Search PubMedSearch

SEARCH · Search PubMed

Results for “Dental Prosthesis, Implant-Supported”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,037 recordsLinked to original sources

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG® (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 ± 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

Influence of Concave Versus Convex Emergence Profiles on Midfacial Mucosal Stability-A Systematic Review With Meta-Analysis.

OBJECTIVES: To systematically evaluate the influence of concave versus convex emergence profiles on midfacial mucosal stability in partially edentulous patients restored with implant-supported single restorations. MATERIALS AND METHODS: A systematic review and meta-analysis of randomized controlled trials (RCTs) was conducted and registered in PROSPERO (CRD420251139042). An electronic search in MEDLINE (PubMed) and Embase was performed up to May 7, 2026. Eligible studies included RCTs comparing concave (test group) and convex (control group) transmucosal prosthetic designs and reporting midfacial mucosal level changes (mm). Data extraction and risk of bias assessment (RoB 2) were performed independently. A random-effects meta-analysis was conducted using weighted mean differences (MDs) and 95% confidence intervals (CIs). Heterogeneity was assessed using the I2 statistic and sensitivity analyses were performed to evaluate the robustness of the findings. RESULTS: Four RCTs including 144 implants with a 12-month follow-up were included. Of these, 128 implants contributed to the quantitative synthesis, with 66 implants allocated to the concave/modified emergence profile group and 62 implants allocated to the convex/non-concave emergence profile group. The pooled analysis demonstrated a mean difference of -0.31 mm (95% CI -0.63 to 0.02; p = 0.064), indicating a trend toward greater midfacial mucosal recession with convex emergence profiles compared with concave designs. Between-study heterogeneity was low to moderate (I2 = 28%), suggesting consistent findings across studies. Sensitivity analyses confirmed the direction of the effect, with pooled estimates ranging from -0.12 to -0.43 mm. Exclusion of one study resulted in a statistically significant difference favoring concave emergence profiles (-0.43 mm; 95% CI -0.70 to -0.16; p = 0.002). CONCLUSIONS: Convex emergence profiles are associated with a tendency toward increased midfacial mucosal recession. Concave profiles are preferable to support peri-implant soft-tissue stability. CLINICAL RELEVANCE: Emergence profile design should be considered an integral component of prosthetic and surgical planning. The use of concave transmucosal contours during provisionalization and definitive restoration may contribute to improved peri-implant soft tissue stability and enhanced esthetic outcomes.

Humans

Comparison of short-term clinical outcomes and patient satisfaction between intraoral scanning and conventional impressions for complete-arch implant prostheses: a pilot RCT.

OBJECTIVE: To compare framework passive fit, subjective evaluations, and short-term clinical outcomes between conventional impressions (CI) and intraoral scanning (IOS) for complete-arch implant-supported fixed dental prostheses (CIFDPs). METHODS: In this randomized controlled trial, 22 patients were allocated to the CI or IOS groups. All participants received a definitive one-piece CIFDP. The primary outcome was framework passive fit, assessed using the Vision and Tactile Score (V&T score), which included framework lift-off, the single-screw test, the full-screw test, smoothness of screw insertion, and radiographic gap assessment. Secondary outcomes included operator evaluation, patient satisfaction using a visual analog scale (VAS), early implant survival, marginal bone loss (MBL), modified Plaque Index (mPII), and complications at the 6-month follow-up. RESULTS: Twenty-two patients were enrolled (CI: n = 11; IOS: n = 11), and one patient in the CI group was lost to follow-up. No statistically significant difference in the V&T score was observed between the CI and IOS groups (4.66 &#xb1; 0.17 vs. 4.65 &#xb1; 0.28; P = 0.93). The operator reported greater nervousness during the CI procedure than during IOS (21.82 &#xb1; 15.69 vs. 8.64 &#xb1; 7.47; P < 0.05). Patients in the CI group reported significantly greater discomfort, including nausea and anxiety, than those in the IOS group (P < 0.05). At the 6-month follow-up, the early implant survival rate was 100% in both groups. No significant differences were found between the groups in MBL (0.09 &#xb1; 0.09 vs. 0.06 &#xb1; 0.10 mm; P = 0.43) or mPII (0.10 &#xb1; 0.12 vs. 0.10 &#xb1; 0.28; P = 0.99). CONCLUSION: IOS and CI achieved comparable short-term clinical outcomes in patients who met the predefined inclusion criteria, including controlled implant number, spacing, and angulation. IOS provided a more favorable experience for both operators and patients. CLINICAL SIGNIFICANCE: In complete-arch implant restorations, intraoral scanning may provide clinical outcomes comparable to those of conventional impressions while improving patient comfort.

