The rise and fall of i-STAT point-of-care blood gas testing in an acute care hospital.

In response to a $350,000 laboratory budget cut and closure of an intensive care unit-based laboratory and a desire to maintain turnaround times of 10 minutes or less, a multidisciplinary group developed and implemented point-of-care (POC) testing. Only blood gases (pH, PO2, and PCO2) and ionized calcium values were deemed essential stat tests. Three commercially available POC blood gas devices were evaluated; all yielded results comparable to in-house reference methods. The 1 device with a US Food and Drug Administration-approved method for ionized calcium testing and with an existing interface for laboratory information systems was selected. Fiscal analysis predicted annual savings of approximately $225,000. POC blood gas analysis was implemented in April 1996 coincident with closure of the intensive care unit-based laboratory. Clinical laboratories and POC blood gas test volumes remained constant through August 1998; in contrast, the number of ionized calcium tests decreased dramatically after April 1996. In August 1998, clinically significant (i.e., artificial ventilation parameters would have been altered based on test results) discrepant PCO2 values were observed sporadically and noted only with patient specimens, not with commercial controls or electronic simulators. Because investigation failed to identify the cause, use of the POC device was discontinued in September 1998.

Blood Gas Analysis↗

Patient selection for incus body coupling of a totally implantable middle ear implant.

OBJECTIVE: To evaluate audiologic selection criteria for incus body coupling (IBC) of a totally implantable middle ear implant (TI-MEI) for the treatment of sensorineural hearing loss (SNHL). MATERIAL AND METHODS: The protocol is specified in the Investigational Device Exemption of a Food and Drug Administration-approved multicenter clinical trial. The prospective study compared pre- and postoperative hearing levels using each patient as their own control. In addition, an implant on/off comparison was made. All patients had a follow-up interval of at least 6 months. Audiologic assessment tests included speech discrimination in quiet as the primary efficacy variable and pure-tone audiometry (aided thresholds), gain, speech recognition in noise and subject satisfaction using standardized questionnaires and visual analog scales (VASs) as secondary efficacy variables. The study group of patients (n = 13) was divided into 3 subgroups based on their pure-tone and speech discrimination scores: Group A consisted of 6 patients, Group B 9 patients and Group C of all 13 patients. All patients suffered from long-standing bilateral moderate to severe SNHL. Five patients were dissatisfied hearing aid (HA) users and eight subjects could not wear HAs. All patients were implanted with a TI-MEI which was coupled to the incus body. The amplification level of the device was set postoperatively using inductive digital fitting based on "most comfortable loudness" specifications. RESULTS: The implant produced median improvements from 30% (optimally fit bilateral HAs; n = 5) and 50% (HA non-users; n = 8) to 70% word recognition at 60 dB SPL. Average word recognition scores at 60, 80 and 90 dB SPL in Groups A and B showed increases from 42% (interquartile range +27%, -12%) to 93.5% (+3%, -5%) and 92.5% (+3%, -7%), respectively. In the presence of background noise, the sentence recognition threshold ranged from -2 to 1 dB signal-to-noise ratio. Maximum amplification was 50 dB at 3 kHz and 55 dB at 4 kHz. In Groups A and B, VASs revealed improvements in both natural sound impression and clarity from 62-70% of a natural sound impression to maximum scores of 100%. Using the standardized Gothenburg profile, subjective evaluations of hearing, orientation, social behavior and self-confidence reached 96-98%, 92-96% and 84-92% of the maximum score for Groups A-C, respectively. CONCLUSIONS: In selected cases, IBC of the TI-MEI investigated herein may be indicated for the treatment of SNHL, provided the following four conditions are met. First, the patient does not derive sufficient benefit from conventional HAs. Second, the specific indication for IBC is restricted to situations that do not allow the coupling of the MEI to the long incus process (e.g. due to an anatomical variation of facial nerve location). Third, IBC is restricted to patients with a steeply sloped moderate to severe high frequency SNHL, amounting to 90 dB HL from 3 to 8 kHz. Patients with low frequency SNHL should not be operated on with the IBC technique, as maximum low frequency hearing loss at 0.5 kHz must not exceed 30 dB. Fourth, Schueller's X-ray should reveal normal mastoid pneumatization. Being restricted to a 6-month follow-up period, this paper provides early clinical results and no clinical evidence of long-term efficiency of the implant.

