Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98Linked to original sources

Clinical evaluation of 3 types of plate osteosynthesis for fixation of condylar neck fractures.

PURPOSE: The goal of this study was to evaluate outcomes in patients who had condylar neck fractures treated with 3 different plating techniques. PATIENTS AND METHODS: A retrospective study was performed on 37 patients with 40 fractures of the condylar neck that were reduced and stabilized using an approach involving exposure of the facial nerve. Stabilization was achieved with a single miniplate (17 fractures), a minidynamic compression plate (13 fractures), or double miniplates (10 fractures). RESULTS: Plate fracture or screw loosening was exclusively observed in cases stabilized with either a single miniplate or a minidynamic compression plate. No cases of inadequate stability were observed when 2 miniplates were used. CONCLUSIONS: The 2-miniplate fixation technique provides functionally stable fixation for fractures of the condylar neck.

Adolescent↗

Intertrochanteric valgus osteotomy and sliding compression hip screw in fractures of the femoral neck.

Twenty-four patients ranging from 28 to 56 years of age with Garden grade III or IV fractures of the femoral neck are reviewed after treatment by intertrocherantic valgus osteotomy and Richards sliding compression hip screw. The rationale behind this treatment, the operative technique, and the choice of internal fixation device are all discussed. All patients were followed up after more than 2 years so that any late complications could be documented. The results were evaluated using both the Merle d'Aubigné procedure and radiographic examination: 12 (50%) were rated excellent, 5 (20.8%) good, 2 (8.4%) fair, and 5 (20.8%) poor. The unsatisfactory results are analyzed in detail, attributable to non-union in 2 cases (due to technical error), avascular necrosis in 4 cases (2 were limited and well-tolerated by the patients; 2 were early and massive and necessitated prosthetic replacement), and infection in one case. Even though valgus osteotomy and internal fixation fill a gap in the treatment of femoral neck fractures in adults by yielding good results with a conservative method, they are very demanding surgical procedures, requiring anatomical reduction, atraumatic technique, precise calculation of the valgus angle, and precise placement of the internal fixation device.

Adult↗

Surface strain distribution on thoracic and lumbar vertebrae under axial compression. The role in burst fractures.

STUDY DESIGN: The surface strain distribution on the thoracic and lumbar vertebrae during axial compressive loading was examined. OBJECTIVES: To examine the general mechanical behavior of the thoracic and lumbar vertebrae to evaluate their role in burst fractures. SUMMARY OF BACKGROUND DATA: Burst fractures are generally characterized by injury to the middle column and fracturing of the superior endplate. However, results in previous biomechanical investigations have not shown how these fractures are initiated during compression. METHODS: Twenty-one thoracic and lumbar vertebrae (5 T10, 10 L1, and 6 L4) with upper and lower vertebrae were studied. Three-axis rosette strain gauges were cemented to 11 sites on the vertebral surface. An axial compressive load was applied, and the strain was measured in each specimen. The strain recorded by each rosette gauge was converted into a tensile, compressive, and shear component. RESULTS: The highest tensile and compressive strain was recorded at the base of the pedicle. Shear strain in the vertebral body was significantly higher than that in the lamina at all three spinal levels. At L1 and L4, the tensile strain at the superior vertebral rim was higher than that at the inferior rim. CONCLUSIONS: The high tensile and compressive strains found at the base of the pedicle of T10, L1, and L4 indicate that the base of the pedicle is the site of fracture initiation. The higher tensile strain at the superior vertebral rim of L1 and L4 supports the clinical observation of the thoracolumbar burst fractures.

Aged↗

Treatment of fractures about hip prostheses with compression plating.