Humans

Indications, Techniques and Complications Associated With Pterygoid Implants: A Systematic Review and Meta-Analysis.

BACKGROUND AND OBJECTIVES: Pterygoid implants represent a graftless option for rehabilitation of patients with posterior maxillary atrophy, engaging the dense cortical bone of the pterygomaxillary complex. Despite clinical growth, a comprehensive synthesis of indications, surgical techniques, and complications is lacking. This review evaluated the prevalence of complications, implant survival rates, and marginal bone loss (MBL) associated with pterygoid implant placement. METHODS: The reporting of this review follows PRISMA 2020 guidelines. Six electronic databases (PubMed, Ovid, Scopus, WoS, CENTRAL, and Dentistry & Oral Sciences Source) were searched from 1 January 2020 to 31 December 2025. Included criteria comprised randomized and non-randomized clinical studies reporting outcomes of pterygoid implants (&#x2265;&#x2009;13&#x2009;mm) in adult patients with posterior maxillary atrophy (minimum 10 implants). Risk of bias was assessed using JBI critical appraisal checklists. Proportions were pooled using the Freeman-Tukey double arcsine transformation under a random-effects model. Certainty of evidence was assessed using GRADE. RESULTS: Seventeen studies reporting 846 patients and 1915 pterygoid implants were included. The pooled survival rate was 97.9% (95% CI: 97.1%-98.6%; I2&#x2009;=&#x2009;0%; 14 studies) and the overall failure rate was 2.1% (95% CI: 1.4%-3.0%). Early failure rate was 0.9% (95% CI: 0.0%-3.0%; I2&#x2009;=&#x2009;59.5%). Late failure and MBL were summarized narratively. Certainty of evidence was low to very low. CONCLUSIONS: Pterygoid implants demonstrate excellent survival (97.9%) and low failure rates (2.1%), primarily early, supporting their reliability as a graftless solution for posterior maxillary atrophy. Complications appear infrequent though heterogeneously reported. Low evidence certainty necessitates prospective studies with standardized outcome reporting.

Humans

Marginal fit and five-year outcomes of posterior monolithic zirconia restorations: A randomized paired and observational clinical study.

OBJECTIVES: The aim of this study was to evaluate the marginal fit and five-year clinical performance of posterior 5 mol% yttria-partially stabilized zirconia restorations. A randomized paired comparison with lithium disilicate crowns was performed for marginal fit. METHODS: A total of 65 posterior restorations were placed in 38 patients, including 32 zirconia crowns, 17 lithium disilicate crowns, and 16 zirconia partial coverage restorations. In the randomized paired comparison, 17 patients received one lithium disilicate crown and one zirconia crown. Additional zirconia crowns (n=15) and zirconia partial coverage restorations (n=16) were included in a prospective observational cohort. The primary outcome was marginal fit within the randomized cohort. Marginal and internal fit were assessed using the replica technique. Marginal and internal gap values were compared using the Wilcoxon signed-rank test; clinical outcomes were analyzed descriptively, and Kaplan-Meier estimates were calculated for survival and complication-free survival. Clinical performance was assessed using CDA criteria, periodontal parameters, complication recording, and patient-reported outcomes. Clinical examinations were performed at baseline and at 12, 24, 36, 48, and 60 months. RESULTS: Mean marginal gap values at the crown margin were 46 &#xb1;33 &#xb5;m for lithium disilicate crowns and 50 &#xb1;32 &#xb5;m for zirconia crowns (p>0.05). No restoration required replacement, resulting in 100% restoration survival after a median follow-up of 60 months (range: 57-64 months). Most complications were biological or functional, including endodontic, periodontal, occlusal, and proximal-contact-related events. One zirconia partial coverage restoration exhibited a small ceramic fracture managed by polishing. The Kaplan-Meier probability of complication-free survival was 76.4% for zirconia crowns, 66.7% for lithium disilicate crowns, and 87.5% for zirconia partial coverage restorations. CONCLUSIONS: In the randomized paired comparison, 5 mol% yttria-partially stabilized zirconia crowns showed marginal gap values similar to lithium disilicate crowns. All restorations remained in situ during the observation period. Lower complication-free survival was mainly related to biological and functional events and should be interpreted separately from restoration survival. CLINICAL SIGNIFICANCE: Clinical evidence for posterior 5 mol% yttria-partially stabilized zirconia restorations remains limited. This study provides mid-term clinical data on crowns and partial coverage restorations. In the randomized full-crown comparison, marginal fit was similar to that of lithium disilicate crowns, supporting the clinical consideration of monolithic zirconia restorations for posterior teeth.

