Yad L'hakhlama (Reach to Recovery) in Israel.

"Yad L'hakhlama" (YL), initiated in 1967 as part of the Israel Cancer Association, is a national rehabilitation service for patients suffering from breast cancer. In Israel, about 1,000 new cases of breast cancer are diagnosed yearly and about 900 of the patients undergo mastectomy. YL reaches some 97% of these women. The office and central administration in Tel Aviv supervise the chapters in various cities. Eighty volunteers work in 26 hospitals throughout the country. Local and national card indexes of mastectomy patients are kept so that follow-up may be done by phone, through the mail or by additional counseling in the office. Assistance is given to the needy when necessary. YL keeps in contact with American and European manufacturers regarding prostheses and recommends imports to commercial agents for local supply. Fitters are selected and approved by YL, which also provides a temporary prosthetic device and a manual listing available accessories to all mastectomy patients. Lectures and information for professional and medical staff and students are given throughout the year. Some of the specific problems that YL handles are: 1) encouraging the acknowledgement and acceptance of the word "cancer" in certain hospitals and oncological centers, 2) overcoming the myths and superstition surrounding cancer; 3) improving doctor-patient relationships; and 4) recurrence of disease among the volunteers.

Adult↗

A new adhesive bonding material for the cementation of implantable devices in otologic surgery.

BACKGROUND: Presently, there are no U.S. Food and Drug Administration (FDA)-approved adhesive bone cements for the surgical fixation of prosthetic materials in the middle ear. A promising new cement, 4-META/MMA-TBB opaque resin, has shown remarkable adhesive properties as a bone cement in vivo. The cement is composed of 4-methacryloyloxyethyl trimellitate anhydride (4-META) and methyl methacrylate (MMA) as monomers and tri-n-butyl borane (TBB) as an initiator. METHODS: An electromagnetic semiimplantable hearing device presently under development was implanted into the middle ear of six cats using 4-META/MMA-TBB resin to cement a titanium-encased magnet to the incus. The animals were subsequently killed (at a mean of 9.6 months) to assess the (temporal bones and specifically the magnet-incus complex in each animal. RESULTS: The titanium-encapsulated magnet was firmly adherent to all incuses without any failure of the cement-bone interface. Histopathologic examination of the implanted temporal bones demonstrated lack of middle ear inflammation. Transmission electron microscopy of the incuses demonstrated a unique "hybrid layer" in the bone-side subsurface of the bone-cement interface that elucidates the mechanism of interfacial adhesion. CONCLUSIONS: Our investigation highlights the special biomechanical properties as well as the biocompatibility of 4-META/ MMA-TBB resin that make it an attractive bone-bonding agent for use in otologic surgery, including its potential usefulness during ossicular reconstruction.

Animals↗

Could interchangeable use of dry powder inhalers affect patients?

The aim of asthma treatment is optimal disease control. Poor asthma control results in considerable patient morbidity, as well as contributing to the considerable burden placed by the disease on healthcare budgets. There is a need for costs to be carefully scrutinised, with the switching of patients to inhaler devices with lower acquisition costs likely to be increasingly considered. However, before such practice becomes widespread, it is important to establish whether or not this could adversely impact on patients and the level of disease control. For approval to have been given, all marketed inhalers must have satisfied current regulatory requirements for devices. Full preclinical and clinical development programmes are not required when application is made for authorisation to market a new inhaler containing an existing chemical entity, although clinical equivalence testing must be used. Both beneficial and adverse effects should be tested, and the limits of equivalence must be clearly defined, based on therapeutic relevance. It should be noted that equivalence studies are invalid when the end point is not responding (i.e. at the top of the dose-response curve) and when equivalence limits approach or are equal to the magnitude of the drug effect. Approval on the basis of regulations designed to safeguard quality of dry powder inhalers does not mean that devices are interchangeable. When using an inhaler, there are many stages between the patient and the therapeutic effect, involving device design, pharmaceutical performance and patient behaviour. Regulations governing new devices cover only a few of the many factors affecting disease control. Furthermore, clinical trials to assess equivalence may not take into account factors in patient behaviour or variations in patient inhaler technique that may affect use of devices in real-life situations. When assessing the consequences of interchangeable use of dry powder inhalers on healthcare costs, it is important to ensure that the acquisition cost of the devices is not the only cost considered. Other costs that should be considered include the cost of time spent demonstrating to the patient how to use the new device, the cost of additional physician visits to address patient concerns and the management costs if disease control is adversely affected.

