Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Capnography”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

[Non-invasive patient monitoring in veterinary medicine: pulse oximetry and capnography. II. Capnography].

Capnography measures carbon dioxide concentration or partial pressure of the respiratory gas continuously and non-invasively. The endtidal value is of great diagnostic value, it corresponds approximately to the arterial value, except for ventilation-perfusion-mismatching (horse), shunting (horse), or increased dead-space-ventilation (panting in the dog). Capnography primarily serves for monitoring of spontaneous and artificial ventilation, it is a reliable method for detecting hypo- and hyperventilation. Because metabolism and circulation influence the amount of carbon dioxide eliminated in the lung, capnography monitors these functions too. The plotting of the carbon dioxide concentration as a carbon dioxide-time-diagram draws attention to malfunctions of the equipment. Technical problems of capnography depend on the design of the capnograph (main- or side-stream) used as well as on the weight of the patient. In the discussion the value of pulse oximetry and capnography in detection of critical events during anaesthesia is compared. Capnography is superior to pulse oximetry in the capability to detect critical events. But pulse oximetry complements capnography perfectly, both methods together give a good impression of the patient's state of health.

Animals↗

Capnography confirms correct feeding tube placement in intensive care unit patients.

PURPOSE: To test the accuracy and potential time savings of capnography as compared with a two-step radiographic method in placing feeding tubes in critically ill patients. METHODS: One hundred feeding tube placements were studied in our tertiary care intensive care unit. All placements utilized a two-step radiographic method, but capnography was added to the procedure. The procedure was then completed or abandoned depending on radiographic interpretation. RESULTS: Radiography showed 11 feeding tubes projecting within the tracheobronchial tree. In all 11 of these placements, the capnography unit displayed a normal capnogram. Radiography revealed 86 tube placements in the midesophageal region. In all 86 of these placements, capnography displayed a "purging warning". In three placements, radiography indicated that the tube was coiled in the oropharynx. In these cases, the capnograph displayed one "no purging/no capnogram" result, and two "purging" warnings. If using capnography alone, an average of 72.5 min would be required to complete a feeding tube placement (which includes time for requisite "pre-feed radiograph"). The two-step radiological approach took an average of 169.4 min, a difference of 96.9 min (P <0.0001) between the two methods. CONCLUSIONS: Capnography accurately identified all intratracheal feeding tube placements in this study. This study also shows that the use of capnography would significantly shorten the time needed for tube placement compared with a two-step radiologic method. Capnography should be considered for routine use when placing feeding tubes since it adds little time to the procedure and may improve patient safety.

Adult↗

Capnography alone is imperfect for endotracheal tube placement confirmation during emergency intubation.

This analysis primarily sought to determine the effectiveness of end-tidal capnography for tube placement confirmation during emergency airway management. Secondary objectives were validation of the rate of unanticipated esophageal placement during emergency intubation and quantification of the portion of intubations performed in patients with cardiac arrest where capnography is not recommended. The study was performed in two phases. For the primary objective, a meta-analysis was performed on all experimental capnography trials enrolling emergency populations. For the secondary objectives, inadvertent esophageal intubation and cardiac arrest rates were calculated from a large prospective multicenter observational study of emergency intubation cases. Data analysis included calculation of descriptive statistics, sensitivity, specificity, and confidence intervals (CI). Based on 2,192 intubations, a meta-analysis of previous capnography trials resulted in an aggregate sensitivity of 93% (95% CI 92-94%) and an aggregate specificity of 97% (CI 93-99%) for emergency tube placement confirmation. Thus, for emergency capnography use, the false-negative failure rate (tube in trachea but capnography reports esophagus) was 7% and the false-positive rate (tube in esophagus but capnography reports trachea) was 3%. This translates to potential harm for one patient in every 10 treated with capnographic confirmation alone (number needed to harm: 14 for false-negative, 33 for false-positive, and 10 for both). A further literature review demonstrated no sole method of tube placement confirmation is completely foolproof. Of 4,602 consecutive intubations reported to the National Emergency Airway Registry, 4% of emergency intubation attempts resulted in accidental esophageal intubation, and 10% occurred in nontraumatic cardiac arrest patients. During tracheal intubation of critically ill patients, it is concluded that the rate of accidental esophageal tube placement warrants continued improvement in emergency airway techniques. Misidentification of esophageal placement in the emergency setting may occur with capnography. Multiple methods of tube placement confirmation are superior to any single method because no single method has perfect accuracy.