Between 1984 and 1986, 10 patients who sustained a femur fracture about a hip prosthesis were treated with open reduction and internal fixation using compression plating. Nine of the 10 fractures healed in an average time of 5 months. Other than one nonunion, no significant complications were noted. Follow-up study, ranging from 13 to 44 months (average, 26 months), was obtained on all 10 patients. One had a loose femoral component, which was attributed to inadequate stem size. None of the other patients had either clinical or radiographic evidence of loosening. Based on Harris hip scores, there was no indication that plating significantly interfered with hip function. The authors believe that these results demonstrate that plating can be an effective method of treating femoral fractures about hip prostheses.

Adult↗

8. Self-compressing implants in the management of fractures.

Internal fixation of fractures has become increasingly important since the introduction of self-compressing implants. Rigidity of fixation thus ensured permits primary bone healing. Two types of self-compressing implants are available--screws and plates. The former produces compression between fracture fragments, the latter, along the long axis of the bone. Two common types of plates are the dynamic compression plate and the Osteo self-compressing plate. Use of self-compressing implants requires familiarity with the technique, a definite plan of operation, and strict asepsis and lack of infection in the patient. Indications for the technique include failure or unsuitability of closed reduction of fractures, care of associated serious soft-tissue injuries, and displaced intra-articular fractures. Use of self-compressing plates hastens rehabilitation, lessens joint stiffness and reduces the duration of hospitalization. The incidence of nonunion with self-compression techniques is lower than with traditional methods of fracture management.

Bone Plates↗

[Compression hip screw fixation with bone cement in trochanteric fractures].

Internal fixation with compression hip screw (DHS) of trochanteric fractures in osteoporotic patients may be followed by failure of fixation. The most common failure is represented by the "cut-out" of the screw. This complication may occur in 4-10% of unstable trochanteric fractures. In order to avoid such a problem we chose a technical solution that offers a good fixation of the screw in the femoral head. The technique, described by Bartucci, was used in a 78 years old female with unstable trochanteric fracture and severe osteoporosis. The postoperative result was very good and no mechanical complications were noted. We consider that the technique of augmentation of fixation using acrylic bone cement may be a solution in such cases.

Aged↗

Midline sagittal sacral fractures in anterior-posterior compression pelvic ring injuries.

OBJECTIVE: To evaluate the outcome of an uncommon variant of the anterior-posterior compression pelvic injury, in which the posterior ring injury is a midline sagittal sacral fracture extending into the spinal canal. DESIGN: Prospective, consecutive series. SETTING Two regional trauma centers. PATIENTS: A consecutive series of 10 patients with rotationally displaced, vertically stable anterior-posterior compression pelvic ring fractures (OTA type 61-B1) in which the posterior ring injury is a midline sagittally oriented sacral fracture involving the spinal canal (Denis zone III). This injury pattern comprised 0.6% of pelvic fractures and 1.4% of sacral fractures treated at these two institutions during a 10-year period. INTERVENTION: Patients were treated according to the same principles used in more commonly seen types of anterior-posterior compression pelvic ring injuries. Nine patients were treated with reduction and anterior pelvic stabilization at an average of 5 days after injury, 8 of whom were treated with open reduction and internal fixation and 1 with external fixation. No posterior pelvic fixation was used. One patient with nondisplaced bilateral pubic ramus fractures was treated nonoperatively. Immediate weight bearing was allowed as tolerated. MAIN OUTCOME MEASUREMENTS: Prospectively collected clinical follow-up data emphasized a detailed neurologic examination, whereas radiographic evaluation involved anteroposterior, inlet, and outlet plain radiographic views of the pelvis. RESULTS: An anatomical or near-anatomical reduction of the pelvis was achieved and maintained in all patients. Fractures healed at an average of 10 weeks. At an average follow-up of 31 months (range 20-46 months), there were no objective neurologic deficits that could be attributed to sacral root injury and no significant residual pain or gait disturbance related to the pelvic fracture. Loss of bowel or bladder function, loss of perianal sensation or sphincter tone, and lumbosacral radicular pain or sensorimotor deficit were specifically absent in all patients. Three patients, however, complained of sexual dysfunction at final follow-up. None of these patients had clinical evidence of sacral root/plexus injury secondary to the fracture. One additional patient, who sustained a urethral tear, required a chronic suprapubic catheter because of stricture. Six patients, one of whom had needed repair of a retroperitoneal bladder tear, had no urogenital sequelae. DISCUSSION AND CONCLUSION: Patients who sustain sagittally oriented midline fractures of the sacrum that extend into the spinal canal (Denis zone III) as part of displaced, vertically stable anterior-posterior compression pelvic injuries, have a low incidence of neurologic deficit attributable to sacral root or plexus injury. This is in contrast to the high rate of neurologic deficit (>50%) otherwise reported in zone III sacral fractures, particularly in those associated with a displaced transverse component. In the midline sagittal fracture variant, simultaneous lateral displacement of both bony and neural elements through the midline may protect the sacral roots and plexi from significant traction or shear injury by maintaining the spatial orientation between the sacral foramina and sciatic notch. Long-term sequelae were related to urogenital complaints rather than to musculoskeletal problems, as 4 of the 10 patients in this series had either sexual or urologic dysfunction.

