Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ATMOSPHERIC PRESSURE”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 recordsLinked to original sources

Comparison of electrospray, atmospheric pressure chemical ionization, and atmospheric pressure photoionization in the identification of apomorphine, dobutamine, and entacapone phase II metabolites in biological samples.

The applicability of different ionization techniques, electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI), and a novel atmospheric pressure photoionization (APPI), were tested for the identification of the phase II metabolites of apomorphine, dobutamine, and entacapone in rat urine and in vitro incubation mixtures (rat hepatocytes and human liver microsomes). ESI proved to be the most suitable ionization method; it enabled detection of 22 conjugates, whereas APCI and APPI showed only 12 and 14 conjugates, respectively. Methyl conjugates were detected with all ionization methods. Glucuronide conjugates were ionized most efficiently with ESI. Only some of the glucuronides detected with ESI were detected with APCI and APPI. Sulfate conjugates were detected only with ESI. MS/MS experiments showed that the site of glucuronidation or sulfation could not be determined, since the primary cleavage was a loss of the conjugate group (glucuronic acid or SO3), and no site-characteristic product ions were formed. However, it may be possible to determine the site of methylation, since methylated products are more stable than glucuronides or sulfates. Furthermore, the loss of CH3 is not necessarily the primary cleavage, and site characteristic products may be formed. Identification and comparison of conjugates formed from the current model drugs were successfully analyzed in different biological specimens of common interest to biomedical research. A fairly good relation was obtained between the data from in vivo and in vitro models of drug metabolism.

Animals↗

Liquid chromatography/mass spectrometry in anabolic steroid analysis--optimization and comparison of three ionization techniques: electrospray ionization, atmospheric pressure chemical ionization and atmospheric pressure photoionization.

The applicability of liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the detection of the free anabolic steroid fraction in human urine was examined. Electrospray ionization (ESI), atmospheric pressure chemical ionization and atmospheric pressure photoionization methods were optimized regarding eluent composition, ion source parameters and fragmentation. The methods were compared with respect to specificity and detection limit. Although all methods proved suitable, LC/ESI-MS/MS with a methanol-water gradient including 5 mM ammonium acetate and 0.01% acetic acid was found best for the purpose. Multiple reaction monitoring allowed the determination of steroids in urine at low nanogram per milliliter levels. LC/MS/MS exhibited high sensitivity and specificity for the detection of free steroids and may be a suitable technique for screening for the abuse of anabolic steroids in sports.

Anabolic Agents↗

Surface-assisted reduction of aniline oligomers, N-phenyl-1,4-phenylenediimine and thionin in atmospheric pressure chemical ionization and atmospheric pressure photoionization.

Reduction of the oligomers formed from on-line electropolymerization of aniline, the compound N-phenyl-1,4-phenylenediimine, and the thiazine dye thionin was observed in both an atmospheric pressure chemical ionization and an atmospheric pressure photoionization source. The reduction, which alters the mass of these analytes by 2 Da, was shown to occur by means of a surface-assisted process which involves reactive species, possibly hydrogen radicals, generated from protic solvents in the ionization plasma. Reduction was minimized by limiting protic solvents, by using a high heated nebulizer temperature, and by using a clean, heated nebulizer probe liner. The expected generality of this reduction process, and the possibility of similar reduction processes in other plasma ionization sources are discussed in relation to the use of these ion sources for on-line electrochemistry/mass spectrometry experiments.

Journal Article↗

Effect of eluent on the ionization efficiency of flavonoids by ion spray, atmospheric pressure chemical ionization, and atmospheric pressure photoionization mass spectrometry.

The effect of nine different eluent compositions on the ionization efficiency of five flavonoids was studied using ion spray (IS), atmospheric pressure chemical ionization (APCI), and the novel atmospheric pressure photoionization (APPI), in positive and negative ion modes. The eluent composition had a great effect on the ionization efficiency, and the optimal ionization conditions were achieved in positive ion IS and APCI using 0.4% formic acid (pH 2.3) as a buffer, and in negative ion IS and APCI using ammonium acetate buffer adjusted to pH 4.0. For APPI work, the eluent of choice appeared to be a mixture of organic solvent and 5 mM aqueous ammonium acetate. The limits of detection (LODs) were determined in scan mode for the analytes by liquid chromatography/mass spectrometry using IS, APCI and APPI interfaces. The results show that negative ion IS with an eluent system consisting of acidic ammonium acetate buffer provides the best conditions for detection of flavonoids in mass spectrometry mode, their LODs being between 0.8 and 13 microM for an injection volume of 20 microl.

