Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Catheter Ablation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Predictors of recurrence following catheter ablation of atrial fibrillation using an irrigated-tip ablation catheter.

INTRODUCTION: The aims of this study were to identify predictors of recurrence after catheter ablation of atrial fibrillation (AF) and to report the safety and efficacy of catheter ablation of AF using an irrigated-tip ablation catheter. METHODS AND RESULTS: Seventy-five consecutive patients (51 men [68%]; age 54 +/- 13 years) with symptomatic drug-refractory paroxysmal (42 patients), persistent (21 patients), or permanent (12 patients) AF underwent catheter ablation of AF using an irrigated-tip ablation catheter and a standard ablation strategy, which involved electrical isolation of all pulmonary veins (PVs) and creation of a cavotricuspid linear lesion. At 10.5 +/- 7.5 months of follow-up following a single (n = 75) or redo ablation procedure (n = 11), 39 (52%) of the 75 patients were free of AF, 10 were improved (13%), and 26 had experienced no benefit from the ablation procedure (35%). Seventy-six percent of patients with paroxysmal AF were free from recurrent AF. The most significant complications were two episodes of pericardial tamponade, mitral valve injury in one patient, two strokes, and complete but asymptomatic PV stenosis in one patient. Cox proportional hazards multivariate regression analysis identified the presence of persistent AF, permanent AF, and age >50 years prior to the ablation are the only independent predictors of AF recurrence after the first PV isolation procedure. CONCLUSION: Catheter ablation of AF using a strategy involving isolation of all PVs and creation of a linear lesion in the cavotricuspid isthmus using cooled radiofrequency energy is associated with moderate efficacy and an important risk for complications. The best results of this procedure are achieved in the subset of patients who are younger than 50 years and have only paroxysmal AF.

Adult↗

Gold-tip electrodes--a new "deep lesion" technology for catheter ablation? In vitro comparison of a gold alloy versus platinum-iridium tip electrode ablation catheter.

Gold-tip electrodes. Radiofrequency (RF) catheter ablation is widely used to induce focal myocardial necrosis using the effect of resistive heating through high-frequency current delivery. It is current standard to limit the target tissue-electrode interface temperature to a maximum of 60-70 degrees C to avoid char formation. Gold (Au) exhibits a thermal conductivity of nearly four times greater than platinum (Pt-Ir) (3.17 W/cm Kelvin vs 0.716 W/cm Kelvin), it was therefore hypothesized that RF ablation using a gold electrode would create broader and deeper lesions as a result of a better heat conduction from the tissue-electrode interface and additional cooling of the gold electrode by "heat loss" to the intracardiac blood. Both mechanisms would allow applying more RF power to the tissue before the electrode-tissue interface temperature limit is reached. To test this hypothesis, we performed in vitro isolated liver and pig heart investigations comparing lesion depths of a new Au-alloy-tip electrode to standard Pt-Ir electrode material. Mean lesion depth in liver tissue for Pt-Ir was 4.33+/-0.45 mm (n=60) whereas Au electrode was able to achieve significantly deeper lesions (5.86+/-0.37 mm [n=60; P<0.001]). The mean power delivered using Pt-Ir was 6.95+/-2.41 W whereas Au tip electrode delivered 9.64+/-3.78 W indicating a statistically significant difference (P<0.05). In vitro pig heart tissue Au ablation (n=20) increased significantly the lesion depth (Au: 4.85+/-1.01 mm, Pt-Ir: 2.96+/-0.81 mm, n=20; P<0.001). Au tip electrode again applied significantly more power (P<0.001). Gold-tip electrode catheters were able to induce deeper lesions using RF ablation in vitro as compared to Pt-Ir tip electrode material. In liver and in pig heart tissue, the increase in lesion depth was associated with a significant increase in the average power applied with the gold electrode at the same level of electrode-tissue temperature as compared to platinum material.

Animals↗

Effect of isthmus anatomy and ablation catheter on radiofrequency catheter ablation of the cavotricuspid isthmus.