Adult↗

Compression plating of tibial fractures following primary external fixation.

During the time period from May 1990 to December 1992, a total of 75 tibia fractures were treated in the Department of Traumatology at the University of Bonn. Thirty-eight patients with 40 tibial fractures were managed according to a regimen including primary stabilization, usually using external fixation, soft tissue reconstruction and delayed open reduction and internal fixation using an AO compression plate. The majority of the patients had been involved in motor vehicle accidents, leading to multiple injuries in 24 instances. An open fracture was seen 18 times. The 20% complication rate is comparable to the reports following intramedullary stabilization. Only one infection, following a grade 2 open fracture, was seen after the definitive stabilization. Bony union was achieved after 15.7 weeks. In light of the complications associated with intramedullary nailing, such as fat or air embolism, heterotopic ossification and non- or malunions, use of the tibial plate does not offer just logistic advantages, but is a viable alternative for delayed stabilization of tibial fractures. No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. No funds were received in support of this study.

Adult↗

Sliding characteristics of compression hip screws in the intertrochanteric fracture: a clinical study.

Sliding of compression hip screws (CHS) is advantageous when it allows for controlled collapse of a hip fracture and progressive stabilization. A retrospective review was performed on 47 intertrochanteric (IT) fractures treated with a Zimmer CHS. Previous studies had identified certain parameters as being important to CHS sliding characteristics in vitro. Using conventional diagnostic material (radiographs), we sought to use these parameters as clinically useful tools. Screw sliding, as well as geometric parameters of CHS that relate to screw sliding, such as barrel engagement in relation to screw extension and screw-plate angle, were measured and calculated from serial radiographs. Almost all screw sliding occurred within 30 days postoperation. Fracture stability and quality of reduction were two main factors relating to screw sliding (p < 0.01). High screw-plate angle and longer screw-barrel engagement had no correlation with screw sliding even in unstable fractures. All five failures were due to cut-out after complete or almost complete collapse of the sliding mechanism in non-anatomically reduced fractures in osteoporotic females. Unstable fractures in osteoporotic bone do seem to require supplementary fixation beyond sliding screw fixation alone. None of the mechanical parameters (as judged from plane radiographs) that control the tendency of the CHS to slide could be statistically correlated with incidence or degree of sliding. Therefore, it was concluded that it is impractical to attempt to predict sliding tendency from plane radiograph measurements.

Adult↗

A fracture study of the diametral compression test by means of high-speed photography.

