Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Multiplex”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99Linked to original sources

Combinatorial screening of enzyme activity by using multiplexed capillary electrophoresis.

Efficient and comprehensive screening of enzyme activity was accomplished in a combinatorial array of 96 reaction microvials. Quantitation of the extent of the reaction at well-defined time intervals was achieved by using 96-capillary array electrophoresis coupled with a multiplexed absorption detector. Capillary electrophoresis provides high separation resolution to isolate the product from the reactants. Absorption detection provides universal applicability to combinatorial screening. For the conversion of NADH to NAD+, the catalytic activity of LDH was confirmed to be the highest at pH 7. This scheme should be useful for high-throughput drug discovery, clinical diagnosis, substrate binding, as well as combinatorial synthesis.

Electrophoresis, Capillary↗

A battery-powered notebook thermal cycler for rapid multiplex real-time PCR analysis.

A compact, real-time PCR instrument was developed for rapid, multiplex analysis of nucleic acids in an inexpensive, portable format. The instrument consists of a notebook computer, two reaction modules with integrated optics for four-color fluorescence detection, batteries, and a battery-charging system. The instrument weighs 3.3 kg, measures 26 x 22 x 7.5 cm, and can run continuously on the internal batteries for 4 h. Independent control of the modules allows differing temperature profiles and detection schemes to be run simultaneously. Results are presented that demonstrate rapid (1) detection and identification of Bacillus subtilis and Bacillus thuringensis spores and (2) characterization of a single nucleotide polymorphism for the hereditary hemochromatosis gene.

Bacillus subtilis↗

Evaluation of three-dimensional microchannel glass biochips for multiplexed nucleic acid fluorescence hybridization assays.

Three-dimensional, flow-through microchannel glass substrates have a potential for enhanced performance, including increased sensitivity and dynamic range, over traditional planar substrates used in medium-density microarray platforms. This paper presents a methodology for the implementation of multiplexed nucleic acid hybridization fluorescence assays on microchannel glass substrates. Fluorescence detection was achieved, in a first instance, using conventional low-magnification microscope objective lenses, as imaging optics whose depth-of-field characteristics match the thickness of the microchannel glass chip. The optical properties of microchannel glass were shown, through experimental results and simulations, to be compatible with the quantitative detection of heterogeneous hybridization events taking place along the microchannel sidewalls, with detection limits for oligonucleotide targets in the low-attomole range.

Base Sequence↗

Sample multiplexing for greater throughput in HPLC and related methods.

We present a multiplexing scheme that pools samples for greater efficiency in analysis. The method involves arraying the samples in a matrix and then pooling along rows and columns of the array. Sample pools are analyzed instead of individual samples. The content of a given sample is found by the intersection of a row pool with a column pool. Since this simple pooling scheme can lead to ambiguities in assignments when many samples have the same species, we also suggest a supplementary or augmented pooling scheme, involving the use of pools along diagonals across the sample array, to resolve the ambiguities. We demonstrate the pooling scheme, with resolution of some simple ambiguities, using HPLC for the analysis of fluorophore-labeled amino acids.

Amino Acids↗

Multiplexed gene expression analysis using the invader RNA assay with MALDI-TOF mass spectrometry detection.

A mass spectrometric approach for measuring gene expression levels has been developed. This technique utilizes a signal amplification system and analysis by matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) mass spectrometry. Signal amplification from the targeted RNA employs a recently developed invasive cleavage assay that does not require prior PCR amplification. The assay uses a set of target-specific probes (oligonucleotides), which hybridize to the RNA being measured to create an overlap structure with a single-stranded flap. This flap is enzymatically cleaved and accumulates linearly in a target-specific manner. The products of the reaction, short DNA oligomers, are well suited for quantitative detection by MALDI-TOF mass spectrometry. Multiplexing is achieved by designing the assays so that reaction products for different mRNA targets have discrete masses that can be resolved in a single mass spectrum. Simultaneous analysis of human cytokine in vitro transcripts IL-1beta, TNF-alpha, and IL-6, with GAPDH as a reference standard, was used as a model system to demonstrate this novel method of gene expression analysis.

Gas Chromatography-Mass Spectrometry↗

An evaluation of a four-channel multiplexed electrospray tandem mass spectrometry for higher throughput quantitative analysis.