Administration, Inhalation↗

Histologic effects of laser-assisted topical anesthesia in a porcine model.

OBJECTIVES: A handheld laser device that removes the stratum corneum, the major barrier to transdermal absorption, has recently been approved to assist with topical anesthesia before painful procedures such as intravenous cannulation. The authors assessed the cutaneous histomorphologic effects of the laser device and the ability of the laser-treated skin to resist infection in a porcine model. METHODS: This was a blinded, randomized animal experiment using isoflurane-anesthetized young domestic pigs. The ventral surface of the animals was irradiated multiple times with a lightweight, portable erbium yttrium-aluminum-garnet unit or a sham laser. One third of the wounds were inoculated with a Staphylococcus aureus suspension. The treated areas were then covered with a dry dressing, and full-thickness biopsy specimens of the treated areas were obtained immediately after treatment and at three, seven, ten, and 14 days for blinded histopathologic evaluation using hematoxylin and eosin staining and electron microscopy. Quantitative bacterial counts were obtained at three days in wounds exposed to bacteria. Main outcomes were quantitative bacterial counts, presence of cellular necrosis, epidermal integrity, and dermal scarring. Data analysis was conducted with descriptive statistics. RESULTS: Laser irradiation resulted in immediate disruption of the cornified layer of the skin and necrosis of the stratum spinosum in all treated areas. There were also focal areas of vacuolar alteration of the basal one third of the epidermis. There was no evidence of any damage to the basement membrane or the underlying dermis. At three days, the epidermis had healed and there was evidence of epidermal hyperplasia and hyperkeratosis that was completely resolved by 14 days. There were no infections and no scarring. Sham laser had no histomorphologic effects on the skin. There was no bacterial growth from all sham laser-treated wounds challenged with bacteria. Three of 20 (15%; 95% confidence interval = 0% to 31%) laser-irradiated wounds that were challenged with bacteria grew between 280,000 and 1,600,000 colony-forming units/g. CONCLUSIONS: Laser irradiation results in ablation of the stratum corneum and a superficial burn to the epidermis that heals by three to 14 days without any scarring or infection in pigs. Challenging laser-irradiated cutaneous wounds with a large bacterial inoculum resulted in bacterial growth in a minority of wounds.

Administration, Topical↗

Legal implications of using drugs and devices in the dental office.

Choosing dental products that are FDA and/or ADA approved is a wise choice concerning their safety and efficacy for approved uses. However, the dentist must show that the product was indicated by a particular patient's needs. Uses of approved dental products in nonapproved ways or use of nonapproved products may be considered as negligence in some malpractice actions, but allowed under standards of reasonableness in other situations. The dentist must be able to justify decisions on a scientific basis. Legal ramifications of various decisions made in the context of difficult prescription choices are discussed.

American Dental Association↗

Diagnosis and treatment of impotence.

Among the common procedures used in the diagnosis of impotence, neither nocturnal penile tumescence testing nor inhome monitoring devices designed to measure tumescence or rigidity is regarded as reliable for evaluating impotence. Plethysmography as a nonspecific test of vascular competence is increasingly being supplanted by Doppler ultrasound as a safe and effective diagnostic modality. Arteriography, cavernosography, and cavernosometry are established techniques for evaluating penile vasculature. Intracavernosal injection of smooth muscle relaxing drugs, endocrine assays, and electrophysiological testing are widely used for the diagnosis of impotence. Excluding implanted devices, and intracavernosal injections. Aortoiliac reconstruction, endarterectomy, or arterial dilatations are regarded as safe and effective for the treatment of proximal occlusive lesions, and venous leakage surgery is regarded as investigational. Intracavernosal injections are widely employed in clinical environments and for self-injection at home. However, this currently represents the use of FDA-approved drugs for an unlabeled indication. The use of external vacuum devices has achieved widespread use and is regarded as being safe and effective for the treatment of impotence.

