Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “electromagnetic fields”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99Linked to original sources

Effect of localized pulsed electromagnetic fields on tail-suspension osteopenia in growing mice.

Pulsed magnetic fields (PEMFs) have been used effectively to treat bone fractures and sciatic-nerve-section-induced osteopenias. Properly applied PEMFs are presumed to stimulate osteogenesis. Mouse-tail suspension has been implemented as a means of inducing an osteopenic response in the long bones of the hind limbs. To evaluate localized PEMF effects, the mouse-suspension model was modified to accommodate the use of miniature wire coils affixed directly to the rear legs. Laterally and axially orientated PEMF effects were compared. Three test groups of mice included (C) control mice, (S) tail-suspended mice with treatment apparatus attached, and (SF) tail-suspended mice with apparatus attached and PEMFs delivered. The SF group was divided into mice receiving axial or lateral PEMFs. Significant bone changes occurred in suspended as compared with control mice after a 2-week test period. The PEMF mice showed significantly fewer osteopenic effects than did untreated, suspended mice. These findings are based on biomechanical measures of stiffness, strength, ductility, and energy as well as whole-bone mass and porosity. The effects of PEMFs on these properties differ for axial and lateral exposures. The results are discussed in terms of mechanisms underlying PEMF effects.

Animals↗

The role of household electromagnetic fields in the development of mammary tumors in women: clinical case-record observations.

BACKGROUND: The relationship between the exposure rates to household EMFs and incidences of mammary tumors has been studied in women based on the materials of the Edith Wolfson Medical Center, Israel. MATERIAL/METHODS: 200,527 biopsy and surgery samples from a period of 26 years were analyzed. The material was divided into two groups: Group 1 included patients with breast tumors from 1978 to 1990 and Group 2 between 1991 and 2003. RESULTS: Breast tumors were found in 2824 women (1.4%). The highest number of tumors was seen in women aged 60 to 69 years. There were 1613 (57.1%) cases in Group 1 and 1211 (42.9%) cases in Group 2. The most frequent malignant cases were invasive ductal carcinomas (1473 of total 2824 cases). These were found in 777 women (52.7%) of Group 1 and 696 women (47.2%) of Group 2. The case records of these patients show that 181 (23.2%) women in Group 1 and 327 (46.9%) in Group 2 were regularly exposed to EMFs (mostly of personal computers) for at least 3 h a day. Despite the significant differences in the number of patients exposed to EMFs for 3 h/day in both groups (chi2=29.7 and p < 0.001), no correlation was found between durable exposure to EMFs and the number of women with malignant tumors in each group. CONCLUSIONS: Results of our studies point to a low potential carcinogenic hazard of low-frequency EMFs.

Adult↗

Electromagnetic field system for transsphenoidal surgery on recurrent pituitary lesions - technical note.

BACKGROUND: Post operative scar tissue makes transsphenoidal surgery for recurrent pituitary lesions very difficult. However, with the use of a new cautery system, known as the EMF system, we were able to perform the surgical procedures with relative ease. In this article, we report the advantages and clinical applications of this new instrument in transnasal reoperation. METHODS: The EMF system generates a high frequency current of 13.56 MHz that is focused on the target. This enables it to coagulate, cut, and vaporize tissue in a pinpoint fashion. The bayonet and pencil-type hand pieces of the EMF system are slim, and the tips of the probe are flexible. This enables the surgeon to easily reach deep narrow spaces. We have used the EMF system for transsphenoidal surgery on recurrent pituitary lesions in 18 patients. The system was used to cut and vaporize scar tissue and vaporize firm and fibrotic tumor tissue. RESULTS: During surgery, the system could easily cut and vaporize scarred tissues in the nasal cavity, the sphenoid sinus, and the sella, without damage to the surrounding tissue. In addition, in 3 patients who had extremely fibrotic and firm tumors, we were able to easily vaporize the tumor with safety. CONCLUSIONS: The EMF system enables the surgeon to cut and vaporize tissue with ease and with minimal injury to the surrounding structures. It was particularly valuable in the resection of firm tumors. It may also shorten the operating time because of quick vaporization of the firm tissue.

Adenoma↗

Alterations of biological parameters in mice chronically exposed to low-frequency (50 Hz) electromagnetic fields.