Humans

Influence of endodontic access on the fracture resistance, retention and microleakage of full-coverage restorations in vitro: A systematic review and meta-analysis.

BACKGROUND: Endodontic access through retained full-coverage restorations (FCRs) is a preferred option for patients because of its high cost-effectiveness. However, the clinical performance of FCRs after repaired access cavity remains insufficiently characterized. This systematic review investigates the effects of endodontic access cavity preparation through retained FCRs on fracture resistance, retention, and microleakage based on in vitro studies. METHODS: A comprehensive search was performed in PubMed, Web of Science, and Scopus databases. Studies investigating the influence of endodontic access on the fracture resistance, retention, and microleakage of FCRs were included. Two independent reviewers conducted study selection, data extraction, and risk-of-bias assessment using the QUIN tool. Meta-analysis was employed to estimate fracture resistance and retention, with sensitivity analysis and subgroup evaluation also performed. Microleakage was summarized qualitatively. RESULTS: Twentythree studies were included: fracture resistance (n = 15), retention (n = 5), and microleakage (n = 3). Endodontic access significantly reduced fracture resistance for zirconia (p = 0.0002) and lithium disilicate (LD) restorations (p = 0.007), but not for resin-matrix ceramic (RMC) restorations (p = 0.25). Abutment tooth type contributed to heterogeneity within the LD and RMC subgroups. Retention was significantly reduced when access cavities were left unrepaired (p = 0.03), whereas appropriate repair protocols restored or enhanced retention relative to baseline. Accelerated aging increased microleakage in retained FCRs. Surface pretreatments and flowable resin liners tended to reduce microleakage, but findings were inconsistent. CONCLUSIONS: Endodontic access significantly reduces fracture resistance of zirconia and LD FCRs, whereas RMC restorations show no significant change. Appropriate repair protocols can restore or improve retention, potentially exceeding original values. Limited evidence suggests that effective sealing is achievable with appropriate materials. However, well-designed and in-vivo researches are needed to provide more detailed clinical guidance. CLINICAL SIGNIFICANCE: When performing endodontic access through retained FCRs, reduced fracture resistance must be carefully considered for zirconia and LD restorations, while RMC restorations may be exempt from this concern. Loss of retention with access can be restored after repair. Surface pretreatment and flowable resin liners help decrease microleakage.

Humans

The use of diode laser and scalpel blade in stage-two dental implant surgery: a comparative study.

