Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,783 records · Page 99Linked to original sources

4-(9-fluorenylmethyloxycarbonyl)phenylhydrazine (FmPH): a new chromophoric reagent for quantitative monitoring of solid-phase aldehydes(1-3).

A direct method for quantifying solid-phase aldehydes has been developed, using a new reagent, 4-(9-fluorenylmethyloxycarbonyl)phenylhydrazine (FmPH). The FmPH reagent was synthesized in three steps (24% overall yield) from commercially available p-hydrazinobenzoic acid. Resin-bound aldehydes reacted quantitatively with FmPH, in the presence of trimethylorthoformate (TMOF) as a dehydrating agent, to form a highly conjugated, immobilized FmPH-hydrazone. Next, mild treatment of the hydrazone with an excess of piperidine-N,N-dimethylformamide (1:1) released the piperidine-dibenzofulvene adduct chromophore (epsilon(301nm) = 7800 M(-1) cm(-1)) from the support. FmPH quantitation of aldehydes proved to be a straightforward, sensitive, and reproducible technique for monitoring resin-bound aldehydes [albeit insufficiently reactive to allow reliable quantification of ketones]. The FmPH aldehyde assay is applicable to a range of solid supports, as demonstrated specifically for poly(ethylene glycol)-polystyrene (PEG-PS), aminomethylpolystyrene (AMP), and cross-linked ethoxylate acrylate resin (CLEAR).

Aldehydes↗

Effect of biological contamination on dentine bond strength of adhesive resins.

The purpose of this in vitro study was to determine the effect of saliva (S) and blood (B) contamination on the dentine bond strength of two single-component dentine bonding systems. The occlusal thirds of 120 recently extracted, human molars were removed with a low speed saw and subsequently embedded in Bencor rings by means of self-curing, acrylic resin. The occlusal surfaces were ground wet on 600-grit silicone carbide paper in a polishing machine to expose superficial dentine and to create a smear layer. The teeth were randomly divided into 12 groups (n = 10). All the dentine surfaces were etched with 34% phosphoric acid for 15 seconds rinsed with water, air-dried for 3 seconds, leaving the surfaces visibly moist. For the control groups (C) the etched dentine surfaces were treated with either, Scotchbond 1 (SB1, 3M) or Prime & Bond NT (PBNT, Dentsply) according to the manufacturer's instructions. In the contaminated groups, the saliva or blood was applied by means of a disposable brush, left undisturbed for 1 minute, and the excess then thinned by air spray. The dentine bonding systems were then applied, also according to manufacturer's instructions. Composite (Z250 and TPH) and Compomer (F2000 and Dyract AP (D-AP)) stubs were packed and cured incrementally to the corresponding pretreated dentine surfaces. All specimens were stored for 24 hours under water at 37 degrees C. The bonds were then stressed to failure with a Zwick testing machine, operating at a crosshead speed of 0.5 mm/min. Fractured samples were examined in a Scanning Electron Microscope. The data were statistically analysed (Student-t test). The mean SBS (MPa) were. SB1 with Z250: C = 19.1 +/- 4.4; S = 17.3 +/- 3.5; B = 2.6 +/- 0.9; SB1 with F2000: C = 11.8 +/- 3.3; S = 9.7 +/- 1.8; B = 4.7 +/- 1.6. PBNT with TPH: C = 9.2 +/- 3.2; S = 6.5 +/- 3.0; B = 4.3 +/- 1.5; PBNT with D-AP: C = 10.2 +/- 3.6; S = 9.3 +/- 2.9 and B = 7.3 +/- 2.5. There was no statistical significant difference in shear bond strengths between the control and the saliva-contaminated samples for both systems. There was, however, a significant difference in bond strengths between the control and the blood-contaminated samples. Blood contamination negatively influenced bond strength of bonding systems to dentine.

Blood↗

Evaluation of the Syntac bonding system.

