Transverse aortic wall tears in infants after balloon angioplasty for aortic valve stenosis: relation of aortic wall damage to diameter of inflated angioplasty balloon and aortic lumen in seven necropsy cases.

Aortic wall tears resulting from rupture of dilating balloons in infants undergoing transluminal balloon angioplasty have not been previously recognized. A 2 day old infant had percutaneous transluminal balloon angioplasty to dilate a stenotic aortic valve, and after multiple balloon inflations the balloon burst. The infant died 2 days after undergoing transluminal balloon angioplasty and at necropsy a circumferential, transverse aortic wall tear was found. To test the hypothesis that rupture of appropriately sized balloons results in similar aortic wall tears, six unfixed, intact infant aortas were subjected to transluminal balloon angioplasty at necropsy: two infants had balloon rupture with inflated balloon diameter similar to that of the aorta, two had balloon rupture with an undersized balloon and two had dilation with an oversized balloon. Transverse wall tears occurred in aortas with similar aortic and balloon diameters; no aortic wall damage occurred with rupture of undersized balloons, and aortic rupture resulted from the use of oversized balloons. Thus, intimal-medial tears in the infant aorta may result from balloon bursting during angioplasty when aortic and inflated balloon diameters are similar.

Angioplasty, Balloon↗

Angioscopic evaluation of rotational atherectomy followed by additional balloon angioplasty versus balloon angioplasty alone in coronary artery disease: a prospective, randomized study.

OBJECTIVES: This study sought to compare, by angioscopy, the morphologic changes induced by rotational atherectomy, followed by additional angioplasty, with those observed after balloon angioplasty alone. BACKGROUND: Rotational atherectomy and balloon angioplasty act by different mechanisms, which could explain the difference in morphologic changes induced by these two techniques. METHODS: The study group included 50 patients with 50 lesions who were randomly assigned to undergo rotational atherectomy (n = 24) or balloon angioplasty (n = 26). Rotational atherectomy with a single burr (approximately equal to 70% of coronary diameter) was systematically followed by additional balloon angioplasty. Angioscopy was performed immediately after the procedure. Abnormal angioscopic findings were 1) flaps, graded from 1 to 3 (1 = intimal flap; 2 = flap protruding into < 50% of the lumen; 3 = flap protruding into > or = 50% of the lumen); 2) thrombi, graded from 1 to 3 (1 = flat deposits; 2 = protruding but nonocclusive thrombus; 3 = occlusive thrombus); 3) subintimal hemorrhage; 4) longitudinal dissection. The two groups were comparable for clinical and angiographic baseline data. RESULTS: On angioscopy, flaps were observed less frequently after rotational atherectomy followed by additional balloon angioplasty (8 [33%] of 24 lesions) than after balloon angioplasty alone (14 [54%] of 26 lesions, p = 0.08) and were also less severe (grade 1 in 6 lesions, grade 2 in 2 and grade 3 in none vs. grade 1 in 4 lesions, grade 2 in 5 and grade 3 in 5). Longitudinal dissections were also significantly less frequent: one versus six (p = 0.05). There was no difference in the incidence of angioscopic thrombi (p = 0.16) or subintimal hemorrhage (p = 0.15), but the power to detect a significant difference was low for these variables (37% and 26%, respectively). CONCLUSIONS: Rotational atherectomy followed by additional balloon angioplasty leads to fewer angioscopic dissections and a trend toward fewer intimal flaps than balloon angioplasty alone. However, our angioscopic differences did not lead to an outcome difference between the two groups.

Aged↗

Quantitative angiographic comparison of elastic recoil after coronary excimer laser-assisted balloon angioplasty and balloon angioplasty alone.

