Search PubMedSearch

SEARCH · Search PubMed

Results for “3D measurement”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

291 recordsLinked to original sources

Which radiographic plane should be used to quantify the distal tibia angle on weightbearing CT images?

BACKGROUND: Precise quantification of distal tibial alignment is essential for planning corrective osteotomies and ankle joint replacement surgery. The lateral distal tibial angle (LDTA) is the principal radiographic parameter used for this purpose. While LDTA is increasingly measured on weightbearing cone-beam CT (WBCT) using two-dimensional coronal slices, the optimal measurement plane remains unclear. METHODS: In this retrospective comparative study, full-leg WBCT scans of patients scheduled for supramalleolar osteotomy (n&#x202f;=&#x202f;20; mean age 47&#x202f;&#xb1;&#x202f;12.8 years) were analyzed. LDTA was measured on three coronal planes of the distal tibial plafond (anterior edge, mid-dome, posterior edge) and compared with semi-automated three-dimensional (3D) tibial alignment measurements as the reference standard. RESULTS: Mid-dome LDTA showed no significant difference from the 3D reference (p&#x202f;>&#x202f;0.05) and demonstrated excellent agreement. Anterior measurements significantly overestimated LDTA, while posterior measurements underestimated it (both p&#x202f;<&#x202f;0.05), with only fair agreement. CONCLUSION: LDTA should be measured at the mid-dome of the distal tibial plafond on WBCT to ensure accurate and reproducible alignment assessment. LEVEL OF EVIDENCE: Level III - Retrospective Comparative Study.

Humans

Fused Deposition Modeling (FDM) of polyether-ether-ketone (PEEK) dental implants: A systematic review of the effect of printing parameters on mechanical behaviour and surface quality.

PURPOSE: This systematic review evaluated how FDM printing parameters influence mechanical behaviour and surface characteristics of 3D-printed PEEK and identified parameter combinations linked to the most favourable mechanical performance and surface quality. MATERIALS AND METHODS: An electronic search was conducted in: MEDLINE (Ovid), PubMed, Embase, Web of Science, Scopus, and Compendex (last update: January 2025). Studies that evaluated the effect of FDM printing parameters on mechanical and surface properties of PEEK were included. Outcomes comprised compressive, tensile, and flexural strengths, elastic modulus, fracture toughness, surface hardness, roughness, and wettability. RESULTS: Of 4005 reports screened, 54 manuscripts were included. 92.6% (n&#x202f;=&#x202f;50) of articles showed low risk-of-bias, while 7.4% (n&#x202f;=&#x202f;4) showed medium risk-of-bias. Tensile strength was the most investigated mechanical parameter (78%), followed by elastic modulus (41%), flexural strength (30%), compressive strength (20%), and fracture toughness (6%). Surface roughness was the most evaluated surface property (30%), followed by hardness (17%) and wettability (6%). Across studies, higher printing temperatures, lower printing speed, thinner layer thickness, and maximum infill ratio in a horizontal printing orientation were associated with higher strengths, less warpage, increased accuracy, and improved surface quality. CONCLUSION: Specific combinations of FDM printing parameters can significantly improve the mechanical and surface properties of PEEK. However, it is difficult to meet all the optimal conditions simultaneously. Thus, balancing between different parameters must be considered in practical production.

Benzophenones

Coupling of spectroscopy and nitrogen-oxygen isotopes unveils the mechanisms of dissolved organic matter and nitrate pollution in lakes within the agro-pastoral transition zone.