Angiography↗

Clinical evaluation of the Novacor totally implantable ventricular assist system. Current status.

The totally implantable Novacor left ventricular assist system (LVAS) is currently approaching clinical evaluation. In vivo testing and production are underway with National Institutes of Health (NIH) support. Activity over the past year has focused on manufacturing engineering, preproduction quality assurance, and in vivo experiment completion. Subsequent to successful completion of the NIH-sponsored, 2-year preclinical device readiness test (DRT), a number of refinements were identified and approved by the NIH technical/data review board. Most of these were necessitated by obsolescence or unavailability of electronic components and the decision to use only high reliability military (MIL) qualified electronic components and processes. A few additional refinements were identified to increase design margins, all of which were qualified by accelerated testing. The development of production processes, automated test programs, and MIL compliant environmental stress screening procedures was completed. Production of LVAS subsystems, including core electronic components (hybrids, application-specific integrated circuits, and surface mount boards), was initiated. Animal studies are underway. The clinical trial, at Presbyterian-University Hospital of Pittsburgh and St. Louis University Medical Center, awaits completion of in vivo experiments, protocol development, and Food and Drug Administration approval.

Electric Power Supplies↗

Nursing education and implications for left ventricular assist device destination therapy.

The HeartMate VE Left Ventricular Assist Device (vented electric abdominally positioned pulsatile blood pump; Thoratec Corp., Pleasanton, CA), approved as a permanent support, or destination therapy, by the US Food and Drug Administration in 2002 and Medicare in 2003, is now a potential therapy for numerous patients. Postimplantation nursing care is crucial to the success of left ventricular support device therapy and long-term recipient outcome. Nurses also contribute to cost containment, making this a viable treatment for the facility and the patient. Consequently, nurses must be educated about left ventricular assist device concepts and challenges, the benefits of device placement, intensive care unit and postintensive care unit daily care requirements, and outpatient preparation. This knowledge will enable nurses to provide necessary care and to educate recipients, families, and community health care providers on how to give appropriate posthospital care.

Certification↗

[Prevention of intraoperative hypothermia in children].

UNLABELLED: Children are very sensible to the occurrence of intraoperative hypothermia (HT) (core temperature < or = 36.0 degrees C) during general anaesthesia because their regulation capacity is less effective than in adults and due to a large skin-surface area compared with their body mass. We compared the efficacy of different heating devices to prevent HT in children during surgery. METHODS: With approval of the local ethics committee 50 children between one and seven years, scheduled for peripheral surgery lasting at least 2 hours were included in this study. Anaesthesia was standardized in all patients. Patients were randomly divided into 5 groups. In group 1, in addition to the usual cotton blankets, room temperature was elevated to 27-28 degrees C. In group 2, room temperature was maintained at 27-28 degrees C, and the patients were additionally wrapped into an aluminum blanket. In group 3, elevated room temperature was combined with a convective heating blanket. Patients in group 4 were warmed with an aluminum blanket, while the room temperature was maintained at 22 degrees C. In group 5, room temperature was maintained at 22 degrees C and patients were warmed with a convective heating device (Tab. 1). Room and core body temperature (tympanon membrane) were continuously measured. ANOVA and Fisher's exact Test (significance level: p < 0.05) were performed for the statistical analysis of the results. RESULTS: The demographic data of all 5 groups, the infused fluid volume and the anaesthetic technique were similar. There were no significant differences concerning age, height and weight of the pediatric patients (Tab. 2). The core temperature decreased by -1.7 degrees C in group 1. In group 4 core temperature decreased by -1.6 degrees C. Using a convective warming system in normal ambient temperature (group 5) core temperature increased by 0.2 degree C and was as effective in the prevention of HT as group 2. A significant increase in core temperature occurred in group 3 +0.7 degree C (Tab. 3 and Fig. 1). DISCUSSION: OR temperature seems to be a critical factor influencing heat loss. Increasing OR temperature and covering with cotton sheets was not effective in preventing the heat loss. Increasing room temperature in combination with aluminum sheets is one alternative to prevent HT. Our study shows that the use of a convective warming device prevents HT during a 2-hour surgery in young children even at a OR temperature of about 22 degrees C. In conclusion, in pediatric patients the use of a convective heating system proved to be an effective alternative to room heating.