The purpose of this in vitro study was to determine the shear bond strength [SBS] of Syntac to dentin; to determine the quantitative microleakage (ML) of Class V preparations in dentin restored with the Syntac system; and to study resin penetration into the dentin tubules by SEM. The occlusal surfaces of 30 extracted human mandibular permanent first and second molars were ground wet on 600-grit SiC to expose the superficial dentin. The teeth were embedded in brass tooth cups with cold cure acrylic resin. The Syntac Primer and the Syntac Adhesive were applied to the demarcated bonding sites as recommended by the manufacturer. Radiopaque Heliomolar was transferred to the opening in a split teflon mold in three increments, each compressed firmly and cured for 40 seconds. Fifteen of the test specimens were disassembled 60 seconds after cure [A], and the remainder 15 min after cure and the latter specimens stored in saline at 37 degrees C for 24 hours [B]. A shear load was applied at a crosshead speed of 0.5 mm/min, the SBS calculated and expressed in MPa. The data were analyzed by a two-sample t-test. Class V cavities were prepared on the facial surfaces of 15 human premolars and restored. The ML was determined quantitatively by a spectrophotometric dye recovery method and expressed as microgram dye/restoration. The mean +/- SD of the SBS in MPa were: A: 10.14 +/- 2.80; B: 15.90 +/- 2.13 and the ML 2.57 +/- 0.97 microgram dye/restoration. The SBS recorded after 24 hours storage was significantly greater than after 1 minute (P < 0.0001). The bonding resin penetrated deeply into the dentin tubules.

Composite Resins↗

Polymerization shrinkage-strain and microleakage in dentin-bordered cavities of chemically and light-cured restorative materials.

OBJECTIVES: The aim of this study was to evaluate in vitro the relationship between polymerization shrinkage and microleakage in dentin-bordered restorations. METHODS: Four light-cured restorative materials in combination with their respective dental bonding agents (DBA) were investigated: Tetric Ceram/Syntac classic (Vivadent), Solitaire/Gluma Solid bond (Heraeus Kulzer), Definite/Etch & Prime 3.0 (Degussa), Solitaire 2/Gluma Solid bond (Heraeus Kulzer). The chemically cured resin Degufill sc microhybrid (Degussa) in combination with ART Bond (Coltène) was also included. Polymerization shrinkage of the restorative materials was measured using three different methods (dilatometer, linometer, buoyancy method) and analyzed with ANOVA. For the determination of microleakage, caries-free human molars were embedded in acrylic resin and subsequently abraded with a wet abrasion machine to produce four level dentin surfaces. One hundred sixty cavities (3 mm diameter/1.5 mm deep) were randomly assigned to four groups of equal size. The groups were restored without (group 1 and 2) and with DBA (group 3 and 4), and either not subjected (group 1 and 3) or subjected (group 2 and 4) to 2000 cycles from 5-55 degrees C. Each group was further divided into five material subgroups of eight cavities each. Microleakage was determined using a dye penetration test assessed at depths of 200, 400 and 600 microm into the fillings. Data were analyzed with the Kruskal-Wallis and the Mann-Whitney test. RESULTS: All three methods of measuring polymerization shrinkage (PS) generated the same, statistically secured ranking for the four light-cured restorative materials: PS Definite < PS Tetric Ceram < PS Solitaire 2 < PS Solitaire. In the microleakage study, only a few statistically significant differences were observed. Etch & Prime 3.0/Definite in group 3 and Solid Bond/Solitaire 2 in group 4 tended to exhibit the least microleakage. Correlation coefficients between aggregated shrinkage and microleakage data were 0.3 for group 3 and -0.2 for group 4. SIGNIFICANCE: The results do not suggest any correlation between polymerization shrinkage and microleakage in dentin of direct adhesive restorations.

Analysis of Variance↗

Influence of different adhesive resin cements on the fracture strength of aluminum oxide ceramic posterior crowns.

