Search PubMedSearch

SEARCH · Search PubMed

Results for “Compression dressing”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

29 recordsLinked to original sources

The effect of compression dressing on postoperative outcomes after upper eyelid blepharoplasty: a randomized, controlled, observer-blinded evaluation study.

PURPOSE: This study aimed to evaluate the impact of a compression dressing on postoperative pain, ocular surface changes, edema, ecchymosis, and aesthetic outcomes following upper eyelid blepharoplasty. METHODS: This observer-blinded, randomized, controlled trial included 112 eyelids from 56 patients who underwent bilateral upper eyelid blepharoplasty between June and August 2025. After surgery, one eyelid received a compression dressing (CD), while the other eyelid received no dressing (ND). Edema and ecchymosis were graded by masked observers on postoperative days 1, 7, 30, and 90. Aesthetic outcomes were evaluated using the Global Aesthetic Improvement Score. Pain was evaluated using a visual analog scale, and patient comfort was assessed by side preference. RESULTS: On postoperative day 1, ecchymosis scores were significantly lower in the CD group than in the ND group (unadjusted p = 0.002; Holm-adjusted p = 0.012). Edema scores were also lower on the CD side (unadjusted p = 0.012) and aesthetic scores were higher (unadjusted p = 0.046); however, neither difference remained statistically significant after Holm-Bonferroni correction for multiple comparisons (adjusted p = 0.060 and p = 0.138, respectively). No significant differences were observed in any parameter on postoperative days 7, 30, or 90 (all adjusted p > 0.05). Corneal staining scores were comparable between groups at all follow-ups, and no corneal erosions were observed. Pain scores on day 1 were similar (p = 0.977). CONCLUSIONS: Compression dressing after upper eyelid blepharoplasty was associated with a significant reduction in early postoperative ecchymosis, an effect that persisted after correction for multiple comparisons. Reductions in edema and improvements in aesthetic scores were observed on postoperative day 1 but did not remain statistically significant after adjustment. Overall, the benefits of compression dressing were limited in magnitude and transient, and routine use may not be necessary; its application should be individualized according to patient needs. TRIAL REGISTRATION: ClinicalTrials.gov, NCT07701265 (retrospectively registered on July 8, 2026).

Humans

Electrospun Nanofiber Dressings for Diabetic Wounds: From Single-Layer to Intelligent Composite Systems.

Diabetic chronic wounds have become a major challenge for clinical treatment due to their complex pathological microenvironment, including persistent inflammatory response, angiogenesis disorder, excessive oxidative stress, and susceptible infection. Traditional dressings as a passive barrier have difficulty meeting the above multiple treatment needs. Electrospinning technology, with its ability to mimic the fibrous network structure of the natural extracellular matrix (ECM), offers a high specific surface area, controllable porosity, and excellent drug-loading capacity, making it an ideal platform for developing a new generation of multifunctional wound dressings. This article provides a systematic review of the research progress on electrospun nanofiber dressings in the treatment of diabetic wounds, focusing on the design evolution from basic single-layer structures to advanced complex structures and elucidating the mechanisms of action and quantifiable effects of each structural type in addressing specific pathological challenges. We also compared the current status of clinical translation for electrospun dressings with that of other advanced wound care platforms and proposed a standardized preclinical evaluation framework. A large number of research data show that these advanced designs can effectively improve the quality of healing. Finally, this paper points out the challenges faced by this field, such as scalable fabrication, in vivo reliability of smart systems, and long-term biosafety, and provides theoretical basis and technical reference for the design of efficient and intelligent electrostatic spinning diabetic wound dressings.

Nanofibers

Effectiveness of chlorhexidine gluconate-impregnated dressings in preventing central line-associated bloodstream infection in a paediatric intensive care unit: A randomised controlled trial.