Body Temperature↗

MED-EL Combi40+ cochlear implantation in adults.

OBJECTIVE/HYPOTHESIS: Cochlear implantation is currently the treatment of choice for severe to profound sensorineural hearing loss. The MED-EL Combi40+ (Innsbruck, Austria) cochlear implant system was approved for use in the United States in 2001. This device employs a 31-mm-long electrode array, ceramic case, and continuous interleaved sampling with Hilbert transformation for envelope extraction. A single institution's experience with the Combi40+ implant in adult patients was reviewed. STUDY DESIGN: Retrospective chart review. METHODS: Medical-surgical and audiological data were collected from 112 patients who received a MED-EL Combi40+ cochlear implant between December 1998 and April 2004. RESULTS: The rate of surgical complications and speech perception testing results compared favorably with those of other cochlear implant systems. For postlingually deafened adults, mean CNC word, HINTQ, CUNY, and HINT + 10 dB signal-to-noise ratio scores after 1 year of implant usage were 54%, 87%, 96%, and 64%, respectively. Prelingually deafened adults also derived significant benefit, but plateau performance for these patients was well below that for patients with later onset of deafness and significant variability was seen in this group. Repeat implantation for suspected device malfunction was undertaken in seven cases (6% of devices) (mean duration of use, 28 +/- 12 mo) with ultimate resolution of the presenting problem. CONCLUSION: The study results support the safety and efficacy of cochlear implantation with the MED-EL Combi40+ cochlear implant system.

Adolescent↗

Design of a synchrotron radiation source at Tohoku University.

The construction of a third-generation light source has been proposed at Tohoku University. The emittance is 7.3 nm rad at the nominal beam energy, 1.5 GeV. The circumference is 194 m. The ring consists of 12 double-bend achromatic cells. Ten of 12 dispersion-free long straight sections are 5 m long and will be used for insertion devices and some accelerator components. The remaining two are each 15 m long and reserved for advanced devices, such as a very long undulator or a free-electron laser. A stretcher-booster ring, which is now under commission, will be used as an injector. In total, about 50 beamlines can be constructed and ten of them will be those of insertion devices. The present status of the project is 'waiting for approval'.

Journal Article↗

Improving the quality of cervical screening.

OBJECTIVE: To compare the adequacy of cervical cytology sampling by a newly designed cervical cell sampler (the implement) with a commonly used, extended tip cervical scraper, namely the Jordan's spatula, by assessing the quality of cervical smears obtained. DESIGN: Prospective randomised controlled trial, with the approval of the local Ethics Committee after informing the Medical Devices Agency in the UK. SETTING: Colposcopy Clinic in a District General NHS Trust Hospital in London. POPULATION: Women attending the Colposcopy Clinic and having a good command of the English language (to avoid any misinterpretation of the information and enabling them to give informed consent) were invited to take part. Two hundred and twenty patients were recruited. METHODS: The women were randomised into two groups, each of them having two smears at the same time, half of them having their first smear with the Jordan's spatula and the other half having the first smear with the new implement. MAIN OUTCOME MEASURE: Good quality smears, assessed by evidence of effective sampling of the transformation zone, including immature metaplastic cells and also endocervical cells. RESULTS: Fifty-four percent of smears taken by the new implement showed good quality smears, compared with 37% taken by Jordan's spatula, a statistically significant result with P value <0.001. CONCLUSION: A larger number of good quality smears, judged by evidence of sampling of transformation zone and presence of endocervical cells, were obtained with the new implement. The difference was statistically significant. This would enhance the ability to detect dyskaryosis and increase adequate smear rates, reducing unnecessary recall of patients for repeat smears.

Colposcopy↗

The CE mark for implantable medical devices.

A vital aspect of device and implant regulation is continual surveillance of performance after approval. Most permanent implants seldom reveal their strengths and weaknesses until they have been in clinical use for a number of years. It is vital that clinicians report problems to the manufacturers and regulatory authorities to enable emerging hazards to be promptly identified.