Capnography↗

Microstream capnography improves patient monitoring during moderate sedation: a randomized, controlled trial.

BACKGROUND: Investigative efforts to improve monitoring during sedation for patients of all ages are part of a national agenda for patient safety. According to the Institute of Medicine, recent technological advances in patient monitoring have contributed to substantially decreased mortality for people receiving general anesthesia in operating room settings. Patient safety has not been similarly targeted for the several million children annually in the United States who receive moderate sedation without endotracheal intubation. Critical event analyses have documented that hypoxemia secondary to depressed respiratory activity is a principal risk factor for near misses and death in this population. Current guidelines for monitoring patient safety during moderate sedation in children call for continuous pulse oximetry and visual assessment, which may not detect alveolar hypoventilation until arterial oxygen desaturation has occurred. Microstream capnography may provide an "early warning system" by generating real-time waveforms of respiratory activity in nonintubated patients. OBJECTIVE: The aim of this study was to determine whether intervention based on capnography indications of alveolar hypoventilation reduces the incidence of arterial oxygen desaturation in nonintubated children receiving moderate sedation for nonsurgical procedures. PARTICIPANTS AND METHODS: We included 163 children undergoing 174 elective gastrointestinal procedures with moderate sedation in a pediatric endoscopy unit in a randomized, controlled trial. All of the patients received routine care, including 2-L supplemental oxygen via nasal cannula. Investigators, patients, and endoscopy staff were blinded to additional capnography monitoring. In the intervention arm, trained independent observers signaled to clinical staff if capnograms indicated alveolar hypoventilation for >15 seconds. In the control arm, observers signaled if capnograms indicated alveolar hypoventilation for >60 seconds. Endoscopy nurses responded to signals in both arms by encouraging patients to breathe deeply, even if routine patient monitoring did not indicate a change in respiratory status. OUTCOME MEASURES: Our primary outcome measure was patient arterial oxygen desaturation defined as a pulse oximetry reading of <95% for >5 seconds. Secondary outcome measures included documented assessments of abnormal ventilation, termination of the procedure secondary to concerns for patient safety, as well as other more rare adverse events including need for bag-mask ventilation, sedation reversal, or seizures. RESULTS: Children randomly assigned to the intervention arm were significantly less likely to experience arterial oxygen desaturation than children in the control arm. Two study patients had documented adverse events, with no procedures terminated for patient safety concerns. Intervention and control patients did not differ in baseline characteristics. Endoscopy staff documented poor ventilation in 3% of all procedures and no apnea. Capnography indicated alveolar hypoventilation during 56% of procedures and apnea during 24%. We found no change in magnitude or statistical significance of the intervention effect when we adjusted the analysis for age, sedative dose, or other covariates. CONCLUSIONS: The results of this controlled effectiveness trial support routine use of microstream capnography to detect alveolar hypoventilation and reduce hypoxemia during procedural sedation in children. In addition, capnography allowed early detection of arterial oxygen desaturation because of alveolar hypoventilation in the presence of supplemental oxygen. The current standard of care for monitoring all patients receiving sedation relies overtly on pulse oximetry, which does not measure ventilation. Most medical societies and regulatory organizations consider moderate sedation to be safe but also acknowledge serious associated risks, including suboptimal ventilation, airway obstruction, apnea, hypoxemia, hypoxia, and cardiopulmonary arrest. The results of this controlled trial suggest that microstream capnography improves the current standard of care for monitoring sedated children by allowing early detection of respiratory compromise, prompting intervention to minimize hypoxemia. Integrating capnography into patient monitoring protocols may ultimately improve the safety of nonintubated patients receiving moderate sedation.