Lakes in arid and semi-arid regions are subjected to severe ecological stress, such as organic pollution, eutrophication, and salinization, due to climate change and human activities. This study investigates Chagannur Lake, a typical arid-region lake that is representative and ecologically sensitive in Northern China's agro-pastoral ecotone, to uncover its pollution characteristics and mechanisms. We employed fluorescence spectroscopy and stable isotope analysis to trace dissolved organic matter (DOM) and nitrate sources. The DOM composition was dominated by microbial metabolic byproducts and protein-like substances, suggesting that microbial processes are key to organic matter transformation. Source apportionment revealed that pollutants primarily originated from livestock and poultry manure (37.6 %), agricultural fertilizers (35.6 %), and soil erosion (24.7 %), with agricultural fertilizers contributing most significantly in the Gogstai River (63.3 %). A structural equation model (SEM) coupling spectral and mass spectrometric data revealed that microbial transformation significantly impairs the lake's self-purification capacity, thereby promoting pollutant accumulation (path coefficient = 0.91,*p < 0.05). Moreover, microbial processes link endogenous and exogenous pollution, a mechanism effectively traced by isotopic and fluorescence indices (path coefficient = 0.55, &#x204e;&#x204e;p < 0.01). These findings enhance the understanding of pollution sources and transformation mechanisms in arid-region lakes and offer foundational theoretical support for policymakers engaged in pollution control strategies.

Lakes

Spatially confined electrochemical strategy with DNA-assembled nanogaps for SNP detection.

Accurate detection of low-abundance single nucleotide polymorphisms (SNPs) against a large excess of homologous wild-type sequences requires both selective molecular recognition and effective transduction of small sequence differences into measurable signals. Here, we report a spatially confined electrochemical strategy that couples sequence-selective recognition with size-dependent mass-transport gating. DNA-hybridization-driven self-assembly of gold nanoparticles (AuNPs) forms a three-dimensional self-assembled electrode (3D-SAE) with a DNA-defined interparticle architecture. Competitive probes (SP/WP) convert single-base recognition into distinct molecular-size states: the SNP-associated pathway preferentially triggers a hybridization chain reaction (HCR), generating bulky AuNP-anchored HCR/methylene blue complexes (Au@HCR/MB) with reduced electrochemical accessibility through the porous 3D-SAE, whereas the wild-type pathway does not trigger HCR and maintains a high-current response from more readily accessible MB-containing species. Thus, sequence recognition is translated into a molecular-size difference and subsequently into an electrochemical signal through differential mass transport. Under buffer conditions, the platform achieved a statistically estimated detection limit of &#x223c;0.47&#x202f;fM and a quantitative range of 1&#x202f;fM-100 pM. It discriminated a 0.1% mutant abundance in a fragmented genomic-DNA background. The downstream signal-transduction chemistry is enzyme-free and isothermal. This work establishes a mechanistical recognition-size-conversion-mass-transport-gating architecture for electrochemical nucleic acid analysis.

Polymorphism, Single Nucleotide

Retrosigmoid craniotomy surgical guide: The way forward for precise exposure of the transverse-sigmoid sinuses.

INTRODUCTION: The retrosigmoid craniotomy is the workhorse approach to the cerebellopontine angle. Accurate localisation of the transverse-sigmoid junction (TSJ) is key for optimised exposure and cerebellar retraction. Various methods, both anatomical and navigational, have been used but with suboptimal results. We utilised a 3D-printed retrosigmoid surgical guide in an attempt to overcome this and report our early outcomes and experiences in the design, production and utilisation of the guide. METHODS: This is a prospective cohort study of the patients with retrosigmoid craniotomies performed using the surgical guides. Patient demographics and diagnoses, along with the accuracy of the planned burrhole and craniotomy, need for craniotomy extension, presence of venous sinus injury, set-up time, and cost were reported. RESULTS: There were ten cerebellopontine angle cases in which the surgical guides were utilised, three petrous meningiomas, two trigeminal neuralgias, two metastasis, and three other tumours. The planned burrhole and craniotomy were precise in all cases with accurate exposure of the TSJ and no requirement for craniotomy extension. The mean set up time was 3.9&#xa0;min, and the mean cost of the surgical guides was USD 470.90. One elderly patient had an intraoperative transverse sinus injury related to adherent dura that was planned for exposure. CONCLUSION: The 3D-printed surgical guide is a potential solution to the rapid, precise and consistent identification of the TSJ when performing a retrosigmoid craniotomy. We present our early experience and discuss nuances in the designing, production, and intraoperative phases to optimise the precision of this guide. We suggest two methods to avoid sinus injury in elderly patients: either to plan the craniotomy to the edge of the sinus, or to plan sinus exposure but to use burr drills rather than the osteotome, as in our case, to expose the sinus.