OBJECTIVE: The use of lasers in dental implant procedures raises questions regarding the preservation of keratinized tissues and implant outcomes. This study aimed to compare the clinical effects (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing) of diode lasers and scalpels used during stage-two dental implant surgery. METHOD AND MATERIALS: A prospective randomized clinical trial with a 1:1 allocation ratio was conducted. The study included 30 patients, each with a single, fully osseointegrated implant. Patients were categorized into two groups. The study group underwent stage-two implant surgery using a 970-nm diode laser. In the control group, implants were exposed using a conventional surgical blade. A comparison between the diode laser and conventional scalpel groups was made based on clinical outcomes (pain and impression time) and soft tissue healing (keratinization, peri-implant probing, bleeding, and healing). Data were analyzed using a paired t test. RESULTS: Pain intensity significantly decreased from immediate postoperative to 7 days in both scalpel (49.87 &#xb1; 6.78, t = 28.48, df = 14, P .001) and diode laser (7.67 &#xb1; 7.58, t = 3.91, df = 14, P = .002) groups. Immediately after surgery, pain scores were significantly higher in the scalpel group compared with the diode laser group (94.53 &#xb1; 4.45 vs 46.93 &#xb1; 5.85, t = 25.076, df = 26.151, P .001). Although pain decreased in both groups by day 7, the scalpel group continued to exhibit significantly greater pain (44.67 &#xb1; 5.96 vs 39.27 &#xb1; 3.73, t = 2.974, df = 23.513, P = .007). Impression time (P = .231) and gingival keratinized tissue (P = .736) did not differ significantly between the scalpel and diode laser approaches. At week 6, the scalpel group exhibited a significantly higher mean peri-implant bleeding index (2.60 &#xb1; 0.507) compared with the laser group (0.07 &#xb1; 0.258, P .001). However, after 12 weeks, no significant difference was observed (1.58 &#xb1; 0.19 vs 1.55 &#xb1; 0.21, P = .748). Laser surgery produced significantly better early wound healing at all intervals (P .001), while intraoperative bleeding was more common with the scalpel technique than with the diode laser (100.0% vs 66.7%, P = .042). CONCLUSION: Compared with the scalpel method, the diode laser method resulted in a significant reduction in pain intensity, improved wound healing, and less peri-implant bleeding during the stage-two dental implant surgery.

Humans

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Evaluation of intravenous sedation in dental implant surgeries: A prospective cohort study.

PURPOSE: This study aimed to evaluate the impact of intravenous sedation on patient-centered outcomes during implant and bone augmentation surgeries. METHOD: A prospective observational cohort study included 40 patients undergoing placement of &#x2265;3 implants, with or without bone augmentation. Patients underwent surgery under either intravenous sedation (n = 20) or local anesthesia alone (n = 20), according to routine clinical decision-making and patient preference. The sedation group received intravenous sedation with a multimodal regimen comprising remimazolam, dexmedetomidine, alfentanil, and low-dose esketamine, whereas the control group received local anesthesia only. Patient-reported outcome measures, hemodynamic parameters (SBP, DBP, HR, SpO2), postoperative pain (0-10 scale), and OHRQoL (OHIP-14) were recorded from baseline through 7 days post-surgery. RESULTS: Intravenous sedation was associated with significantly lower intraoperative pain (0.5 [IQR: 0&#x223c;2.75] vs. 3.25 &#xb1; 2.40, p = 0.003), anxiety (1 [IQR: 0&#x223c;2.75] vs. 4 [IQR: 3&#x223c;6], p = 0.001), and experienced discomfort (2 [IQR: 1&#x223c;3.75] vs. 4.15 &#xb1; 2.16, p = 0.016), and shortened perceived treatment duration (2.90 &#xb1; 2.34 vs. 5 [IQR: 4&#x223c;5], p = 0.020). Early postoperative pain was lower in the sedation group from Days 1-4 (p = 0.003-0.010). Hemodynamic parameters were more stable under sedation, with lower SBP (116.42 &#xb1; 13.32 vs. 144.11 &#xb1; 17.42 mmHg, p < 0.001), DBP (73.21 &#xb1; 10.28 vs. 82.37 &#xb1; 11.03 mmHg, p = 0.012), and HR (71.00 [IQR: 62.50&#x223c;79.25] vs. 85.00 &#xb1; 10.72 bpm, p = 0.021). OHRQoL scores favored the sedation group in swallowing, diet, malaise, and daily activities, particularly during the first three postoperative days (p=0.006-0.040). CONCLUSION: Intravenous sedation may enhance the patient experience during implant and/or bone augmentation procedures by reducing intraoperative pain and anxiety, improving hemodynamic stability, and promoting better early-postoperative recovery and OHRQoL. These findings suggest that intravenous sedation provides a safe and effective alternative for implant dentistry surgery, particularly for anxious or pain-sensitive individuals.

