Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Flow Injection Analysis”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99Linked to original sources

Flow-injection electrogenerated chemiluminescence detection of hydrazine based on its in-situ electrochemical modification at a pre-anodized platinum electrode.

In this paper. it was found that the enhancing effect of hydrazine on the weak electrogenerated chemiluminescence (ECL) signal of the electrooxidation of luminol at a pre-anodized platinum electrode was stronger than that of hydrazine at a bare platinum electrode. Based on this finding and the combination of this finding with a flow-injection technique, a novel, sensitive and selective ECL method for hydrazine was developed. Under the optimum experimental conditions, the relative ECL intensity was linear with hydrazine concentration over the range 2.0 x 10(-8) - 5.0 x 10(-5) mol L(-1), with a detection limit of 6.0 x 10(-9) mol L(-1).

Electrodes↗

Molecular imprinted polymer coated QCM for the detection of nandrolone.

An acoustic wave sensor coated with an artificial biomimetic recognition element has been developed to selectively screen for nandrolone in the liquid phase. A highly specific covalently imprinted polymer (MIP) was spin coated onto one electrode of a quartz crystal microbalance (QCM) as a thin permeable film. Selective rebinding of the nandrolone was observed as a frequency shift in the QCM for concentrations up to 0.2 ppm with the sensor binding shown to favour nandrolone over analogous compounds.

Anabolic Agents↗

Label dilution method: a novel tool for bioligand interaction studies using bead injection in the lab-on-valve format.

This work introduces a novel method, label dilution, which is analogous to the well-established isotope dilution method. The principle is tested on a model system of commercially available antibodies and protein-coated Sepharose beads and implemented using micro-bead injection in the lab-on-valve format. This micro-scale method uses a labeled form of the target molecule as an internal standard. Label dilution employs ratiometric measurements using the absorbance signals from the label and the target molecules for quantitative determination of an analyte. The label dilution method is shown to discriminate between selective and non-selective binding and provides a means for monitoring bioligand interactions in real time. With a detection limit of 470 ng of IgG, this method provides a sensitive, automated technique for the determination of low-level analytes in complex samples. This technique has been developed with the aim of using it to facilitate diabetes research in which the interactions between autoantibodies and the molecules they target are a central focus.

Autoantibodies↗

Antimony speciation by inductively coupled plasma mass spectrometry using solid phase extraction cartridges.

A novel and simple method for inorganic antimony speciation is described based on selective solid phase extraction (SPE) separation of antimony(III) and highly sensitive inductively coupled plasma mass spectrometric (ICP-MS) detection of total antimony and antimony(V) in the aqueous phase of the sample. Non-polar SPE cartridges, such as the Isolute silica-based octyl (C8) sorbent-containing cartridge, selectively retained the Sb(III) complex with ammonium pyrrolidine dithiocarbamate (APDC), while the uncomplexed Sb(V) remained as a free species in the solution and passed through the cartridge. The Sb(III) concentration was calculated as the difference between total antimony and Sb(V) concentrations. The detection limit was 1 ng L(-1) antimony. Factors affecting the separation and detection of antimony species were investigated. Acidification of samples led to partial or complete retention of Sb(V) on C8 cartridge. Foreign ions tending to complex with Sb(III) or APDC did not interfere with the retention behavior of the Sb(III)-APDC complex. This method has been successfully applied to antimony speciation of various types of water samples.

Antimony↗

Real-time determination of glucose consumption by live cells using a lab-on-valve system with an integrated microbioreactor.

This paper describes a microquantitative method for glucose determination in situ of living cells in real-time. In this novel technique adherent cells are cultured onto microcarrier beads and packed into a renewable microcolumn within a microsequential injection lab-on-valve system (microSI-LOV). Glucose sensing is performed through the use of a two-step, NAD-linked enzymatic process. The course of the assay is monitored in real-time, by absorbance of NADH at 340 nm. The microsequential assay based on plug/nozzle design has a linear dynamic range for glucose of 0.1 to 5.6 mM. The design of the (microSI-LOV) system allows the assay to be carried out using only 40 microL of the enzyme reagent and 3 microL of sample. The technique was tested on a murine hepatocyte cell line (TABX2S) adhered to Cytopore beads. Rapid cellular glucose consumption, in this technique, is facilitated by a high cell density, which allows a large number of cells (10(4)-10(5)) to be retained in a very small volume (3 microL). In turn, this cell density results in the rapid depletion of glucose from the cell medium over short time periods (< 2 min). In conjunction with the assay development, the plug/nozzle design and its ramifications on mixing in general are presented and discussed.