Journal Article↗

Capillary column supercritical fluid chromatography-atmospheric pressure ionisation mass spectrometry interface performance of atmospheric pressure chemical ionisation and electrospray ionisation.

A supercritical fluid chromatography interface probe for atmospheric pressure ionisation mass spectrometry (API-MS) with the advantage of convenient switch between ionisation modes [atmospheric pressure chemical ionisation (APCI) and electrospray ionisation (ESI)] has recently been reported [P.J.R. Sjöberg, K.E. Markides, J. Chromatogr. A, 785 (1997) 101]. In order to obtain a stable ion signal and a low minimum detectable quantity, the design of the spray devise has to be optimised. For easy optimisation in the APCI mode, the corona needle was mounted directly on the interface probe. To compensate for the adiabatic cooling of the expanding mobile phase in the APCI mode, a heated region around the restrictor tip was used. In comparison, ESI required no additional heat, which might also prevent fragmentation for thermolabile compounds. As the mobile phase used was neat CO2, a low flow of make-up liquid was utilised in the ESI mode for transfer of the analytes from the expanding CO2 gas to the liquid phase before ionisation. The low make-up liquid flow in the ESI mode was sufficient for preventing the restrictor from becoming blocked. Factors that influence the ion signal intensity and stability have been studied. In APCI mode, corona needle position, nebuliser gas flow and gas additives were studied and in ESI mode, spray capillary assembly dimension and position, liquid flow-rate and composition were studied. The achievable detection limits were in the 50-0.1 pg (i.e., 290 fmol-140 amol) range. The detection limit in APCI mode was improved by a factor of about 20-25 compared to an earlier design [L.N. Tyrefors, R.X. Moulder, K.E. Markides, Anal. Chem. 65 (1993) 2835].

Atmospheric Pressure↗

[Dynamics of atmospheric pressure under the maxillary complete denture. 1. Relations between the denture retention and the atmospheric pressure].

Dynamics of atmospheric pressure under the maxillary complete denture, and their relations with the denture retention influenced by the factors such as the denture seating force, the saliva viscosity and the postdamming, were investigated on the simulation models. The following results were obtained. 1. The atmospheric pressure under the denture became higher than the external one by the denture insertion, and increased during the denture seating, and decreased by the removing force of denture and furthermore became lower than external one by continuous application of its force, and at all became equal to the external one when the denture separated from the basal seat. 2. Greater seating force brought about greater positive pressure and less negative pressure. 3. Higher viscosity of saliva and the postdamming brought about greater positive and negative pressures. 4. Both of greater seating force and higher viscosity of saliva brought about greater retentive force. 5. The postdamming was useful for the maxillary posterior border seal. 6. The atmospheric pressure under the denture base seems not to relate directly to the maxillary denture retention in the static condition but to reveal the status of peripheral seal.

Atmospheric Pressure↗

Atmospheric pressure chemical ionization of fluorinated phenols in atmospheric pressure chemical ionization mass spectrometry, tandem mass spectrometry, and ion mobility spectrometry.