OBJECTIVES: To compare the effectiveness and dermatological safety of chlorhexidine gluconate (CHG)-impregnated dressings versus conventional transparent dressings in preventing central line-associated bloodstream infection (CLABSI) in paediatric patients admitted to a PICU. METHODS: A single-blind, randomised controlled trial with a 1:1 allocation ratio was conducted in a tertiary PICU. A total of 250 paediatric patients with a central venous catheter were included (125 per group). Patient characteristics, catheter-related variables, catheter dwell time and skin alterations were recorded. The primary outcome was CLABSI, defined according to CDC/NHSN criteria. Bivariate analyses and multivariable logistic regression were performed, including clinically relevant covariates related to catheter exposure, dressing type, and vaccination status. The trial was registered at ClinicalTrials.gov (NCT07175116). RESULTS: CLABSI incidence was significantly lower in the CHG group compared with the conventional dressing group (2.4% vs. 18.4%; p&#xa0;<&#xa0;0.001). In multivariable analysis, CHG-impregnated dressings were independently associated with reduced CLABSI risk (OR = 0.15; 95% CI: 0.04-0.58). Longer catheter dwell time (OR = 1.13 per day; 95% CI: 1.04-1.22) and absence of complete vaccination (OR = 8.68; 95% CI: 2.48-30.47) were also associated with increased infection risk. Incomplete vaccination showed a similar trend without reaching statistical significance (OR = 6.48; 95% CI: 0.95-44.20). Skin alterations were more frequent in the CHG group (16.8% vs. 11.2%), predominantly in younger infants. CONCLUSIONS: CHG-impregnated dressings were associated with a significant reduction in CLABSI incidence in critically ill paediatric patients, although their use was linked to a modest increase in mild skin reactions. IMPLICATIONS FOR CLINICAL PRACTICE: CHG-impregnated dressings may be considered as part of a multifaceted infection prevention strategy, alongside appropriate catheter management, minimisation of catheter manipulation and proactive skin monitoring, with cautious and individualised use in infants.

Humans

Bipolar circumcision with mucocutaneous plane separation: A safe, precise, blood-sparing, dressing-free approach.

Conventional circumcision techniques may result in bleeding, limited control of the mucosal collar, and the need for dressings. We describe a modified bipolar technique enabling near-bloodless dissection with precise mucosal trimming. Following bipolar division of the preputial skin, the inner mucosa is separated using two forceps and retracted proximally, creating a protective plane for safe skin adjustment. The mucosal collar is trimmed with scissors. The wound is closed with sutures and 2-octyl cyanoacrylate, avoiding dressings. This technique has been performed in 55 consecutive cases (median age: 2 years and 2 months; range: 0 days-17 years and 5 months) with no reported complications over a median follow-up of 2 years and 7 months (range: 3 months-4 years and 1 month).

Humans

Reversed unidirectional transport in a Janus polyurethane/alginate dressing for directional postbiotic delivery to infected wounds.

Probiotic-derived postbiotics exhibit significant potential for infected wound control; however, their effective and localized delivery at wound sites remains a challenge. This study developed a polyurethane/alginate composite nonwoven via electrospinning to establish a postbiotic delivery platform for Bifidobacterium bifidum BD-1 (PU/Alg/BD-1). The beaded fibrous hydrophobic PU layer and hydrophilic Alg layer form a wettability gradient, enabling reversed unidirectional fluid transport toward the wound interface while inhibiting backflow. In vitro results showed that PU/Alg/BD-1 exhibited significant antibacterial activity against Staphylococcus aureus and Escherichia coli and good cytocompatibility with a hemolysis rate of <5%. Targeted metabolomic analysis revealed multiple organic acids in the BD-1 metabolites, which contributed to its antibacterial activity. In vivo microbial analysis verified that PU/Alg/BD-1 effectively reduced the relative abundance of Staphylococcus at the wound site while increasing the proportions of Corynebacterium and Psychrobacter. This microbial modulation contributed to infection control in a rat full-thickness infected wound model, accompanied by a shift in the macrophage phenotype and the downregulation of inflammatory factors including IL-6, TNF-&#x3b1;, and TGF-&#x3b2; in the PU/Alg/BD-1 group. Compared with the blank control, conventional gauze, PU/Alg, and BD-1 groups, PU/Alg/BD-1 significantly promoted wound contraction and re-epithelialization and enhanced collagen deposition. Hence, this study provides an effective material construction strategy for the application of probiotic-derived postbiotics to promote wound healing, demonstrates the potential of BD-1 to regulate the wound microenvironment and accelerate healing, and thereby offers a novel approach for the treatment of infected wounds.