Humans

Alginate-based edible coating incorporating green tea extract for preserving postharvest quality and safety of white mushrooms (Agaricus bisporus).

This study aimed to evaluate the effects of a sodium alginate based edible coating incorporated with green tea extract (GTE) (Camellia sinensis) on the postharvest quality attributes and antimicrobial activity against Listeria monocytogenes in white mushrooms during refrigerated storage. The phenolic profile of GTE was characterized, and its minimum inhibitory concentration (MIC) against L. monocytogenes (1.6&#xa0;mg/mL) was determined. Sodium alginate coatings, with (ALG-GTE) or without GTE (ALG) at MIC (1.6&#xa0;mg/mL), were characterized (functional groups, solubility in water, moisture, thickness, water contact angle and color) for their chemical and physical properties. The effects of ALG-GTE coatings on quality parameters (firmness, weight loss, color, pH, sugars and organic acids), enzymatic activity [polyphenol oxidase (PPO), peroxidase (POD) and pectin methylesterase (PME)], antimicrobial activity against L. monocytogenes (5 log CFU/g), and surface characteristics (3D optical profilometry) were assessed in white mushrooms (Agaricus bisporus) during refrigerated storage (8&#xa0;days, 4&#xa0;&#xb1;&#xa0;1&#xa0;&#xb0;C, 90-95% RH). The ALG-GTE coatings preserved sugar composition, particularly rhamnose, reduced organic acids accumulation and delayed weight and firmness loss, reduced color changes, and decreased PME activity in coated white mushrooms. L. monocytogenes counts decreased by 1.4 log CFU/g after 1&#xa0;day, and no viable cells were detected after 2&#xa0;days (< 1.5 log CFU/g) in ALG-GTE coated white mushrooms. In addition, ALG-GTE coated white mushrooms exhibited smoother surfaces than uncoated samples. These findings highlight the potential of ALG-GTE coatings as a sustainable alternative capable of improving the microbiological safety and delaying the postharvest changes in fresh mushrooms.

Agaricus

Clinical accuracy and short-term outcomes of intraoral photogrammetry for complete-arch implant rehabilitation: A retrospective multicentre study on 35 patients.

OBJECTIVES: To evaluate the clinical accuracy and short-term outcomes of complete-arch implant-supported fixed dental prostheses (ISFDPs) fabricated using an intraoral photogrammetry (IPG) based digital workflow in completely edentulous patients. METHODS: This multicenter retrospective clinical study included 35 patients rehabilitated with 52 complete-arch ISFDPs (10 FP1, 18 FP2 and 24 FP3 restorations) supported by 221 implants. All definitive prostheses were designed and fabricated using a fully digital workflow initiated by IPG acquisition with the Aoralscan Elite IPG&#xae; (SHINING 3D). The primary outcome was clinical accuracy, assessed at definitive prosthesis delivery through evaluation of passive fit using the Sheffield test and radiographic verification. Secondary outcomes included biologic and prosthetic complications, as well as implant and prosthesis survival rates during the follow-up. RESULTS: Passive fit was achieved in all definitive restorations (100%). Radiographic evaluation confirmed accurate marginal adaptation at the implant-prosthesis interface in all cases. No statistically significant differences in clinical accuracy were observed according to treated arch, number of supporting implants, or prosthetic design (P > .05). During a mean follow-up period of 12.1 &#xb1; 3.5 months, biologic and prosthetic complications were limited and generally minor. Implant survival was 99.5%, and prosthesis survival was 100%. CONCLUSIONS: Within the limitations of this retrospective clinical study, the IPG based workflow demonstrated high clinical accuracy and predictable short-term outcomes for complete-arch implant rehabilitation, consistently enabling passive fit and favorable prosthetic performance. CLINICAL RELEVANCE: IPG may represent a clinically reliable and predictable approach for complete-arch digital implant impression acquisition. The high rates of passive fit, together with the low incidence of biologic and prosthetic complications observed in this multicenter clinical study, support the use of IPG based workflows for the fabrication of complete-arch ISFDPs.