STATEMENT OF PROBLEM: The influence of different types of adhesive resin cements on the long-term prognosis of aluminum oxide ceramic posterior crowns is unclear. PURPOSE: The purpose of this study was to evaluate the fracture resistance of aluminum oxide ceramic on maxillary posterior crowns cemented with different resin luting agents before and after cyclic thermomechanical loading. Material and methods Forty-eight maxillary first molars were prepared and restored with standardized aluminum oxide ceramic (In-Ceram Alumina) crowns. The test specimens were randomly divided into 3 groups (n=16). The crowns were luted with an acrylic resin cement (Super-Bond C&B, control, Group SB) and 2 composite luting agents (Panavia F, Group PV; and Rely X Unicem, Group RX). Half of the specimens were exposed to thermomechanical fatigue in a masticatory simulator. All specimens were tested for fracture strength (N) using quasistatic loading. The Wilcoxon rank sum test was used to compare the fracture strength (alpha=.05). RESULTS: All specimens survived the exposure to the simulator. The following median fracture strength values were obtained without/with thermomechanical fatigue loading: Group SB, 2726 N/2673 N; Group PV, 2520 N/2083 N; and Group RX, 2036 N/2369 N. The fracture strength in Group PV after thermomechanical fatigue loading was significantly lower compared to the fracture strength in Group PV without artificial aging (P =.016), as well as significantly lower compared to Group SB with artificial aging (P =.003). CONCLUSION: Within the limitations of this study, all tested cements are capable of successfully luting aluminum oxide ceramic crowns. The fracture strength of Group PV after artificial aging was comparatively low.

Compressive Strength↗

Do patients have a preference for major connector designs?

AIM: The aim of this research was to evaluate patients' preferences for resin analogs of four major connector designs formulated to have equal rigidity once fabricated in the same alloy. METHODS AND MATERIALS: Nineteen Kennedy Class I or II partially edentulous patients participated at two centers. The four major connector analogs (MCAs) were fabricated for each subject using light-polymerizing acrylic resin. The subjects were asked to wear each of them in the mouth for 30 seconds in six pairs in random order, and to report their preference for each pair. Based on these data, the four analogs were ranked in a descending preference order for each patient. Within-subject comparisons preferences were performed with the Friedman test, and the multiple comparisons were performed with the Wilcoxon Signed Ranks test for data of each sample independently. RESULTS: Statistically significant and consistent preference orders were revealed for both samples, and the thin and wide design was significantly preferred to the thick and narrow design. However, a higher variation was observed for the first preference of each subject. CONCLUSIONS: Subjects demonstrated a tendency to prefer thinner MCAs. However, the individual predilections of patients may not be an appropriate basis for an attempt to find a 'best design' applicable to all patients.

Dental Clasps↗

Dimensional change of impressions on sterilization.

The volume of impressions, before and after disinfection in a gluteraldehyde solution for longer than ten hours (that is, sterilization), was measured indirectly from dies produced from the impressions. Three elastomeric impression materials were used in both acrylic resin and poly-vinyl-chloride 'trays' to form the impressions. One impression material appeared to be practically superior to the others with respect to variability of volume. The effect of tray material on change in volume (calculated as after disinfection minus before disinfection) was significant for one impression material; acrylic trays produced the greatest effect. The change in volume was significant for two impression materials; acrylic trays were associated with greater increase in volume. It was concluded that if impressions are to be sterilized, a tray material having minimal potential to absorb disinfectant should be used.

Dental Impression Materials↗

Bond strength of a dentin bonding system using two techniques of polymerization: visible-light and argon laser.

OBJECTIVE: The aim of this work was to study one dentin-bonding system associated with posterior teeth restorative composite resin by means of tensile bond strength tests varying the technique of polymerization: visible light and argon laser. BACKGROUND DATA: Previous studies have demonstrated the ability of the argon laser to polymerize light-activated materials. METHODS: Sixty specimens were prepared by grinding the labial surface of bovine teeth embedded in acrylic resin. The dentin bonding system used was Single Bond (3M), which has a poliacenoic acid copolimer, associated with a posterior teeth restorative composite resin (Filtek P60, 3M). The bonding sites were treated according to the instruction of the manufacturers. The 60 teeth, duly embedded and ground, were assigned to four groups with 15 teeth each: group 1, the adhesive was light cured during 10 sec with visible light (Curing Light, 3M) with power density of 410 mW/cm2 and the composite resin was light cured during 20 sec with visible light; group 2, the adhesive and the composite resin were cured during 10 seconds with argon laser with 150 mW of power; group 3, the adhesive and the composite resin were cured during 10 sec with argon laser with 200 mW of power; and group 4, the adhesive and the composite resin were cured during 10 sec with argon laser with 250 mW of power. The composite resin was light cured in layers of 1 mm of thickness until the model of teflon with 3 mm in height was completely filled. RESULTS: The tensile bond strength test was performed in a Mini-Instron (model 4442) and the results for group 1 were 19.75 MPa (+/-4.65), group 2 were 16.09 MPa (+/-7.27), group 3 were 11.56 MPa (+/-4.50), and group 4 were 11.90 MPa (+/-5.78). CONCLUSIONS: One can conclude that the tensile bond strength promoted by the polymerization with visible light presented greater tensile bond strength than the polymerization with argon laser with 200 mW and 250 mW, but there was no significant difference between visible light and argon laser with 150 mW. There was no significant difference between argon laser with 150 mW and argon laser with 200 mW or 250 mW.