Humans

Prophylactic Surgical Left Atrial Appendage Closure in Bioprosthetic Aortic Valve Replacement: Short-Term Outcomes of Randomized Controlled LAA-CLOSURE Trial.

BACKGROUND: Surgical closure of the left atrial appendage (LAA) reduces stroke risk in patients with atrial fibrillation (AF) undergoing cardiac surgery. We evaluated the safety and efficacy of prophylactic LAA closure during bioprosthetic surgical aortic valve replacement in patients without prior AF. METHODS: In this investigator-initiated, academic, randomized, open-label, multicenter LAA-CLOSURE (Left Atrial Appendage CLOSURE for the Prevention of Thromboembolisms in Patients Undergoing Aortic Bioprosthesis Surgery) trial, 921 patients without prior AF undergoing bioprosthetic surgical aortic valve replacement with or without concomitant surgery were randomized and 904 patients included in the modified intention-to-treat analysis (prophylactic LAA closure, n=445; or usual care, n=459). Median age was 73&#x2009;years (interquartile range, 69-76), 34.8% were women, and 49% had concomitant coronary artery disease. The primary end point was a composite of cardiovascular death, stroke, or systemic embolism at 30&#x2009;days. RESULTS: The primary end point occurred in 10 of 434 (2.2%) patients in the LAA closure group and 14 of 452 (3.1%) patients in the control group; however, the treatment effect changed direction at &#x2248;7&#x2009;days. In the time-split Cox regression model, hazard ratios were 2.4 (95% CI, 0.62-9.4; P=0.20) between 0 and 7&#x2009;days and 0.29 (95% CI, 0.080-1.0; P=0.056) between 7 and 30&#x2009;days. No closure-related serious complications or differences in bleeding were observed. Postoperative AF occurred in 205 of 445 (46.1%) versus 184 of 459 (40.1%) patients (relative risk, 1.1 [95% CI, 0.99-1.3]; P=0.07), and AF at discharge in 40 of 445 (9.2%) versus 34 of 459 (7.7%) patients (relative risk, 1.2 [95% CI, 0.77-1.8]; P=0.44), in the closure and control groups, respectively. CONCLUSIONS: Prophylactic LAA closure during bioprosthetic surgical aortic valve replacement was safe and did not increase bleeding. REGISTRATION: URL: clinicaltrials.gov; Unique Identifier: NCT02321137.

Aged

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Socket motility assessment of anophthalmic sockets: a systematic review.

PURPOSE: Systematically review and categorize the methods used to assess socket and prosthetic motility in anophthalmic patients following enucleation or evisceration. METHODS: A systematic review was conducted in accordance with PRISMA guidelines. PubMed, Embase, Web of Science, and Scopus were searched from inception through September 2024. Studies reporting qualitative or quantitative assessments of motility in anophthalmic sockets or ocular prostheses were included. Motility assessment methods were categorized as qualitative (descriptive or graded clinical evaluation) or quantitative (numerical measurements in millimeters, degrees, or objective tracking systems). RESULTS: Thirty-five studies encompassing 1,819 patients met inclusion criteria. Nineteen studies used qualitative assessment methods, including subjective observation, graded scales based on cardinal gaze positions, or comparison with the contralateral eye. Sixteen studies employed quantitative techniques, such as the Kestenbaum limbus test, Lister perimeter measurements, conjunctival or limbal markings, photographic image analysis, infrared eye-tracking systems, and magnetic search-coil technology. Considerable heterogeneity was observed in measurement techniques, reporting standards, timing of assessment, and distinction between socket and prosthetic motility. CONCLUSIONS: Substantial variability exists in the methods used to assess motility in anophthalmic sockets, limiting comparability across studies. Establishing standardized, feasible, and reproducible assessment approaches may improve outcome reporting and facilitate meaningful comparisons in future oculoplastic research.

Humans

Physician-Modified Fenestrated Stent-Grafts Planned Using Three-Dimensional Techniques for Complex Aortic Pathology: A Systematic Review and Meta-Analysis.