In an experimental study we measured changes in hematological, biochemical and cortisol parameters in 6-week-old Swiss mice continuously exposed to ELF generated by a transformer station and high current bus bars. Mean daily exposure of 5.0 microT was maintained for 350 days. Hematological parameters were compared to those of control mice (n=12) exposed to a field level lower than 0.1 microT. Serum biochemical parameters (sodium, potassium, chloride, calcium, magnesium, phosphorus, amylase, creatine phosphokinase, and lactate dehydrogenase) were measured after 28 days of exposure and serum cortisol after 90 and 190 days. Granulocyte/macrophage colony-forming cells (GM-CFC) were counted at the end of the 350-day exposure. On day 20, exposed animals showed a significant decrease in leukocyte, erythrocyte, lymphocyte and monocyte counts and in hemoglobin and hematocrit values, while MCV increased. On days 43 and 63 no significant difference was observed in leukocyte and erythrocyte values, as if hemopoiesis had recovered. On day 90, a significant fall in the leukocyte, polynuclear neutrophil and eosinophil counts was observed in the exposed animals. No significant difference was noted in the biochemical parameters studied. On day 190, exposed animals had neutropenia and a decrease in the cortisol value. On day 350, no significant difference in hematological parameters was noted. Individual differences in sensitivity were observed, as 8 mice in the exposed group showed a significant decrease in the leukocyte, polymorphonuclear neutrophil and GM-CFC counts, while in two mice there was a significant increase in these same values compared to those unexposed mice.

Amylases↗

The effect of the pulsatile electromagnetic field in patients suffering from chronic obstructive pulmonary disease and bronchial asthma.

Pulsatile electromagnetotherapy (PETh) stimulates biological tissues and processes; it modulates ion exchange across cell membranes and thus regulates the tone of smooth muscles. On the basis of these effects we hypothetized that PETh might treat COPD and bronchial asthma. We examined 117 (61 females, 56 males) adult patients who were decided in 4 groups. The 1st consisted of 16 patients with COPD who were treated by PETh and pharmacologically. The 2nd group (control) consisted of 24 patients with COPD who were treated only with medicaments. The 3rd group consisted of 37 asthmatics, treated by PETh and medicaments. The 4th group (control) consisted of 40 asthmatics treated only with medicaments. The effectiveness of PETh was assessed by lung function tests, which were performed using a Spirometer 100 Handi (Germany). We measured FVCex, FEV1, percentage of FEV1/FVCex, MEF25, 50, 75, PEF and registered the flow-volume loops. PETh was applied by apparatus MTU 500H (Therapy System, Czech Republic). It was administered 10 doses; once daily for 20 min, with a frequency of 4.5 Hz and a magnetic induction 3 T. The initial 3 doses were about 25% lower then the later doses. PETh was very effective in patients with COPD. The measured indexes improved about 200-660 ml or ml x s(-1), except FVC. PETh was less effective in asthmatics. Most indices improved without statistical significance, about 50-620 ml or ml x s(-1). The indices of FEV1/FVC and MEF25 deteriorated. The changes in controls without PETh were very small. (Tab. 2, Fig. 1, Ref. 19.)

Adult↗

The effects of electromagnetic fields from power lines on avian reproductive biology and physiology: a review.

Electrical power lines are ubiquitous in the developed world and in urban areas of the developing world. All electrical currents, including those running through power lines, generate electric and magnetic fields (EMFs). Electrical power lines, towers,and distribution poles are used by birds for perching, hunting, and nesting. Therefore, many bird species, like humans, are exposed to EMFs throughout their lives. EMFs have been implicated in adversely affecting multiple facets of human health,including increasing the risks of life-threatening illnesses such as leukemia, brain cancer, amyotrophic lateral sclerosis, clinical depression, suicide, and Alzheimer's disease. A great deal of research and controversy exists as to whether or not exposure to EMFs affects the cellular, endocrine, immune, and reproductive systems of vertebrates. Laboratory work has used mice, rats, and chickens as models for this EMF research in an effort to understand better the possible implications of EMF exposure for humans. However, EMF exposure of wild birds may also provide insight into the impacts of EMFs on human health. This review focuses on research examining the effects of EMFs on birds; most studies indicate that EMF exposure of birds generally changes, but not always consistently in effect or in direction, their behavior, reproductive success, growth and development, physiology and endocrinology, and oxidative stress under EMF conditions. Some of this work has involved birds under aviary conditions, while other research has focused on free-ranging birds exposed to EMFs. Finally, a number of future research directions are discussed that may help to provide a better understanding of EMF effects on vertebrate health and conservation.

Animals↗

Effects of 60 Hz electromagnetic field exposure on testicular germ cell apoptosis in mice.