BACKGROUND: Cavotricuspid isthmus (CTI) characteristics are rarely documented when comparing catheters in radiofrequency ablation (RFA) of atrial flutter (AFL). Our objectives were (1) to evaluate the impact of CTI morphology and length on ablation procedures and (2) to compare the efficacy of an 8-mm-tip catheter with an irrigated cooled-tip RFA in the subgroup presumed to be more difficult to treat (with a long CTI, >35 mm). METHODS AND RESULTS: Over a period of 17 months, 185 patients accepted the protocol and underwent an isthmogram in preparation for RFA. Groups were classified according to CTI length and CTI morphology. RFA was performed with an 8-mm-tip catheter for patients with a short CTI, < or =35 mm (n=123), whereas randomization between an 8-mm-tip and a cooled-tip catheter applied to patients with a longer CTI, >35 mm (n=62). For long CTI, 32 patients were assigned to an 8-mm catheter and 30 patients to the cooled-tip RFA ablation group. In this subset, RF application (18.2+/-17 versus 19+/-13 minutes) and x-ray exposure (20.8+/-18 versus 18+/-13 minutes) did not differ between the 8-mm-tip and the cooled-tip procedures. Number of applications (9.9+/-11 versus 18.6+/-15 minutes; P<0.0001) and x-ray exposure (11.7+/-11 versus 19.5+/-16 minutes, P=0.0001) differed significantly between patients with short and long CTIs. Patients with short and straight CTIs required 3 times fewer RFA applications and shorter x-ray exposure compared with other CTI morphologies (pouch-like recesses and concave characteristics). CONCLUSIONS: The number of RF applications required for a complete isthmus block in long CTIs is not influenced by the choice between an 8-mm or cooled-tip catheter. Procedure parameters, however, are significantly influenced by CTI length and morphology. Pouch-like recesses and concave characteristics account for much longer ablation times at all CTI lengths.

Adult↗

New horizons in catheter ablation.

Catheter ablation has evolved into the dominant therapeutic modality in the treatment of a variety of arrhythmias, particularly supraventricular arrhythmias with the mechanisms of atrioventricular (AV) nodal reentry and AV reciprocating tachycardia via an accessory pathway. The mode of catheter ablation used in the great majority of cases is radiofrequency (RF) catheter ablation. This technology is well-suited for the above arrhythmias because the targets and the RF lesions are both small and discrete. Using temperature monitoring may improve the outcome of these procedures by decreasing procedure time and incidence of coagulum formation on the catheter after a sudden rise in electrical impedance. New RF catheter designs and new modalities of creating catheter-induced focal myocardial injury will allow operators to have improved success with the ablation of less approachable arrhythmias, including atrial flutter and reentrant ventricular tachycardia. Studies are currently underway to create a catheter based "maze" procedure for the treatment of atrial fibrillation. As techniques and technologies evolve, a greater proportion of patients with symptomatic or threatening arrhythmias may be approached with catheter ablation as a curative or palliative procedure.

Catheter Ablation↗

Catheter ablation.

Catheter ablation is gaining increasing interest for the therapy of symptomatic, sustained arrhythmias of various origins. The scope of this review is to give an overview of the biophysical aspects and major characteristics of some of the most widely used energy sources in catheter ablation, e.g., the discharge of conventional defibrillators, modified defibrillators, laser light, and radiofrequency current application. Results from animal studies are considered to explain the basic mechanisms of catheter ablation. The recent achievements with the use of radiofrequency current to modify or ablate cardiac conduction properties are outlined in more detail.

Animals↗

Atrial fibrillation: catheter ablation.

Catheter ablation of atrial fibrillation (AF) has evolved dramatically over the last several years. The initial efforts in the catheter-based management of AF targeted the atrial substrate in an effort to mimic the maze procedure. After the pulmonary veins (PV) were shown to be critical in the initiation and perpetuation of AF, the focus then shifted to a trigger approach in which the PVs and other foci were targeted for ablation. The pendulum then appeared to swing back toward the substrate approach after it was shown that left atrial circumferential ablation afforded improved outcomes in patients with paroxysmal and persistent AF. It has become clear that there are several possible approaches in the catheter ablation of AF, each with its strengths and limitations. It is also becoming evident that not all patients will respond to a single ablation technique and that the ablation protocol is best tailored to suit the individual patient. This article strives to present an evidence-based review of the many techniques, and then offer a practical guide to the catheter ablation of AF.