Humans

Patient-reported outcomes in pediatric regional anesthesia trials: current use and limitations.

PURPOSE OF REVIEW: This review examines the current use and limitations of patient-reported outcome measures (PROMs) in pediatric regional anesthesia research. Despite the increasing emphasis on patient-centered outcomes, existing pediatric outcome assessment frameworks may inadequately capture the pain experience and interference with daily living. RECENT FINDINGS: Across 17 identified randomized controlled trials and 15 ongoing studies, PROM use remains highly variable, with consistent reliance on observational pain scales such as the Face, Legs, Activity, Cry, and Consolability scale and limited incorporation of standardized, longitudinal health-related quality-of-life measures. SUMMARY: Current pediatric PROM frameworks remain fragmented, limiting comprehensive evaluation of recovery. Greater standardization and incorporation of developmentally appropriate, longitudinal outcome measures are needed to better align clinical research with meaningful patient-centered endpoints and to improve assessment of functional and psychosocial recovery.

Humans

Patient-reported outcome measures for depression or anxiety symptoms in patients with cardiovascular disease: A COSMIN systematic review.

BACKGROUND: Depression and anxiety are common in patients with cardiovascular disease (CVD), but the measurement quality of patient-reported outcome measures (PROMs) used in this population remains unclear. This review aimed to evaluate the methodological quality, measurement properties, and certainty of evidence for depression and anxiety PROMs in adults with CVD and to inform instrument selection. METHODS: Following COSMIN and PRISMA guidance, four databases were searched from inception to February 2026. Studies assessing measurement properties of PROMs in adults with CVD were included. Methodological quality was evaluated using the COSMIN Risk of Bias checklist, and certainty of evidence was graded using an adapted GRADE approach. RESULTS: Sixty-six studies assessing 38 PROMs were included, comprising 29 generic and 9 CVD-specific instruments. Six PROMs met COSMIN Category A criteria: Cardiac Depression Scale-Short Form, Patient Health Questionnaire-9, Beck Depression Inventory-II, Hospital Anxiety and Depression Scale, Generalized Anxiety Disorder-7, and Major Depression Inventory. Four instruments were classified as Category C because of insufficient structural validity. Content-validity evidence was largely indeterminate or of limited certainty. Only 24 studies used confirmatory factor analysis or Rasch analysis, and no study assessed measurement error or responsiveness. Cross-cultural validity evidence was scarce. CONCLUSIONS: Six PROMs met Category A criteria, but selection should remain purpose- and context-specific. Particular attention should be given to somatic symptom overlap and intended clinical use. Further validation should prioritize content validity, measurement invariance, responsiveness, measurement error, and clinimetric performance.

Humans

Timing of OMERACT core domain measurement in gout clinical trials: a systematic review of randomised trials.

AIMS: The Outcome Measures in Rheumatology (OMERACT) initiative has endorsed core domain sets for gout trials. The aims of this study were to evaluate the time points and frequencies at which the gout core domains are measured in existing gout urate-lowering therapy and gout flare trials, and whether all collected measurements were reported. METHODS: Urate-lowering therapy (n = 29) and gout flare randomised clinical trials (n = 14) from 2005 were identified from a prior systematic review of core domain reporting. Data were extracted for the time points and frequencies at which each core domain was measured, as well as whether all collected measurements were reported. RESULTS: In urate-lowering therapy trials, the core domains were measured at seven different frequencies. Serum urate and gout flares were most commonly measured monthly, and tophus burden was most commonly measured three monthly. Reporting of all collected measurements varied, from 24/29 (83%) trials for serum urate to 0/2 (0%) trials for activity limitation. In gout flare trials, core domains were measured at nine different frequencies. Pain, joint tenderness and joint swelling were most commonly measured monthly. Reporting of all collected measurements varied, from 13/14 (93%) trials for pain to 3/8 (37.5%) trials for joint tenderness. CONCLUSION: In both urate-lowering therapy and gout flare trials, there is substantial variability in when the core domains are measured, and reporting of collected measurements is inconsistent. This work provides the foundation for a consensus process to establish standardised time points and frequencies for measuring the OMERACT-endorsed gout core domains.

