Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Bacterial Adhesion”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Relevance of electrokinetic theory for "soft" particles to bacterial cells: implications for bacterial adhesion.

Bacterial cells and other biological particles carry charged macromolecules on their surface that form a "soft" ion-permeable layer. In this paper, we test the applicability of an electrokinetic theory for soft particles to characterize the electrophoretic mobility (EPM) and adhesion kinetics of bacterial cells. The theory allows the calculation of two parameters--the electrophoretic softness and the fixed charged density--that define the characteristics of the polyelectrolyte layer at the soft particle surface. The theory also allows the calculation of an outer-surface potential that may better predict the electrostatic interaction of soft particles with solid surfaces. To verify its relevance for bacterial cells, the theory was applied to EPM measurements of two well-characterized Escherichia coli K12 mutants having lipopolysaccharide (LPS) layers of different lengths and molecular compositions. Results showed that the obtained softness and fixed charge density were not directly related to the known characteristics of the LPS of the selected strains. Interaction energy profiles calculated from Derjaguin-Landau-Verwey-Overbeek (DLVO) theory were used to interpret bacterial deposition (adhesion) rates on a pure quartz surface. The outer surface potential failed to predict the low attachment efficiencies of the two bacterial strains. The lack of success in the application of the theory for soft particles to bacterial cells is attributed to chemical and physical heterogeneities of the polyelectrolyte layer at the cell surface.

Bacteria↗

CLA-1 and its splicing variant CLA-2 mediate bacterial adhesion and cytosolic bacterial invasion in mammalian cells.

CD36 and LIMPII analog 1, CLA-1, and its splicing variant, CLA-2 (SR-BI and SR-BII in rodents), are human high density lipoprotein receptors with an identical extracellular domain which binds a spectrum of ligands including bacterial cell wall components. In this study, CLA-1- and CLA-2-stably transfected HeLa and HEK293 cells demonstrated several-fold increases in the uptake of various bacteria over mock-transfected cells. All bacteria tested, including both Gram-negatives (Escherichia coli K12, K1 and Salmonella typhimurium) and Gram-positives (Staphylococcus aureus and Listeria monocytogenes), demonstrated various degrees of lower uptake in control cells. This result is consistent with the presence of high-density lipoprotein-receptor-independent bacterial uptake that is enhanced by CLA-1/CLA-2 overexpression. Bacterial lipopolysaccharides, lipoteichoic acid, and synthetic amphipathic helical peptides (L-37pA and D-37pA) competed with E. coli K12 for CLA-1 and CLA-2 binding. Transmission electron microscopy and confocal microscopy revealed cytosolic accumulation of bacteria in CLA-1/CLA-2-overexpressing HeLa cells. The antibiotic protection assay confirmed that E. coli K12 was able to survive and replicate intracellularly in CLA-1- and CLA-2-overexpressing HeLa, but both L-37pA and D-37pA prevented E. coli K12 invasion. Peritoneal macrophages isolated from SR-BI/BII-knockout mice demonstrated a 30% decrease in bacterial uptake when compared with macrophages from normal mice. Knockout macrophages were also characterized by decreased bacterial cytosolic invasion, ubiquitination, and proteasome mobilization while retaining bacterial lysosomal accumulation. These results indicate that, by facilitating bacterial adhesion and cytosolic invasion, CLA-1 and CLA-2 may play an important role in infection and sepsis.

Alternative Splicing↗

Structural polymorphism of bacterial adhesion pili.

Bacterial adhesion pili are designed to bind specifically and maintain attachment of bacteria to target cells. Uropathogenic P-pili are sufficiently mechanically resilient to resist the cleansing action of urine flow that removes most other bacteria. P-pili are 68 A in diameter and approximately 1 micron long, and are composed of approximately 1,000 copies of the principal structural protein, PapA. They are attached to the outer membrane by a minor structural protein, PapH and are terminated by an approximately 20 A diameter fibrillus composed of PapK, PapE and PapF, which presents the host-binding adhesin PapG. The amino-acid sequences of PapA, PapE, and PapF are similar, with highly conserved C-termini being responsible for binding to PapD, the periplasmic chaperone. Our three-dimensional reconstruction indicates that pili are formed by the tight winding of a much thinner structure. A structural transition allows the pilus to unravel without depolymerizing, producing a thin, extended structure five times the length of the original pilus.