A four-channel multiplexed electrospray inlet system (MUX) coupled to a triple quadrupole mass spectrometer was investigated as a higher throughput approach to quantitative analysis. Four discrete samples may be simultaneously analyzed by virtue of a rotating sampler with a concomitant 4-fold increase in analytical throughput. Although absolute sensitivity was reduced using the MUX interface compared with analysis using traditional single electrospray interface, reproducibility of response was shown to be comparable. Source robustness was established for the analysis of both aqueous drug standards and drugs in biological media, and linearity of response for a test compound, diazepam, was demonstrated over 2 orders of magnitude. Analyte-dependent response differences were exhibited between the four channels of the interface, and this led to the overall conclusion that samples to be compared quantitatively must be analyzed through the same sprayer. In addition, each channel must be independently calibrated to afford true quantification. Should a deuterated internal standard be employed, however, quantitative comparisons can be made across channels. An HPLC pumping system providing individual back-pressure regulation to each channel was shown to provide adequate chromatography even in the event of a channel blockage. Furthermore, following multiple injections of biological samples onto the MUX interface, an eluent flow diversion was integrated into the first part of each analytical run. This served to prevent source fouling, and thus, no detrimental effects to response reproducibility or sensitivity were observed.

Clozapine↗

Affinity capture and elution/electrospray ionization mass spectrometry assay of phosphomannomutase and phosphomannose isomerase for the multiplex analysis of congenital disorders of glycosylation types Ia and Ib.

We report a new application of affinity capture-elution electrospray mass spectrometry (ACESI-MS) to assay the enzymes phosphomannomutase (PMM) and phosphomannose isomerase (PMI), which when deficient cause congenital disorders of glycosylation CDG-type Ia and type Ib, respectively. The novel feature of this mass-spectrometry-based assay is that it allows one to distinguish and quantify enzymatic products that are isomeric with their substrates that are present simultaneously in complex mixtures, such as cultured human cell homogenates. This is achieved by coupled assays in which the PMM and PMI primary products are in vitro subjected to another enzymatic reaction with yeast transketolase that changes the mass of the products to be detected by mass spectrometry. The affinity purification procedure is fully automated, and the mass spectrometric analysis is multiplexed in a fashion that is suitable for high-throughput applications.

Congenital Disorders of Glycosylation↗

Development of a multiplexed microcapillary liquid chromatography system for high-throughput proteome analysis.

Comprehensive proteome analysis requires the identification (and quantification) of the proteins in samples consisting of thousands of proteins spanning a range of abundance of several orders of magnitude. The currency of proteome analysis by mass spectrometry is the peptides generated by protein proteolysis. The high sample complexity of such samples requires a large separation capacity, which is commonly achieved by fractionation of the mixture followed by further serial separations of each fraction. The sample throughput of proteome analysis is therefore limited by the need to sequentially process large numbers of samples. We have developed a novel four-plexed microcapillary liquid chromatography system for automated, high-throughput separation of complex peptide samples. The system supports the concurrent separation of four different samples by directing identically split solvent-gradient flows into four microcapillary C18 columns. The simple design of the system achieves multiplexed separation without the need for extra solvent pumps. Peak resolution, reproducibility, and parallel separating capacity of the system were investigated using standard peptides. The applicability of the system to high-throughput protein expression profiling was demonstrated in qualitative and quantitative analyses of protein expression in S. cerevisiae grown on two different carbon sources using the isotope-coded affinity tag (ICAT) reagent and matrix-assisted desorption/ionization quadrupole time-of-flight mass spectrometry.

Chromatography, High Pressure Liquid↗

Chemical imaging of surface reactions by multiplexed capillary electrophoresis.

A new technique for in situ imaging of surface reactions and screening heterogeneous catalysts by using multiplexed capillary electrophoresis was developed. By bundling together the inlets of a large number of capillaries, an aligned imaging probe can be created that can be used to sample directly products formed at a surface with spatial resolution determined by the outer diameter of the capillaries. In this work, we used surfaces made of platinum, iron, or gold wires to generate electrochemical products for imaging. Various shapes were recorded including crosses, squares, and triangles. A model multifunctional catalytic surface consisting of both iron and platinum electrodes in the shape of a cross was also imaged successfully. Each of the two wires produced a different electrochemical product that could be subjected to capillary electrophoresis to provide chemical selectivity. On the basis of the collected data, we were able to distinguish the products from each wire in the reconstructed image.

Journal Article↗

3D protein microarrays: performing multiplex immunoassays on a single chip.

