluminium maxillary master cast. Two groups of 20 dentures each were prepared with Lucitone 199 (water-bath, 8 h/74 degrees C) or Acron MC (microwave, 3 min/500 W) denture base materials processed in gypsum moulds. The 40 dentures were all separated sagittally in the middle. After that, five dentures of each denture base material were repaired with one of the four following techniques: L (Lucitone 199, water-bath, 8 h/74 degrees C, gypsum mould), A (Acron MC, microwave, 3 min/500 W, gypsum mould), AR (Acron MC/R, autopolymerized, 60 psi/45 degrees C/15 min) and the experimental technique AS (Acron MC, 1 min/500 W + 1 min/0 W + 1 min/500 W, hard silicone mould). The parameters denture accuracy (DA), horizontal (HC) and vertical changes (VC) of the occlusal plane measured the efficacy of the repair techniques. The DA was determined by weighing a film of silicone impression material set in contact to the tissue surface of the denture seated on the metallic master die. For HC, cross-arch measurements were made among reference marks drilled on the teeth 11, 21, 16 and 26. The VC was obtained by calculating the relative differences in height between similar teeth of each semi-arch (pairs 13-23, 14-24, 15-25 e 16-26). For DA, HC and VC, the percentage differences between the percentage means obtained before and after repair were calculated and grouped for comparisons. Analysis of variance (SuperANOVA) and means compared by Tukey-Kramer intervals (0.05) revealed that AR repair had the best percentage difference value for DA [0.5% (P < 0.05)], while the others were not statistically different [L = 27.2%, A = 28.9%, AS = 21.2% (P > 0.05)]. For HC, there was a statistical difference (P < 0.05) between AR and the other techniques for the tooth pairs, 16-26, 11-26 and 21-16; repairs with AR and AS differed for the 11-21 pair, while those with A and AS techniques differed for the 16-26 pair (P < 0.05). The VC differences were not detected between repair methods (P > 0.05). Denture accuracy was not affected by the interaction of base material-repair technique; repair with AR technique gave the best adaptation; the interaction of base material-repair technique did not affect HC; HC was affected by the repair technique.

Acrylic Resins↗

Degradation of repaired denture base materials in simulated oral fluid.

This in vitro study evaluates the degradation of repaired denture bases upon immersion in a simulated oral fluid. Denture base materials (Luciton 199), after being repaired by Repair Material and Triad, using three different joint surface designs (butt, round and 45 degrees bevel), were immersed onto 99.5 vol.% ethanol/water solution (with similar solubility parameter) for various amounts of time (0-72 h). The flexural loads of the six combination of groups were measured by the three-point bending tests using a universal testing machine. Acoustic emission (AE) during sample fracturing were processed using the MISTRA 2001 system. The fracture pattern and surface details of the interface were examined with a scanning electronic microscope (SEM). Data were analysed using three-way ANOVA and Tukey LSD tests. SEM micrographs of the fracture interface were used to differentiate the fracture mode. The flexural loads (2.72 +/- 0.51 Kgf) of the round joint specimens were significantly higher (P< 0.05) than those (butt: 1.66 +/- 0.38 Kgf, 45 degrees bevel: 1.93 +/- 0.41 Kgf) of the other two designs. This corresponds to the microscopic examination in which more cohesive failure mode was found for the round joint group after storage. The flexural loads (2.54 +/- 0.39 Kgf) of the specimens repaired with Triad were significantly higher (P < 0.05) than those (1.59 +/- 0.40 Kgf) of specimens repaired with Repair Material. Significant progressive reduction of the flexural load and/or AE signals of the specimens was noted in proportion to the length of time of the immersion in the simulated oral fluid. Mechanical strength of a denture base repaired with a round joint design and light-cured material is significantly higher after immersion in simulated oral fluid.

Acoustics↗

Urgent denture repair in a medically compromised patient.

Dental practices will see an increasing number of older patients as our population ages over the next decade. The following article describes a denture repair in a patient with Parkinson's disease. The patient and his caregiver were unable to make multiple trips to the clinic for treatment. The type of repair described in this article minimized the amount of expense and time required to repair the denture.

Adult↗

Basic studies on visible light-cured resin as a denture base. Part 17. Transverse and tensile strengths of repaired denture base resin using a trial repair resin.

Trial production of a visible light-cured repair resin (powder/liquid type, TPL) as a denture base resin was carried out using cyclophosphazene monomer, and then the transverse and tensile strengths of the repaired specimens were examined. As a control, Triad Gel (TRI) was used. In the transverse strength test, TPL showed values of 507-470 kgf/cm2, which were about double those of TRI. As for tensile strength, TPL showed values of 329-268 kgf/cm2, and higher values were obtained in comparison with TRI, especially after 30 days of water immersion, when the values were doubled. The durability of TPL was favorable in comparison with TRI.

Composite Resins↗

The pontic-splinted procedure for tooth and denture base additions in denture repair.