Bacterial Adhesion↗

Modulation of host cell membrane fluidity: a novel mechanism for preventing bacterial adhesion.

Adhesion of bacterial enteropathogens to host mucosal surfaces is a critical primary step in the pathogenesis of diarrheal disease. We investigated the effects of altering the physical properties of eukaryotic cells on bacterial adhesion with the use of a series of three structurally dissimilar membrane fluidizers and several Escherichia coli as test strains. Lipid fluidity of the cell plasma membrane was measured by steady-state fluorescence anisotropy employing the probe 1-(4-trimethylammoniumphenyl)-6-phenyl-1,3, 5-hexatriene. There was a dose-dependent and reversible inhibition of bacterial adhesion with increasing membrane fluidity. Time course experiments indicated that increasing membrane fluidity during the early stages of bacterial adhesion was essential for inhibition of attachment. None of the fluidizers affected the viability of either eukaryotic or prokaryotic cells. These findings demonstrate, for the first time, that changes in plasma membrane physical properties of epithelial cells can prevent microbial adhesion. This also suggests that altering the membrane properties of host cells could form a basis for novel strategies to prevent bacterial adhesion during infection in vivo.

Bacterial Adhesion↗

The association of bacterial adhesion with dental caries.

Saliva adhesion of bacteria is a key event in oral biofilm formation. Here, we used partial least-squares (PLS) analysis to correlate adhesion of cariogenic (Streptococcus mutans Ingbritt) and commensal (Actinomyces naeslundii LY7) model bacteria, and their agglutinin and acidic proline-rich protein ligands, respectively, with high and low caries experiences in 38 children reflecting today's skewed caries distribution. Adhesion of S. mutans was among the factors correlating strongest with high caries experience when PLS modeled together with traditional factors (e.g., sugar intake, lactobacilli counts). Saliva phenotypes with high agglutinin levels and Db-s (an acidic PRP variant) coincided with both high caries experience and S. mutans adhesion. A. naeslundii adhesion correlated with low caries experience. Non-Db phenotypes (i.e., acidic PRP-1 and PRP-2 variants) coincided with both low caries experience and S. mutans, but high A. naeslundii, adhesion. Thus, bacterial adhesion may modulate susceptibility and resistance to dental caries.

Actinomyces↗

Intervention with bacterial adhesion by multivalent carbohydrates.

Bacterial adhesion is often a prelude to infection. In many cases, this process is governed by protein-carbohydrate interactions. Intervention at this early stage of infection is a conceptually highly attractive alternative to conventional antibiotics that are increasingly prone to resistance. The lack of high-affinity inhibitors of adhesion has proven to be a hurdle for further exploitation of this concept; however, new developments indicate a positive change. Structure-based design at the monovalent level and also evaluation of glycodendrimers and glycopolymers have yielded structures of high affinity. In addition to the development of inhibitors, topics of this review include available structural information of adhesion proteins, carbohydrate specificities of the various pathogens and their adhesion proteins. Other new developments aimed at affecting bacterial adhesion and the use of the adhesins for bacterial detection are also discussed.

Adhesins, Bacterial↗

Molecular determinants of bacterial adhesion monitored by atomic force microscopy.

Bacterial adhesion and the subsequent formation of biofilm are major concerns in biotechnology and medicine. The initial step in bacterial adhesion is the interaction of cells with a surface, a process governed by long-range forces, primarily van der Waals and electrostatic interactions. The precise manner in which the force of interaction is affected by cell surface components and by the physiochemical properties of materials is not well understood. Here, we show that atomic force microscopy can be used to analyze the initial events in bacterial adhesion with unprecedented resolution. Interactions between the cantilever tip and confluent monolayers of isogenic strains of Escherichia coli mutants exhibiting subtle differences in cell surface composition were measured. It was shown that the adhesion force is affected by the length of core lipopolysaccharide molecules on the E. coli cell surface and by the production of the capsular polysaccharide, colanic acid. Furthermore, by modifying the atomic force microscope tip we developed a method for determining whether bacteria are attracted or repelled by virtually any biomaterial of interest. This information will be critical for the design of materials that are resistant to bacterial adhesion.