The enzyme-linked immunosorbent assay (ELISA) is typically applied in the format of microtiter plates. To increase throughput and reduce consumption of precious samples, efforts have been made to transfer ELISA to the microchip format using conventional microarrays, microfluidic systems, and chips bearing microwells. However, all three formats lack the possibility to screen several analytes on several immobilized binders at a time or require complicated liquid handling, surface modifications, and additional equipment. Here, we describe an immunoassay performed on a standard microscope slide without the requirement for wells or tubes to separate the samples using standard surfaces and machinery already available for microarray technology. The new multiple spotting technique (MIST) comprises immobilization of a binder onto a surface and subsequent spotting of the second compound on the same spot, on top of the immobilized binder. We show that the analytes bind their ligands immediately within the confined space of separate droplets on the chip surface, thereby eliminating the need for extra incubation time. We illustrate the feasibility of the new technique by spotting dilution rows of proteins or monoclonal and polyclonal antibodies on top of their immobilized binders. Moreover, we demonstrate specificity by applying a mixture of antibodies in a multiplex format and demonstrate that the technique is compatible with conventional microarray protocols, such as total incubation. Finally, we indicate that the technique is capable of quantifying as little as 400 zmol (240,000 molecules) of analyte.

Antibodies↗

Autonomous detection of aerosolized biological agents by multiplexed immunoassay with polymerase chain reaction confirmation.

The autonomous pathogen detection system (APDS) is an automated, podium-sized instrument that continuously monitors the air for biological threat agents (bacteria, viruses, and toxins). The system has been developed to warn of a biological attack in critical or high-traffic facilities and at special events. The APDS performs continuous aerosol collection, sample preparation, and detection using multiplexed immunoassay followed by confirmatory PCR using real-time TaqMan assays. We have integrated completely reusable flow-through devices that perform DNA extraction and PCR amplification. The fully integrated system was challenged with aerosolized Bacillus anthracis, Yersinia pestis, Bacillus globigii, and botulinum toxoid. By coupling highly selective antibody- and DNA-based assays, the probability of an APDS reporting a false positive is extremely low.

Aerosols↗

Electrochemical coding for multiplexed immunoassays of proteins.

An electrochemical immunoassay protocol for the simultaneous measurements of proteins, based on the use of different inorganic nanocrystal tracers is described. The multiprotein electrical detection capability is coupled to the amplification feature of electrochemical stripping transduction (to yield fmol detection limits) and with an efficient magnetic separation (to minimize nonspecific adsorption effects). The multianalyte electrical sandwich immunoassay involves a dual binding event, based on antibodies linked to the nanocrystal tags and magnetic beads. Carbamate linkage is used for conjugating the hydroxyl-terminated nanocrystals with the secondary antibodies. Each biorecognition event yields a distinct voltammetric peak, whose position and size reflects the identity and level, respectively, of the corresponding antigen. The concept is demonstrated for a simultaneous immunoassay of beta(2)-microglobulin, IgG, bovine serum albumin, and C-reactive protein in connection with ZnS, CdS, PbS, and CuS colloidal crystals, respectively. These nanocrystal labels exhibit similar sensitivity. Such electrochemical coding could be readily multiplexed and scaled up in multiwell microtiter plates to allow simultaneous parallel detection of numerous proteins or samples and is expected to open new opportunities for protein diagnostics and biosecurity.

Animals↗

Multiplexed colorimetric solid-phase extraction: determination of silver(I), nickel(II), and sample Ph.

This paper reports the design and ground-based testing of a multiplexed colorimetric solid-phase extraction (MC-SPE) platform for the rapid determination of multiple water quality parameters in a simple set of operational steps. Colorimetric solid-phase extraction (C-SPE) is an analytical platform that combines impregnated colorimetric reagents on a solid-phase extraction membrane and diffuse reflectance spectroscopy to quantify trace analytes in water. In extending C-SPE to MC-SPE, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple syringes have been designed, enabling the simultaneous determination of three different measures of water quality. Separate, single-parameter membranes, placed in a readout cartridge create unique, parameter-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. Performance evaluations of the MC-SPE platform were conducted using sample pH, silver(I), and nickel(II). Determinations of silver(I) (0.05-0.5 ppm) and nickel(II) (1.8-5.0 ppm) follow established C-SPE methods on reversed-phase extraction membranes using 5-(p-dimethylaminobenzylidene)rhodanine and dimethylglyoxime, respectively, as colorimetric reagents. Sample pH (2.5-5.0) is measured using an anion-exchange membrane impregnated with fluorescein. These determinations require approximately 120 s to complete using a total sample volume of 3.0 mL. The extension of MC-SPE to the determination of a greater number of analytes and its potential application to space and earth-bound monitoring needs are briefly discussed.

Journal Article↗

On-chip nanoliter-volume multiplex TaqMan polymerase chain reaction from a single copy based on counting fluorescence released microchambers.