Journal Article

Efficacy of an Adhesive Hydrocolloid Bandage on Wound Healing: Findings of a 28-Day, Single-Centre, Randomised, Controlled Study.

This single-centre, randomised, controlled study assessed the wound healing efficacy of adhesive bandages in eligible healthy adults (N&#x2009;=&#x2009;36) aged 25-55 with Fitzpatrick skin types II and III using a model of laser-induced wounds. Here, we report data for wounds that were randomised to treatment with either a hydrocolloid bandage for multi-day use (BAND-AID Adhesive Bandage Hydroseal), standard of care (SoC) (BAND-AID Adhesive Bandage Tru-Stay Sheer) or an uncovered control. Primary endpoints included the time to complete healing and a composite wound healing score. Hydrocolloid bandage-treated wounds healed twice as fast as the uncovered control or SoC-treated wounds. Median time (days) to complete healing was significantly faster for the hydrocolloid bandage-treated wounds (6.9) versus SoC (11.9) and uncovered control (11.8). Hydrocolloid bandage-treated wounds had significantly better composite wound healing scores versus SoC and versus uncovered control over 2&#x2009;weeks. At Day 28, cosmesis was better with hydrocolloid bandage treatment (0.3) versus SoC (0.6) and uncovered control (2.1) (change from baseline in a composite scar score; higher score&#x2009;=&#x2009;worse outcome). Multi-day wound occlusion with a hydrocolloid bandage promoted faster healing and improved cosmesis compared with daily SoC dressings or uncovered control.

Humans

Effects of Vacuum Compression Therapy on Healing of Chronic Lower Limb Ulcers: A Randomised Controlled Study.

Chronic lower limb ulcers remain difficult to manage when unresponsive to conventional treatment. This study evaluated the clinical and physiological effects of vacuum compression therapy on wound healing and quality of life. Fifty patients with chronic lower limb ulcers were randomised to receive 12 sessions of vacuum compression therapy plus standard care or standard care alone over 4&#x2009;weeks. Wound dimensions, exudate, pain intensity and quality of life were assessed at baseline and post-treatment. Estimated wound volume was calculated as length&#x2009;&#xd7;&#x2009;width&#x2009;&#xd7;&#x2009;depth. Tissue oxygenation was measured at the dorsum of the foot in the experimental group. The vacuum compression therapy group showed greater improvements in wound width, depth, volume and quality of life. Estimated wound volume decreased by 61% in the intervention group, whereas no statistically significant volume reduction was observed in controls. Local tissue oxygenation in the experimental group increased by 43%. Baseline wound size was associated with poorer quality of life. Vacuum compression therapy may enhance wound healing and quality of life in patients with chronic lower limb ulcers. Observed increases in local tissue oxygenation represent exploratory physiological findings within the treated cohort that warrant controlled comparative evaluation. Trial Registration: ClinicalTrials.gov identifier: NCT07737184.

Humans

Comparative efficacy of percutaneous vertebroplasty combined with minimally invasive pedicle screw fixation versus percutaneous vertebroplasty alone in the treatment of elderly osteoporotic vertebral compression fractures.

The study aimed to assess the comparative efficacy of percutaneous vertebroplasty (PVP) combined with minimally invasive pedicle screw fixation versus PVP alone in elderly patients with osteoporotic vertebral compression fractures (OVCF). Ninety-four elderly patients with OVCF were randomly classified into the control (47 patients) and combined (47 patients) groups. The control group received PVP, while the combined group received PVP combined with minimally invasive pedicle screw fixation. Perioperative indicators such as intraoperative blood lose, operative time, and hospitalization time were recorded. Pain was assessed using the VAS before and at baseline and 1, 3, and 7 days postoperatively. At 1 and 3 days postoperatively, Serum CRP levels, WBC, and neutrophil counts were measured postoperatively. Radiographic outcomes (vertebral height ratio and Cobb angle), ADL scores, JOA scores, and ODI were evaluated preoperatively and at 3 months post-operation. Postoperative complications were documented. Baseline characteristics were comparable. The combined group showed superior pain relief, vertebral height restoration, Cobb angle correction, functional recovery, and reduced inflammatory markers (CRP, WBC, neutrophils) postoperatively (all P&#x2009;<&#x2009;0.05). Blood loss and hospital stay were shorter in the combined group, though operative time was longer (P&#x2009;<&#x2009;0.05). Complication rates did not differ significantly (P&#x2009;>&#x2009;0.05). PVP combined with minimally invasive pedicle screw fixation yields better outcomes in elderly OVCF patients by enhancing pain control, vertebral height, and functional recovery without increasing perioperative risk.