Animals↗

The effect of VLC Scotchbond and an incremental filling technique on leakage around Class II composite restorations.

The object of this study was to determine the effect of VLC Scotchbond and of an incremental filling technique on microleakage around class II composite restoration in vitro. Four groups of 15-16 teeth each, were filled with the resin P-30 by one of the following techniques: A, Scotchbond and incremental filling; B, Scotchbond and bulk filling; C, Enamel Bond and incremental filling; D, Enamel Bond and bulk filling. The teeth were thermocycled, insulated up to 1 mm from the restorations, immersed in 2 percent basic fuchsin, embedded in acrylic resin and ground off to various depths, parallel to the plane through the vertical and the mesiodistal axes. Marginal leakage was assessed from the degree of dye penetration at the sections. Dye penetration at the occlusal margins was similar for all groups. Dye penetration at the cervical margins for the different groups increased in the sequence: A/C/B/D. Incremental filling resulted in a significantly lower dye penetration at cervical margins for both bonding agents. The differences resulting from the use of Scotchbond were not significant, if the same packing technique had been used. Best results were obtained with Scotchbond and incremental filling.

Adhesives↗

Self-etching bonding systems: in-vitro micro-leakage evaluation.

The purpose of this in vitro study was to compare dentine and enamel micro-leakage values of six self-etching bonding agents to that of a total etch dentine bonding agent (used as a control). Products evaluated were Scotchbond Multipurpose Plus (3M/ESPE), Xeno III (Dentsply), Clearfil SE Bond (Kuraray), ABF (Kuraray), Optibond Solo Self-Etch (Kerr), OneCoatSE Bond (Colténe Whaledent), and iBond (Heraeus-Kulzer). Using a medium sized Cerana bur (Nordiska Dental) a standard, cylindrical preparation was made at the cemento-enamel junction (CEJ) of human third molars. The teeth were randomly divided into 7 groups of ten teeth each. The bonding agents were applied and light cured strictly according to the manufacturer's instructions and the cavities then filled in two increments, using Z100 composite (3M/ESPE). The restored teeth were imbedded in acrylic resin and thermocycled between 5 degrees - 60 degrees C (+/- 2 degrees C) for 250 cycles with a dwell time of 20 seconds. All seven groups were then placed in a 5% basic Fuchsin solution for 12 hours at 37 degrees C. The embedded teeth were removed from the basic Fuchsin, rinsed well, imbedded in acrylic and cut longitudinally through the centre of each restoration using an Accutom-2 cutting machine. Each tooth was then evaluated at the occlusal enamel margin and at the cervical dentine margin for micro-leakage using a light microscope at 50x magnification. The data obtained was analysed using the Kruskal-Wallis test, with Fisher's least significant difference method used for comparison of specific groups (p<0.05). When compared to the control (Scotchbond Multipurpose Plus), results for microleakage at the occlusal enamel margins as well as the cervical dentine margins indicated that only SE Bond and ABF (Protect Bond) showed values as low as the control. It can be concluded that, as far as micro-leakage is concerned, Clearfil SE Bond and ABF (Protect Bond) self-etching bonding agents could be clinically acceptable alternatives to the clinically proven Scotch-bond Multipurpose. The other products showed more microleakage.

Acid Etching, Dental↗

[Focus on post and cores].

Inspite of the new technics using composite resin, cast dowel and core is still used to replace lost coronal structure of endodontically treated teeth. Before the core preparation, an X-ray is essential. The metal used for the post and core must be the same as the one used later for the following full crown. Preparation methods must be well established. Acrylic resin or silicone may be used as impression technics.