BACKGROUND: Complex aortic pathology involving the visceral arteries remains a significant therapeutic challenge. Open repair is associated with considerable perioperative risk, particularly in patients with multiple comorbidities, while standard endovascular aneurysm repair (EVAR) is often not feasible because of inadequate proximal sealing zones. Fenestrated and branched endovascular repair (F/BEVAR) represents an established treatment strategy; however, the use of custom-made devices is limited by manufacturing time and availability. Physician-modified stent grafts (PMSGs) have therefore emerged as a pragmatic alternative. Three-dimensional planning techniques have been increasingly used to facilitate accurate graft modification. The aim of this systematic review and meta-analysis was to evaluate the effectiveness and safety of PMSG procedures planned with three-dimensional techniques. Technical success, target vessel patency, early mortality, endoleak occurrence, and reintervention rates were analyzed. METHODS: A systematic search was conducted in the PubMed/MEDLINE and Embase databases. Studies describing the use of physician-modified fenestrated stent grafts planned with three-dimensional tools were included. Meta-analyses were performed using a random-effects model with restricted maximum likelihood estimation. A logit transformation was used for the analysis of proportions. RESULTS: The analysis included five studies involving 172 patients. The estimated weighted mean follow-up duration was 14.9 months. The overall technical success rate was 92.9% (95% confidence interval [CI]: 84.5-96.9%), with low-to-moderate heterogeneity. Target vessel patency was 96.9% (95% CI: 93.6-98.5%). Early mortality was 5.5% (95% CI: 2.1-13.3%). The incidence of endoleaks was 13.3% (95% CI: 5.8-27.4%), with significant heterogeneity among studies. Reinterventions were reported in 6.6% of patients (95% CI: 2.3-17.5%). CONCLUSION: The results indicate that PMSG procedures planned with three-dimensional techniques are associated with a high rate of technical success and preserved patency of target vessels in patients with complex aortic pathology. The observed variability in endoleak and reintervention rates likely reflects differences in anatomical complexity and patient selection among studies. Further prospective studies are needed to confirm long-term outcomes.

Humans

Soft Tissue Volume Augmentation at Single Implant Sites Applying Collagen Matrices or Connective Tissue Grafts: 10-Year Follow-Up of a Randomized Controlled Trial.

AIM: To compare up to 10&#x2009;years clinical, profilometric and patient-reported outcomes of implant sites previously augmented using a volume-stable collagen matrix (VCMX) or connective tissue graft (SCTG) in the aesthetic zone. METHODS: The original non-inferiority randomized controlled trial (RCT) enrolled 20 patients who received soft tissue volume augmentation with VCMX or SCTG at single implant sites. Clinical assessments and standardized measurements were performed at baseline after crown insertion and at 6&#x2009;months, 1, 3, 5, 7.5, and 10&#x2009;years. The primary outcome was mucosal thickness. Secondary outcomes included marginal bone levels (MBL), probing depth (PD), bleeding on probing (BOP), plaque control record, Pink Aesthetic Score (PES), OHIP-14 and buccal profilometric changes. Group comparisons were performed using mixed-effects and generalized estimating equation (GEE) models, which account for within-patient correlations due to repeated measurements and allow inclusion of all available data without requiring imputation for missing observations. RESULTS: Of the 20 originally enrolled patients, 10 (5 in the SCTG group and 5 in the VCMX group) were available for re-examination at 10&#x2009;years. The adjusted between-group difference in mucosal thickness was -0.02&#x2009;mm (95% CI -0.99 to 0.96). As the lower bound of the confidence interval remained above the prespecified non-inferiority margin of -1&#x2009;mm, non-inferiority of VCMX was shown. Buccal contour changes were comparable during the early follow-up, while a trend toward a greater long-term contour decrease was observed in group VCMX (-0.31&#x2009;mm [95% CI, -0.65 to 0.03]; p&#x2009;=&#x2009;0.07). Mean PES values were 10.6 in the SCTG group and 9.6 in the VCMX group, with no significant between-group differences (p&#x2009;=&#x2009;0.45). Both groups revealed high levels of oral health-related quality of life, with low median OHIP-14 scores (SCTG, 0.0; VCMX, 1.0; p&#x2009;=&#x2009;0.26). CONCLUSION: These preliminary long-term findings showed no clinically relevant differences between SCTG and VCMX in terms of clinical, profilometric and patient-reported outcomes. While SCTG remains the reference standard, VCMX represents a less invasive alternative but with a slight tendency toward greater long-term contour reduction. CLINICAL SIGNIFICANCE: Volume-stable collagen matrices serve as a viable alternative to autogenous connective tissue grafts for peri-implant soft tissue volume augmentation, particularly in patients seeking a reduced morbidity, without compromising long-term clinical or aesthetic outcomes. TRIAL REGISTRATION: German Clinical Trials Register: DRKS00017484.