Humans

Unconfined compressive strength prediction for the ordinary Portland cement-steel slag-silica fume ternary system based on response surface methodology.

This research was undertaken to address environmental concerns associated with industrial solid waste and to reduce cement consumption in geotechnical engineering. It specifically investigates the feasibility of using steel slag (SS) and silica fume (SF) as partial substitutes for ordinary Portland cement (OPC) in soil stabilization. The effects of SS, SF, OPC, and initial moisture content on the unconfined compressive strength (UCS) of stabilized soil were investigated through single-factor experiments and response surface methodology (RSM). The results show that SS and SF can synergistically enhance the strength of stabilized soil, although their interaction effect was not statistically significant within the investigated ranges. Compared with soil stabilized solely with OPC, the addition of 18 % SS and 10 % SF reduced OPC consumption by 3 % without compromising strength. Microstructural and compositional analyses further revealed that SS mainly supplied calcium- and silica-bearing components, while SF provided highly reactive silica and micro-filling effects, jointly promoting hydration reactions and improving the compactness of the stabilized soil matrix. As a result, more hydration products were formed in the OPC/SS/SF-stabilized soil than in the OPC-stabilized soil, which contributed to pore filling and strength enhancement. This study provides useful guidance for the sustainable utilization of industrial solid waste and the low-carbon development of soil stabilization materials.

Construction Materials

Multilevel Revision Percutaneous Vertebroplasty in Elderly Patients With Osteoporotic Thoracolumbar Fractures: A Retrospective Cohort Study.

PURPOSE: Vertebral compression fractures (VCFs) are common complications of osteoporosis in elderly patients. Percutaneous vertebroplasty (PVP) provides pain relief and functional improvement, but some patients require revision due to refracture, cement failure, or new symptomatic levels. While outcomes of primary and multilevel augmentation have been described, systematic data on multilevel revision PVP remain rare. The aim of this study was to evaluate pain relief, functional improvement, and perioperative safety after three- and four-level revision PVP in elderly patients with osteoporotic thoracolumbar fractures. METHODS: This retrospective, single-center cohort included patients aged 75-85&#x2009;years who underwent revision PVP between August 2019 and November 2023. Eligible cases had a history of prior PVP and required repeat augmentation of three or four vertebral levels in a single session. Visual Analogue Scale (VAS) scores for pain and Oswestry Disability Index (ODI) for functional disability were recorded preoperatively and at 1-, 3-, 6-, and 12-month follow-up. RESULTS: Nine patients were analyzed. Revision involved three levels in five patients and four levels in four patients, with a mean interval of 14.1&#x2009;months after the index procedure. Mean VAS improved from 8.3&#x2009;&#xb1;&#x2009;0.7 preoperatively to 3.2&#x2009;&#xb1;&#x2009;0.6 at 12&#x2009;months (61% reduction, p&#x2009;<&#x2009;0.01). ODI improved from 75.2%&#x2009;&#xb1;&#x2009;3.4% to 26.9%&#x2009;&#xb1;&#x2009;2.7% (64% reduction, p&#x2009;<&#x2009;0.01). All patients exceeded the minimal clinically important difference thresholds. No perioperative complications such as cement leakage, neurological deficits, or pulmonary events were observed. CONCLUSION: Three- and four-level revision PVP provided significant pain relief and functional improvement in elderly patients with osteoporotic fractures, without increased complication rates. To our knowledge, this represents one of the first reports addressing this topic, suggesting it is an effective option in carefully selected patients.

Humans

The landscape of pruning for large language models: A systematic review and unified taxonomy.