Bacterial Adhesion↗

Bacterial adhesion to protein-coated hydrogels.

Extended wear soft contact lenses have been implicated in the increased occurrence of corneal bacterial infections. This research investigated the effects of polymer chemistry, water content, and pre-sorbed proteins upon the adherence of Pseudomonas aeruginosa to model hydrogels with chemistries similar to those of extended wear soft contact lenses. The hydrogels were exposed to washed suspensions of P. aeruginosa in a laminar flow cell. Albumin, fibrinogen, desialylated fibrinogen, or mucin were deposited on the hydrogels before exposure to the bacteria. Results showed that with or without protein pre-exposure, bacterial adhesion decreased as water content increased. In the presence of the sorbed protein, the number of adherent bacteria increased by about 45%, and all four proteins caused similar increases in adhesion. Bacterial adhesion was not significantly influenced by the presence of sialic acid residues in the pre-sorbed protein.

Animals↗

Stochastic modeling of bacterial adhesion: a two-step mechanism with linear adhesion rate.

Stochastic analysis of bacterial adhesion onto the surface of solid substrate is presented. Bacterial adhesion is assumed to occur in two steps: (i) a reversible adhesion between bacteria and solid surface; bacteria on the surface are weakly bound during this period, followed by (ii) an irreversible surface reaction which results in a strong binding force between bacteria and the surface; bacteria are considered to be in adhered form at this stage. The stochastic representation provides both the macroscopic and fluctuating information about the transient behavior of the phenomenon under consideration.

Bacterial Adhesion↗

Evaluation of bacterial adhesion of Streptococcus mutans on dental restorative materials.

Bacterial adhesion to the surface of composite resins and other dental restorative materials is an important parameter in the aetiology of secondary caries formation. The aim of the present study was to investigate the adhesion of a Streptococcus mutans strain (ATCC 25175) on the surface of different restorative materials. The test materials examined included three flowable composites (Filtek Flow, Tetric Flow, and Arabesk Flow), three microhybrid composites (Clearfil APX, Solitaire 2, and Z250), two glass-ionomers (Fuji IX, Fuji IX fast), a compomer (F2000), an ormocer (Admira), and a control reference material (tissue culture grade, surface treated polystyrene). The adhesion tests were carried out in 24-well plates. Quantitative turbidimetric measurements were finally performed in order to indirectly evaluate the amount of bacteria retained on the material surface after in vitro exposure to the bacteria suspension. Under these conditions, with the exception of the Admira ormocer and the Fuji IX fast glass ionomer, which were found to be more adhesive, all the other material surfaces showed a similar susceptibility to bacterial adhesion, exhibiting values not significantly different than the reference polystyrene control. Furthermore, the release of fluoride from some of the test surfaces did not appear capable to reduce early bacterial adhesion.

Adhesiveness↗

The effect of dissolved organic carbon on bacterial adhesion to conditioning films adsorbed on glass from natural seawater collected during different seasons.

Adhesion of three marine bacterial strains, i.e. Marinobacter hydrocarbonoclasticus, Psychrobacter sp. and Halomonas pacifica with different cell surface hydrophobicities was measured on glass in a stagnation point flow chamber. Prior to bacterial adhesion, the glass surface was conditioned for 1 h with natural seawater collected at different seasons in order to determine the effect of seawater composition on the conditioning film and bacterial adhesion to it. The presence of a conditioning film was demonstrated by an increase in water contact angle from 15 degrees on bare glass to 50 degrees on the conditioned glass, concurrent with an increase in the amount of adsorbed organic carbon and nitrogen, as measured by X-ray photoelectron spectroscopy. Multiple linear regression analysis on initial deposition rates, with as explanatory variables the temperature, salinity, pH and concentration of dissolved organic carbon (DOC) of the seawater at the time of collection, showed that the concentration of DOC was most strongly associated with the initial deposition rates of the three strains. Initial deposition rates of the two most hydrophilic strains to a conditioning film, increased with the concentration of DOC in the seawater, whereas the initial deposition rate of the most hydrophobic strain decreased with an increasing concentration of DOC.

