Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99Linked to original sources

Operative stabilization of fracture dislocations of the sacroiliac joint.

Posterior fracture dislocations of the sacroiliac joint (crescent fracture) represent a subset of lateral compression pelvic fractures. The crescent fracture consists of a posterior iliac wing fracture with extension into the sacroiliac joint and a dislocation of the inferior 1/2 of the sacroiliac joint. The posterior superior iliac spine remains firmly attached to the sacrum by the strong posterior ligaments. As a result of this combination of bony and soft tissue injury, the hemipelvis is rotationally unstable, but because the sacrospinous and sacrotuberous ligaments remain intact the involved hemipelvis is stable to vertically applied forces. Operative stabilization is necessary to restore articular congruity of the sacroiliac joint, pelvic stability, and to allow early mobilization of the patient. Stabilization of the pelvis may be achieved through either an anterior or a posterior approach with or without transarticular fixation. A posterolateral approach to the crescent fracture and a method of stabilization using extraarticular fixation, intertable lag screws and outer table antiglide plates are described. The results of using this technique in 22 patients are reviewed.

Fracture Fixation, Internal↗

Shear fracture through the body of the axis vertebra.

STUDY DESIGN: Three cases of a previously undescribed body fracture of the axis vertebra are presented. OBJECTIVES: To describe the radiographic features of the fracture are described, and to point out the differences to other axis body fractures regarding the mechanism of injury, stability, and treatment. SUMMARY OF BACKGROUND DATA: Fractures involving the odontoid process usually are caused by indirect forces, and they are considered unstable injuries. Anderson and D'Alonzo Type III odontoid fractures usually are hyperflexion injuries. Superior articular process fractures with or without associated odontoid peg fractures are caused by lateral hyperflexion injuries. METHODS: Three cases of body fractures of the axis vertebra are described. These fractures occur in an oblique plane shearing off in one piece the odontoid process together with one of the superior articular processes. The fragment displaces anterocaudally, and the odontoid process tilts toward the affected side. RESULTS: All fractures were managed nonsurgically. The two displaced fractures did not reduce in traction, and they had united in the displaced position after the 12 weeks of halo treatment. One patient reported only minor problems, but showed radiologic evidence of facet joint arthritis at 20 months. The second patient was lost to follow-up after discontinuation of halo treatment at 12 weeks. The only undisplaced fracture was managed in a halo body jacket for 10 weeks. The patient was pain free and had regained a full range of movement at 7 months. CONCLUSIONS: The presumed mechanism of injury in the described fracture is one of asymmetrical axial compression. The fracture can be managed safely in a halo jacket.

Adolescent↗

Thoracolumbar spine injuries associated with vertical plunges: reappraisal with computed tomography.

Eighteen patients who had fallen or jumped, and who had sustained fractures of the thoracolumbar spine, were examined with high-resolution computed tomography (CT). Two distinctive patterns of fracture were demonstrated: compression, or wedge, fractures of the vertebral body were present in seven patients, but they were not associated with permanent neurological deficit; and burst fractures with sagittal cleavage into two fragments occurred in five of 11 patients, and they were associated with permanent neurological deficit. CT provided precise and unique information that aided in clinical decision making for this group of patients.

Fractures, Bone↗

Fracture patterns in thalassemia.

Of 61 patients with homozygous beta-thalassemia, 30 had fractures; the majority were single fractures. In three thalassemic families, multiple fractures were observed. Although fractures occurred mostly during the growth period, no epiphyseal fractures were found among the patients in the present study. Roentgenograms showed either horizontal or oblique fractures, frequently with compression, or linear fractures without displacement. No delay in fracture healing or residual gross bone deformities were noted, with the exception of fractures of the femoral neck. On the basis of clinical and scintigraphic examinations, four additional adolescent patients, excluded from this study, were suspected of having microfractures around their ankles and knees. In the future, with improvements in diagnostic methods, microfractures may be found often and recognized as a common source of acute pain about the knees and ankles of thalassemic patients.

Adolescent↗

[Percutaneous vertebroplasty: option of treatment for osteoporotic vertebral fracture].