Equipment Safety↗

Emerging therapies for female sexual dysfunction.

Epidemiological studies in the US, the UK and Sweden indicate that approximately 40% of women aged 18 - 59 have significant complaints about their sexual lives. The majority of complaints concern low sexual desire. Other common problems include difficulty reaching orgasm, insufficient lubrication and painful coitus. A vacuum erection device which increases blood flow to the clitoris has been approved by the US Food and Drug Administration. There are no pharmacological agents with approval for the treatment of female sexual dysfunction. Phosphodiesterase inhibitors and other drugs which cause genital vasocongestion in women appear to have minimal clinical efficacy. Although many of these agents increase the vasocongestive response to sexual stimulation, there is minimal correlation between subjective and objective measures of sexual arousal in women. Trials with androgens have clearly and convincingly demonstrated that supraphysiological doses of testosterone increase libido in postmenopausal women. The long-term safety of such doses is unclear. To date, no studies have shown lower doses of androgens to be beneficial. There have been minimal studies of drugs targeting the central nervous system to date. Bupropion may have a beneficial effect on orgasm attainment in women with hypoactive sexual desire disorder.

Androgens↗

[Hydration of patients treated with cisplatin: practical investigation and establishment of a protocol].

BACKGROUND: Administration of cisplatin requires hyperhydration of the patient to prevent nephrotoxic effects of this molecule. MATERIALS AND METHODS: A survey done in different hospitals - university hospitals, general hospitals and cancer institutes--has shown a large variability in the hydration protocols. A multidisciplinary group was set up in our university hospital comprising oncologists, nephrologists and pharmacists. This group has developed a consensual local protocol from a bibliographic analysis (Medline) and from the personal experience of each member. CONCLUSION: This protocol was approved by our hospital's Committee of Drugs and Medical Devices.

Cisplatin↗

The value of preoperative tests in the selection of blind patients for a permanent microelectronic implant.

PURPOSE: To determine the best candidates (ie, those requiring lowest current levels delivered to the retina to elicit visual perceptions) for long-term implantation of a microelectronic retinal implant through a series of preoperative visual, psychophysical, and electrophysiological tests. METHODS: This study protocol was granted an investigational device exemption by the Food and Drug Administration and was approved by the institutional review board at the University of Southern California. After informed consent was obtained, all subjects underwent the following preoperative tests: dark-adapted bright flash and 30-Hz flicker electroretinograms, electrical evoked responses (EERs) using a Burian-Allen corneal electrode to stimulate the globe, and psychophysical tests to evaluate the light and electrically elicited visual perceptions. Intraocular stimulation (IOS) of the retina was performed by an array of electrodes positioned on the internal limiting lamina. RESULTS: Lower vision correlated with less sensitive psychophysical responses (P<.0001). Lower vision and less sensitive psychophysical tests correlated with higher EER values for stimulus pulse widths of 2 ms (P<.0008) and 4 ms (P<.0002). Lower IOS currents correlated with more sensitive psychophysical responses (P<.02) and lower EER values at 4 ms (P<.04). CONCLUSIONS: Preoperative testing, especially psychophysical and electrophysiological tests to assess light and electrically driven visual responses, can help in evaluating patients for suitability for receiving a permanent microelectronic retinal implant. Further study is warranted.

Blindness↗

Poly-L-lactic acid: an overview.

In August 2004, the US Food and Drug Administration approved a poly-L-lactic acid (PLLA)-based injectable medical device for restoration and/or correction of the signs of facial fat loss (lipoatrophy) in people with human immunodeficiency virus. As a result, the properties of the PLLA microparticles have received considerable interest from the medical community. Polylactides have a long-standing history of safe use in medical applications, such as pins, plates, screws, intra-bone and soft-tissue implants, and as vectors for sustained release of bioactive compounds. The L-isomer of polylactic acid is a biodegradable, biocompatible, biologically inert, synthetic polymer. Putatively, PLLA microparticles initiate neocollagenesis as a result of a normal foreign-body reaction to their presence. The build-up of collagen over time creates volume at the site of injection, while the PLLA microparticles are metabolized to carbon dioxide and water and expelled through the respiratory system.

Absorbable Implants↗