Gout

Sensor-based measures of knee brace adherence have low agreement with self-report methods: A multi-measure study among knee osteoarthritis patients.

OBJECTIVE: To explore agreement between self-report and objectively measured adherence to brace wearing by patients with knee osteoarthritis. METHOD: A single-arm observational analysis nested within the PROP OA randomised controlled trial (ISRCTN28555470). Of 237 adults with symptomatic knee osteoarthritis randomised to brace treatment, 60 were included in this sub-study investigating three different methods of assessing knee brace wear time over 26 weeks: 1. Self-report questionnaires (SRQ) at 12 weeks and 26 weeks; 2. Short message service (SMS) questions (days worn in past week, typical hours per day when worn) administered from week 1 to week 24; 3. A skin temperature sensor embedded in the brace, sampling every 10&#x202f;min for 26 weeks. The presence and reason for the sensor were concealed from participants. The estimated proportion of participants meeting "minimum brace use", defined a priori as &#x2265;1&#x202f;h on &#x2265;2 days in past week, was described for each measurement method, overall and by brace type (unloader, neutral). For temperature sensor measurements, time spent above 24&#xb0;C and time spent above 25&#xb0;C were used. Agreement between the measures was summarised by percentage agreement and kappa (&#x138;). RESULTS: The estimated proportions of participants meeting "minimum brace use" at 12 weeks were 83% (SRQ), 83% (SMS), 60% and 58% (temperature sensor, 24&#xb0;C and 25&#xb0;C thresholds, respectively). At 26 weeks, the corresponding estimates reduced to 72%, 71% (SMS at 24 weeks), 43% and 37%. Sensor data suggested the sharpest decline in brace use occurred within the first 12 weeks. Agreement between self-report measures was higher than between self-report measures and sensor (SRQ vs SMS at 12 weeks: 92% agreement, &#x138;=0.67 (95%CI: 0.34, 1.00); SRQ vs Sensor at 12 weeks: 74%, 0.35 (0.10, 0.60); SMS vs Sens at 12 weeks: 76%, 0.36 (0.05, 0.66). Agreement between all measurement methods reduced at 26 weeks. CONCLUSIONS: This novel use of a temperature sensor to monitor brace adherence in knee osteoarthritis indicates that self-report adherence substantially overestimates knee brace wearing time, with implications for clinical trials and practice.

Humans

The impact of absolute change in tibiofemoral morphology on patient reported outcome measures post total knee arthroplasty.

BACKGROUND: Reconstructing knee morphology and alignment is important for outcomes post total knee arthroplasty (TKA). Personalised alignment strategies are proposed to improve outcomes by replicating native alignment. However, how change in morphology affects patient outcomes is unclear. This study aimed to investigate the relationship between absolute change in morphological measures post-TKA and patient reported outcome measures (PROMs). METHOD: An observational analysis of a randomised clinical trial was conducted. Participants received preoperative and postoperative CT scans and completed PROMs at six-months post-TKA. Absolute change in hip-knee-ankle angle, medial proximal tibial angle, lateral distal femoral angle, non-weightbearing joint line convergence angle, tibial and femoral rotation, and posterior tibial slope (PTS) were calculated. PROMs included visual analogue scales of pain and satisfaction (0-100), Oxford Knee Score, Forgotten Joint Score, and the Kujala Score. Regression and principal component (PCA) analyses investigated relationships between PROMs and change in morphology. RESULTS: Sixty-one participants were included for analysis (61% women, age 66.9&#xa0;&#xb1;&#xa0;9.1 [mean&#xa0;&#xb1;&#xa0;SD] years, BMI 32.8&#xa0;&#xb1;&#xa0;6.8&#xa0;kg/m2). The PCA demonstrated coronal, axial, and sagittal plane measures were interdependent, with over 65% of variability driven by change in tibial rotation (PC1) and the PTS (PC2). The regression analysis showed no relationships between morphological change and PROMs postoperatively. CONCLUSION: Tibiofemoral morphology was interrelated across coronal, axial, and sagittal planes. However, this study suggests absolute morphological change had minimal impact upon PROMs at six-months post-TKA. Future research should clearly distinguish between osteoarthritic versus prearthritic alignment and consider the influence of soft-tissue releases upon PROMs.