Atrial Fibrillation↗

[Current treatment of Wolff-Parkinson-White syndrome and ventricular tachycardia: surgical ablation versus catheter ablation?].

From November 1973, 454 patients with Wolff-Parkinson-White syndrome underwent surgical ablation of accessory pathways. Overall curative rate was 94% in our series including 65 cases of simultaneous surgical repair for combined heart diseases. In recent months, radiofrequency catheter ablation was applied in 7 cases. There has been 2 failures, which have taken more than 2 hours of radiation exposure and have required surgery. There has been 47 patients who underwent surgical ablation for non-ischemic ventricular tachycardia. Forty cases (85%) had a successful outcome of surgical ablation and another 2 cases required DC catheter ablation postoperatively to eliminate ventricular tachycardias. In conclusion, radiofrequency ablation of WPW syndrome in patients without combined heart disease or multiple accessory pathways is feasible. Surgical ablation is effective and safe technique compared with catheter ablation in patients with ventricular tachycardia.

Adolescent↗

Factors associated with recurrence of accessory pathway conduction after radiofrequency catheter ablation.

Catheter ablation of 215 accessory pathways (APs) using radiofrequency current (RF) was attempted in 204 consecutive patients. Two hundred twelve of the 215 (99%) APs were successfully ablated. After a minimum of follow-up period of 1 month (mean 8.5 +/- 5.4 months), AP conduction had returned in 17 patients (8%). Recurrence of AP conduction was manifest by atrioventricular (AV) reentrant tachycardia in six patients, palpitations suggestive of AV reentrant tachycardia in five patients, ventricular preexcitation on electrocardiogram in five patients, and inducible AV reentrant tachycardia during a follow-up electrophysiological study in one asymptomatic patient. AP conduction returned as early as 12 hours and as late as 4.7 months, but was evident within 2 months of ablation in 15 of 17 (88%) patients. AP conduction recurred in 12%-14% of anteroseptal, right free-wall, and posteroseptal APs, but only 5% of left free-wall APs (P less than 0.01). Retrograde only conducting APs (concealed APs) had recurrence of AP conduction more frequently (16%) than APs that exhibited antegrade conduction (5.5%; P less than 0.01). Failure to record AP potentials from the ablation electrode, reflecting poor AP localization, was a strong predictor for recurrence of AP conduction. AP conduction returned in 19% of 48 APs when AP potentials were not recorded, compared to 5% of 164 APs where AP potentials were recorded from the ablation electrode (P less than 0.01). The time to block of AP conduction from the onset of RF current application was longer in APs with recurrence of conduction (4.9 +/- 6.1 sec vs 2.9 +/- 3.4 sec; P less than 0.02).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Novel applications in catheter ablation.

Catheter based treatment of arrhythmia has gained significant attention during the last two decades. Due to the explosive development in ablation treatment of atrial fibrillation, huge interest in new tools was born to help in the atrial fibrillation ablation procedures. The aim of this review is to describe the role of these novel techniques and tools aimed at improving the implementation of catheter based ablations of atrial arrhythmias by focusing on the use of intra-cardiac echocardiogram and robotic navigation.

Arrhythmias, Cardiac↗

Recording monophasic action potentials using a platinum-electrode ablation catheter.

AIMS: The monophasic action potential (MAP) is conventionally recorded using Ag-AgCl electrodes which are not suitable for delivering radiofrequency currents. To be able to use the sharp MAP upstroke for identifying the local activation, as a step towards the development of a MAP-guided catheter ablation technique, the possibility of recording MAP via platinum electrodes of an ordinary ablation catheter was explored. METHODS AND RESULTS: One hundred and forty-two MAP recordings from the endocardium were obtained via an ablation catheter in 40 patients undergoing electrophysiological study/catheter ablation. During sinus rhythm and pacing, 90% of the ventricular and 100% of the atrial MAPs had stable baselines. The amplitudes were 13 +/- 4.2 mV for ventricular and 2.4 +/- 0.8 mV for atrial MAPs. During mapping and ablation, MAPs and uni- and bipolar electrograms were recorded simultaneously using the same tip electrode in eight patients. The MAPs provided more distinct local activation than the electrograms. During 17 MAP recordings, additional MAPs were recorded simultaneously using an Ag-AgCl electrode catheter in the immediate vicinity of the ablation catheter. The MAPs taken with the ablation catheter had characteristics consistent with those taken with the Ag-AgCl catheter. CONCLUSIONS: (1) Platinum electrodes can be used for timely recording of MAPs in patients. (2) It is feasible to record MAPs and deliver radiofrequency currents via the same platinum-tip electrode. These findings suggest that MAP-guided catheter ablation is technically possible.