Percutaneous vertebroplasty (PV) is a minimally invasive procedure used to treat focal pain from compressive vertebral fracture. The PV is indicated for the treatment of debilitating vertebral pain from osteoporotic vertebral fractures, metastatic disease (osteolytic), myeloma and hemagioma. We analyzed the results of PV at 18 vertebrae of 11 patients. In 90.9% there war significant pain relief. The return to their usual activities at the first month occurred at 77.8% of the patients. According to the literature review and our study, PV is a promising therapy for selected cases.

Adolescent↗

Monocortical non-compression miniplate osteosynthesis of mandibular angle fractures.

The technique of monocortical non-compression miniplate fixation of mandibular angle fractures is reviewed. A study of our first 50 patients treated using this technique reveals that consistent reduction and stabilization of these mandibular fractures can be achieved without the requirement for intermaxillary fixation. Such results were produced with minimal postoperative morbidity.

Adolescent↗

Geometric changes in the cervical spinal canal during impact.

SUMMARY OF BACKGROUND DATA: Although the extent of injury after cervical spine fracture can be visualized by imaging, the deformations that occur in the spinal canal during injury are unknown. STUDY DESIGN: This study compared spinal canal occlusion and axial length changes occurring during a simulated compressive burst fracture with the residual deformations after the injury. METHODS: Canal occlusion was measured from changes in pressure in a flexible tube with fluid flowing through it, placed in the canal space after removal of the cord in cadaver specimens. To measure canal axial length, cables were fixed in C1 and led through the foramen transversarium from C2-T1, then out through the base, where they were connected to the core rods of linearly variable differential transformers (LVDT). Axial compressive burst fractures were created in each of ten cadaveric cervical spine specimens using a drop-weight, while force, distraction, and occlusion were monitored throughout the injury event. Pre- and post-injury radiographs and computed tomography scans compared transient and post-injury spinal canal geometry changes. RESULTS: In all cases, severe compressive injuries were produced. Three had an extension component in addition to compression of the vertebra and retropulsion of bone into the canal. The mean post-injury axial height loss measured from radiographs was only 35% of that measured transiently (3.1 mm post-injury, compared with 8.9 mm measured transiently), indicating significant recovery of axial height after impact. Post-injury and transient height loss were not significantly correlated (r2 = 0.230, P = 0.16) demonstrating that it is not a good measure of the extent of injury. Similarly, mean post injury canal area was 139% of the minimum area measured during impact, indicating recovery of canal space, and post-injury and transient values were not significantly correlated (r2 = 0.272, P = 0.12). Mean post-injury midsagittal diameter was 269% of the minimum transient diameter and showed a weak but significant correlation (r2 = 0.481, P = 0.03). CONCLUSIONS: Two potential spinal cord injury-causing mechanisms in axial bursting injuries of the cervical spine are occlusion and shortening of the canal. Post-injury radiographic measurements significantly underestimate the actual transient injury that occurs during impact.

Biomechanical Phenomena↗

Compression fixation of peritrochanteric fractures and early weight bearing.

Forty-two patients with peritrochanteric fractures of the femur were treated by open reduction and internal fixation with a 95 degree A-Ocompression plate. In 30 of 42 patients (71%) resumption of weight-bearing was achieved by 4 weeks from the time of surgery. Compressive fixation devices have biomechanical advantages over other types of standard nail-plates.

Adult↗

Optimal orientation of transfixation screws across oblique fractures lines.

Torisonal, compression, and bending forces were applied to long oblique fractures of rabbit tibiae that were fixed with 2 screws in different positions. Torison, bending and compression tests were applied to the tibiae. Results for torsional load show that screws should be perpendicular to the fracture plane. For compressive load, screws should be fixed perpendicular to the long axis of the bone. When bending moments are applied in the same plane as the plane of the screws, there is no preferred position of the screws across the fracture. When bending moments are applied perpendicular to the plane of the screws, screws should be positioned perpendicular to the fracture plane.

Animals↗

Problems and pitfalls of compression fixation of long bone fractures: a review of results and complications.

The complications encountered in the compression fixation of 70 cortical long bone fractures are reviewed. The results represent the initial experience with the AO fixation equipment following its introduction to a centre with staff relatively untrained in the technique. Infection was the most serious complication, with a deep sepsis rate of 10.5 per cent, but fixation failure, delayed union and refracture also occurred. The various problems are discussed in detail and suggestions are made as to how they can be avoided.

Adolescent↗

[C1 lateral mass-C2 pedicle screws and crosslink compression fixation for instable atlas fracture].