Adult↗

Optional vena cava filters for patients with high thromboembolic risk: questions to be answered.

The use of vena cava filters has increased rapidly over the past few years to more than 140,000 filters inserted worldwide in 2003. Continued improvements in filter design have increased the safety of intravascular caval filtration. Although there are many factors attributed to this increase, the most significant contributing factor has been the development of optional vena cava filters. That is, filters that can be left as a permanent device or can be removed endovascularly at a later date. Three filters are approved for removal in the United States, the Günther Tulip, the OptEase, and the Recovery. Recent reports have demonstrated the safety and feasibility of these devices in appropriate patients, but a number of questions have arisen regarding their use.

Device Removal↗

The classification of antiseptic products to be administered to wounds--another borderline case between medicinal products and medical devices?

The importance of a correct demarcation between a Medicinal Product (MP) and a Medical Device (MD) is undisputedly one of the major topics related to the development and launch of a new healthcare product. However, for some products the correct demarcation between MPs and MDs can turn out to be somewhat complicated. This article aims to provide an overview on the existing legislation and its adequate application based on a suitable example at hand. Article 2 (2) of the European Directive 2001/83/EC as amended by Directive 2004/27/EC on the Community code relating to medicinal products for human use stipulates that the respective Medicinal Products Legislation must be applied whenever a product can be covered by both the definitions for MPs and for products regulated by other legal provisions enacted by the European Community, e.g. Cosmetic Products (CPs) or MDs. This basic principle implies that the decision to base the risk-benefit assessment of the product in question on the Medical Device Directive (MDD) would contradict the aforementioned constitutional principle, pursuant to which the stricter of the regulatory procedures theoretically possible is to apply in cases of doubt. In contrast to the approval procedure established for MPs, the MDD requires a Conformity Assessment Procedure to be performed by the manufacturer himself and a "Notified Body". Thus, in the majority of cases the responsibility for the risk assessment of MDs lies solely with the manufacturer and is prior to launch not subject to further scrutiny by regulators. Only in specific cases, i.e. for the Conformity Assessment Procedure of Class III MDs which contain an Active Pharmaceutical Ingredient one of the Member States competent authorities designated in accordance with Directive 65/ 65/EEC has to be involved before taking a decision. It is therefore important that the classification of the product is carried out carefully in full compliance with existing legal provisions, also taking into account the related guidance documents issued by the European Commission. The adequate application of these rules is explained using the example of the antiseptic compound polihexanide, which is used both in approved medicinal products (wound antiseptics) and wound irrigation solutions labelled as medical devices.

Animals↗

In vivo evaluations of a new thromboresistant polyurethane for artificial heart blood pumps.

To reduce the risk of thromboembolic complications in prosthetic blood pumps, we have developed a new segmented polyurethane elastomer. This material is unique because its mechanical properties for long-term durability and surface properties for biocompatibility have been separated and developed in two distinct materials. Improved thromboresistance is then obtained by a 1% concentration of a new polymeric surface-modifying additive blended with the base polyurethane before fabrication of the blood pump. To evaluate this material in vivo, we performed 10 implants, in calves, of the Pierce-Donachy prosthetic ventricle with blood-pumping sacs and cannulas fabricated from the new surface-modifying additive copolymer blend (Thoratec's BPS-215M). In four control implants the blood sacs and cannulas were fabricated from Ethicon's Biomer segmented polyurethane, which is the present clinical standard for most artificial hearts and circulatory support devices. The blood pumps were connected from the apex of the left ventricle to the descending aorta in male Holstein calves weighing 82 to 108 kg and were driven pneumatically in the full-to-empty mode with flows averaging 5 to 6 L/min. Each calf was medicated with aspirin and dipyridamole throughout the study period and was electively put to death after 4 weeks for evaluation of explanted blood sacs and for examination of the kidneys for infarction. All 10 explanted blood sacs made with the surface-modifying additive copolymer blend were shiny and completely free of thrombus. Three of the four explanted Biomer blood sacs showed visible red thrombus, and all four showed small areas of white thrombus. The average surface area of the Biomer blood sacs covered with thrombus was 45 +/- 32 mm2. Use of a semiquantitative scale to assess renal infarction demonstrated that nine of 10 animals with a surface-modifying additive copolymer blend blood sac had infarction less severe than the mean infarct score of the animals with a Biomer sac. The surface-modifying additive copolymer blend has excellent mechanical and physical properties necessary for use in artificial heart blood pumps. From these experiments, we conclude that the surface-modified polyurethane blend is superior to Biomer polyurethane in blood compatibility and in freedom from thromboembolic risk. This material is now approved by the Food and Drug Administration for investigational device exemption studies in the Pierce-Donachy prosthetic ventricle.

