Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Tooth Preparation”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99Linked to original sources

Influence of Erbium:YAG laser energies on the microleakage of Class V resin-based composite restorations.

PURPOSE: To evaluate the influence of three Erbium:YAG laser energies on the microleakage of Class V resin-based composite restorations. MATERIALS AND METHODS: 60 extracted human premolar teeth stored in 0.12% thymol solution were randomly allocated to three groups. Buccal and lingual box-shaped Class V cavities were prepared on each tooth. One cavity served as the control and was cut using a conventional diamond bur in a high-speed handpiece. The test cavity was prepared using a pulse repetition rate of 5 Hz with 1 of 3 pulse energies; 200 mJ, 240 mJ, and 300 mJ with a 100 mJ dentin finish. The cavities were restored with Scotchbond Multi-Purpose and Z100 and were finished immediately before being stored for 3 months in thymol solution at 37 degrees C. Following thermocycling between 5 degrees C and 55 degrees C for 240 cycles and a further 12 hrs storage, the teeth were immersed in a 2% aqueous solution of methylene blue for 24 hrs. They were then sectioned through the mid-point of the restorations in a bucco-lingual plane and dye penetration was scored as 0 (none) to 4 (to the axial wall) for the enamel and dentin margins of both sections. The worst score for each margin was used for statistical analysis using the Kruskal Wallis and Mann-Whitney U tests at P < 0.05. RESULTS: When the lased groups were compared, optimum sealing was achieved with energies of at least 240 mJ at the enamel margin and with energies no higher than 200 mJ to finish the dentin margin. However, while all the pulse energies compared favorably to the control group in enamel, a similar result was found only using the 300 mJ, with 100 mJ, finish at the dentin margins.

Aluminum Silicates↗

Biological restorations as an alternative treatment for primary posterior teeth.

A case of oral rehabilitation in a 4-year-old girl, in which the posterior teeth were restored using biological restorations, is described. The tooth fragments were selected from a bank of tooth tissues and bonded with dual-cure composite cement to prepared teeth. The results were satisfactory regarding retention, aesthetic and mastication, but disadvantages included long clinical appointments, laborious technique and possible fracture or degradation between the margins of the fragment and the tooth surface.

Child, Preschool↗

The template-VLC provisional restoration system.

The removal of tooth structure during preparation results in varying degrees of pulpal hyperemia. The ability of the pulpal tissue to respond either by recovery or degeneration depends in part upon the adequacy and fit of the provisional restoration. The response of the gingival tissue also depends on a large degree on the success of the temporary coverage. Provisional restorations are commonly given less attention and importance thereby biologic, mechanical, and esthetic considerations are not adequately met. Since a provisional restoration must be made or improvised during the same appointment in which the abutment teeth are prepared, costly chairside time most often leads to an unacceptable restoration. Failures such as color instability, color incompatibility, inappropriate anatomic contours, fractures, occlusal disharmony, changes in tooth position, gingival inflammation, and unhealthy periodontal conditions are usually encountered. A technique of fabricating an exacting provisional restoration with compliance to optimum quality is presented.

Composite Resins↗

Selection defines design.

The era of "extension for prevention" used restorative materials and cavity preparation designs in an attempt to arrest the caries process. In the new era of "prevention to eliminate extension," many of the old limitations are no longer applicable because of advances in research and technology. The advances in restorative materials and adhesive technology require the use of an adhesive design concept when considering restorative material selection, preparation designs, and adhesive protocol and placement procedures and techniques. This adhesive design concept has been instrumental in the paradigm shift from the principles of extension for prevention to an ultraconservative principle of prevention to eliminate extension. From the early onset of the disease to initial placement of the restoration, this modern philosophy has three clinical objectives: prevention, preservation, and conservation. The clinician should strive to preserve the maximum integrity of the natural dentition by preventing the placement of the initial restoration, preserving and conserving tooth structure during the preparation of restoration, and conserving the tooth and restoration by increasing the longevity of the restoration between replacements. This article describes an incremental layering technique that uses a conservative restorative adhesive design concept (adhesive preparation design and protocol) for preparing, restoring, and finishing a Class IV restoration, and it demonstrates how the selection of a small-particle hybrid composite influences the preparation design. CLINICAL SIGNIFICANCE Selection of improved restorative materials that simulate the physical properties and other characteristics of natural teeth in combination with an adhesive design concept and preoperative considerations during the diagnostic and treatment planning phases of the restorative procedures provide the framework that ensures the optimal development of an esthetic restoration while preserving, conserving, and reinforcing the tooth-restoration complex.