Action Potentials↗

Curative percutaneous catheter ablation for various supraventricular and ventricular tachyarrhythmias. Results in 187 consecutive patients during the first five years.

Closed-chest transcatheter electrical ablation (catheter ablation) has been applied to various supraventricular and ventricular tachyarrhythmias as a radical therapeutic technique since its introduction in 1982. Currently, it has become a first line therapy for supraventricular tachyarrhythmias except atrial fibrillation and uncommon types of atrial flutter. We first carried out the ablation procedure in 1991 for the treatment of ventricular tachycardia. Up to February 1997, a total of 187 patients underwent catheter ablation in our institution. The aims of this study are to demonstrate our results of catheter ablation in the early 5 years and to show the usefulness of this new curative method. Successful results were obtained in 168 of 187 patients (overall final success rate: 89.8%). The success rates of each category of tachyarrhythmias were 100/105 patients (95%) with WPW syndrome, 41/46 (89%) with atrioventricular nodal reentrant tachycardia, 7/10 (70%) with atrial flutter, 4/4 (100%) with atrial tachycardia, 2/2 (100%) with medically refractory atrial fibrillation, 13/15 (85%) with idiopathic ventricular tachycardia and 3/7 (43%) with sustained ventricular tachycardia associated with structural heart disease, respectively. Complications that required invasive treatments were observed in 3 patients (2 hemopericardium and 1 complete atrioventricular block). Our results indicate that catheter ablation is highly effective in most categories of tachyarrhythmias and can be applied safely without lethal complications.

Adult↗

[Catheter ablation in supraventricular tachycardia].

The first report about successful radio frequency ablation of a right-posterior-septal accessory pathway appeared in 1986. Since then, the technology of both guidable ablation catheters and radio frequency generators has been considerably improved in an initially clinical-experimental phase. At the same time, electrophysiologists were equally able to enlarge their knowledge in the field of signal characteristics of arrhythmogenic substrates. This included the discovery of action potentials of accessory pathways (preexcitation syndromes), the location of fast and slow AV node conduction (AV nodal reentrant tachycardia, AVNRT), the functional importance of the anatomical isthmus between the os of the coronary sinus, the tricuspid valve and the inferior caval vein (atrial flutter). Mapping techniques such as transient and concealed entrainment became, among others, significant tools in finding the best localization for radio frequency catheter ablation. Thus, technical development and the increased knowledge of clinical electrophysiologists resulted in firmly establishing the procedure of catheter ablation as the method of first choice in the curative treatment of supraventricular tachycardias in a potential collective of about 5 per mill of the normal population (without atrial fibrillation). Supraventricular tachycardias with a reentry mechanism in the broadest sense (> 95% of all pts. with SVT) and those with focal automaticity (< 5%) occur as atrial fibrillation or atrial flutter in about 60% of all pts. (4-6 per mill of the normal population). Manifestation of the remaining reentrant tachycardias is mainly in the form of AVNRT (retrograde conduction via the fast pathway > 90% versus uncommon type < 10%). AV reentry via accessory pathways is found in about 15%, with orthodromic conduction via the AV node (> 90%). Atrial reentrant tachycardias are rather rare (with the exception of atrial fibrillation/flutter). The literature suggests medical therapy to be successful in about 60% of these patients. Those patients who are presently proposed to receive radio frequency catheter ablation usually continue to be symptomatic despite pharmacological therapy and/or have a potential risk for sudden cardiac death due to atrial fibrillation in WPW syndrome, or rate-dependent hemodynamic compromise secondary to cardiac disease. Since 1989-1995, our laboratory had a > 93% success rate in treating 466 patients with AV reentrant tachycardia via accessory AV pathways, and in treating 398 patients with AV nodal reentrant tachycardias. Forty patients with atrial flutter and 16 patients with different atrial tachycardias (14 with focal origin, 2 reentries) were free from tachycardia in 80% after ablation. This corresponds to the literature published by other centers. Some abstracts and articles suggest that ablation of atrial fibrillation may be possible. However, there is still a lack of basic experience with view to mapping procedures and, thus, insufficient knowledge of the electrophysiological pathophysiology with regard to different cardiac diseases. As a consequence, this procedure, despite first documentation of both successful treatment and severe complications occurring in catheter ablation of atrial fibrillation, as based on the experience of the MAZE procedure, is applied in humans, at the time being, in a purely experimental setting. The only exception relates to the ablation of the AV node at accurate diagnosis for pacemaker implantation (VVIR; DDDR switch mode) which has become part of routine therapy, although, of course, atrial fibrillation itself or necessary anticoagulation cannot be abolished. Thus, our center shows a success rate of 98% in treating 117 patients by this method. First promising reports are available describing the attempt of AV node modification in the posterior nodal part with the goal of reducing the ventricular rate in atrial fibrillation.