Humans

Measuring Coping Strategies in Daily Life: A Systematic Review of Experience Sampling Methodology and Daily Diary Studies.

Advances in daily diary methods and experience sampling method (ESM) have improved the study of coping strategies in daily life and their role in shaping health and well-being. In this review, we examine study designs, measurement approaches, and analytical practices used to investigate coping in natural contexts. We performed a systematic review of studies published before 5 December 2025 that used daily diary or ESM to measure coping strategies over multiple days or moments. Studies were examined with regard to sampling schemes, assessment frequency and duration, measurement of coping strategies, incorporation of stressor appraisals, and analytic techniques used to model coping processes. Fifty-five studies met the inclusion criteria. Results indicated that 80% employed end-of-day diary designs, generally lasting 1-3 weeks, whereas higher-frequency ESM protocols were less common and ranged 2-14&#xa0;days. Coping strategies were often assessed using abbreviated or single-item measures, frequently adapted from established questionnaires. Many studies incorporated appraisals such as perceived stressor intensity or controllability, enabling tests of coping flexibility. Multilevel modelling was the dominant analytic approach, allowing researchers to distinguish within-person dynamics from between-person differences. However, analyses were predominantly concurrent, and temporally ordered models remained comparatively rare. Overall, the literature demonstrates substantial progress in capturing coping in everyday contexts, yet heterogeneity in measurement and limited use of temporal modelling constrain cumulative knowledge about the temporal links between coping and psychological and physiological health outcomes. Future research would benefit from greater alignment between theoretical assumptions, assessment strategies, and analytic methods.

Humans

Long-term outcomes of surgical correction of ventral penile curvature in children: Patient-reported measures, surgical results, and decisional regret.

INTRODUCTION: There is a dearth of data on long-term outcomes, including patient-reported outcomes (PROMs), decisional regret, and complication rates for surgical correction of isolated ventral penile curvature in childhood. PATIENTS AND METHODS: Twenty-six children treated for ventral curvature between 1993 and 2008 were identified; 24 met inclusion criteria (isolated ventral curvature without hypospadias or need for urethral reconstruction). Surgical correction consisted of degloving alone or degloving with Nesbit-like dorsal plication when residual curvature >20&#xb0; persisted after degloving. PROMs were collected via pre-mailed validated questionnaires after puberty: Danish Prostatic Symptom Score (DAN-PSS) for LUTS, Erection Hardness Score (EHS) for erectile function, Penile Perception Score (PPS) for cosmetic perception, and items assessing decisional regret and perceived appropriateness of surgical timing. RESULTS: Curvature was corrected intraoperatively in all 24 patients. Twelve underwent degloving alone and 12 required additional dorsal plication. During long-term follow-up (median 14.2 years), one patient (4%) underwent re-operation for residual curvature, and three (13%) underwent cosmetic revisions; two (8%) underwent cystoscopy for flow concerns. 71% returned PROMs at a median age of 16.2 years. LUTS were uncommon, with low bother scores. Erectile function was favorable: 87% (13/15) reported EHS 4 and 93% (14/15) reported ejaculation. Cosmetic outcomes were favorable, with PPS dissatisfaction rates comparable to controls. Two patients reported dissatisfaction with overall appearance, and one with residual subjective curvature. No patient expressed decisional regret, and 88% felt timing of surgery was appropriate. CONCLUSION: Early surgical correction of isolated ventral penile curvature using degloving with or without dorsal plication provided durable anatomical correction and favorable long-term functional and cosmetic outcomes. These findings support early intervention as an effective approach with sustained patient-perceived benefits.