OBJECTIVES: To evaluate the feasibility and reliability of C(1) lateral-mass screw-C(2) pedicle screw and crosslink compression fixation for Jefferson fracture. METHODS: Seventeen patients with atlas fracture, 12 males and 5 females, aged 42.5 (25 - 67), 4 of which with unstable atlas fracture, were treated. 11 cases underwent C(1) lateral mass and C(2) pedicle screws and crosslink fixation, 6 of which had axial instability and rupture of atlas transverse ligament, 1 had C(2) luminal fracture, and the other 4 had axial instability. With the assistant of regional anatomy study and fluoroscopy the C(1) lateral mass screw and C(2) pedicle screw were inserted properly. Connecting rods were applied into the two screws on each side. Crosslink between the two rods were applied, compressing to achieve the realignment of the C(1) lateral mass fracture and C(0)-C(1)-C(2) into anatomical position. C(1)-C(2) fusions with posterior bone graft were performed in the patients with axial instability or transverse ligament discontinuity. RESULTS: The operative time ranged from 90 to 176 min with an average of 124 min. The intra-operative blood loss ranged from 270 to 1200 ml with an average of 432 ml. Fluoroscopic examination was used for 18 seconds on average. There were no neurological deficits, vertebral artery related complications or other complications in all the patients. No neurological deficit was aggravated after the patient's mobilization with brace 5 days after operation. One case of vertebral artery rupture happened because of the use of electrocautery. The bleeding was stopped by the use of hemostatic sponge and bone cement without causing cerebral hemodynamic deficit. X-ray examination showed bone fusion and stability in all the patients three months after the operation. The restoration of the C(2) fracture was confirmed by CT scan. CONCLUSION: Osteosynthesis of the atlas by C(1) lateral-mass screw-C(2) pedicle screw and crosslink compression fixation is an ideal option for C(1) burst fracture with or without rupture of transverse ligament. The procedure allows a physiological reconstruction of the C(0)-C(1)-C(2) joint and short segmental solid fusion for Jefferson fracture.

Adult↗

[Value of local radiotherapy in treatment of osseous metastases, pathological fractures and spinal cord compression].

Local radiotherapy plays an important and responsible role in the management of bone metastases. The valence will be described according to the different treatment objectives in the sense of pain relief, remineralization and cord decompression. Radiotherapy schedules, aimed at the relief pain, need to take into consideration life expectancy. Patients with a reduced life expectancy could have a good high chance of achieving pain relief with a single dose of 8 Gy. Patients with a solitary metastasis, patients with a longer life expectancy and patients with a pathological fracture should be treated with 'curative' irradiation doses, aimed at killing the maximum number of tumor cells. In addition to pain relief, remineralization is also an important treatment goal. Conventional radiotherapy with doses of 40-50 Gy resulted in pain relief in 70-100% and in remineralization in 60-80% of the patients. Remineralization could not be accelerated by short-course fractionation courses, but resulted in faster pain relief. Short-course fractionation schedules are not indicated as a 'standard' treatment in the vertebral column. Surgery is the treatment of choice for immediate cord decompression and stabilization of a pathological vertebral fracture. Radiotherapy alone could decrease neurological impairment and is suitable for patients with gradual onset and progression of symptoms, no spinal instability and lesions of the cauda equina.

Bone Neoplasms↗

Internal fixation of proximal femur fractures: a biomechanical comparison of the Gamma Locking Nail and the Omega Compression Hip Screw.

The fracture fixation capability of the Gamma Locking Nail was compared with the Omega Compression Hip Screw using cadaver femurs with simulated intertrochanteric and subtrochanteric fractures. Loading of the femurs was done on an Instron machine. Fracture fragment motion was recorded at 100-lb loading increments using standard roentgenograms. Both forms of hardware exhibited sufficient structural integrity to carry loads up to 600 lbs. Fracture motion was generally greater with the Gamma Locking Nail, which appeared to suspend the proximal fragments above a pivot point defined by the distal locking screws. Compression of the fracture site under loading did not occur with the Gamma Locking Nail. The potential for iatrogenic fracture generation appeared greater with the Gamma Locking Nail. Additionally, no clear mechanical advantage was documented in the fracture patterns tested. A limited discretionary use of the Gamma Locking Nail is advised.

Bone Nails↗