Adolescent↗

The use of capnography for recognition of esophageal intubation in the neonatal intensive care unit.

Failure to recognize esophageal intubation can result in severe hypoxia and permanent neurologic injury. Capnography is a standard monitoring modality in the operating room but has not been utilized fully in other environments. We used capnography at the time of endotracheal intubation in the neonatal intensive care unit (NICU) to determine whether capnography could more quickly and accurately identify endotracheal tube position than other clinical indicators of endotracheal tube position. One hundred intubation episodes were studied in 55 neonates. Capnograms were obtained 15 and 120 sec following tube placement. Intubating personnel were blinded to the capnographic data and determined endotracheal tube location (trachea vs. esophagus) by clinical criteria only. The sensitivity and specificity of capnography and clinical examination for identification of tube position were analyzed, and the time required for establishing by clinical confirmation whether the tube was in the trachea or not was compared to that required for capnography. Forty of 100 intubation attempts resulted in esophageal intubation. Capnography correctly identified these errant tube placements in 39 of 40 instances and did so in 1.6 sec (SD +/- 2.4). Capnography failed to identify successful endotracheal intubation on only one occasion. Clinical indicators of tube position required 97.1 sec (SD +/- 92.6) to identify an esophageal intubation and failed to identify successful endotracheal intubation in 5 of 60 cases. We conclude that capnography is a valuable adjunct to clinical examination to demonstrate whether an endotracheal tube is placed correctly in the trachea of neonates in the NICU.

Blood Gas Monitoring, Transcutaneous↗

Initiation of capnography in a rural EMS system.

OBJECTIVE: Capnography is an effective means of monitoring cardiopulmonary resuscitation and managing endotracheal intubation. Numerous studies have validated its use in urban settings, but none have described its integration into a rural EMS system. The authors describe the process of integrating capnography training and use in Jackson County, West Virginia. METHODS: Two CO2SMOS capnography/ pulse oximeters were placed on the lead ambulances in Jackson County, West Virginia. Training in the operation and application of the equipment was provided, and providers used the monitors for a period of six months. A questionnaire was administered to assess their understanding of the equipment and its utility in prehospital care. Results were compiled and summarized. RESULTS: Ninety percent of the EMS providers subjectively felt that they understood capnography and its clinical application. They answered questions designed to test their understanding with 65% accuracy. CONCLUSION: In this model, capnography was successfully integrated into a rural EMS system. Reasonable proficiency in the use of the CO2SMOS monitor and an understanding of the information obtained were demonstrated, although the EMS providers tended to overestimate their actual understanding of the clinical application of capnography. This supports the need for ongoing, targeted education. The authors feel that capnography provides information that is uniquely relevant in rural EMS systems.

Allied Health Personnel↗

A survey of the use of capnography for the confirmation of correct placement of tracheal tubes in pediatric intensive care units in the UK.

BACKGROUND: The Royal College of Anaesthetists and the Association of Anaesthetists of Great Britain and Ireland recommend the use of capnography to ensure correct tracheal tube placement in the theater environment. Correct tracheal tube placement is essential in the care of ventilated patient, even more vital if the patient is critically ill, if serious morbidity and mortality is to be avoided. This survey examined the availability and use of capnography to confirm correct tracheal tube placement in the pediatric intensive care unit (PICU) in the UK. METHODS: A questionnaire concerning the use of capnography to confirm tracheal tube placement were sent to the lead clinicians of every PICU in the UK. RESULTS: A total of 19 replies were received from 26 (73%) consultants. One unit did not have a capnograph, 13 units (68%) had one capnograph for several beds and five units (26%) had one capnograph for each bed. Two units (11%) used capnography for every intubation and in 10 units (52%) the use of capnography was dependent on individual physician preference. Eight consultants (42%) felt that confirming tracheal tube placement by capnography should be mandatory after every intubation whether in the ward, A & E, or PICU. A total of 89% of PICUs have trainees with <1 year anesthetic experience compared with 65% of adult ICUs. CONCLUSIONS: The use of capnography to confirm tracheal tube placement may be even more important in the PICU than in adult ICU.