Confronting the inherent tension between the exceptional capabilities and the immense computational costs of Large Language Models (LLMs), pruning has become a crucial technique for achieving efficient deployment. However, a systematic analytical framework dedicated specifically to LLM pruning remains absent. In this paper, we aim to bridge this gap. We first elucidate the theoretical foundations that underpin the effectiveness of pruning, namely overparameterization and redundancy, and then propose a multidimensional taxonomy that organizes existing approaches along the axes of granularity, timing, and criteria. Building upon this unified perspective, we further analyze performance recovery mechanisms and the broader evaluation ecosystem, while also exploring forward-looking challenges such as interpretability, automation, and hardware-algorithm co-design. Through this comprehensive synthesis, we seek to provide an integrated and coherent analytical lens for advancing both research and practice in LLM pruning.

Large Language Models

The Effectiveness of Passive Half-Time Interventions on Simulated Second-Half Performance in Elite Youth Soccer Players.

The half-time period in soccer provides a potentially important window to implement short-duration interventions aimed at maintaining second-half performance. However, passive rest has been associated with a decline in subsequent physical and technical performance. While re-warm-up strategies are well studied, little is known about the efficacy of technology-based, passive recovery modalities, device-supported interventions that require minimal active movement or physical exertion from the athlete, during half-time intervals. This study examined whether percussive therapy, electrical muscle stimulation, and pneumatic compression can mitigate second-half performance decline in male adolescent soccer players. Forty-three academy-level players (17.5 &#xb1; 0.6 years) completed a simulated soccer protocol including the Loughborough Soccer Pass Test (LSPT), repeated 20-meter sprints, and completed Total Quality of Recovery (TQR) assessments before and after half-time. Participants were randomized into one of four intervention groups during the 15-minute half-time interval: Passive Rest (CON), Percussive Therapy (Theragun Pro; TG), EMS (PowerDot; PD), and Pneumatic Compression (RecoveryAir; COMP). Linear mixed-effects models assessed Time &#xd7; Condition interactions for performance and recovery outcomes. Passive half-time rest led to significant deterioration in technical skill, sprint performance, and perceived recovery (p < .05) for the control group. TG and PD significantly improved technical performance (LSPT scores) compared to the control group (d = 0.65 and 0.72, respectively; p < .01). Furthermore, TG and COMP were effective at maintaining 20-meter sprint times (d = 0.58 and 0.49; p < .01), whereas the control group experienced significant slowing. Perceived recovery (TQR) scores significantly declined in the CON group from First Half to Second Half (16.5 &#xb1; 2.2 to 11.1 &#xb1; 2.3. However, this decline was significantly attenuated in all intervention groups: TG (17.5 &#xb1; 1.9 to 14.2 &#xb1; 1.9), PD (17.3 &#xb1; 1.9 to 15.1 &#xb1; 1.9), and COMP (17.6 &#xb1; 1.9 to 15.9 &#xb1; 2.0). Short-duration passive interventions during half-time can mitigate performance decline in adolescent soccer players. TG and EMS appear most effective for preserving technical skills, while COMP may support perceived recovery. These findings highlight practical strategies for optimizing in-game performance and inform evidence-based half-time protocols.

Humans

Improving Sleep and PTSD Outcomes in Service Members: A Randomized Controlled Trial Examining the Long-Term Effects of an Integrated Treatment.