Atmospheric pressure chemical ionization (APCI)-mass spectrometry (MS) for fluorinated phenols (C6H5-xFxOH Where x = 0-5) in nitrogen with Cl- as the reagent ion yielded product ions of M Cl- through ion associations or (M-H)- through proton abstractions. Proton abstraction was controllable by potentials on the orifice and first lens, suggesting that some proton abstraction occurs through collision induced dissociation (CID) in the interface region. This was proven using CID of adduct ions (M Cl-) with Q2 studies where adduct ions were dissociated to Cl- or proton abstracted to (M-H)-. The extent of proton abstraction depended upon ion energy and structure in order of calculated acidities: pentafluorophenol > tetrafluorophenol > trifluorophenol > difluorophenol. Little or no proton abstraction occurred for fluorophenol, phenol, or benzyl alcohol analogs. Ion mobility spectrometry was used to determine if proton abstraction reactions passed through an adduct intermediate with thermalized ions and mobility spectra for all chemicals were obtained from 25 to 200 degrees C. Proton abstraction from M Cl- was not observed at any temperature for phenol, monofluorophenol, or difluorophenol. Mobility spectra for trifluorophenol revealed the kinetic transformations to (M-H)- either from M Cl- or from M2 Cl- directly. Proton abstraction was the predominant reaction for tetra- and penta-fluorophenols. Consequently, the evidence suggests that proton abstraction occurs from an adduct ion where the reaction barrier is reduced with increasing acidity of the O-H bond in C6H5-xFxOH.

Atmospheric Pressure↗

Characterization of triglycerides in vegetable oils by silver-ion packed-column supercritical fluid chromatography coupled to mass spectroscopy with atmospheric pressure chemical ionization and coordination ion spray.

Characterization of triglycerides in vegetable oils was achieved by silver-ion packed-column supercritical fluid chromatography (SI-pSFC) with mass spectrometric detection. Hyphenation was made using commercially available liquid chromatography-mass spectrometry (LC-MS) interfaces without any modification. A make-up fluid was delivered through a T-piece placed before or after the SFC restrictor by means of a high pressure pump. Atmospheric pressure chemical ionization (APCI) and coordination ion spray (CIS) with silver ions were used as ionization modes. Compared to UV detection, the sensitivity was increased by a factor of 100. Both ionization modes are generating similar structural information. Molecular ions [M-H]+ or [M-Ag(-)] are observed in the mass spectra with exception of the saturated triglycerides for which only CIS gives intense molecular ions. The position at which the fatty acids are esterified to the glycerol backbone can be elucidated by pSFC-APCI although it remains speculative whether this is valid for highly unsaturated triglycerides because reference compounds are not available to proof this.

Atmospheric Pressure↗

Atmospheric pressure photoionization mass spectrometry.

Atmospheric pressure photoionization (APPI) is the last arrival in the family of atmospheric pressure ionization (API) methods to couple mass spectrometry (MS) to liquid-phase separation techniques. The basic idea was to further extend the fields of application of liquid chromatography (LC)-MS to those molecules that are not, or are poorly amenable, to electrospray (ESI) or APCI. The present review explores the literature. After a short introduction with an historical background and the premises for its development, we describe the technique, its physical principles, and the factors that affect its efficiency. The review also presents a survey of applications in different fields.

Atmospheric Pressure↗

Detection of liquid injection using an atmospheric pressure ionization radiofrequency plasma source.

An atmospheric pressure rf plasma source which operates in a variety of different buffer gases has been developed as an ionization method for organic samples introduced by liquid injection into atmospheric pressure ionization mass spectrometry (API/MS). The rf source can operate in He at < 1 W of load power at 165 kHz. It can also be sustained in Ar, N2, air, and CO2 at a load power of < 15 W. In most cases studied, the protonated molecule, MH+, is observed with little or no fragmentation even under the relatively high current conditions of the discharge. However, using increasingly higher acceleration voltages between the skimmers in the differentially pumped region between atmospheric pressure and high vacuum, one can induce fragmentation via collision-induced dissociation. This can be assisted in these experiments via the use of a heavy buffer gas. The detection limits achieved for rf/API plasma detection are typically in the low femtomole region for small organic molecules including neurotransmitters, PTH-amino acids, steroids, drugs, pesticides, and explosives. The detection can be performed with quantitation over at least 4 orders of magnitude.

Air Ionization↗

Pressure-volume relationships above and below atmospheric pressure in the synovial cavity of the rabbit knee.