Auscultation↗

Can cardiac sonography and capnography be used independently and in combination to predict resuscitation outcomes?

OBJECTIVE: To measure the ability of cardiac sonography and capnography to predict survival of cardiac arrest patients in the emergency department (ED). METHODS: Nonconsecutive cardiac arrest patients prospectively underwent either cardiac ultrasonography alone or in conjunction with capnography during cardiopulmonary resuscitation at two community hospital EDs with emergency medicine residency programs. Cardiac ultrasonography was carried out using the subxiphoid view during pauses for central pulse evaluation and end-tidal carbon dioxide (ETCO(2)) levels were monitored by a mainstream capnograph. A post-resuscitation data collection form was completed by each of the participating clinicians in order to assess their impressions of the facility of performance and benefit of cardiac sonography during nontraumatic cardiac resuscitation. RESULTS: One hundred two patients were enrolled over a 12-month period. All patients underwent cardiac sonographic evaluation, ranging from one to five scans, during the cardiac resuscitation. Fifty-three patients also had capnography measurements recorded. The presence of sonographically identified cardiac activity at any point during the resuscitation was associated with survival to hospital admission, 11/41 or 27%, in contrast to those without cardiac activity, 2/61 or 3% (p < 0.001). Higher median ETCO(2) levels, 35 torr, were associated with improved chances of survival than the median ETCO(2) levels for nonsurvivors, 13.7 torr (p < 0.01). The multivariate logistic regression model, which evaluated the combination of cardiac ultrasonography and capnography, was able to correctly classify 92.4% of the subjects; however, of the two diagnostic tests, only capnography was a significant predictor of survival. The stepwise logistic regression model, summarized by the area under the receiver operator curve of 0.9, furthermore demonstrated that capnography is an outstanding predictor of survival. CONCLUSIONS: Both the sonographic detection of cardiac activity and ETCO(2) levels higher than 16 torr were significantly associated with survival from ED resuscitation; however, logistic regression analysis demonstrated that prediction of survival using capnography was not enhanced by the addition of cardiac sonography.

Capnography↗

Intermittent capnography during high-frequency jet ventilation for prolonged rigid bronchoscopy.

BACKGROUND: Gas exchange during high-frequency jet ventilation (HFJV) for prolonged rigid bronchoscopy (RBS) is usually monitored by arterial blood gas analysis. Capnography of expired gases during brief HFJV discontinuation may be a reliable and noninvasive supplemental method. Capnography can be performed either for single breaths or with respiratory rate (RR) reduced to 10 x min(-1). The aim of this study was to demonstrate that capnography during short periods of HFJV discontinuation represents a reliable measure of PaCO2 during prolonged RBS. METHODS: We prospectively investigated 100 consecutive patients (75 male and 25 female) undergoing HFJV for RBS. HFJV was delivered through the rigid bronchoscope at the following settings: working pressure 1.2 bar, rate 100 x min(-1), FIO2 0.99, t(i)/t(tot)0.6. The light guiding channel ending at the distal tip of the rigid bronchoscope was used for gas sampling. Capnograms were assessed at 5 min intervals and compared to PaCO2 from arterial blood samples drawn simultaneously. The accuracy of single breath CO2 sampling was compared with sampling at RR=10 x min(-1). RESULTS: Mean duration of RBS was 30+/-21 min. A significant correlation between capnography (PetCO2) and arterial blood gas analysis (PaCO2) was observed, being r=0.90 for the RR= 10 x min(-1) method and r=0.91 for the single breath method. Mean difference between PaCO2 and PetCO2 was 0.37+/-0.2 kPa throughout the entire study period. No significant differences between single breath sampling or sampling at RR=10 x min(-1) were observed. CONCLUSION: Capnography performed during short periods of HFJV discontinuation reliably and noninvasively reflects PaCO2 during prolonged endoscopic procedures. Capnography during HFJV for RBS may reduce the frequency of arterial blood gas sampling, the duration of unmonitored intervals and costs.

Adult↗

Predicting the need for hospitalization in acute childhood asthma using end-tidal capnography.