OBJECTIVES: Coronary lumen changes during and after excimer laser-assisted balloon angioplasty were measured by quantitative coronary angiography, and the results were compared with the effects of balloon angioplasty alone. BACKGROUND: Reduction of atherosclerotic tissue mass by laser ablation in the treatment of coronary artery disease may be more effective in enlarging the lumen than balloon angioplasty alone. METHODS: A series of 57 consecutive coronary lesions successfully treated by xenon chloride excimer laser-assisted balloon angioplasty were individually matched with 57 coronary artery lesions successfully treated by balloon angioplasty alone. The following variables were measured by quantitative coronary analysis: 1) ablation by laser, 2) stretch by balloon dilation, 3) elastic recoil, and 4) acute gain. RESULTS: Matching by stenosis location, reference diameter and minimal lumen diameter resulted in two comparable groups of 57 lesions with identical baseline stenosis characteristics. Minimal lumen diameter before excimer laser-assisted balloon angioplasty and balloon angioplasty alone were (mean +/- SD) 0.73 +/- 0.44 and 0.74 +/- 0.43 mm, respectively. Laser ablation significantly improved minimal lumen diameter by 0.56 +/- 0.44 mm before adjunctive balloon dilation. In both treatment groups, similar-sized balloon catheters (2.59 +/- 0.35 and 2.56 +/- 0.40 mm, respectively) were used. After laser-assisted balloon angioplasty, elastic recoil was 0.84 +/- 0.30 mm (32% of balloon size), which was identical to that after balloon angioplasty alone, namely, 0.82 +/- 0.32 mm (32%). Consequently, both interventions resulted in similar acute gains of 1.02 +/- 0.52 and 1.00 +/- 0.56 mm, respectively. Minimal lumen diameter after intervention was equal in both groups: 1.75 +/- 0.35 and 1.75 +/- 0.34 mm, respectively. The statistical power of this study in which a 25% difference in elastic recoil (0.2 mm) between groups was considered clinically important was 95%. CONCLUSIONS: In matched groups of successfully treated coronary lesions, xenon chloride excimer laser ablation did not reduce immediate elastic recoil after adjunctive balloon dilation or improve the final angiographic outcome compared with balloon angioplasty alone using similar-sized balloon catheters.

Angioplasty, Balloon, Coronary↗

Laser balloon angioplasty versus balloon angioplasty in normal rabbit iliac arteries.

Reduction of vascular recoil is an important goal of laser balloon angioplasty (LBA), wherein Nd:YAG laser radiation is delivered radially during balloon inflation. To define the acute and chronic effects of LBA on the normal arterial lumen in comparison with those of balloon angioplasty (BA), 36 New Zealand White male rabbits (3-4 kg) were subjected to LBA of an external iliac artery and to BA of the contralateral artery with two 1-minute balloon inflations. During LBA, which was performed during the second balloon inflation, either 300 (n = 26) or 176 (n = 10) J were delivered to achieve high and moderate laser doses, respectively, in different LBA groups. Angiography was performed pre- and post-LBA/BA and subsequently at intervals of either 1, 2, 7, 28, 48, or 223 days. Automated analysis of digitized images was used to measure lumen diameter. No instance of perforation or thrombosis occurred. LBA-treated arteries acutely showed an increase in mean diameter over baseline (+ .5 mm, P less than .01) and that of BA-treated arteries (+ .4 mm, P less than .01). While arteries treated with the high laser dose showed a loss of the initial gain in lumen diameter by 1 month, caused by both extravascular fibrosis of the thinwalled (less than 0.1 mm) artery and mild neointimal proliferation which were not reduced by daily administration of aspirin in seven rabbits, arteries treated with the moderate laser dose retained the increment in mean diameter at 1 month over that of BA-treated arteries (+ .5 mm, P less than .05). Thus, unlike BA, LBA increases luminal diameter acutely and, at a moderate laser dose, chronically.

Angioplasty, Balloon↗

Excimer laser angioplasty versus balloon angioplasty in functional and total coronary occlusions.