Color↗

Technical note: fluoride pre-treatment effects on microleakage of a resin bonding agent.

This pilot study reports the effect of fluoride pre-treatment of dentin and enamel on microleakage of a resin bonding agent. Pairs of circular class V cavities involving 50% enamel and 50% cementum were cut in 12 extracted third molars. Each tooth contained a control and a treatment cavity (matched-pair design). A stannous fluoride solution (0.717% SnF2, Gel-Kam, Scherer Laboratories, Dallas, TX) was applied to the entire treatment preparation of each tooth. A dentin resin bonding system (Scotchbond 2 with Scotchprep, a dentin primer, 3M Dental Products Div., St. Paul, MN) was applied per manufacturer's instructions. Silux resin (3M) was placed over the resin bonding agent, light-cured, and finished. The teeth were subjected to 500 temperature cycles between 5 and 55 degrees C. A silver nitrate staining technique was used for evaluation of microleakage. The mean leakage for the control was 2235 +/- 1146 microns, and 2105 +/- 1052 microns for the fluoride treatment sites. It is concluded, from this pilot study with small sample size, that pre-treatment with fluoride of dentin and enamel prior to the placement of a resin bonding agent produced no significant change in microleakage (Student's t test for paired samples, p = 0.6492).

Dental Bonding↗

[Effects of the method of mechanical root canal treatment on emergence of pain after endodontic management].

For assessment of tooth canal mechanical preparation method influence upon frequency of pain emergence after endodontic treatment, laboratory and clinical evaluation of sound tools of the Sonic system, ultrasound tools of the Satelec Suprasson system, full-wind tools of Pro Taper and System GT as well as handy K-files was performed. It was found that the least risk of pain emergence after endodontic treatment occurs with tooth canal widening by CrownDown technique because in this case the minimal amount of canal preparation products are educted into periodontal tissues.

Humans↗

Bonded amalgam restorations: using a glass-ionomer as an adhesive liner.

Due to the lack of adhesiveness of amalgam to tooth structure, several adhesive cements have been utilized in bonded amalgam restorations. This study evaluated whether Fuji-II glass-ionomer cement is an appropriate adhesive liner in bonded amalgam restorations. Two adhesive composite luting cements (Amalgambond Plus and Panavia-21) and Copalite cavity liner were compared. The study was conducted in two phases. In the first part, we quantitatively assessed the tensile bond strengths as well as the failure modes of amalgam bonded to human dentin, using different adhesive liners. In each group, the flat dentin surface was treated with the assigned adhesive cement with a Teflon mold, followed by condensation of amalgam (Valiant PhD) onto it. Each group's mean tensile bond strengths were recorded and the statistical analysis by one way ANOVA showed no significant differences among groups (p > 0.05). Similar to the fracture patterns of the Amalgambond Plus and Panavia-21 groups, the failure mode of Fuji-II group was predominantly adhesive fracture. In the second part, the fracture strengths of amalgam restored teeth were measured using different adhesive liners. Standard MOD cavities were prepared in each tooth except for the intact tooth group. After treatment with the assigned adhesives or varnish, the cavities were restored with amalgam. Fracture strengths were then measured and the fractured interfaces examined using a scanning electron microscope. The fracture strengths of the intact tooth, Amalgambond Plus, Panavia-21 and Fuji-II groups were significantly higher than those of the Copalite and prepared cavity without restoration groups (p < 0.01). Accordingly, Fuji-II glass-ionomer cement, when used as an adhesive liner of amalgam restoration, may effectively reinforce the remaining tooth structure and, therefore, enhance the fracture resistance of the amalgam-restored teeth.

Analysis of Variance↗

Fracture resistance of teeth restored with Class II composite restorations.

Teeth with large mesio-occlusal-distal cavity preparations fracture more easily than intact teeth. An intracoronal restoration capable of increasing tooth fracture resistance is desired. This in vitro study compared the fracture resistance of maxillary premolars restored with enamel bonding and dentin bonding. The effects of the type of curing system (chemical or photochemical) and marginal preparation (beveled or not) were also evaluated. Premolars restored with large MOD composite resin restorations were approximately twice as strong as the unrestored prepared tooth. However, all restored teeth were no more than half as strong as the intact tooth. Dentin bonded restorations were not significantly stronger than enamel bonded restorations.