Adhesiveness↗

[Bacterial adhesiveness and recurrent urinary infections in children].

Bacterial adhesivity test to epithelial cells in vitro was studied, in order to investigate whether urinary, and buccal cells, from children prone to recurrent urinary tract infections (UTI) are better adhered to by uropathogen Escherichia coli (E. coli), as compared to cells from control children, non-prone to recurrent UTI. Cells were withdrawn from 75 children, divided into 3 groups: with recurrent UTI without uropathy, with recurrent UTI and uropathy, and controls, without recurrent UTI and without uropathy. Values obtained showed that most of the children, prone or not to recurrent UTI, have cells allowing good adhesivity of the 2 uropathogen E. coli used and that there is no significant difference among these results and no relation with the 3 described groups. Bacterial adhesivity appears dependent on individual genetic variations of cell donors, presumably related to membrane receptors. Studies on in vitro bacterial adhesivity do not seem to be able to explain pathogenesis of recurrent UTI.

Adolescent↗

Bacterial adhesion to phosphorylcholine-based polymers with varying cationic charge and the effect of heparin pre-adsorption.

The steady increase in the use of medical implants and the associated rise of medical device infections has fuelled the need for the production of biomaterials with improved biocompatibility. 2-(methacryloyloxyethyl phosphorylcholine) (MPC) based coatings have been used to improve the biocompatibility of a number of different medical devices. Recent studies have investigated the use of a phosphorylcholine modified with cationic charge to encourage specific bio-interaction. Until now the affect of cationic charge incorporation in MPC copolymers on bacterial adhesion has not been investigated. This study attempts to address this by investigating the affect of charge on four different strains of bacteria commonly associated with medical device infections. In addition, the affect of pre-incubating these MPC-copolymers in heparin is also evaluated as this has previously been shown to improve biocompatibility and reduce bacterial adhesion. Bacterial adhesion was assessed by ATP bioluminescence and Scanning Electron Microscopy (SEM). Results suggest that bacterial adhesion generally increased with increasing cationic charge. When samples were however, pre-incubated with heparin a significant reduction in bacterial adhesion to the MPC-based samples was observed. The heparin remained bound and effective at reducing bacterial adhesion to the cationic MPC-based samples even after three weeks incubation in PBS. To conclude, the MPC-based cationic polymer coatings complexed with heparin may provide a promising solution to reduce medical device related infections.

Absorption↗

Mechanisms and clinical relevance of bacterial adhesion to polymers.

The mechanisms of bacterial adhesion to polymers with regard to their significance in the development of foreign-body infections are discussed. The morphological, physico-chemical and biological aspects are treated with special emphasis on the adhesion of coagulase-negative staphylococci to medical polymers. Strategies for the prevention of bacterial adhesion to biomaterials by developing antiadhesive polymers are given.

Anti-Bacterial Agents↗

Electrophoretic mobility and hydrophobicity as a measured to predict the initial steps of bacterial adhesion.

The relationship between physiochemical surface parameters and adhesion of bacterial cells to negatively charged polystyrene was studied. Cell surface hydrophobicity and electrokinetic potential were determined by contact angle measurement and electrophoresis, respectively. Both parameters influence cell adhesion. The effect of the electrokinetic potential increases with decreasing hydrophobicity. Cell surface characteristics determining adhesion are influenced by growth conditions. At high growth rates, bacterial cells tend to become more hydrophobic. This fact can be of ecological significance for controlling the spread of bacteria throughout the environment.

Bacteria↗

Bacterial adhesion to functionalized polyurethanes.