OBJECTIVE: To explore the utility of end-tidal capnography for predicting hospitalization in acute childhood asthma. DESIGN, SETTING, AND PARTICIPANTS: A prospective cohort study of a convenience sample of children 5 to 17 years of age presenting to a pediatric emergency department with an acute asthma exacerbation. Capnography was performed at baseline. The length of the plateau portion of the baseline capnograph waveform was measured in millimeters and divided by the respiratory rate at the time of the measurement to create a ratio. The sensitivity and specificity of the baseline capnography ratio for predicting hospitalization were assessed. MAIN OUTCOME MEASURES: Hospitalization versus discharge from the pediatric emergency department. RESULTS: Thirty-seven patients were enrolled. The hospitalized (n = 12) and discharged (n = 25) groups did not differ in terms of any demographic or baseline characteristics except for pulmonary score and the median baseline capnography ratio. The median ratio was 0.15. Ten (83.3%) of 12 of patients who were hospitalized had a baseline ratio less than 0.15 compared with 8 (32%) of 25 of patients who were discharged from pediatric emergency department (P < 0.05). Controlling for baseline asthma severity, the odds of being hospitalized if the baseline capnography ratio was less than 0.15 were 18.77 (95% confidence interval, 1.91-184.69). CONCLUSION: This pilot study suggests that baseline capnography may be useful as an objective effort-independent tool for identifying children with an asthma exacerbation who are at risk for hospitalization.

Acute Disease↗

Accuracy of physiologic dead space measurements in patients with acute respiratory distress syndrome using volumetric capnography: comparison with the metabolic monitor method.

BACKGROUND: Volumetric capnography is an alternative method of measuring expired carbon dioxide partial pressure (P(eCO2)) and physiologic dead-space-to-tidal-volume ratio (V(D)/V(T)) during mechanical ventilation. In this method, P(eCO2) is measured at the Y-adapter of the ventilator circuit, thus eliminating the effects of compression volume contamination and the need to apply a correction factor. We investigated the accuracy of volumetric capnography in measuring V(D)/V(T), compared to both uncorrected and corrected measurements, using a metabolic monitor in patients with acute respiratory distress syndrome (ARDS). METHODS: There were 90 measurements of V(D)/V(T) made in 23 patients with ARDS. The P(eCO2) was measured during a 5-min expired-gas collection period with a Delta-trac metabolic monitor, and was corrected for compression volume contamination using a standard formula. Simultaneous measurements of P(eCO2) and V(D)/V(T) were obtained using volumetric capnography. RESULTS: V(D)/V(T) measured by volumetric capnography was strongly correlated with both the uncorrected (r2 = 0.93, p < 0.0001) and corrected (r2 = 0.89, p < 0.0001) measurements of V(D)/V(T) made using the metabolic monitor technique. Measurements of V(D)/V(T) made with volumetric capnography had a bias of 0.02 and a precision of 0.05 when compared to the V(D)/V(T) corrected for estimated compression volume contamination. CONCLUSION: Volumetric capnography measurements of V(D)/V(T) in mechanically-ventilated patients with ARDS are as accurate as those obtained by metabolic monitor technique. .

Adult↗

Capnography application in acute and critical care.

The use of capnography has expanded over recent years. Currently, capnography is used in a variety of acute care settings. This article describes what capnography is and how it is used. The normal and abnormal capnogram or waveforms are described to assist in identifying various clinical situations. The multiplicity of clinical indications include detection of pulmonary embolism as well as malpositioned endotracheal/tracheal, gastric, and small bowel tubes. Capnography also provides clinicians with information regarding expiratory breathing patterns and assists in perfusion assessments such as those for cardiopulmonary resuscitation. Finally, case studies are provided to help the reader apply the concepts of capnography to a variety of acute care settings.

Acute Disease↗

Capnography in non-tracheally intubated emergency patients as an additional tool in pulse oximetry for prehospital monitoring of respiration.