Acid Etching, Dental↗

In vitro effectiveness of dental floss in plaque removal.

This study was designed to determine whether there was any measurable difference in the effectiveness of bacterial plaque removal between 4 commercially available dental flosses. By means of a highly standardized and controlled in vitro experimental model technique utilizing 50 freshly extracted third molars, the possibility of intra- and inter-individual variability was eliminated. Each tooth was individually mounted in a formatray block and the surface was finished to either a "planed" or "unplaned" surface configuration. The "planed" root surface (dentin) was achieved by using 600 grit wet-sandpaper for tooth surface reduction while the "unplaned" root surface was achieved by using 600 gift wet-sandpaper. The teeth were then individually processed to effect the growth of bacterial plaque (S. mutans) on the prepared surfaces. Each tooth was subsequently disclosed, flossed and photographed without interruption. The flossing was carried out on a flossing machine utilizing a controlled force of 50 g. A controlled direction of the stroke perpendicular to the long axis of the tooth, and a controlled frequency of flossing (2 strokes per trial) was used. The results of the clinical trials were evaluated utilizing Ektachrome slides of the previously flossed and disclosed tooth surfaces. The photographs were projected, measured, and statistically analyzed (Student t-test and paired t-test) for the effectiveness of plaque removal of the 4 dental flosses and the effect of root surface roughness on the ability of the flosses to remove bacterial plaque. It was found that on smooth, "planed" root surfaces, there were no measurable difference among the 4 flosses.(ABSTRACT TRUNCATED AT 250 WORDS)

Dental Devices, Home Care↗

In vivo energy dispersive X-ray fluorescence for measuring the content of essential and toxic trace elements in teeth.

The calibration and application of a facility, based on energy dispersive X-ray fluorescent analysis (EDXRF) using 109Cd as an excitation source, for in vivo and in vitro estimation of Ca, Pb, Sr and Zn in tooth enamel is described. During the in vivo measurements, the device ensures tissue protection of face and mouth cavity from radiation, and only a small part of tooth surface under study is irradiated. To calibrate the facility, the contents of Ca, Sr and Zn were analyzed simultaneously in the enamel of 50 teeth by EDXRF and instrumental neutron activation analysis (INAA). Standards prepared from powdered tooth enamel with additions of chemically pure lead compounds were used to calibrate for lead graduation. Enamel calcium is suggested as an internal standard during in vivo EDXRF of teeth. The content of enamel Sr, Zn and Pb was determined by EDXRF in 35 permanent intact teeth of teenagers and adults. It was shown that lead concentration didn't exceed 3 micrograms/g for all the teeth.

Adolescent↗

[A scanning electron microscopy study on morphological changes of Er, Cr: YSGG laser-cutted dental hard tissue].

OBJECTIVE: The purpose of this study was to evaluate the morphological changes of Er, Cr: YSGG laser irradiated dental hard tissues by scanning electron microscopy (SEM). METHODS: 12 freshly extracted premolars were treated with fissure bur, Er, Cr: YSGG laser at 4 watt, Er, Cr: YSGG laser at 6 watt, respectively, and then bisected transversally and longitudinally. The tooth slice were prepared with conventional methods and observed by SEM. RESULTS: Compared with fissure bur, laser treatment resulted in a rather scaly and rough surface. The sections were free of smear layer, with open dentinal tubules. No carbonization and thermal damages were observed. The laser at 6 watt appeared rougher than at 4 watt, occasionally caused micro-cracks. CONCLUSION: The utilizing of Er, Cr: YSGG laser can contribute to enhance the bond strength between restorative materials and dental hard tissues. It suggests that higher energy could be applied in cutting enamel, whereas the lower energy in dentin.

Dental Cavity Preparation↗

Early treatment of incipient carious lesions: a two-year clinical evaluation.