AIM: To evaluate the effects of 60 Hz extremely low frequency (ELF) elelctromagnetic field (EMF) exposure on germ cell apoptosis in the testis of mice. METHODS: Adult male BALB/c mice (7 weeks of age) were exposed to a 60 Hz EMF of 0.1 mT or 0.5 mT for 24 h/day. A sham-exposed group served as the control. After 8 weeks of exposure, the mice were sacrificed. Germ cell apoptosis in the testis was assessed by histopathological examination, the terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling assay (TUNEL) and flow cytometric examination of isolated spermatogenic cells stained with 7 aminoactinomycin D (7-AAD). RESULTS: EMF exposure did not significantly affect the body and testis weights, but significantly increased the incidence of germ cell death. The distinguishing morphological feature of EMF exposure was a decrement in the number of well organized seminiferous tubules. Quantitative analysis of TUNEL-positive germ cells showed a significantly higher apoptotic rate in the 0.5 mT exposed mice than that in the sham controls (P<0.05), while the difference between the two exposed groups was insignificant. The TUNEL-positive cells were mainly spermatogonia. In flow cytometry analysis, the percentage of live cells [forward scatter count (FSC)(high)7-AAD(-)] was lower in the exposed groups than that in the controls (Figure 5A), but the decrease in viability was not statistically significant. CONCLUSION: Continuous exposure to ELF EMF may induce testicular germ cell apoptosis in mice.

Animals↗

Photoperiodism as a modifier of effect of extremely low-frequency electromagnetic field on morphological properties of pineal gland.

The aim of our study was to determine, using histological and stereological methods, whether photoperiodism has any impact on the effects that chronic (three-month long) exposure to LF-EMF (50Hz) has on morphological characteristics on rat's pineal gland. The experiment was performed on 48 Mill Hill male rats (24 experimental and 24 control). Upon birth, 24 rats were exposed for 7h a day, 5 days a week for 3 months to LF-EMF (50 Hz, 50-500microT, 10V/m). In the winter (short days, long nights), the activity of the pineal gland and neuroendocrine sensitivity is increased. The study was performed both during summer and winter, following the identical protocol. After sacrifice of animals, samples of pineal gland were processed for HE staining and then were analyzed using the methods of stereology. The most significant changes in epiphysis in the first group of animals in wintertime are: altered glandular feature, hyperemia, reduced pinealocytes with pale pink, poor cytoplasm and irregular, stick-form nuclei. In the second group (II) pinealocytes are enlarged, with vacuolated cytoplasm and hyper chromatic, enlarged nucleus. Morphological changes of pineal gland at rats in the summertime were not as intense as in the winter and finding of the gland in the group II is compatible with those from the control group. Stereological results show both in winter and summer in the first group the decrease of volume density of pinealocytes, their cytoplasm and nuclei and in the second group in winter increase the volume density of pinealocytes, cytoplasm and nuclei, while in the second group the results in summertime are equal to those from the control group. Photoperiodism is modifier of effect of LF-EMF on morphological structure of pineal gland, because the gland recovery is incomplete in winter and reversible in summer.

Animals↗

Whole-body exposure to 2.45 GHz electromagnetic fields does not alter anxiety responses in rats: a plus-maze study including test validation.

In a first phase of this investigation, a validation of our elevated plus-maze apparatus was performed in male Sprague-Dawley rats by testing anxiety response at various ambient light intensities (200, 30, 10 and 2.5 lux), as well as the effects of diazepam treatment (0.5 and 1.0 mg/kg, i.p. at 30 lux). Anxiety responses were found to decrease with decreasing light intensity and to be attenuated by diazepam treatment. Subsequently, a separate set of rats was exposed to 2.45 GHz EMFs (2 micros pulse width, 500 pulses per second, whole-body and time averaged of SAR 0.6 W/kg +/-2 dB, brain-averaged SAR of 0.9 W/kg +/-3 dB) for 45 min to assess whether EMF exposure altered anxiety responses in the same apparatus. As we made no a priori hypothesis on whether the effects would be anxiogenic or anxiolytic, part of the rats were tested under an ambient light intensity of 2.5 lux, the other one being tested at 30 lux. The low intensity level set the behavioural baseline for the detection of anxiogenic effects, while the higher one corresponded to the detection of anxiolytic effects. Sham-exposed and naive rats were used as controls. Whatever light intensity was used, EMF exposure failed to induce any significant effect on anxiety responses in the plus maze. The present experiment demonstrates that exposure to EMFs, which was previously found to increase the number of benzodiazepine receptors in the rat cortex [Lai H, Carino MA, Horita A, Guy AW. Single vs. repeated microwave exposure: effects on benzodiazepine receptors in the brain of the rat. Bioelectromagnetics 1992;13(1):57-66], does not alter anxiety responses assessed in the elevated plus maze.