Atrial Fibrillation↗

Novel, magnetically guided catheter for endocardial mapping and radiofrequency catheter ablation.

BACKGROUND: Ablation of complex arrhythmias would be greatly facilitated by more precise control of ablation catheters. A feasibility study was performed in animals to evaluate a novel magnetic guidance system (MGS) that generates a magnetic field to control the movement and position of a magnetic ablation catheter. METHODS AND RESULTS: The MGS is composed of a digital biplanar fluoroscope within an array of superconducting electromagnets that surround the torso of the experimental animal and a computer control system that generates a composite magnetic field for directional catheter deflection. Magnetic catheter navigation was performed in dogs and pigs (20 to 30 kg). A 7F magnetic ablation catheter was used for intracardiac navigation and radiofrequency ablation. The performance of a standard 7F deflectable catheter was not affected by the MGS. The magnetic catheter was navigated successfully to 51 predefined targets throughout the heart in 6 animals. In 5 animals, the magnetic catheter, guided by a 3D computed tomogram, was successfully navigated to all pulmonary veins. Navigation accuracy was estimated as <1 mm displacement from the target. The magnetic catheter was used to ablate the atrioventricular node in 4 animals and to perform linear ablations across the endocardial surface underlying an epicardial multielectrode recording plaque in 4 animals. CONCLUSIONS: These results demonstrate that the MGS can navigate and stabilize an ablation catheter at endocardial targets. Linear or focal radiofrequency ablation with the magnetic catheter is not compromised by the magnetic field. This technology provides precise control of endocardial catheters.

Animals↗

Radiofrequency catheter ablation using long coiled electrodes: impact of irrigation on lesion dimensions and incidence of coagulum formation.

Ablation catheters with multiple long coiled electrodes have been recently developed to induce continuous linear lesions for the treatment of atrial fibrillation. The efficacy and safety of ablation catheters with multiple long coiled electrodes has not been evaluated. The aim of the present in vivo study was to investigate the influence of saline irrigation on lesion dimensions and coagulum formation during RF current ablation using those ablation catheters. In 14 anesthetized sheep, the thigh muscle was prepared as a cradle and filled with heparinized blood (37 degrees C). The quadripolar coiled ablation catheter (electrode length 7 mm, electrode distance 2 mm) was placed parallel to the muscle with standardized 10-g contact pressure. RF current energy was delivered sequentially temperature-(70 degrees C) or power-controlled (10, 20, 30, or 40 W) with additional irrigation of the electrode (10 mL/min normal saline) for 90 seconds. Forty-two of 129 RF current lesions were induced by temperature-controlled and 87 by irrigated ablation. Except for three lesions following low energy irrigated application (10 W), all lesions were continuous. Significantly larger lesions following irrigated RF current applications were produced with a power output of 30 W (depth 0.74 +/- 0.13 cm, width 0.78 +/- 0.13 cm) and 40 W (depth 0.75 +/- 0.16 cm, width 0.92 +/- 0.28 cm) as compared to 20 W (depth 0.47 +/- 0.13 cm, width 0.82 +/- 0.22 cm). Coagulum formation adherent to the electrode was exclusively observed following 18 of 42 nonirrigated RF current ablations. In conclusion, irrigated coiled ablation electrodes induce continuous linear lesions with a power output of 20-40 W. The risk of coagulum formation at the coiled electrode can be avoided by irrigation.