Crowns↗

[Development of denture base resin. 2. Manufacturing of visible-light cured prepreg and physical properties of FRP].

To develop the visible light-cured FRP denture base, we investigated the physical properties and the warp of FRP plate by using various combinations of matrix resin and reinforcement. From the results of the bending test, hardness test and manipulation processing, the matrix resin of Bis-GMA/UDMA/3 G at 48/48/4 wt% was determined. The sateen weave's glasscloth as the reinforcement of the prepreg was used. The maximum plies included FRP of 0.5 mm, 0.8 and 1.0 mm thickness have the same maximum bending strengths of 45 kgf/mm2, which is about 5 times larger than that of conventional acrylic resin. The warp of these FRP plates were not found.

Bisphenol A-Glycidyl Methacrylate↗

Composite denture teeth made on a removable partial metal framework.

Most denture teeth and denture bases are made of polymethyl methacrylate, which does not chemically bond with a metal framework. The absence of a chemical bond leads to weak retention and high microleakage between the resin and metal interface. With a 4-META bonding agent, a chemical bond that increases retention and decreases microleakage can be created between the composite and the metal interface. This article describes a method for making composite denture teeth with a 4-META bonding agent. It can be done without costly equipment and can also be used to repair acrylic resin denture teeth.

Composite Resins↗

Dentin adhesion of "modified" 4-META/MMA-TBB resin: function of HEMA.

This study investigated adhesion to dentin of a modified 4-META/MMA-TBB resin (4-methacryloxyethyl trimellitate anhydride in methyl methacrylate initiated by tri-n-butyl borane) which does not require PMMA powder to polymerize. Ground bovine dentin specimens were pre-treated with an aqueous solution of 10% citric acid and 3% ferric chloride (10-3). This solution removes the smear layer and demineralizes the dentin, exposing collagen. Improved bond strengths were obtained when a HEMA-primer was applied to 10-3 pre-treated dentin. SEM examination revealed the formation of a transitional zone of resin-reinforced-dentin (hybrid layer) in 10-3 pre-treated, HEMA-primed samples. The adhesive monomer impregnated exposed collagen fibrils and, upon polymerization, became entangled with them to create the hybrid layer, essential in achieving significantly high tensile bonding strengths. HEMA enhanced the penetration capability of dentinal substrates. After polymerization and formation of the hybrid layer, auto-cured acrylic resin, photo-cured composite and amalgam were all capable of adhering to the dentin. The modified 4-META/MMA-TBB resin created significant adhesive bonds to 10-3 pre-treated ground bovine dentin.

Adhesiveness↗

Shear bond strengths and microleakage of four types of dentin adhesive materials.

The aim of this investigation was to compare the microleakage of composite resin (Z-100) and shear bond strength to bovine dentin using different types of adhesive systems (Scotch Bond Multi-Purpose, All-Bond 2, One-Step, and Perma Quick) to compare and correlate microleakage to shear bond strength. For the microleakage aspect of the study, 20 class V were prepared (bovine incisors) with 90-degree cavosurface margins and were located at the cemento-enamel junction using a template. Each dentin bonding system was applied to five cavities following the manufacturer's instructions and restored with Z-100 composite resin. After 24 hours of storage in distilled water at 37 degrees C, the teeth were immersed in 2% basic fuchsin dye. All teeth were sectioned in a mesiodistal direction using a diamond saw, and each section was then inspected under a stereomacroscope. For the shear bond strength aspect of the study, 20 bovine incisors were centrally horizontally mounted in Teflon mold with cold cure acrylic resin. Flat labial dentin surfaces were prepared using different grit silicon carbide abrasive wheels. Five specimens were used for each of the bonding agent systems. Each specimen was bonded with restorative composite resin (Z-100) and applied to the treated dentinal surface through a split Teflon mold. All specimens were stored in distilled water at 37 degrees C for 24 hours. The bonds were stressed using shear forces at a crosshead speed of 0.5mm/min using an Instron Universal testing machine. Findings indicate none of the systems tested in this study were free from microleakage. Scotch bond multi-purpose achieved the best seal, with One-Step being second best, while All-Bond 2 and Perma Quick had the poorest seal. However, there were significant differences among the shear bond strengths of the four bonding systems tested. Scotch Bond Multi-Purpose has a higher bond strength to composite resin when compared to the other dentin adhesives. The study also concluded there is no association between microleakage and shear bond strength.