A novel method for multiplex TaqMan PCR in nanoliter volumes on a highly integrated silicon microchamber array is described. Three different gene targets, related to beta-actin, sex-determining region Y (SRY), and Rhesus D (RhD) were amplified and detected simultaneously on the same chip by using three different types of human genomic DNA as the templates. The lack of cross-contamination and carryover was shown using alternate dispensing of mineral oil-coated microchambers containing template and those without template. To confirm the specificity of our system to beta-actin, SRY, and RhD genes, we employed the larger volume PCR samples to a commercial real-time PCR system, SmartCycler. The samples were cycled with the same sustaining temperatures as with the microchamber array. Instead of the conventional method of DNA quantification, counting the number of the fluorescence released microchambers in consequence to TaqMan PCR was employed to our chip. This simple method of observing the end point signal had provided a dynamic quantitative range. Stochastic amplification of 0.4 copies/reaction chamber was achieved. The microfabricated PCR chip demonstrated a rapid and highly sensitive response for simultaneous multiple-target detection, which is a promising step toward the development of a fully integrated device for the "lab-on-a-chip" DNA analysis.

Actins↗

Development of a multiplexed interface for capillary electrophoresis-electrospray ion trap mass spectrometry.

A four-channel multiplexed electrospray capillary electrophoresis interface has been developed. This new interface permits up to four capillary electrophoresis columns to be sampled sequentially by means of a stepper motor and a notched rotating plate assembly, which at any instant occludes all but a single sprayer. In this design, four sheath liquid electrospray probes are oriented in a circular array situated 90 degrees relative to one another. The rotating metal disk, which contains a one-quarter notch, is mounted to the stepper motor assembly and is located between the sprayers and the entrance aperture of an ion trap mass spectrometer. By using the data acquisition signal from the ion trap mass spectrometer, the scan event is synchronized with the rotation of the metal disk. With this device, four discrete sample streams can be simultaneously analyzed, resulting in a 4-fold increase in analytical throughput.

Electrophoresis, Capillary↗

Multiplexed detection of antibodies to nonstructural proteins of foot-and-mouth disease virus.

Liquid array technology was used to develop a multiplexed assay for the detection of antibodies to viral nonstructural proteins (NSPs), raised in cattle in response to infection with foot-and-mouth disease (FMD) virus. Two assays, one based on recombinant NSPs and the other on synthetically produced peptides, were developed and compared side-by-side. Serum samples from serial bleeds of cattle, each experimentally infected with one of the seven serotypes (C, A, O, Asia, SAT1, SAT2, SAT3) of FMD virus were analyzed. A distinct pattern in the detection of NSP antibodies and a close correlation of the recombinant protein and peptide-based assays were observed. The detection of antibodies to NSPs is a method to differentiate FMD-infected and FMD-vaccinated animals, and a high-throughput assay would be an invaluable tool in the case of an outbreak of FMD in North America, when emergency vaccination may be utilized to spare vaccinated, noninfected animals from slaughter and subsequent disposal.

Animals↗

Surface plasmon resonance imaging measurements of antibody arrays for the multiplexed detection of low molecular weight protein biomarkers.

This paper describes a simple methodology for the creation of high-density multiplexed antibody arrays on gold surfaces that can be used to detect low molecular weight protein biomarkers with surface plasmon resonance imaging (SPRI). A one-step carbonyldiimidazole (CDI) surface reaction was utilized to attach antibodies onto alkanethiol-modified gold surfaces and characterized with polarization modulation FT-IR reflection absorption spectroscopy. The CDI chemistry was then employed to create an antibody microarray with array element sizes varying from 750 microm down to 200 microm. As a demonstration, a three-component antibody array was employed to detect two clinically important protein biomarkers, beta2-microglobulin (11.8 kDa) and cystatin C (13.4 kDa). SPRI measurements could simultaneously detect both of these small unlabeled proteins with no cross talk at solution concentrations from 300 nM down to 1 nM. In addition, the adsorption strengths of these biomarkers onto an antibody array were measured with SPRI and compared to those obtained from the kinetic analysis of single-channel angle shift SPR measurements.

Antibodies↗

Multiplexed proteomic reactor for the processing of proteomic samples.

We report the development of a 96-well plate proteomic reactor for gel-free processing of minute amounts of complex proteomic samples. The device performs multiplexed trapping, enrichment, and biochemical processing of proteins, resulting in concentrated peptide solutions ready for mass spectrometric analysis. Individual wells on the reactor can process up to 2 microg of protein. We also report the coupling of the plate proteomic reactor with protein fractionation using size-exclusion chromatography for large-scale identification of proteins. To illustrate the potential of this approach, we separated 400 microg of MCF7 cell lysate using size-exclusion chromatography and processed 35 protein fractions on the reactor plate. Using stringent criteria when searching the data, a total of 875 unique proteins were identified. More relaxed searching conditions associated with a 1% false positive rate led to the identification of 2683 unique proteins, meaning that one protein was identified per 3-10 ng of total protein lysate loaded on the reactor plate.

Biomarkers, Tumor↗