Humans

Measurement of low-density lipoprotein cholesterol and other circulating lipids in Brazil: a systematic literature review.

Accurate laboratory assessment of circulating lipids underpins cardiovascular risk stratification, yet clinical interpretation depends not only on the assays but on the formula chosen to estimate low-density lipoprotein cholesterol (LDL-C). This review integrates the 2019-2025 evidence on laboratory methods for triglycerides (TG), total cholesterol (TC), and high-density lipoprotein cholesterol (HDLC), and on the formulas estimating LDL-C, VLDL-C, and non-HDL cholesterol, to determine how these should be measured, reported, and harmonized in Brazil, where lipid thresholds are adapted from international consensus. A PRISMA 2020 systematic search (PROSPERO CRD420251241064) of PubMed/MEDLINE, Scopus, SciELO, LILACS, Web of Science, and Embase retrieved 57,915 records; after removing 38,210 duplicates, 19,705 titles/abstracts were screened, 312 full texts assessed, and 25 sources included. Enzymatic colorimetric assays remain standard for TG, TC, and HDLC. For LDL-C, Martin/Hopkins classifies more accurately than Friedewald (89.6% vs 83.2% correct categorization in 5,051,467 patients), particularly at high TG and low LDL-C, while Sampson/NIH and modified Sampson/NIH extend reliable estimation into hypertriglyceridemia and very low LDL-C; direct measurement is reserved for TG beyond the validated range. Although the review centers on the Friedewald, Martin/Hopkins, and Sampson/NIH families that dominate guideline practice, other published equations exist and are addressed in context. In Brazil, atherogenic-lipid thresholds are risk-based decision limits rather than reference intervals; national surveys describe lipid distributions but were not designed to establish them. Analytical standardization through traceability programs, multicenter validation of formulas, and-where the distribution-based construct applies (HDLC, pediatrics)-nationally derived reference intervals are priorities for equitable cardiovascular risk assessment in Brazil.

Humans

Measuring economic efficiency in adult intensive care units: A systematic review of methods, metrics, and evidence.

OBJECTIVES: Intensive care units (ICUs) consume substantial hospital resources, yet "efficiency" is inconsistently defined and measured. This study systematically reviewed how economic efficiency has been conceptualised and quantified in adult ICUs and appraised the quality of evidence. METHODS: Following PRISMA 2020 and a PROSPERO-registered protocol (CRD420251107866), we searched MEDLINE, Embase, CINAHL, Cochrane Library and Web of Science (2000-August 2025), plus global grey sources. Eligible studies explicitly defined efficiency and reported an efficiency metric/model linking ICU inputs (e.g., staff, beds/capacity, time, consumables, or costs) to outputs/outcomes (e.g., throughput/discharges, length of stay/resource use, risk-adjusted mortality). Dual independent screening and extraction were performed. Study quality was appraised using MMAT, and findings were synthesised narratively (SWiM), given heterogeneity. RESULTS: 39 studies (2001-2025) from 17 countries were included, all from high-income or upper-middle-income settings. Four methodological families were identified: (1) frontier modelling (predominantly DEA; occasional SFA/RFDH), (2) benchmarking indicators (risk-adjusted mortality and LOS/resource-use ratios; "efficiency matrix" quadrant classification), (3) cost-outcome evaluations, and (4) operational/process metrics. Across families, variation in decision-making units, input/output selection, and risk adjustment limited comparability; long-term and patient-reported outcomes were absent, and equity considerations were uncommon. CONCLUSIONS: ICU efficiency research is feasible but fragmented and often methodologically limited. Standardised definitions, validated risk adjustment, uncertainty quantification, and inclusion of patient-centred and equity-relevant outcomes are needed before efficiency metrics can reliably inform value-based decision making.