Registries of excimer laser coronary angioplasty have reported good results in the treatment of complex coronary artery disease, including total or subtotal coronary occlusions. One hundred three patients (103 lesions) with a functional or total coronary occlusion were included in a randomized trial (Amsterdam-Rotterdam [AMRO] trial, total of 308 patients), 49 patients were allocated to laser angioplasty and 54 patients to balloon angioplasty. The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomized segment during a 6-month follow-up period. The primary angiographic end point was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by an automated contour-detection algorithm. Laser angioplasty was followed by balloon angioplasty in all procedures. The angiographic success rate was 65% in patients treated with excimer laser-assisted balloon angioplasty compared with 61% in patients treated with balloon angioplasty alone. No deaths occurred. There were no significant differences between the laser angioplasty group and the balloon angioplasty group in the incidence of myocardial infarctions (1 patient vs 3, respectively, p = 0.36), coronary bypass surgery (4 patients vs 2, respectively, p = 0.34), repeat angioplasty (10 patients vs 8, respectively, p = 0.46) or primary clinical end point (15 patients vs 12, respectively, p = 0.34). The net gain in minimal lumen diameter and restenosis rate (>50% diameter stenosis at follow-up) were 0.81 +/- 0.74 mm and 66.7%, respectively, in patients treated with laser angioplasty compared with 1.04 +/- 0.68 mm and 48.5%, respectively, in patients treated with balloon angioplasty (p = 0.59 and p = 0.15, respectively). Excimer laser-assisted balloon angioplasty demonstrated no benefit over balloon angioplasty with respect to initial and long-term clinical and angiographic outcome in the treatment of patients with functional or total coronary occlusions of >10 mm in length.

Adult↗

[Balloon angioplasty].

Balloon angioplasty of the coronary arteries is about 20 years old and has become the main technique of myocardial revascularisation. It is performed under local anaesthetic by arterial puncture and some centres are already performing the procedures on an ambulatory basis. Optimally, the procedure should be performed in a well-equipped catheter laboratory with trained operators and experienced personnel. The most impressive results are obtained in single vessel disease. However, double and triple vessel disease may also be treated, especially in elderly, frail patients, in cases of high surgical risk or with a previous history of coronary bypass surgery. Balloon angioplasty has an important role in the treatment of acute myocardial infarction, either as an alternative or as a complement to thrombolytic therapy. The major limitations of this technique, in the absence of stenting, are the failure to pass chronic lesions, the occurrence of major complications in about 1% of cases, of acute occlusion in about 5% of cases, and, finally, of restenosis estimated between 30 and 50%, depending on the publication. In the general population, the success rate is over 95% with an immediate return to normal life and the possibility of repeating an angioplasty in cases of restenosis. Coronary stents are a major technical adjuvant to balloon angioplasty and the indications of their implantation have exceeded 50% of procedures in recent years.

Adult↗

Clinical events following excimer laser angioplasty or balloon angioplasty for complex coronary lesions: subanalysis of a randomised trial.

OBJECTIVES: To compare clinical outcome in patients with complex coronary lesions treated with either excimer laser coronary angioplasty (ELCA) or balloon angioplasty. PATIENTS AND DESIGN: 308 patients with stable angina and a coronary lesion of more than 10 mm in length were randomised to ELCA (151 patients, 158 lesions) or balloon angioplasty (157 patients, 167 lesions). The primary clinical end points were death, myocardial infarction, coronary bypass surgery, or repeated coronary angioplasty of the randomised segment during six months of follow up. Subanalysis was performed to identify a subgroup of patients with a beneficial clinical outcome following ELCA or balloon angioplasty. SETTING: Two university hospitals and one general hospital. RESULTS: There were no deaths. Myocardial infarction, coronary bypass surgery, and repeated angioplasty occurred in 4.6, 10.6, and 21.2%, respectively, of patients treated with ELCA compared with 5.7, 10.8, and 18.5%, respectively, of those treated with balloon angioplasty. ELCA did not yield a favourable clinical outcome in subgroups of patients with long (more than 20 mm) coronary lesions, calcified lesions, small diseased vessels (< or = 2.5 mm reference diameter), or total coronary occlusions. There was a worse clinical outcome in patients with tandem lesions treated with ELCA compared with balloon angioplasty (9/18 v 3/26 lesions; p = 0.01); while a trend towards an unfavourable clinical outcome was found in patients with vessels with a reference diameter of more than 2.5 mm (23/66 v 13/63 lesions, p = 0.07) and left circumflex coronary lesions (12/41 v 6/42 lesions, p = 0.08). CONCLUSIONS: The findings indicate a worse clinical outcome in patients with lesions of more than 10 mm treated with ELCA compared with balloon angioplasty who have tandem coronary lesions and in those with vessels with a reference diameter of more than 2.5 mm and left circumflex coronary lesions.