BACKGROUND: The purpose of this study was to quantify conservation of tooth structure and evaluate the efficacy of early treatment of questionable carious lesions in pits and fissures of posterior teeth using air abrasion followed by placement of preventive resin restorations. METHODS: Ninety-three patients with 223 questionably carious teeth, mainly with darkly stained pits and fissures, were recruited from general dentistry clinics. After baseline evaluation, each tooth was randomly assigned to either an early treatment or control group. The authors used air abrasion to investigate the pits and fissures of teeth in the early treatment group. The teeth were sealed and restored with a flowable resin-based composite. All teeth in both groups were examined at six-month intervals to clinically evaluate the quality of the restorations and the caries status of the control teeth. RESULTS: After two years, two of the 113 restorations in the early treatment group required further treatment because of penetrating stain at a margin. In the control group, 14 teeth required treatment because of caries. The mean weight of the impression material--a surrogate measure of volume of removed tooth structure--in preparations that extended into dentin in the early treatment group was 0.0260 grams compared with 0.0281 g in the control group. There was no statistically significant difference between the impression weights (P = .390). CONCLUSION: After two years of a proposed five-year study, the authors concluded that conservation of tooth structure was not substantiated by early treatment. CLINICAL IMPLICATIONS: Treating questionable carious lesions early may not conserve tooth structure.

Composite Resins↗

Preparation modifications for damaged vital posterior teeth.

The preservation of a severely damaged tooth with a cast restoration requires that the preparation be modified to make use of remaining tooth structure. Preexisting preparation features, such as boxes and isthmuses, and new ones, such as boxes, grooves, and pin holes, are employed to provide adequate retention and resistance. When destruction of coronal tooth structure exceeds one-half of the clinical crown, a pin-retained amalgam or composite resin core should be used to build up the tooth to receive a cast restoration.

Crowns↗

Preimpregnated, fiber-reinforced prostheses. Part II. Direct applications: splints and fixed partial dentures.

This article is the second in a series that describes the development, physical properties, and clinical applications of fiber-reinforced composite materials. The development of fiber-reinforced composite technology has opened new avenues for fabricating direct tooth replacements and splints that are esthetic and simple in design and execution and have the potential for excellent durability. Splinting techniques for hypermobile dentitions or postorthodontic retention and the replacement of anterior and posterior teeth using a groove preparation, a denture tooth, and a fiber-reinforced composite framework will be described.

Composite Resins↗

Molecular diagnosis of PMP22-associated neuropathies using fluorescence in situ hybridization (FISH) on archival peripheral nerve tissue preparations.

Charcot-Marie-Tooth (CMT) syndrome type 1 and tomaculous neuropathy, also called hereditary neuropathy with liability to pressure palsies (HNPP), represent two groups of neurological disorders with different subtypes, which can be distinguished at the molecular level. It is known that a 1.5-mb region on chromosome 17p11.2-12, which includes the gene for the peripheral myelin protein 22 kDa (PMP22), is duplicated in more than 95% of patients with CMT type 1A (CMT1A; gene dosage 3) and is deleted in about 90% of subjects suffering from HNPP (gene dosage 1). This duplication/deletion can be detected reliably by interphase-two-color fluorescence in situ hybridization (FISH). We report here a technique for extraction of nuclei from paraffin-embedded and cryofixed sural nerve biopsies for precise molecular diagnosis, employing interphase-two-color FISH in clinically diagnosed CMT1 or HNPP patients. Following this technique we were able to identify six CMT1A duplications in 13 clinically diagnosed CMT1 cases and five HNPP deletions in 6 clinically diagnosed HNPP cases; 8 control persons were included in this study. This is the first report on the use of FISH in the detection of 17p11.2-12 duplication and deletion in archival biopsy material.

Adolescent↗

[Effects of Anhidrin on dog's dental pulp in vivo].

The purpose of the article was to investigate in vivo effects of Anhidrin, a cavity cleansing agent, on dog's dental pulp. Following class V cavity preparation, with a depth referred to caries media, dentine walls were cleaned with Anhidrin. Cavity floor was lined with denatured dentine powder and permanently filled with silver amalgam. Animals were sacrificed after experimental period of 14, 45 and 90 days, respectively. Decalcified tooth sections were prepared by standard histologic technique stained with HE. The results achieved using light microscopy showed the most intensive changes in pulp tissue beneath cavity preparations treated with Anhidrin 14 days postoperatively, characterized with hyperaemia and bleeding in odontoblast and subodontoblast layer, reduction in odontoblast number and disturbed cell arrangement. In the second experimental period after 45 days, the changes were less expressed. Ninety days after the operation pulp tissue appeared in normal histologic structure of sound dental pulp, with significant layers of tertiary dentine beneath the area of cavity preparation and application of Anhidrin.

Animals↗