1. The pressure-volume relationship in the synovial cavity of the rabbit knee was investigated by the infusion of a non-absorbable oil into the cavity. 2. The pressure (P)-volume (V) curve was sigmoid. Its slope dP/dV (elastance) was steep at subatmospheric, physiological pressures, least steep at 5 cm H2O, and steepened progressively at higher, pathological pressures. 3. Elastance dP/dV was a good approximation to linear functions of P below atmospheric pressure and above 5 cm H2O. Each part of the pressure-volume relationship could therefore be described by an exponential expression. 4. Flexion of the joint increased pressure at a given volume. This was mainly due to steepening of the pressure-volume curve, and also partly due to a shift towards the pressure axis. 5. Pressure-volume curves determined by the infusion of normal saline or Krebs solution were grossly distorted, because these fluids were absorbed across the permeable synovium. 6. The physiological significance of the synovial pressure-volume curve is discussed, and mechanical explanations of the curve are suggested.

Animals↗

The potential of organic (electrospray- and atmospheric pressure chemical ionisation) mass spectrometric techniques coupled to liquid-phase separation for speciation analysis.

The use of mass spectrometry based on atmospheric pressure ionisation techniques (atmospheric pressure chemical ionisation, APCI, and electrospray ionisation, ESI) for speciation analysis is reviewed with emphasis on the literature published in and after 1999. This report accounts for the increasing interest that atmospheric pressure ionisation techniques, and in particular ESI, have found in the past years for qualitative and quantitative speciation analysis. In contrast to element-selective detectors, organic mass spectrometric techniques provide information on the intact metal species which can be used for the identification of unknown species (particularly with MS-MS detection) or the confirmation of the actual presence of species in a given sample. Due to the complexity of real samples, it is inevitable in all but the simplest cases to couple atmospheric pressure MS detection to a separation technique. Separation in the liquid phase (capillary electrophoresis or liquid chromatography in reversed phase, ion chromatographic or size-exclusion mode) is particularly suitable since the available techniques cover a very wide range of analyte polarities and molecular mass. Moreover, derivatisation can normally be avoided in liquid-phase separation. Particularly in complex environmental or biological samples, separation in one dimension is not sufficient for obtaining adequate resolution for all relevant species. In this case, multi-dimensional separation, based on orthogonal separation techniques, has proven successful. ESI-MS is also often used in parallel with inductively coupled plasma MS detection. This review is structured in two parts. In the first, the fundamentals of atmospheric pressure ionisation techniques are briefly reviewed. The second part of the review discusses recent applications including redox species, use of ESI-MS for structural elucidation of metal complexes, characterisation and quantification of small organometallic species with relevance to environment, health and food. Particular attention is given to the characterisation of biomolecules and metalloproteins (metallothioneins and phytochelatins) and to the investigation of the interaction of metals and biomolecules. Particularly in the latter field, ESI-MS is the ideal technique due to the softness of the ionisation process which allows to assume that the detected gas-phase ions are a true representation of the ions or ion-biomolecule complexes prevalent in solution. It is particularly this field, important to biochemistry, physiology and medical chemistry, where we can expect significant developments also in the future.

Atmospheric Pressure↗

Direct analysis of semivolatile organic compounds in air by atmospheric pressure chemical ionization mass spectrometry.

Atmospheric pressure chemical ionization is employed for direct air analysis, without ion source modification, by using the sheath gas as the sample transport agent. A simple modification of the sheath gas inlet line allows introduction of gaseous samples into a commercial atmospheric pressure chemical ionization source. Optimization and testing of this novel air sampling method are described and detection of semivolatile compounds is shown. The analytical performance of the technique is established with methyl salicylate, including a limit of quantification of 100 pptr, a limit of detection of 50 pptr, a linear response from 100 pptr to 20 ppb, and rise and fall times of 12 and 20 s, respectively. Using reagent ion monitoring, it is shown that the protonated methanol dimer is the principal CI reagent ion leading to protonated dimethyl methylphosphonate, while the monomer is mainly responsible for protonating methyl salicylate. Since the formation of the CI reagent (methanol clusters) can be controlled by simple variation of experimental parameters, the selectivity of the method can be easily adjusted to suit the targeted analyte. Performance is found to be independent of the choice of air or nitrogen as the sheath gas (and thus as the sample matrix) and this, together with the sensitivity and speed of the technique, make it promising for field studies.

Journal Article↗