Aged↗

Randomised trial of excimer laser angioplasty versus balloon angioplasty for treatment of obstructive coronary artery disease.

BACKGROUND: Excimer laser coronary angioplasty is reported to give excellent procedural results for treatment of complex coronary lesions, but this method has not been compared with balloon angioplasty in a randomised trial. METHODS: Patients (n = 308) with stable angina and coronary lesions longer than 10 mm on visual assessment were included. 151 patients (158 lesions) were assigned randomly to laser angioplasty and 157 (167 lesions) to balloon angioplasty. The primary clinical endpoints were death, myocardial infarction, coronary bypass surgery, or repeat coronary angioplasty of the randomised segment during 6 months of follow-up. The primary angiographic endpoint was the minimal lumen diameter at follow-up in relation to the baseline value (net gain), as determined by quantitative coronary angiography. FINDINGS: Laser angioplasty was followed by balloon angioplasty in 98% of procedures. The angiographic success rate was 80% in patients treated with laser angioplasty compared with 79% in patients treated with balloon angioplasty. There were no deaths. Myocardial infarction, coronary bypass surgery, and repeat angioplasty occurred in 4.6%, 10.6%, and 21.2%, respectively, of the patients in the laser angioplasty group compared with 5.7%, 10.8%, and 18.5% of the balloon angioplasty group. Net mean (SD) gain in minimal lumen diameter was 0.40 (0.69) mm in patients treated with laser angioplasty and 0.48 (0.66) mm in those treated with balloon angioplasty (p = 0.34). The restenosis rate (> 50% diameter stenosis) was 51.6% in the laser angioplasty group versus 41.3% in the balloon angioplasty group (p = 0.13). INTERPRETATION: Excimer laser angioplasty followed by balloon angioplasty provides no benefit additional to balloon angioplasty alone with respect to the initial and long-term clinical and angiographic outcome in the treatment of obstructive coronary artery disease.

Adult↗

Intravascular ultrasonic comparisons of mechanisms of vasodilatation of cutting balloon angioplasty versus conventional balloon angioplasty.

Intimal hyperplasia after balloon dilatation may be related to the severity of vascular injury, and cutting balloon angioplasty (CBA) may reduce vascular injury. The present study investigated the mechanism of vasodilation by CBA. Intravascular ultrasound examination was performed before and after intervention in 40 lesions treated with CBA and in 25 lesions treated with conventional balloon angioplasty. Intravascular ultrasound measurements included the vessel area, luminal area, and plaque area. Vessel expansion was evaluated as the ratio of the postprocedural vessel area to that before intervention. The vessel area was 13.9 +/- 3.2 and 14.8 +/- 3.2 mm(2) after CBA versus conventional angioplasty, respectively, whereas the luminal area was 5.5 +/- 1.2 versus 5.7 +/- 1.2 mm(2) and the plaque area was 8.5 +/- 2.7 versus 9.1 +/- 2.2 mm(2), respectively. The vessel area was smaller and the plaque area significantly smaller after CBA. Vessel expansion accounted for 45% of luminal enlargement, and plaque compression or shift accounted for 55% after CBA. After conventional angioplasty, vessel expansion accounted for 67%, and plaque compression or shift for 33% of luminal enlargement. The vessel expansion ratio was significantly smaller after CBA than after conventional angioplasty (1.05 vs 1.22, p <0.05). These findings suggest that the predominant mechanism of dilatation after CBA is plaque compression or shift rather than vessel expansion, unlike conventional angioplasty.