Trauma-induced sleep disturbances often persist after successful posttraumatic stress disorder (PTSD) treatment. While integrated protocols combining sleep and exposure-based treatments may maximize outcomes, prior studies are limited and have largely relied on subjective sleep measures or failed to include long-term follow up assessments. Active-duty service members with PTSD (n&#x202f;=&#x202f;82) were randomly assigned to Compressed Prolonged Exposure (CPE) treatment or Trauma Management Therapy (TMT), which integrates exposure therapy with sleep hygiene training and other skills-based interventions. PTSD symptoms and actigraphy-based sleep were measured at baseline, posttreatment, 3- and 6-month follow-up and data were compared between groups and across time. Posttreatment, both groups showed negligible to small changes in sleep compared to baseline. However, the TMT group evidenced improvements in most sleep parameters by the 3- and 6-month follow-ups, while sleep health generally worsened in the CPE group over time. Between groups, those randomized to TMT exhibited better sleep efficiency (g&#x202f;=&#x202f;0.24) and onset latency (g&#x202f;=&#x202f;-0.34) at 3-month follow-up, and better sleep quality (g&#x202f;=&#x202f;0.70), efficiency (g&#x202f;=&#x202f;0.51), and wake after sleep onset (g&#x202f;=&#x202f;-0.52) at 6-month follow-up. Within both treatment groups, poorer sleep at the 6-month follow-up was correlated with greater PTSD symptom severity measured at the same time point. Integrated treatment for sleep and PTSD produced superior objective sleep outcomes compared to exposure alone, with the most meaningful improvements in sleep observed 6 months after treatment completion. Several critical directions for future studies are discussed.

Humans

Orbital involvement in sickle cell disease: A systematic review.

Orbital involvement in sickle cell disease (SCD) is rare but potentially vision-threatening and is often misdiagnosed due to overlap with infectious orbital disease. We conducted a systematic review of case reports and series describing orbital complications in patients with confirmed SCD, following PRISMA and MOOSE guidelines. Across 53 studies, 76 cases were identified. Patients were predominantly male (77.6%), with an average age of 13.2 years. Orbital disease was the initial SCD manifestation in 6.6%. Presentations included periorbital edema in all, proptosis in 64.1%, restricted ocular motility in 56.5%, reduced visual acuity in 28.1%, and bilateral involvement in 38.2%. Laboratory findings commonly included leukocytosis (73%) and raised inflammatory markers (86.7%). Radiologically, orbital subperiosteal hematoma were observed in 70%, combined orbital bone infarction and hematoma in 38.2%, and orbital bone infarction alone in 19.7%. Magnetic resonance imaging is critical for accurate diagnosis. Intracranial hemorrhage was present in 9.2%. Less frequent manifestations included orbital apex syndrome, lacrimal gland disease, and nonspecific soft tissue swelling. Management was primarily conservative (82.9%), and surgery was reserved for vision-threatening or intracranial complications. Complete recovery was achieved in 93.1% of cases. While severe vision-threatening complications are uncommon, early recognition remains critical to optimising outcomes in sickle cell orbitopathy.

Humans

Impact of neoprene wetsuits on lung volumes and work of breathing: implications for military diver safety and performance.

INTRODUCTION: Neoprene wetsuits may impose mechanical constraints on the chest wall, potentially altering respiratory function. This study investigated the impact of neoprene wetsuits on lung volumes, airway mechanics, and work of breathing (WOB) in healthy male divers. METHODS: A randomised crossover trial was conducted with 31 male divers at the Royal Netherlands Navy Diving Medical Centre. Participants underwent pulmonary function testing, including spirometry, body plethysmography, the forced oscillation technique (FOT), and diffusion capacity measurements, both with and without a hoodless standardised 5 mm neoprene full body wetsuit with a neoprene neck seal. Primary outcomes included changes in forced vital capacity (FVC), functional residual capacity (FRC), airway resistance (Raw), reactance (Xrs), and WOB. RESULTS: Wearing a neoprene wetsuit led to statistically significant reductions in FVC (2.8%, P < 0.05), forced expiration in one second (2.9%, P < 0.05), FRC (4.0%, P < 0.05), and expiratory reserve volume (10.9%, P < 0.05), alongside increases in inspiratory capacity and tidal volume. Raw increased significantly (P < 0.05), while the FOT revealed altered airway mechanics, evidenced by increased Xrs at multiple frequencies (P < 0.05). Diffusion capacity remained unchanged, suggesting preserved alveolar-capillary function. CONCLUSIONS: Neoprene wetsuits induce mechanically restrictive effects on the chest wall, reducing static and dynamic lung volumes and increasing WOB. While these changes may not be clinically relevant at rest, their impact needs to be determined during strenuous or prolonged dives, particularly when combined with other equipment that limits thorax excursions. Future research should explore the effects of the military 5 mm wetsuit under immersed conditions to better understand their operational impact on diver performance and safety.