UNLABELLED: Victims of minor trauma transported by paramedic-based rescue systems are usually monitored with pulse oximetry. Under the difficult surroundings of prehospital trauma care, pulse oximeters show considerable periods of malfunction. We tested the hypothesis that capnography is a good, easy to use tool for monitoring in nonintubated trauma victims. Seventy nonintubated trauma victims were included in this study. Vital variables and number and time of malfunctions were sampled for oximeter and capnometer recordings. Total number of alerts (63 versus 10), number of alerts per patient (3.3 [1.9] versus 0.3 [0.9]) (mean [SD]), total time of malfunction (191.5 [216.7] s versus 11.8 [40.2] s), time of malfunction per alarm (58.3 [71.4] s versus 5.5 [14.6] s), and the percentage of malfunction time during transport (13.2% [15.3%] versus 0.8% [2.8%]) differed significantly (P < 0.01) between oximetry and capnography. Although pulse oximetry is a standard method of monitoring in emergency care, we found capnography to be helpful as a monitoring device. We consequently recommend the use of capnography on transport as an additional monitoring tool to reduce periods lacking supervision of the vital variables. IMPLICATIONS: Capnography is a useful tool to improve respiratory monitoring in nonintubated trauma victims on emergency transport and an easy to use supplement to pulse oximetry.

Adult↗

[Method for measuring respiration in sleep: capnography for determining ventilation].

Ventilation serves the exchange of gases between the organism and the environment. Oxygen uptake and CO2 elimination are controlled by feedback loops, that keep fluctuations in arterial CO2 pressure (PaCO2) within narrow limits Disorders in the central regulation of breathing, or impairment of the respiratory apparatus, may result in a mismatch between metabolic CO2 production and ventilatory CO2, elimination and thus in fluctuations in the PaCO2: inappropriately increased ventilation (hyperventilation) causes hypocapnia, and reduced ventilation (hypoventilation) causes hypercapnia. In order to detect such disorders during sleep, PCO2 measurement is of great importance, but direct and continuous measurement of the PaCO2 is invasive and thus unsuitable in the clinical setting. An alternative is capnography, the continuous measurement of PCO2 in inhaled and exhaled air on the basis of ultrared light absorption. This paper reviews the method, its features and limitations, and the possibilities of improving capnography to better detect sleep-related breathing disorders. In addition, data obtained from 57 patients with predominantly normal lung function, but suspected sleep disordered breathing are presented. Simultaneous measurements of capnography PETCO2) and capillary PaCO2 revealed a PETCO2 difference of +0.63 +/- 3.3 (SD) Torr. PaCO2 (38.8 +/- 4.1 Torr) and PETCO2 (38.1 +/- 4.3 Torr) were not significantly different with a correlation coefficient of r = 0.68 (p < 0.001). Thus 46% of the variation in PETCO2 was explained by changes in PaCO2. Currently the literature contains few further data on capnography during sleep. It is concluded that, provided the limitations of the method are respected and comparison with the PETCO2 is made, capnography may be a useful, noninvasive and continuous measuring method for assessing ventilation during sleep in patients with suspected sleep related breathing disorders.

Adult↗

Detection of inadvertent airway intubation during gastric tube insertion: Capnography versus a colorimetric carbon dioxide detector.

BACKGROUND: In the medical intensive care unit at the University of Virginia Health System, capnography is used to detect end-tidal carbon dioxide to protect patients from inadvertent airway cannulation during placement of gastric tubes. OBJECTIVES: To compare the method in which capnography is used with a method in which a colorimetric carbon dioxide detector is used and to determine what variables affect accurate placement of gastric tubes. METHODS: A prospective convenience sample of 195 gastric tube insertions was studied in 130 adult patients in a medical intensive care unit. Standard insertions of gastric tubes (done with capnography) were simultaneously monitored by using a disposable colorimetric device, with a color change indicating the presence of carbon dioxide. RESULTS: Insertion variables included tube type (60% Salem sump tubes, 40% soft-bore feeding tubes), route of insertion (71% oral, 29% nasal), mechanical ventilation (81%), and decreased mental status (72%). Carbon dioxide was successfully detected with the colorimetric indicator (within seconds) in all insertions in which carbon dioxide was detected by capnography. When carbon dioxide was detected (27% of insertions), the tubes were withdrawn and reinserted. Carbon dioxide detection during tube placement was significantly associated with nasal insertions (P = .03) and spontaneously breathing/nonintubated status (P = .01) but not with mental status or tube type. CONCLUSIONS: A colorimetric device is as accurate as capnography for detecting carbon dioxide during placement of gastric tubes.