Angioplasty, Balloon, Coronary↗

Cutting balloon angioplasty vs. conventional balloon angioplasty in patients receiving intracoronary brachytherapy for the treatment of in-stent restenosis.

The objective of this study was to evaluate the safety and efficacy of cutting balloon angioplasty (CBA) for the treatment of in-stent restenosis prior to intracoronary brachytherapy (ICB). Cutting balloon angioplasty may reduce the incidence of uncontrolled dissection requiring adjunctive stenting and may limit "melon seeding" and geographic miss in patients with in-stent restenosis who are subsequently treated with ICB. We performed a retrospective case-control analysis of 134 consecutive patients with in-stent restenosis who were treated with ICB preceded by either CBA or conventional balloon angioplasty. We identified 44 patients who underwent CBA and ICB, and 90 control patients who underwent conventional percutaneous transluminal coronary angioplasty (PTCA) and ICB for the treatment of in-stent restenosis. Adjunctive coronary stenting was performed in 13 patients (29.5%) in the CBA/ICB group and 41 patients (45.6%; P < 0.001) in the PTCA/ICB group. There was no difference in the injury length or active treatment (ICB) length. The procedural and angiographic success rates were similar in both groups. There were no statistically significant differences in the incidence of death, myocardial infarction, recurrent angina pectoris, subsequent target lumen revascularization, or the composite endpoint of all four clinical outcomes (P > 0.05). Despite sound theoretical reasons why CBA may be better than conventional balloon angioplasty for treatment of in-stent restenosis with ICB, and despite a reduction in the need for adjunctive coronary stenting, we were unable to identify differences in clinical outcome.

Aged↗

Excimer laser angioplasty vs. balloon angioplasty in saphenous vein bypass grafts: quantitative angiographic comparison of matched lesions.

Technologies which ablate or debulk tissue may result in better angiographic outcomes by altering the elastic properties of the vessel wall. Accordingly, the procedural outcomes of 88 vein graft lesions treated by either excimer laser angioplasty with adjunct balloon angioplasty (PELCA + PTCA, n = 44) (Spectranetics CVX-300, 1.4-, 1.7-, or 2.0-MM catheters) or balloon angioplasty alone (PTCA, n = 44) were analyzed by quantitative angiography (Cardiac Measurement System). Lesions were individually matched for vessel position, reference diameter (RD), and minimal luminal diameter (MLD). Matching was deemed adequate as the preprocedure MLD (PELCA + PTCA, 1.14 +/- 0.48 mm; PTCA, 1.20 +/- 0.47 mm) and RD (PELCA + PTCA, 3.23 +/- 0.56 mm; PTCA, 3.25 +/- 0.57 mm) were not significantly different. There were also no significant differences between PELCA + PTCA- and PTCA-treated lesions with respect to patient age, graft age, lesion length, symmetry, and plaque area. Balloon diameter at maximal inflation was 2.77 +/- 0.55 mm (PELCA + PTCA group) and 2.84 +/- 0.59 mm (PTCA group), P = NS. Final MLD postprocedure was 2.17 +/- 0.54 mm and 2.19 +/- 0.55 mm for PELCA + PTCA- and PTCA-treated lesions (P = NS), respectively. Vessel stretch [(balloon diameter - MLD pre)/RD], elastic recoil [(balloon diameter - MLD post)/RD], and acute gain [(MLD post - MLD pre)/RD] were calculated and normalized for vessel size (RD). Vessel stretch (PELCA + PTCA, 0.60 +/- 0.22; PTCA, 0.59 +/- 0.24; P = NS), elastic recoil (PELCA + PTCA, 0.28 +/- 0.18; PTCA, 0.26 +/- 0.16), and acute gain (PELCA + PTCA, 0.34 +/- 0.24; PTCA, 0.31 +/- 0.23; P = NS) were not significantly different between the two treatment groups. In a matched population of successfully treated vein graft lesions, PELCA + PTCA did not reduce elastic recoil or improve immediate angiographic outcome, as compared with PTCA alone.