Various methods for adding teeth to existing dentures have been used clinically. Although a direct, single-tooth addition method saves time, it often is difficult to achieve an esthetic appearance when adding several missing anterior teeth with this technique. Indirectly adding teeth may achieve a better esthetic result, but this method is time-consuming. This article describes the pontic-splinted procedure, an indirect method for replacing several anterior teeth and part of the denture base that can save time and, at the same time, help the clinician achieve acceptable esthetics.

Acrylic Resins↗

Bending strength of intact and repaired denture base resins.

Results of bending strength and deflection at fracture of intact and repaired denture base resin specimens were obtained. Both heat-cured and cold-cured resins of two different products were used. After storage in distilled water at 37 degrees C for 1 month, some of the intact heat-cured specimens were dried in air at 21 +/- 1 degree C for 24 h before testing. This induced a lowering of the bending strength. There was no difference in strength between the two products. However, the intact heat-cured specimens of SR 3/60 showed higher results of deflection at fracture than Vertex. Repaired specimens had a bending strength between 42.9% and 61.2% compared with the intact heat-cured specimens tested immediately after storage in water. The repair performed with the low-viscosity self-cured resin resulted in higher bending strength values than when using repair material with the higher initial viscosity. Drying the broken heat-cured specimens for 24 h at 21 +/- 1 degree C before the repair and painting with monomer liquid on the fractured surfaces of the heat-cured resin was without effect on the bending strength of the repaired specimens.

Acrylic Resins↗

Clinical survey of acrylic resin removable denture repairs with glass-fiber reinforcement.

PURPOSE: The aim of this study was to evaluate clinical usefulness and durability of continuous glass-fiber reinforcement in repair of acrylic resin removable dentures. MATERIALS AND METHODS: Fractured removable dentures without reinforcement, with conventional metal-wire reinforcement, or with mesh reinforcement were collected from two dental schools in Finland. The total number of dentures was 51 and the number of patients was 48. During the repair, the dentures were reinforced with a polymer-preimpregnated E-glass fiber at the region of the fracture. The fibers were used as partial fiber reinforcement, i.e., only the weakest part of the denture was reinforced. Follow-up time varied from 4 months to 4.1 years. After the follow-up period, possible fractures and discoloring were visually inspected. Possible irritation of oral mucosa by glass fibers and the general shape of the denture were also evaluated. RESULTS: In 88% of the cases, there was no need for adjustment at the region of partial fiber reinforcement, and the clinical condition of the dentures was good. Glass fibers did not irritate the oral mucosa. In the case of refracture or hairline fracture, positioning of the partial fiber reinforcement was incorrect or the reinforcement had been used incorrectly (the wetting of the reinforcement with denture base resin was inadequate). CONCLUSION: Polymer-preimpregnated partial fiber reinforcement seems to be useful in eliminating fractures of acrylic resin removable dentures. However, this study emphasizes the importance of correct positioning and accurate laboratory technique when partial fiber reinforcement is used.

Acrylic Resins↗

Evaluation of shear bond strength of microwaveable acrylic resins in denture repair: a comparative study.

OBJECTIVE: Acrylic denture base fracture is a common mode of failure. Heat-cured, auto-polymerized, visible light-cured, and microwaveable acrylic resins have been used as repair materials. The aim of this study was to evaluate the shear bond strength of two microwaveable resins (Acron MC and Justi) and one auto-polymerizing acrylic resin (ProBase Cold) as denture repair materials as opposed to a heat-cured one using the non-flasking procedure after thermocycling and photoaging. MATERIAL AND METHODS: Ninety cylindrical specimens were made using the Vertex Rapid Simplified heat-cured acrylic resin. Each repair acrylic resin was poured on the specimen's surface using a cylindrical rubber mold with an internal diameter of 8.5 mm. Thirty specimens for each repair material were made. The control group consisted of 10 specimens from each group which were stored in water for 24 h at 37 degrees C; another 10 specimens from each group were subjected to a thermocycling procedure (5-55 degrees C for 1,000 cycles), while the remaining 10 specimens were subjected to a photoaging procedure. Shear bond strength was measured on a universal testing machine and mode of bond failure was examined under a stereomicroscope. Two-way ANOVA and the Bonferroni post hoc test were performed to identify statistical differences at alpha = 0.05. RESULTS: Justi's shear bond values were significantly inferior to those of ProBase Cold (p <0.05) and Acron MC (p <0.05). ProBase Cold and Acron MC acrylic resins exhibited similar values (p >0.05) of shear bond strength. Thermocycling and photoaging did not affect the shear bond values of any of the materials under investigation (p >0.05). CONCLUSIONS: ProBase Cold and Acron MC exhibited similar shear bond values. Justi repair material exhibited inferior bond strength compared with that of ProBase Cold and Acron MC. Aging procedures did not affect the bonding properties of any of the repair materials.

Acrylic Resins↗