High-speed photography (2000-6000 pictures/sec) was used to register the fracture propagation process in gypsum specimens (diameter 40 mm, length 14 mm) loaded via 2 mm wide, strip-shaped paddings and under direct contact with plane press platens. With paddings in 3 out of 4 experiments the fracture, as it appeared on the first film frame, was asymmetrically located on the loaded diameter. In two direct-contact experiments the initial fracture had its widest part centrally and lateral fractures, of the "triple-cleft" type, appeared subsequent to the cental fracture. Smaller specimens (diameter 7, length 14 mm), manufactured in an investment compound (Ceramigold) were tested by the use of plane and vaulted platens, giving the same width of the loaded area. With vaulted platens the fracture first appeared in a peripherical zone in 3 out of 5 experiments and with plane platens in 6 out of 11 experiments. In two thirds of all cases, where the primary fracture sign appeared peripherically, it appeared in an area immediately centrally of the compression zones. These fractures were probably peripherically initiated and thus non-valid. Specimen appearance after testing gave, however, no clear indication of a non-valid fracture.

Calcium Sulfate↗

Management of fractures and fracture complications of femoral shaft using the ASIF compression plate.

Nnieteen acute fractures and fourteen fracture complications of the femoral shaft were managed with ASIF plate fixation. Two patients having femoral shortening procedures were similarly managed. Most injuries involved the distal femoral shaft, and were judged unacceptable for intramedullary nailing. Single plate fixation and immediate mobilization of the knee joint were possible in most patients. Technical failure, refracture through an end-screw hole, or nonunion occurred in 20% of the injuries. Plate fixation of the femoral shaft is not the surgical procedure of choice for management of femoral shaft injuries. It is an acceptable alternative to intramedullary nailing but carries a higher risk of complication.

Adolescent↗

Screw position affects dynamic compression plate strain in an in vitro fracture model.

OBJECTIVE: This investigation considers the effect of a variety of screw positions on plate strain in three fracture models. DESIGN: Dynamic compression plate fixation of in vitro fracture models. METHODS: To model a fracture, a plastic pipe was cut transversely and a twenty-hole dynamic compression plate was attached by screws. Eighteen stacked, rectangular, rosette strain gauges were installed on the plate to evaluate strain. Three models were evaluated: two constructs in which there was no contact between the cut ends of the pipe under the fixation plate (small-and large-gap models) and a construct in which there was direct apposition of the cut ends (no-gap model). The pattern and magnitude of strains were assessed as a function of varying combinations of screw position for each model. RESULTS: Maximal plate strain in the gap models was lowest with screws placed closest to the gap, compared with screws placed away from the gap or spaced apart. The no-gap model showed significantly lower strains when screws were placed further from the osteotomy site than when screws were positioned close together or spaced apart. In all cases, maximal plate strain occurred adjacent to the most central screw holes and rapidly dissipated along the length of the plate. CONCLUSION: In a model simulating a comminuted fracture (gap), this study found that screws should be placed as close to the fracture site as possible to minimize plate strain. In an anatomically reduced two-part fracture model (no gap), widely spaced screws or those placed away from the fracture resulted in lower strains.

Bone Screws↗

Bone mass, bone structure and vertebral fractures in osteoporotic patients.

The clinical severity of bone disease was studied in 44 post-menopausal osteoporotic women. Spinal x-rays were assessed and compared to objective measurements of bone mass and bone structure; forearm bone mineral content (BMCarm) by single photon absorptiometry, total body bone mineral content (TBBM), and spinal bone mineral content (BMCspine) by dual photon absorptiometry, and corrected cortical width (C Cor W), trabecular bone volume (TBV), and indices of trabecular microstructure by iliac crest biopsy. For comparison data of BMCarm, TBBM and BMCspine in 25 post-menopausal normals are shown. The results showed a reduction in amount of both cortical and trabecular bone in the fracture patients compared to normals. A subdivision of the fracture patients into two groups constituting 26 patients with wedge fractures alone and 18 patients with compression (+wedge) fractures showed that the latter group had a further predominantly trabecular bone loss and a further deteriorated trabecular microstructure. On an individual basis no agreement between clinical severity of bone disease and amount and structure of bone could be demonstrated.

Aged↗