Animals↗

Anion exchanger as a reaction/separation medium-absorptiometric determination of trace amounts of boron in waters by on-line complexation with chromotropic acid presorbed on the anion-exchange column.

A novel method of on-line absorptiometric determination for trace amounts of boron was developed based on the complexation with chromotropic acid presorbed on an anion-exchange column. On-line reaction and separation were achieved by controlling pH conditions in solutions to accelerate the 1:2 complex formation in the concentration process at pH 3 and to stabilize the complex in the separation process at pH 8. About 75% of the boron introduced into the stream was kinetically collected as the 1:2 complex on the column under the experimental conditions. The 1:2 complex was satisfactorily separated from excess reagent and matrix components by changing the concentration of NaClO4 in the eluent and its peak height on the chromatogram monitored at 350 nm was used for calibration. The sensitivity could be enhanced by increasing the sample amount introduced and the detection limits (3sigma) were 162 ng dm(-3) and 45 ng dm(-3) of boron, when 5.0 cm3 and 13.4 cm3 of the samples were used, respectively. The method has been successfully applied to the determination of boron in samples of river water, tap water and ion-exchanged water.

Boron↗

Acoustic coupling of transverse waves as a mechanism for the label-free detection of protein-small molecule interactions.

An on-line acoustic transverse wave device has been used to study the binding interactions of human serum albumin with the small molecule drug, warfarin. Four linking systems for the covalent attachment of the protein to the surface of the gold electrode of the sensor were employed, namely thioctic acid, cysteamine, an N-hydroxysuccinimide ester and 11-mercaptoundecanoic acid. All the attachment protocols involve the ability of thiols to form gold-sulfur bonds at the metal surface. The functional group present at the distal end of each thiol was chemically activated in order to facilitate covalent attachment of the protein. On-line sensor measurements of acoustic parameters show that the binding of warfarin to the protein can be detected, and depending on the linking monolayer used three of four possible combinations of changes in series resonance frequency and motional resistance are observed. Calculations of possible mass and thickness viscoelastic effects demonstrate that these conventional notions are invalid in terms of an explanation of the acoustic signals observed for the warfarin-protein interaction. The responses are ascribed to acoustic coupling phenomena.

Electrochemistry↗

Study of carbon nanotubes-HRP modified electrode and its application for novel on-line biosensors.

In this paper, multi-walled carbon nanotubes (MWCNTs) were successfully immobilized on the surface of a glassy carbon electrode by mixing with horse-radish peroxidase (HRP). The electrochemical behavior of H2O2 was also studied with the MWCNTs-HRP modified electrode as a working electrode. The MWCNTs-HRP modified electrode showed excellent response of reduction current for the determination of H2O2 at the potential of -300 mV (vs. Ag/AgCl). We assembled the MWCNTs-HRP modified electrode in a thin-layer flow cell and the H2O2 solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the H2O2 sensor by adjusting the working potential and the pH of the buffer solution. The peak current increased linearly with the concentration of H2O2 in the range 3.0 x 10(-7) to approximately 2.0 x 10(-4) mol L(-1). The detection limit is 1.0 x 10(-7) mol L(-1) (S/N = 3). The interferences from ascorbic acid, uric acid and other electroactive substances can be greatly excluded since the sensor can be operated at -300 mV. Stability and reproducibility of the MWCNTs-HRP chemically modified electrode were also studied in this paper. Fabricated with glucose and lactate oxidase, the MWCNTs-HRP electrode was also applied to prepare the on-line glucose and lactate biosensors because of the high sensitivity for the determination of H2O2.

Biosensing Techniques↗

Trace humic and fulvic acid determination in natural water by cloud point extraction/preconcentration using non-ionic and cationic surfactants with FI-UV detection.