Adult↗

Modulation by beta-aminopropionitrile of vessel luminal narrowing and structural abnormalities in arterial wall collagen in a rabbit model of conventional balloon angioplasty versus laser balloon angioplasty.

This study was designed to assess the potential relationship between the late loss of angiographic luminal diameter and biochemical abnormalities of arterial wall collagen in rabbits subjected to angioplasty, and to test the hypothesis that beta-aminopropionitrile (beta APN), an inhibitor of lysyl oxidase, would inhibit such changes when administered orally for 1 mo after angioplasty. Endovascular injury was induced in rabbit iliac arteries by ipsilateral balloon angioplasty (BA) and by contralateral balloon angioplasty accompanied by exposure to continuous wave neodymium: yttrium aluminum garnet laser radiation (LBA). Computer measurement of angiographic luminal diameter demonstrated significant vessel narrowing at 1 and 6 mo after both procedures. By quantitative histology, the majority of the 1-mo loss in angiographic diameter could not be attributed to neointimal thickening. Analysis of collagen cross-linking by HPLC in collagen obtained from the LBA-injured segments of the arteries 1 mo after angioplasty revealed a significant increase, relative to values from uninjured arteries (P < 0.05), in the difunctional cross-link dihydroxylysinonorleucine (DHLNL). 6 mo after angioplasty, the content of hydroxypyridinium, the trifunctional maturational product of DHLNL, was significantly elevated in both BA- and LBA-treated arteries compared with values from uninjured arteries (P < 0.05). In animals administered beta APN, luminal narrowing at 1 mo, compared with controls, was attenuated (P < 0.01) and DHLNL content was decreased (P < 0.05) in arteries subjected to LBA, but not in arteries subjected to BA. The results suggest that lathyrogenic agents may be efficacious in favorably modulating LBA-induced alterations in vessel diameter and mural connective tissue.

Aminopropionitrile↗

[Long-term assessment of clinical parameters in patients with coronary heart disease after balloon angioplasty and stenting balloon angioplasty].

The aim of this study was to assess clinical parameters in patients with coronary heart disease (CHD) in the late period after balloon coronary angioplasty (BCA) and intracoronary stenting (ICS). The study included 104 patients who underwent repeated coronary angiography (CA) 2-10 months after successful coronary angioplasty. Clinical parameters were analyzed in 2 groups comparable at the moment of its performance in terms of major clinical characteristics. Group 1 comprised 51 patients following BCA and group 2 included 53 patients after ICS. Six months after the first procedure, repeated coronary angioplasty was performed in 19 (37.2%) and 6 (9.4%) patients after BCA and ICS, respectively (p < 0.05). Recurrent angina pectoris was observed in 42 patients from group 1 and in 25 ones from group 2, which was 82.3 and 47.2%, respectively (p < 0.05). Control CA revealed restenosis of the dilated artery in 22 (43.1%) of the 51 patients of group 1 and in 12 (22.6%) of the 53 patients of group 2. There were no differences between the groups in late postoperative bicycle ergometric and 24-hour ECG monitoring findings. The findings have led to the conclusion that implantation of a stent into the coronary artery greatly prolongs the antiischemic effect of coronary angioplasty and reduces a need for repeated endovascular intervention, which appears as lower incidence rates of restenosis and recurrent angina as compared to routine balloon angioplasty.

Adult↗

Angiographic risk factors of luminal narrowing after coronary balloon angioplasty using balloon measurements to reflect stretch and elastic recoil at the dilation site. The CARPORT Study Group.