Animals↗

Interactive effect of chemical substances and occupational electromagnetic field exposure on the risk of gliomas and meningiomas in Swedish men.

The objective of our study was to investigate the possible interactive effect of occupational exposure to extremely low-frequency magnetic field (ELFMF) and to known or suspected carcinogenic chemicals on the incidence of the two main histological types of brain cancer, gliomas and meningiomas, in a cohort of male Swedish workers. The historical cohort of all Swedish men gainfully employed in 1970 were followed 19 years (1971-1989). Exposure to ELFMF and to nine chemicals were assessed using two Swedish job exposure matrices based on occupational codes and industrial activity. Relative risks adjusted for age, period, geographical area, and town size were computed using log-linear Poisson models. The main finding was the absence of ELFMF effect on glioma risk in the absence of a simultaneous exposure to chemical products. The effect of petroleum products was independent of the intensity of ELFMF exposure whereas solvents, lead, and pesticides/herbicides were only associated with glioma in workers also exposed to moderate or high levels of ELFMF. On the other hand, whereas ELFMF seemed to enhance the effect of specific chemicals in the causation of gliomas, we did not find a relationship between ELFMF exposure and meningiomas. The potential for ELFMF to act as an effect modifier of the association of chemical agents and glioma is an interesting new finding. It would be worthwhile to evaluate this hypothesis for other tumors. Also, it is necessary to confirm these results in epidemiological studies with individual exposure assessments, and in experimental studies that may elucidate whether there is a true causal mechanism for the results we observed.

Adult↗

Occupational exposure to electromagnetic fields and risk of Alzheimer's disease.

BACKGROUND: Extremely-low-frequency magnetic field (ELF-MF) exposure is suspected to increase the risk of Alzheimer's disease. Such fields are present in the vicinity of electrical motors and other electric appliances containing coils. METHODS: We investigated lifetime occupational ELF-MF exposure in relation to Alzheimer's disease and dementia among a community dementia-free cohort (n = 931) age 75 years and older in Stockholm, Sweden. This cohort was followed from 1987-1989 until 1994-1996 to detect dementia cases (Diagnostic and Statistical Manual of Mental Disorders, revised 3rd edition criteria). Information on lifetime job history was obtained by interview, usually of next of kin. ELF-MF exposure was assessed using a job-exposure matrix, measurement on historical equipment, and expert estimation. We analyzed the data with Cox models controlling for potential confounders. RESULTS: Dementia was diagnosed in 265 subjects, including 202 with Alzheimer's disease. Among men, ELF-MF exposure > or=0.2 microT in lifetime principal job was related to multivariate-adjusted relative risks of 2.3 (95% CI = 1.0-5.1) for Alzheimer's disease and 2.0 (1.1-3.7) for dementia. We found no association among women. A similar sex-specific pattern was seen for the associations with average ELF-MF exposure throughout the work life. A dose-response relation was suggested in men, with multivariate-adjusted relative risks of 2.4 (0.8-6.8) for Alzheimer's disease and 2.5 (1.1-5.6) for dementia for the upper tertile of lifetime average exposure. CONCLUSIONS: Long-term occupational exposure to a higher ELF-MF level may increase the risk of Alzheimer's disease and dementia in men. Similar patterns were not seen in women, which may in part be the result of a greater exposure misclassification in women than in men.

Aged↗

Do cocarcinogenic effects of ELF electromagnetic fields require repeated long-term interaction with carcinogens? Characteristics of positive studies using the DMBA breast cancer model in rats.