A preconcentration and determination method for humic and fulvic acids at trace levels in natural water samples was developed. Cloud point extraction was successfully employed for the preconcentration of humic acid (HA) and fulvic acid (FA) prior to the determination by using a flow injection (FI) system coupled to a spectrophotometric UV-Vis detector. The quantitative extraction of HA and FA within the pH range 1-12 was obtained by neutralization of the anionic charge on the humic substances with a cationic surfactant, hexadecyltrimethylammonium bromide (CTAB). This generated a hydrophobic species that was subsequently incorporated (solubilized) into the micelles of a non-ionic surfactant polyethylene glycol, tert-octylphenyl ether (Triton X-114). The FI method for HA and FA determination was developed by injection of 100 microl of the extracted surfactant-rich phase using an HPLC pump with spectrophotometric detection at 350 nm. A 50 ml sample solution preconcentration allowed an enrichment factor of 167. The limit of detection (LOD) obtained under the optimal conditions was 5 microg l(-1). The precision for ten replicate determinations at 0.2 mg l(-1) HA was 3.1% relative standard deviation (RSD), calculated from the peak heights. The calibration using the preconcentration system for HA and FA was linear with a correlation coefficient (r2) of 0.9997 at levels near the detection limits up to at least 1 mg l(-1). The method was successfully applied to the determination of HA and FA in natural water samples (river water).

Benzopyrans↗

Electrochemiluminescence enzyme immunoassay for TNT.

Details of an electrochemiluminescence (ECL) enzyme immunoassay for TNT (2,4,6-trinitrotoluene) are reported. The design and construction of a computer controlled flow injection electrochemiluminometer in which the immunoassays are carried out is described. This system is used to select and pump solutions through a flow cell, which contains a gold working electrode as part of a three-electrode arrangement. The deposition of a re-usable immunosorbent dextran surface anchored to a gold surface in the flow cell by chemiadsorbed thiol groups is described. Antibodies are labeled with the enzyme glucose oxidase and used in competitive immunoassays in which the separation step is carried out by concentrating unbound antibodies on the immunosorbent surface. Hydrogen peroxide generated by the enzyme label when glucose is pumped through the flow cell is detected using luminol ECL. Light intensity was inversely proportional to the concentration of TNT in the sample in the range 0-100 ppb. The results are compared with colorimetric ELISA's carried out using the same reagents, and potential for developing a portable instrument for use in the field is discussed.

Enzyme-Linked Immunosorbent Assay↗

A novel flow-through microdialysis separation unit with integrated differential potentiometric detection for the determination of chloride in soil samples.

In this paper, a novel and miniaturised flow-through dialysis-based potentiometric detector is proposed for the determination of chloride in soil samples. The outstanding feature of the designed unit is the integration of analyte isolation from matrix constituents via membrane separation with differential potentiometric detection. Two identical tubular all-solid-state Ag/AgCl ion selective electrodes (ISEs) were assembled respectively at the inlet and outlet of the acceptor channel. Thus, as a consequence of the continuous forward flow of solutions through the microdialyser the outlet tube becomes the indicator electrode for the analyte diffusate while the nested tube at the entrance serves as reference electrode. The effect of physical and chemical parameters on the mass transfer efficiency is discussed in detail and compared with conventional configurations involving downstream detection. The membrane morphology for optimum dialysis performance is also thoroughly evaluated in terms of thickness, porosity and molecular weight cut-off. Higher dialysis efficiency and reduction of dilution factors up to a value of 5 were attained by halting the recipient stream temporarily. Under the optimised conditions, a dynamic working range of 5-5000 mg l(-1) chloride with a linear interval between 10 and 5000 mg l(-1) (for 1 min stopped-flow and 200 microl sample volume), a repeatability better than 3.0% and a 3 sigma(blank) detection limit of 1.2 mg l(-1) chloride were the analytical figures of merit of the devised configuration. The potentiometric dialysis sensor features extreme tolerance to high molecular weight interfering matrix compounds (> 1000 mg l(-1) humic acid), which makes it specially suited for the interference-free potentiometric determination of chloride in soils containing high levels of organic matter. The miniature size, low-reagent consumption and high analytical throughput (25-40 h(-1)) also warrant its applicability to in-field monitoring or screening schemes. The accuracy of the measurements was assessed using ion-chromatography as an external reference method. A mean t-test showed no statistical differences between both methodologies at the 95% confidence level.

Chlorides↗

Determination of erythrocyte deformability and its correlation to cellular ATP release using microbore tubing with diameters that approximate resistance vessels in vivo.