Adult↗

Use of capnography in critically ill adults.

A major responsibility of the critical care practitioner is to assure adequate ventilation of the critically ill patient. The traditionally used methods for evaluating ventilation, such as physical examination and measurement of vital signs, are indirect. The most commonly used direct method, measurement of arterial carbon dioxide tension, is invasive and intermittent. Capnography provides the critical care practitioner with a continuous, noninvasive, and accurate assessment of ventilation. To interpret capnographic data, the practitioner must have a clear understanding of normal and abnormal patterns of carbon dioxide elimination in the lung. We review relevant respiratory physiology as a basis for understanding the value of capnography. The technology on which capnography is based is described with emphasis on methods of gas sampling, limitations of capnography, and features available on currently marketed instruments. Representative capnograms are presented and the data interpreted to enable the practitioner to determine when capnography is an appropriate monitor for the critically ill adult.

Carbon Dioxide↗

Volumetric capnography as a bedside monitoring of thrombolysis in major pulmonary embolism.

OBJECTIVE: To describe the use of volumetric capnography, a plot of expired CO(2) concentration against expired volume, in monitoring fibrinolytic treatment of major pulmonary embolism. DESIGN AND SETTING: Two case reports in the emergency department of a teaching hospital. PATIENTS: Two conscious and spontaneously breathing patients (69- and 31-year-old women) with major pulmonary embolism requiring thrombolysis. Decision for thrombolysis was based on the association of right ventricular afterload on echocardiography, with respiratory failure and hypotension in the first patient, and dyspnea and hemodynamically stable parameters in the second one. INTERVENTIONS: Successive capnographic measurements were performed before, during, and after thrombolysis. Curves of volumetric capnography were obtained from a sidestream gas monitor with flow sensor and an arterial blood gas analysis for CO(2) partial pressure. MEASUREMENTS AND RESULTS: We calculated late deadspace fraction, previously suggested as the most effective capnographic parameter in the diagnosis of pulmonary embolism. Late deadspace fraction decreased in the two patients, respectively, from 64.4% to 1.1% and from 25.6% to 5.7% after thrombolysis, with a concomitant disappearance of right heart dysfunction signs on echocardiography. CONCLUSIONS: Volumetric capnography can monitor thrombolysis in major pulmonary embolism. Differences between volumetric capnography technology and the more traditional arterial to end-tidal CO(2) gradient are important to take into account for clinical application.

Adult↗

Capnography and depth of sedation during propofol sedation in children.

STUDY OBJECTIVE: To evaluate the relationship between continuous capnography and observed airway and respiratory adverse effects and the depth of sedation when using propofol for pediatric orthopedic procedures. METHODS: We administered propofol after opioid premedication in a prospective convenience sample of children undergoing orthopedic reduction in our emergency department (ED). All children received supplemental oxygen (1 L/minute by nasal cannula) and continuous capnography and had depth of sedation assessed every 2 minutes. Adverse airway or respiratory events and any associated interventions were recorded. RESULTS: Adverse airway or respiratory events with intervention occurred in 14 of the 125 enrolled children (11%; 95% confidence interval 4.0% to 14%): jaw thrust in 4, supplemental oxygen in 6, and bag-valve-mask ventilation in 4. All interventions required were brief (<30 seconds). Capnography detected apnea before clinical examination or pulse oximetry in all 5 occurrences and similarly first detected airway obstruction in 6 of the 10 occurrences. The median maximal modified Ramsay score was 6 (range 3 to 8), ie, deep sedation. CONCLUSION: When propofol is administered for ED deep sedation to facilitate pediatric orthopedic reduction, continuous capnography detects most airway and respiratory events leading to intervention before clinical examination or pulse oximetry.

Adolescent↗