Animals↗

Remote-controlled catheter ablation of accessory pathways: results from the magnetic laboratory.

AIMS: This study evaluates feasibility, safety, and efficacy of magnetic remote-controlled accessory pathway (AP) ablation. METHODS AND RESULTS: The novel magnetic navigation system (MNS) (Niobe, Stereotaxis) creates a steerable magnetic field (0.08 T) controlling the distal magnetic tip of an ablation catheter. In conjunction with a catheter advancer system (Cardiodrive, Stereotaxis) remote catheter ablation is enabled. Conventional electrophysiology study identified AP conduction in 59 patients (37 males, 36+/-14 years, 60 APs). First generation 1-magnet tip (1-M) (group I, n=18), second generation bipolar 3-magnet tip (3-M) (group II, n=27), and third generation quadripolar 3-magnet tip catheters (3-M quad.) (group III, n=14) were used for magnetic remote-controlled ablation. Successful AP ablation was achieved in 67% (group I), 85% (group II), and 92% (group III). A significant decrease of median [IQR: Q1-Q3] fluoroscopy time and dosage was observed: 21.2 [12.1-33.8] min, 1110 [395-3234] microGym2 (group I); 6.5 [4.4-15.4] min, 290 [129-489] microGym2 (group II), and 4.9 [3.4-8.0] min, 129 [74-270] microGym2 (group III). Mean procedure time (217+/-67 min; 182+/-68 min, and 172+/-90 min) significantly decreased in group III. Median number [Q1-Q3] of radiofrequency current applications in groups I, II, and III was 4 [2-9], 4 [2-6], and 2 [2-4], respectively. No complications occurred. CONCLUSION: Remote AP ablation is safe and feasible using the novel MNS. Introduction of the 3-magnet quadripolar ablation catheter significantly improved the efficacy of the procedure.

Adult↗

[Non-drug treatment methods in ventricular rate control in atrial fibrillation: high-frequency catheter ablation and catheter modification of the AV node].

AV nodal ablation with pacemaker implantation nor AV nodal modification is the therapy of the choice in patients with permanent or paroxysmal atrial tachyarrhythmias. Both methods of treatment are limited to patients with drug refractory atrial tachyarrhythmias. Therapy indication requires the complete knowledge of the current clinical status and medical history of the patient regarding the time course of the disease and the results of previous treatments. Both methods are effective and palliative treatments which may not modify the underlying arrhythmias. Neither treatment showed an improvement in patients prognosis; therefore a restrictive indication is mandatory.

Aged↗

Experimental study of catheter ablation using ultrasound energy in canine and porcine hearts.

UNLABELLED: We examined the efficacy and safety of ultrasound energy in eliminating the arrhythmogenic substrates of atrial as well as ventricular tissue using a newly developed instrument in both in vivo and in vitro experiments. Ultrasound (US) applicators were tested on 79 lesions created on a beating heart in canine cardiac tissue, and on 64 lesions in porcine heart specimens. US lesions were created by using transducers with frequencies around 5-10 MHz. In the in vivo study, we observed a significant decrease in the amplitude of the electrograms recorded from the tip of the ablation catheter during the US application (p < 0.01). In some sites transmural lesions could be created which were well demarcated. Blood coagulum formation was observed on the tip of the ablation catheter on several occasions. In one dog ventricular fibrillation was provoked by the delivery of ultrasound energy to the left ventricle. In the in vitro study, lesion depth increased significantly with a longer duration of energy delivery when the temperature was maintained table (p < 0.001), and the lesion depth increased significantly with higher temperatures of energy delivery when the duration of US application was maintained (p < 0.05). In both cases, no significant change in surface area was observed. The maximum depth of the lesion was 10.3 mm. CONCLUSIONS: An ultrasound energy system is relatively safe and effective for creating lesions large enough to eliminate arrhythmogenic substrates deep in the ventricular myocardium. Although the US system is free from pop phenomenon, the problem of blood coagulation on the catheter tip remains to be settled.

Animals↗