A novel method is described for measuring the deformability of red blood cells (RBCs) in tubing whose diameters approximate forces encountered in vivo. Here, RBCs from rabbits are loaded into a 50 cm section of 75 microm id microbore tubing and connected to a syringe pump. This section of tubing is then connected to a 15 cm section of 25 microm id tubing. As buffer is pumped through the flow system, the RBCs are evacuated from both sections of tubing. However, the inability of the RBCs to move freely through the 25 mirom id section of tubing results in a buildup of cells at the inlet of this portion of tubing. The continued force output by the syringe pump results in a deformation of the RBCs until all of the cells are eventually evacuated from the flow system. It was found that a measurement of the time required to reach half of the maximum pressure (1/2 P(max)) may be used as an indicator of the RBC deformability. For a given sample, a simple buffer results in less time to reach 1/2 P(max) (6.9 +/- 0.2 s) than deformable RBCs (21.6 +/- 0.8 s). To verify that the increased amount of time to reach 1/2 P(max) is indeed due to the RBCs, various hematocrits of an RBC sample were investigated and, as expected, it was found that a 12% RBC hematocrit had a higher 1/2 P(max) value (26.0 s +/- 2.2 s) when compared to a 7% hematocrit (19.1 +/- 0.3 s). In addition, RBCs chemically stiffened with glutaraldehyde were shown to be 25% less deformable than normal RBCs. Finally, a study was performed to examine the relationship between RBC deformability and ATP release and it was found that ATP release increased as a function of RBC deformability. This method greatly simplifies deformability measurements, employing only a syringe pump and microbore tubing, and may lead to a more complete understanding of the physiological significance of erythrocyte deformability.

Adenosine Triphosphate↗

Determination of trace concentrations of dissolved nitric oxide in a biological buffer.

A new real-time method for measuring a trace concentration of nitric oxide (NO) in a complex matrix routinely used in pharmacological studies of its bioactivity is described. NO was quantified as a gas by chemiluminescence after extraction from a continuous liquid sample flow with a limit of detection of 0.042 nmol dm(-3) at a signal to noise ratio of 3. Theories to calculate the concentration of NO in the liquid sample flow from a direct measurement of NO in the extraction carrier gas are presented. The efficiency of extraction is determined by a stopflow experiment. An example is presented of the measurement of the steady-state concentrations of NO in Krebs-bicarbonate buffer at pH 7.4 and 37 degrees C when its liquid surface is sequentially exposed to gases containing various concentrations of NO in O2 plus CO2.

Flow Injection Analysis↗

A novel approach for monitoring extracellular acidification rates: based on bead injection spectrophotometry and the lab-on-valve system.

Monitoring extracellular acidification rates (ECARs) is important for the study of cellular activities, since it allows for the evaluation of factors that alter metabolic function, such as stimulants, inhibitors, toxins as well as receptor and non-receptor mediated events. While the light addressable potentiometric sensor (Cytosensor Microphysiometer) has been the principal tool for ECARs measurement in the past, this work introduces a novel method that exploits an immobilized pH indicator on the surface of microcarrier beads (Sephadex) and is probed with a fiber optic coupled spectrophotometer. Likewise, live cells under investigation were also immobilized on microcarrier beads (Cytopore). These beads are metered, transported and monitored within a microfluidic system, termed as the Lab-on-Valve (LOV). Use of carrier beads in conjunction with Bead Injection Spectrophotometry and a Lab-on-Valve module (BIS-LOV), makes ECAR measurements reliable and automated. The feasibility of the BIS-LOV approach is demonstrated measuring ECARs of the mouse hepatocyte cell line, TABX.2S, grown on Cytopore beads packed within the central channel of the LOV system. These immobilized cells were perfused in a phosphate buffer carrier solution (capacity: 1 mmol L(-1), pH 7.4). Protons extruded from 10(5) to 10(6) cells were accumulated during a stopped flow period of 220 s followed by a pH measurement, detected by changes in absorbance of the pH indicator bonded to the microcarrier beads. Addition of metabolic inhibitors (sodium azide, oxamic acid) to the carrier buffer solution can induced an increase or decrease of the basal proton extrusion rate in a very reproducible manner. Comparison of the BIS-LOV technique to the Cytosensor microphysiometer and literature confirms the validity of this novel approach, highlighting its advantages and suggesting future improvements that will make the BIS-LOV a practical tool for routine ECARs measurement.