The effect of fibrinogen and high molecular weight kininogen on bacterial adhesion to functionalized polyurethanes was studied. Glass slides were coated with different polyurethanes, including Pellethane, sulfonated Pellethane, phosphonated Pellethane, a zwitterionic phosphonated polyurethane, and quaternized amine polyurethanes. The polymer-coated glass squares were exposed to radiolabelled S. aureus. When comparing adhesion to bare polyurethanes, it was found that adhesion was lowest on the phosphonated Pellethane and the zwitterionic phosphonated polyurethane while highest on the methyl quaternized polyurethanes. Fibrinogen-mediated adhesion was studied by first exposing the polymers to increasing concentrations of canine fibrinogen before incubating them with S. aureus. All the polymers except the quaternized amine polyurethanes exhibited at least ten-fold increases in bacterial adhesion as the fibrinogen treatment concentration was increased from 0.0 to 10.0 microg ml(-1). The quaternized amine polyurethanes maintained their relatively high amount of bacterial adhesion regardless of the fibrinogen concentration. The effect of two-chain high molecular weight kininogen (TCHMWK) on fibrinogen-mediated bacterial adhesion was assessed by exposing the polymers to 1.0 microg ml(-1) fibrinogen followed by two different concentrations of TCHMWK. Decreases in bacterial adhesion were observed on all the polymers except the quaternized amine polyurethanes, which again retained their relatively high amount of bacterial adhesion.

Animals↗

Importance of molecular details in predicting bacterial adhesion to hydrophobic surfaces.

Electrostatic and hydrophobic forces are generally recognized as important in bacterial adhesion. Current continuum models for these forces often wrongly predict measurements of bacterial adhesion forces. The hypothesis tested here is that even qualitative guides to bacterial adhesion often require more than continuum information about hydrophobic forces; they require knowledge about molecular details of the bacteria and substrate surface. In this study, four different strains of bacteria were adsorbed to silica surfaces hydrophobized with alkylsilanes. The thickness of the lipopolysaccharide layers varied on the different bacteria, and the lengths of the alkylsilane molecules were varied from experiment to experiment. Bacterial adhesion was assessed using column experiments and atomic force microscopy (AFM) experiments. Results show that hydrophobized surfaces have higher bacterial sticking coefficients and stronger adhesion forces than bare silica surfaces, as expected. However, adhesion decreased as the solution Debye length became longer than the alkylsilane, perhaps since the silane molecules could not "reach" the bacterial surface. Similarly, those bacteria with a long o-antigen layer had decreased adhesion, perhaps since the silane molecules could not reach surface-bound proteins on the bacteria. This study reveals that macroscopic measurements such as contact angle are not able to fully describe bacterial adhesion; rather, additional details such as the molecular length are required to predict adhesion.

Bacterial Adhesion↗

Bacterial adhesion in the pathogenesis of infective endocarditis. Effect of subinhibitory antibiotic concentrations on streptococcal adhesion in vitro and the development of endocarditis in rabbits.

Bacterial adhesion to the constituents of nonbacterial thrombotic endocarditis (NBTE) is important in the pathogenesis of endocarditis. Subinhibitory concentrations (subMIC) of some antibiotics decrease bacterial adhesion to epithelial cells in vitro. We utilized an in vitro assay system to study the effect of subMIC of various antibiotics on streptococcal adhesion to a fibrin-platelet matrix (simulating NBTE). The results were (a) bacterial adhesion of Streptococcus sanguis and Streptococcus faecalis to NBTE was significantly reduced by vancomycin, penicillin, tetracycline, chloramphenicol and streptomycin (P less than 0.01 vs. controls) but not rifampin or trimethoprimsulfametrole; (b) the effect was dose-dependent and increased with duration of exposure to antibiotic; (c) reduction in bacterial adhesion did not correlate with altered retention by hydrophobic-interaction chromatography. This reduction in adhesion correlated with a diminished capacity of subMIC exposed Streptococcus sanguis (1/4 vancomycin minimum inhibitory concentration (MIC) X 4 h) to produce endocarditis in vivo. After intravenous inoculation of 10(6) colony-forming units of preincubated organisms into rabbits with traumatized aortic valves, 6 of 22 developed endocarditis vs. 17 of 22 controls (P = 0.03). These results may be relevant to prophylaxis of endocarditis since exposure of bacteria to subMIC of various antibiotics may reduce bacterial adherence both, to mucosal surfaces, and to damaged cardiac valves.

Animals↗