Male

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Outcomes of stereotactic radiosurgery for spine multiple myeloma-a systematic review.

Spinal involvement in multiple myeloma (MM) commonly results in pain, vertebral instability, epidural spinal cord compression, and neurological deficits. Although conventional external beam radiation therapy (EBRT) remains the standard radiation modality because of the radiosensitive nature of MM, stereotactic radiosurgery (SRS) has emerged as a highly conformal treatment option capable of delivering focal high-dose radiation while sparing adjacent spinal cord structures and uninvolved bone marrow. This systematic review evaluated the clinical outcomes and safety profile of SRS for spinal MM.&#xa0;A systematic review of the literature was performed to identify studies evaluating SRS for spinal MM. Extracted variables included patient demographics, tumor characteristics, treatment parameters, radiographic outcomes, pain response, neurological outcomes, local control, overall survival, and adverse events.&#xa0;Three retrospective studies comprising 133 patients and 181 treated spinal lesions met the inclusion criteria. Median patient age ranged from 59 to 65 years, with a slight male predominance across studies. Thoracic spine lesions represented the most treated region (55.5-67.7%). Median prescribed SRS dose was 14-16&#xa0;Gy, predominantly delivered in a single fraction. Median follow-up ranged from 11.2 to 27.8 months. Local control rates ranged from 89.4 to 100%, with 6- and 12-month local control rates of 94% and 91%, respectively, in one study. Pain improvement was reported in 41-88% of treated patients/sites, with a median time to pain relief of 1.6 months in one cohort. Neurological improvement occurred in 56-71.4% of patients with preexisting deficits. Reported adverse events included vertebral compression fractures, fracture progression, pain flare, and tracheoesophageal fistula. De novo vertebral fractures ranged from 3.6 to 7%, while fracture progression ranged from 14 to 18%.&#xa0;SRS appears to provide excellent local control and meaningful pain and neurological improvement in patients with spinal MM, with acceptable toxicity profiles. The highly conformal nature of SRS may preserve uninvolved bone marrow and facilitate continuation of systemic therapy. However, the current evidence is limited to small retrospective studies with heterogeneous reporting, and further prospective comparative studies are needed to better define the role of SRS relative to conventional EBRT in spinal MM.

Humans

Seed-derived mucilage polysaccharides as biomaterials for in vivo tissue regeneration: A systematic review.

Chronic wounds, bone defects, and cartilage injuries represent persistent clinical challenges requiring biomaterial platforms that actively regulate inflammation, oxidative stress, angiogenesis, and extracellular matrix remodeling. Conventional synthetic dressings often provide limited biological activity in these contexts. Seed-derived mucilages - polysaccharide-rich hydrocolloids obtained from chia (Salvia hispanica), flaxseed (Linum usitatissimum), fenugreek (Trigonella foenum-graecum), psyllium (Plantago ovata), guar (Cyamopsis tetragonoloba), quince (Cydonia oblonga) etc. - have emerged as biocompatible, biodegradable, and chemically versatile platforms for tissue engineering. This systematic review, conducted according to PRISMA 2020 guidelines, synthesized in vivo evidence on seed-derived mucilage-based biomaterials across wound healing, bone repair, cartilage regeneration, and related applications. PubMed, Scopus, and Web of Science Core Collection were searched for original in vivo experimental studies published in English between 2020 and 2026. Eligible studies reported at least one measurable regenerative outcome. Data were extracted independently by two reviewers, and methodological quality was assessed using the SYRCLE Risk of Bias tool. Forty-three studies were included. Hydrogels were the dominant biomaterial format, followed by films, scaffolds, sponges, nanoparticle systems, and bilayer or Janus composites. Included systems generally improved wound closure, re-epithelialization, collagen deposition, angiogenesis, antioxidant defense, and inflammatory regulation. However, most studies used small animals with short follow-up periods, and many incorporated nanoparticles or bioactive agents, limiting attribution of efficacy to the mucilage matrix alone. Risk of bias was predominantly unclear due to insufficient reporting of randomization and blinding. Blank mucilage controls, standardized characterization, long-term biosafety data, and clinically relevant models are essential prerequisites for translational progress.

Humans