Animals↗

A general chemiluminescence method for the determination of surfactants based on its quenching effect on the luminol-NaIO4-cyclodextrin reaction.

Here we report that all types of surfactant could be simply and sensitively determined, by directly quenching the chemiluminescence (CL) between luminol and NaIO4 in a basic solution containing one polyhydroxyl compound such as cyclodextrin (CD), glucose or glycerol. This specific quenching effect was attributed to the change of the microenvironment of the CL reaction, caused by the addition of various surfactants. Based on this fact, the potential use of this CL reaction was exemplified by the cationic surfactant CTMAB, anionic surfactant SDS and non-ionic surfactant Triton X-100. It was found that the measurable range of CTMAB, SDS and Triton X-100 were 4.0 x 10(-6)-4.0 x 10(-4) M by using a basic CD-luminol-NaIO4 CL reaction. With our simple setup, CTMAB, SDS and Triton X-100 were detectable at a concentration as low as 2 microM. Overall, this new CL reaction is quite promising for the post-column determination of surfactant mixtures.

Animals↗

Development of a micro-fluidic manifold for copper monitoring utilising chemiluminescence detection.

The progressive development of a micro-fluidic manifold for the chemiluminescent detection of copper in water samples, based on the measurement of light emitted from the Cu(ii) catalysed oxidation of 1,10-phenanthroline by hydrogen peroxide, is reported. Micro-fluidic manifolds were designed and manufactured from polymethylmethacrylate (PMMA) using three micro-fabrication techniques, namely hot embossing, laser ablation and direct micro-milling. The final laser ablated design incorporated a reagent mixing channel of dimensions 7.3 cm in length and 250 x 250 microm in width and depth (triangular cross section), and a detection channel of 2.1 cm in length and 250 x 250 microm in width and depth (total approx. volume of between 16 to 22 microL). Optimised reagents conditions were found to be 0.07 mM 1,10-phenanthroline, containing 0.10 M cetyltrimethylammonium bromide and 0.075 M sodium hydroxide (reagent 1 delivered at 0.025 mL min(-1)) and 5% hydrogen peroxide (reagent 2 delivered at 0.025 mL min(-1)). The sample stream was mixed with reagent 1 in the mixing channel and subsequently mixed with reagent 2 at the start of the detection channel. The laser ablated manifold was found to give a linear response (R(2) = 0.998) over the concentration ranges 0-150 microg L(-1) and be reproducible (% RSD = 3.4 for five repeat injections of a 75 microg L(-1) std). Detection limits for Cu(ii) were found to be 20 microg L(-1). Selectivity was investigated using a copper selective mini-chelating column, which showed common cations found in drinking waters did not cause interference with the detection of Cu(ii). Finally the optimised system was successfully used for trace Cu(ii) determinations in a standard reference freshwater sample (SRM 1640).

Catalysis↗

Measurement of chemical oxygen demand (COD) in natural water samples by flow injection ozonation chemiluminescence (FI-CL) technique.

COD determination based on ozone oxidation of alpha-naphthol combined with UV radiation (UV-O3) has been studied in the present work. Utilizing the phenomenon that luminol can be oxidized by the dissolved ozone to produce luminescence, we have established a new method of utilizing aqueous chemiluminescence to determine COD. The kinetics and mechanism of the ozonation reaction of alpha-naphthol have been investigated in order to gain a better understanding of the general applicability and limitation of the technique. Real world samples were analyzed and the results show that the relative error of COD(FI-CL) measurement for water samples was < 10%. Compared with the results of the conventional potassium permanganate method, the COD values of the FI-CL method are consistently higher (0-20% relative). The higher COD values suggest that the ozone-UV system is a more effective oxidation technique.

China↗

On-line atmospheric pressure matrix-assisted laser desorption/ionization mass spectrometry.

A new technique is presented for the coupling of atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) mass spectrometry with liquid delivery systems. Mass measurements of polymers and peptides are demonstrated using a co-dissolved matrix, e.g. alpha-cyano-4-hydroxycinnamic acid (HCCA). Improvements in terms of sensitivity are achieved by optimizing the shape und control of the exit capillary and by using a laser (355 nm) at a 1 kHz repetition rate. Two calibration experiments promise a good applicability of the presented coupling method for quantitative measurements. The limit of detection achieved so far is 500 nM for peptides in methanol solution containing 25 mM HCCA.

Animals↗