Because many ongoing clinical restenosis prevention trials are using quantitative angiography to assess whether a drug is capable of reducing the amount of intimal hyperplasia, quantitative angiographic risk factors for angiographic luminal narrowing after balloon angioplasty were determined, including stretch and elastic recoil at the dilatation site. Quantitative analysis was performed on 666 lesions in 575 patients during angioplasty and at 6-month follow-up. Stretch was defined as balloon diameter minus minimal luminal diameter (MLD) before angioplasty/reference diameter, and recoil as balloon diameter minus MLD after angioplasty/reference diameter. Multivariate analysis was used to yield independent risk factors for luminal narrowing at follow-up. Predictors of absolute change in MLD were (1) relative gain at angioplasty (gain in millimeters normalized for reference diameter) and (2) lesion length. To allow risk stratification, logistic regression analysis was applied using the decrease in MLD as a binary outcome variable. A decrease in MLD at follow-up of greater than or equal to 0.72 mm was considered significant. Variables retained in the model were: relative gain greater than 0.3 mm (rate ratio 2.9), relative gain 0.2 to 0.3 (rate ratio 2.1), stenosis length greater than or equal to 6.8 (rate ratio 1.7), and thrombus after angioplasty (rate ratio 2.6). Although stretch was significantly related to luminal narrowing at univariate analysis, it was not retained in the multivariate models. A large gain in lumen diameter at angioplasty, dilation of long lesions, and angiographically determined thrombus after angioplasty were found to be accompanied by more severe luminal narrowing at follow-up.

Adult↗

Promising efficacy of primary gradual and prolonged balloon angioplasty in small coronary arteries: a randomized comparison with cutting balloon angioplasty and conventional balloon angioplasty.

BACKGROUND: Small vessel size represents a critical risk factor for an adverse outcome after both conventional balloon angioplasty (POBA) and stenting. Gradual and prolonged balloon angioplasty (GPBA) has been shown to cause less arterial trauma, which results in higher procedural success rates and fewer in-hospital complications than POBA. The aim of this study was to assess the clinical and angiographic benefits of primary GPBA with a perfusion balloon in small coronary arteries, as compared with cutting balloon angioplasty (CBA) and POBA. METHODS: A total of 263 patients with symptoms and reference diameters <3.0 mm were randomly assigned to undergo GPBA (n = 85), CBA (n = 88), or POBA (n = 90). The cumulative inflation time must be >10 minutes in GPBA. Crossover to stent was allowed for inadequate results. Follow-up angiography was performed after 6 months. The primary end point was angiographic restenosis at follow-up. RESULTS: Compared with POBA, GPBA resulted in a lower final residual diameter stenosis (27.3% vs 34.2%, P =.01) and decreased the need for stent placement (8.0% vs 22.2%, P =.031). At follow-up, the restenosis rates were lower with GPBA (31.3%, P =.034) and CBA (32.9%, P =.059) than POBA (50.6%). Target lesion revascularization was less frequently needed with GPBA (20.5%, P =.043) and CBA (20.0%, P =.033) than POBA (37.6%). Additionally, the event-free survival rate was higher with GPBA (77.1%, P =.033) and CBA (76.4%, P =.047) than POBA (58.8%). CONCLUSIONS: In small coronary arteries, both GPBA and CBA resulted in favorable angiographic and clinical outcomes. With a lower restenosis rate and target lesion revascularization rate, GPBA may be a superior strategy for small vessels compared with POBA.

Aged↗

Cutting balloon angioplasty is superior to balloon angioplasty or stent implantation for small coronary artery disease.

The aim of this study is to demonstrate initial results and long-term outcomes of patients after receiving cutting balloon angioplasty (CBA), balloon angioplasty (BA), or stenting for small vessel diseases. We studied a total of 327 lesions of small coronary disease treated either by CBA (n=87), BA (n=130), or stenting (n=110) in two affiliated institutes. A small coronary artery was defined as a reference vessel <2.5 mm using quantitative coronary angiography (QCA). Angiographic restenosis was encountered in 31% of the CBA, 46.5% of the BA, and 43.9% of the stent (p=0.048). Major adverse cardiac events (death, myocardial infarction, and target lesion revascularization) at follow-up were significantly lower in the CBA compared to other groups (CBA, 20.3%; BA, 37.3%; stent, 33.3%; p=0.036). The CBA procedure provided superior angiographic and clinical outcomes to the stenting or BA. The CBA may be a cost-effective and reasonable approach for the treatment of lesions in small coronary diseases.