Humans

Aortoesophageal Fistula: Mending the Lethal Connection-A Systematic Review and Meta-Analysis.

BACKGROUND: Aortoesophageal fistula (AEF) is a rare, life-threatening condition with limited high-quality evidence to guide management. METHODS: We conducted a systematic review and meta-analysis of PubMed and Scopus through December 2025, evaluating survival and complication outcomes according to treatment strategy and morphological severity. Patients were categorized into 5 groups: TEVAR alone, staged TEVAR followed by surgery, primary open or hybrid surgery, TEVAR with esophageal stenting, and supportive/palliative care. Outcomes were pooled as proportions with 95% confidence intervals (CIs). RESULTS: A total of 167 reports representing 528 patients were included. Overall 30-day mortality was 31.2% (95% CI 27.0% to 35.7%) and 1-year mortality 41.2% (95% CI 36.2% to 46.4%). Infection occurred in 32.6%, reintervention in 20.2%, and recurrence in 13.2%. Staged TEVAR followed by surgery showed favorable survival (30-day 12.7%, 1-year 26.1%) but high infection (66.7%) and reintervention (43.2%) rates. TEVAR with esophageal stenting had the lowest early mortality (5.0%) but frequent reintervention (54.5%) and 1-year mortality of 33.3%. TEVAR alone demonstrated the lowest 1-year mortality among definitive strategies (25.5%) but notable recurrence (26.9%). Primary open or hybrid surgery carried higher early and late mortality, while supportive/palliative care had the worst outcomes. Morphological severity correlated strongly with mortality, infection, reintervention, and recurrence, with type IV lesions showing particularly poor prognosis. CONCLUSION: Despite contemporary management, AEF carries high early and late mortality. Definitive strategies, particularly staged TEVAR followed by surgery, offer improved survival but increased complications. Morphology-guided, individualized management is recommended.

Adult

Efficacy and Safety of Autologous Versus Prosthetic Grafts in the Repair of Popliteal Artery Aneurysms: A Systematic Review and Meta-Analysis.

BACKGROUND: Popliteal artery aneurysms (PAAs) present a severe risk of progression to acute limb ischemia. Open surgery (OS) is the gold standard treatment; however, prosthetic grafts are acceptable in highly selected cases, especially when the great saphenous vein is not available. METHODS: We performed a systematic review and meta-analysis of studies comparing autologous versus prosthetic grafts for patency and limb preservation outcomes in patients with PAAs. MEDLINE, Embase, and Cochrane Central were systematically searched from inception through October 2024. Outcomes were pooled using a frequentist random-effects model as odds ratios, mean differences, and hazard ratios (HRs) with 95% confidence intervals (CIs) on RStudio (Version 4.5.0). Risk-of-bias assessments were performed using ROBINS-I and MINORS. RESULTS: Twenty-two observational studies were pooled comprising 9,145 PAAs in 8,370 patients, of whom 6,434 (74.51%) were treated with autologous grafts and 2,200 (25.49%) with prosthetic grafts. Follow-up ranged from 12 to 86 months. Repair with autologous conduits significantly improved long-term primary patency (HR 3.93; P < 0.001), secondary patency (HR 6.02; P < 0.001), and long-term limb salvage (HR 2.69; P = 0.044) compared with prosthetic conduits. There were no significant differences in in-hospital amputation (P = 0.36), myocardial infarction (P = 0.61), mortality (P = 0.50), 2-year primary patency (P = 0.25), 5-year secondary patency (P = 0.06), or length of hospital stay (P = 0.95). Risk of bias was classified as moderate-to-high, reflecting confounding factors inherent to observational studies and moderate methodological quality by MINORS. Despite these limitations, treatment effects consistently favored autologous grafts in both short- and long-term analyses; however, caution is warranted given the limited number of available studies. CONCLUSION: The use of autologous conduits significantly favors both short-term and long-term efficacy and safety in the OS repair of PAAs. Given the limitations of the existing evidence, further comparative studies are needed.