Intensive Care Units

Clinical performance of monolithic and veneered zirconia three-unit posterior FDPs: A five-year multicenter randomized controlled trial.

AIM: This randomized controlled clinical study compared monolithic, partially veneered, and fully veneered zirconia FDPs over a 5-year period with respect to survival, technical and biological complications, and patient-reported outcome measures (PROMs). MATERIALS AND METHODS: Sixty-four patients requiring three-unit posterior FDPs were randomly allocated to monolithic (MONO-FDP), partially veneered (PV-FDP), or fully veneered (FV-FDP) groups. All FDPs were fabricated from 4 mol% Y&#x2082;O&#x2083; partially stabilized zirconia (4Y-TZP). Follow-up examinations were conducted at baseline, 1, 3, and 5 years. Technical parameters were evaluated using modified USPHS criteria. Periodontal measurements (PPD, BOP, PI) and patient satisfaction were assessed at all time points. RESULTS: A total of 63 FDPs were evaluated at baseline, 57 at 3 years, and 54 at 5 years. Survival at 5 years was 94.7% for MONO-FDPs, 100% for FV-FDPs and 100% for PV-FDPs. Technical complications occurred exclusively in PV-FDP (33%) and FV-FDP (38%) groups and consisted of minor, polishable chipping; no chipping or fractures were recorded in MONO-FDPs (0%) with statistically significant difference between MONO-FDP and the other two groups (p &#x2264; 0.014). Biological parameters remained stable across all groups, with no significant differences in PPD, BOP, or PI. PV-FDPs and FV-FDPs tended to receive more favorable professional color ratings, whereas PROMs were similar among the groups. CONCLUSIONS: All three FDP designs-monolithic, partially veneered, and fully veneered-fabricated from 4Y-TZP zirconia demonstrated excellent 5-year clinical performance. Technical complications were limited to PV- and FV-FDPs and consisted of minor chipping. Biological outcomes and patient satisfaction were similar across groups. CLINICAL SIGNIFICANCE: The five-year outcomes suggest that veneered, partially veneered, and monolithic FDPs can be used with high clinical reliability; however, restorations incorporating veneering ceramic may present an elevated risk of ceramic chipping.

Humans

Association between cumulative social disadvantage, as measured by the social determinants of health score, and epilepsy: a cross-sectional study.

BACKGROUND: Social determinants of health (SDoH) shape access to care, health behaviors, and long-term outcomes, yet their cumulative relationship with epilepsy has not been well quantified. This study examined whether a composite SDoH score was associated with epilepsy in adults. METHODS: This cross-sectional study used data from the National Health and Nutrition Examination Survey 2013-2018. The SDoH score ranged from 0 to 8 and summarized eight unfavorable social conditions. Epilepsy was identified using medication-based ascertainment. Survey-weighted logistic regression models were applied to evaluate the association between SDoH score and epilepsy. Restricted cubic spline, subgroup, sensitivity, and receiver operating characteristic analyses were also performed. RESULTS: A total of 13,119 participants were included, of whom 114 had epilepsy. Participants with epilepsy had a higher mean SDoH score than those without epilepsy (3.41&#xa0;&#xb1;&#xa0;0.24 vs. 2.35&#xa0;&#xb1;&#xa0;0.06, P&#xa0;<&#xa0;0.001). In the fully adjusted model, each 1-point increase in SDoH score was associated with 31% higher odds of epilepsy (OR 1.31, 95% CI 1.16-1.48). Compared with the low-score group (0-2), the adjusted odds ratios were 2.09 (95% CI 1.06-4.15) for scores of 3-5 and 2.67 (95% CI 1.34-5.33) for scores of 6-8. Spline analysis showed a significant overall association without evidence of nonlinearity. Adding SDoH components to demographic variables improved model discrimination (AUC 0.731 vs. 0.589, P for difference <0.001). CONCLUSION: Greater cumulative social disadvantage, as reflected by the SDoH score, was associated with higher odds of epilepsy.

Humans