Aged↗

Comparison of pulsed laser-assisted angioplasty and balloon angioplasty in femoropopliteal artery occlusions.

The authors performed a prospective, comparative study of 96 patients (age, 41-87 years) with femoropopliteal artery occlusions. Laser-assisted angioplasty was performed in 64 patients with 9- and 7-F over-the-wire multifiber catheters. Supplemental balloon dilation was performed after laser angioplasty. Thirty-two patients underwent excimer laser angioplasty (ELA), and 32 underwent pulsed dye laser angioplasty (DLA). The remaining 32 patients underwent conventional balloon angioplasty (BA). The length of occlusions was 3-10 cm (mean, 6.3 cm). Lesion characteristics in the three patient groups were similar. Technical success rates were 84% for ELA, 78% for pulsed DLA, and 81% for conventional BA. The 1-year clinical success rate was 69% (22 of 32 patients) in the ELA group, 63% (20 of 32 patients) in the pulsed DLA group, and 66% (21 of 32 patients) in the BA group (differences were not significant). Laser-assisted angioplasty with multifiber catheters in femoropopliteal artery occlusions did not help improve the technical success rate and 1-year clinical success rate when compared with those of conventional BA.

Adult↗

Evaluation of the long-term functional outcome assessed by myocardial perfusion scintigraphy following excimer laser angioplasty compared to balloon angioplasty in longer coronary lesions.

OBJECTIVES: Evaluation of the long-term functional outcome assessed by exercise myocardial perfusion imaging following excimer laser angioplasty compared to balloon angioplasty in coronary lesions > 10 mm in length. BACKGROUND: Previous randomized studies evaluating the effect of coronary interventions mainly focused on the long-term clinical and angiographic outcome. The functional outcome, assessed by myocardial perfusion scintigraphy, has not been evaluated in a randomized setting. METHODS: A total of 308 patients with stable angina and a longer coronary lesion (> 10 mm) were randomized to excimer laser angioplasty or balloon angioplasty. A 99mTechnetium-2-methoxy isobutyl isonitrile (MIBI) single-photon emission computed tomography (SPECT) study was performed in 139 patients before the initial angioplasty procedure and at 6 months follow-up (73 patients in the laser group versus 66 patients in the balloon group, respectively). Exercise tolerance at follow-up was compared to baseline values by means of exercise duration and double product at peak exercise. Myocardial perfusion of the randomized vascular bed was assessed semi-quantitatively on the MIBI SPECT images. The reversible defects were graded as mild, moderate or severe. Myocardial perfusion at follow-up was expressed as a percentage reduction in incidence and grading of the reversible defects compared to baseline values. RESULTS: Forty-four (61%) patients assigned to laser angioplasty were asymptomatic at 6 months follow-up compared to 34 (52%) patients assigned to balloon angioplasty (p = NS). Improvement in exercise duration and double product were 0.7 +/- 2.1 min and 4.3 +/- 6.2 min/mmHg/l,000, respectively, in the laser group, versus 0.3 +/- 2.5 min and 3.1 +/- 5.5 min/mmHg/1,000, respectively, in the balloon group (both p = NS). The percentage reduction of reversible defects was 23% in patients assigned to laser angioplasty vs. 29% in patients assigned to balloon angioplasty (Relative risk [RR]: 0.79, 95% confidence interval [CI]: 0.40-1.57; p = 0.50). The mild, moderate and severe reversible defects improved in 44.4, 63.6 and 66.6%, respectively, in the laser angioplasty group vs. 66.6, 53.8 and 90%, respectively, in the balloon angioplasty group. None of the comparisons were significantly different. CONCLUSION: Excimer laser angioplasty compared to balloon angioplasty in coronary lesions > 10 mm in length yields a similar long-term functional outcome assessed by anginal status, exercise tolerance and myocardial perfusion.

Adult↗