Humans

Influence of nicotine on protein expression around hydrophilic osseointegrated implants: A proteomic study in male rats.

OBJECTIVE: To ensure the success of dental implant treatment, various factors must be considered, including osseointegration and systemic conditions. There is evidence in the literature that smokers may exhibit alterations in tissue healing, which can compromise the success of implant rehabilitation. Therefore, this study aimed to investigate the influence of nicotine on the protein profile of bone tissue around hydrophilic implants during the osseointegration process in rats. DESIGN: Bone tissue samples from the control and nicotine groups (n&#x202f;=&#x202f;3 per group) were subjected to protein extraction, mass spectrometry, and bioinformatic analyses. Protein identification was performed using Proteome Discoverer 2.1 software and the SEQUEST algorithm, and the protein data were compared with those of a protein database of Rattus norvegicus obtained from UniProt. RESULTS: A total of 740 proteins were detected in both the control group and the nicotine-exposed group. Among them, the proteins biglycan, periostin and histone H4 were highlighted because of their higher abundance in the healthy implant group, while they were reduced in the nicotine-exposed group. CONCLUSIONS: Nicotine has the potential to alter the protein profile of bone tissue around hydrophilic implants during osseointegration, which may impair tissue remodeling and healing.

Animals

Flap Versus Tunneling for Horizontal Ridge Augmentation With FDBA and i-PRF: A Randomized Controlled Clinical Trial.

AIM: This study evaluated the efficacy of conventional flap and tunneling techniques for horizontal alveolar ridge augmentation using freeze-dried bone allograft (FDBA) particles combined with injectable platelet-rich fibrin (i-PRF). MATERIALS AND METHODS: Forty-five patients were randomly allocated to one of three groups (n&#x2009;=&#x2009;15 each): conventional flap (CF), tunneling with membrane (TM), or tunneling without membrane (TnM). Preoperative ridge width was measured via cone beam computed tomography (CBCT). All augmentation procedures incorporated FDBA and i-PRF; an absorbable collagen membrane was applied in the CF and TM groups. Follow-up assessments, including CBCT imaging and histomorphometric analysis, were conducted 6&#x2009;months postoperatively. For normally distributed data, ANOVA with Tukey's post hoc test and paired samples t-test were applied. Non-normally distributed data were analyzed using Kruskal-Wallis, Mann-Whitney U, and Wilcoxon signed-rank tests. RESULTS: Statistical analysis was performed on 43 patients. All groups demonstrated an increase in ridge width after 6&#x2009;months. At the 2&#x2009;mm level, the mean width gain was 1.28&#x2009;mm (95% CI: 0.17 to 2.40) in the TM group, 2.85&#x2009;mm (95% CI: 1.80 to 3.89) in the TnM group, and 1.95&#x2009;mm (95% CI: 1.07 to 2.83) in the CF group. However, statistical analysis revealed no significant intergroup variation (p&#x2009;>&#x2009;0.05). Histomorphometric assessments similarly demonstrated comparable outcomes across all groups, with no statistically significant differences observed (p&#x2009;>&#x2009;0.05). CONCLUSION: Within the limitations of this study, the tunneling technique, regardless of membrane use, appears to be a clinically viable alternative to the conventional flap method for horizontal alveolar ridge augmentation. However, further studies with longer follow-up periods are required to substantiate these findings. TRIAL REGISTRATION: irct.behdasht.gov.ir identifier: IRCT 20101204005305N21.

Humans