The carcinogenic or cocarcinogenic potential of extremely low frequency (ELF; 50 or 60 Hz) magnetic fields (MFs) has been evaluated worldwide in diverse animal model systems. Though most results have been negative, weakly positive or equivocal results have been reported in several cancer models, including the rat DMBA (7,12-dimethylbenz[a]anthracene) model of mammary cancer. Based on the experimental conditions used in studies in which cocarcinogenic effects of ELF MF were found, it was recently proposed that MF exposure may potentiate the effects of known carcinogens only when the animals are exposed to both MF and carcinogen during an extended period of tumor development, i.e., when the carcinogen is given repeatedly during MF exposure. This review summarizes a series of experiments from our group, showing cocarcinogenic MF effects in the DMBA breast cancer model in rats, to test whether the above proposal is confirmed by existing data. Flux densities of 50 or 100 microT significantly increased the growth of mammary tumors, independent of whether DMBA was given in a single administration or repeatedly over a prolonged period. Thus, these data do not substantiate the hypothesis requiring repeated doses of DMBA during MF exposure. Instead, several other aspects of study design and experimental factors are identified that seem to be critical for the detection of cocarcinogenic effects of MF exposure in the rat DMBA mammary cancer model. These include the rat subline used, the dose of DMBA, the duration of MF exposure, the flux density, the background (sham control) tumor incidence, and the location of mammary tumors in the mammary gland complex. These and other experimental aspects may explain why some laboratories did not detect cocarcinogenic MF effects in the DMBA model. We hope that direct comparison of MF bioeffects in different rat sublines and further evaluation of other experimental differences between studies on MF exposure in the DMBA model will eventually determine which genetic and environmental factors are critical for potential carcinogenic or cocarcinogenic effects of ELF MF exposure.

9,10-Dimethyl-1,2-benzanthracene↗

Electromagnetic field strength levels surrounding electronic article surveillance (EAS) systems.

Electronic article surveillance (EAS) is used in many applications throughout the world to prevent theft. EAS systems produce electromagnetic (EM) energy around exits to create an EM interrogation zone through which protected items must pass before leaving the establishment. Specially designed EAS tags are attached to these items and must either be deactivated or removed prior to passing through the EAS EM interrogation zone to prevent the alarm from sounding. Recent reports in the scientific literature have noted the possibility that EM energy transmitted by EAS systems may interfere with the proper operation of sensitive electronic medical devices. The Food and Drug Administration has the regulatory responsibility to ensure the safety and effectiveness of medical devices. Because of the possibility of electromagnetic interference (EMI) between EAS systems and electronic medical devices, in situ measurements of the electric and magnetic fields were made around various types of EAS systems. Field strength levels were measured around four types of EAS systems: audio frequency magnetic, pulsed magnetic resonant, radio frequency, and microwave. Field strengths from these EAS systems varied with magnetic fields as high as 1073.6 Am(-1) (in close proximity to the audio frequency magnetic EAS system towers), and electric fields up to 23.8 Vm(-1) (in close proximity to the microwave EAS system towers). Medical devices are only required to withstand 3 Vm(-1) by the International Electrotechnical Commission's current medical device standards. The modulation scheme of the signal transmitted by some types of EAS systems (especially the pulsed magnetic resonant) has been shown to be more likely to cause EMI with electronic medical devices. This study complements other work in the field by attaching specific characteristics to EAS transmitted EM energy. The quantitative data could be used to relate medical device EMI with specific field strength levels and signal waveforms. This is one of several efforts being made by the FDA, the electronic medical device industry and the EAS industry to mitigate the potential for EMI between EAS and medical devices.

Electromagnetic Fields↗

Measurement of radiated electromagnetic field levels before and after a changeover to energy-efficient lighting.

An energy-efficient lighting retrofit at the Food and Drug Administration (FDA) Winchester Engineering and Analytical Center (WEAC) presented the opportunity to measure the electromagnetic (EM) environments in several rooms before and after changing the fluorescent lighting systems and to compare the changes in EM fields with the proposed standard EM immunity levels. Three rooms, representing the types of work areas in the laboratory, were selected and measured before and after the lighting changeover. Electric and magnetic field measurements were taken in the extremely low frequency (ELF), very low frequency (VLF), and radio frequency (RF) ranges of the EM spectrum. In 2 rooms, ELF electric fields were reduced and VLF and RF electric fields were increased as a result of the changeover to high-frequency fixtures. A third room received low-frequency, energy-efficient fixtures during this changeover, and this change resulted in only a slight increase of the ELF electric fields. The ELF magnetic fields were greatly reduced in 2 but only slightly reduced in the third room. No significant change was seen in VLF or RF magnetic fields for any of these rooms. Some field-strength measurements exceeded the proposed immunity levels recommended in the draft International Electrotechnical Commission standard IEC 60601-1-2 (rev. 2). The data show that increasing the separation distance from the fluorescent light fixtures greatly reduces the field-strength levels, limiting the potential for EM interference.

Electromagnetic Fields↗