Analysis of Variance↗

Bond strengths and SEM morphology of dentin-amalgam adhesives.

PURPOSE: To compare two one-bottle dentin bonding systems (DBS) with five multi-bottle DBS and one resin-modified glass-ionomer cement, regarding their ability to bond spherical amalgam to freshly prepared dentin surfaces, in vitro. The tested hypothesis was that one-bottle DBS would result in lower shear bond strengths than multi-bottle DBS. MATERIALS AND METHODS: Eighty flat dentin bonding sites were prepared to 600-grit on middle dentin of caries-free human molars mounted in acrylic resin. The bonding surfaces were treated with eight different bonding systems, according to manufacturer's instructions: All-Bond 2; Amalgambond Plus; Fuji Duet; One-Step/Resinomer; OptiBond; OptiBond FL; Prime & Bond 2.0/Dyract Cem; and Scotchbond Multi-Purpose Plus. A spherical amalgam alloy (Megalloy) was hand-condensed on the treated surfaces. After thermocycling, the bond strengths were calculated by testing the specimens in shear. Field-emission SEM examinations were carried out to evaluate the effects of different treatments on the dentin-amalgam interface of MO/OD cavities treated under the same protocol. RESULTS: Statistical analysis revealed that Prime & Bond 2.0/Dyract Cem, Amalgambond Plus, and Scotchbond Multi-Purpose Plus resulted in the highest shear bond strengths. The field-emission SEM observations showed accumulation of the fluid adhesive resin underneath the amalgam restoration, and an interpenetration between the amalgam and the adhesive resin, except for OptiBond and OptiBond FL. All systems, but Fuji Duet, formed an acid-resistant resin-dentin interdiffusion zone.

Analysis of Variance↗

Evaluation of depth of cure and Knoop hardness in a dental composite photo-activated using different methods.

The aim of this study was to evaluate the depth of cure and Knoop hardness in the P60 composite resin photo-activated using different methods. A bipartite brass matrix (3 mm in diameter X 11 mm in height) was filled with the composite and photo-activation was performed using continuous light, exponential light, intermittent light, plasma arc curing (PAC) or light-emitting diodes (LED). After opening the matrix, the uncured material was removed with a steel spatula and the polymerized composite was measured using a pachymeter. The specimens were then included in self-curing acrylic resin and worn longitudinally and the hardness was measured on the surface and at depths of 1, 2, 3, 4 and 5 mm. The data were analyzed by ANOVA and Tukey's test (5%). The results showed that the depth of cure was higher with the intermittent light, followed by continuous light, exponential light, PAC and LED methods. Up to a depth of 2 mm, all methods revealed similar hardness values, but there were differences between them at other depths, at which LED demonstrated the lowest values followed by PAC.

Carbon Compounds, Inorganic↗

Nail cosmetics: allergies and irritations.

Recent precise figures are not available for the number of adverse reactions related to the use of nail care products. Reactions to nail cosmetic procedures may be divided into reactions at the site of application to the nail itself and ectopic reactions, when the hand transfers a small amount of nail cosmetic to other areas of the skin. Fingernail coatings encompass two types: coatings that harden upon evaporation (nail enamel, base coat, top coat); and coatings that polymerize (sculptured nails, light-curing gels, preformed artificial nails, nail mending and nail wrapping). The test battery enables us to distinguish allergic reactions from irritant reactions. Interestingly, some reactions, such as distant allergic contact dermatitis, are more frequent with nail enamel than with coatings that polymerize. On the other hand, the latter are greater offenders in the nail area. Nail hardeners may just be modified nail enamels containing nylon fibers, acrylate resin and hydrolyzed proteins. Others may contain up to 5% formaldehyde tissue fixative (which can have adverse effects on the nail), but are designed in the US to be applied only to the free edge of the nail while the skin is shielded. Caution is necessary in interpreting formaldehyde patch testing reactions.

Acrylates↗