Animals↗

Hospital costs for left ventricular assist devices for destination therapy: lower costs for implantation in the post-REMATCH era.

BACKGROUND: The use of left ventricular assist devices (LVADs) as an alternative to transplant, or destination therapy (end of life support), is an increasingly important option for patients with end-stage heart failure. Prior studies have examined hospital costs for LVAD implants performed during investigational studies (e.g., REMATCH), but none has been published since that trial was completed. METHODS: We performed a retrospective analysis of 23 consecutive patients who had a HeartMate XVE pump implanted as destination therapy at 2 high-volume ventricular assist device implant centers after US Food and Drug Administration approval in October 2003. We evaluated survival to discharge during the implantation hospitalization, hospital length of stay, and hospital costs, and compared them with outcomes reported from the REMATCH (RM) trial. RESULTS: All patients in this cohort implanted post-REMATCH (PRM) had class IV heart failure and were similar in age, gender, and nearly all other pre-implantation clinical measures to the RM subjects. Mean hospital costs for PRM patients were 40% lower than for RM patients when measured from implantation to discharge (dollar 128,084 vs dollar 210,187, p < 0.01). PRM patients who survived implantation hospitalization had 48% lower costs than those who did not survive (dollar 114,979 vs dollar 215,456, p < 0.01), a finding similar to the RM experience. PRM patients in this cohort were more likely to survive to discharge compared with RM patients (87.0% vs 67.3%, p = 0.09). Mean hospital length of stay was 25% lower in the PRM group (44 vs 33 days) but did not reach statistical significance (p = 0.50). CONCLUSIONS: Outcomes with use of LVADs as destination therapy have improved in the post-REMATCH era, including significantly lower hospital costs as well as strong trends toward better survival to hospital discharge and shorter average length of stay.

Aged↗

T-Screw. A new bone fixation device.

The T-Screw was patented in 1984. A 5-year study was begun in 1980, and FDA approval was granted in 1985. Detailed results of this clinical study will be reported in a later paper. The purpose of this paper is to introduce the device. The authors have found that early return to normal function and wearing shoes has been possible when using T-Screws for fixation of podiatric osteotomies. The screw appears to accelerate bone healing and has numerous applications throughout the foot. The authors believe that its ease of application and removal as well as its ability to generate rigid, compressive fixation makes it an excellent alternative to current fixation devices.

Bone Screws↗

Education of the ventricular assist device patient's community services.

Two implantable, electric left ventricular assist systems have received approval from the Food and Drug Administration (FDA) for use outside a hospital environment. As patients supported with these systems are discharged from the hospital, it is important that various community services and agencies be involved in the care of this unique patient population. Between January 1999 and May 2001, The University of Iowa Hospitals and Clinics (UIHC) implanted 14 HeartMate VE LVAS (Thoratec Corporation, Pleasanton, CA) in patients as a bridge to cardiac transplantation. Of these 14 patients, 13 were discharged home from the hospital. On the basis of our 3 year experience, a discharge program has been developed to educate the ventricular assist device (VAD) patient's community services. Ten community services most critical to a safe home discharge program are identified. Timing of service contact, mechanism of contact, community education method, education content, education materials, and outpatient community service usage are described.

Ambulatory Care↗

In vitro and in vivo evaluation of a reusable double-channel sphincterotome.

BACKGROUND: To date, one reusable, double-channel sphincterotome has been approved by the Food and Drug Administration in the United States. Whether this device can be reprocessed easily and whether it is more durable than currently manufactured disposable sphincterotomes are uncertain. METHODS: Thirty double-channel, 20 mm, braided-wire sphincterotomes approved for multiple uses were studied in vitro/in vivo with regard to durability and sterilization. A cost analysis of reusable, disposable, and reprocessed disposable sphincterotomes was also carried out. RESULTS: Three of 10 sphincterotomes evaluated in vitro broke after 3, 4, and 8 uses. Electrical integrity was preserved after 10 uses in the remaining sphincterotomes. Nine sphincterotomes remained functional for at least 3 uses, five for 6 uses, and one for 10 uses. Culture results after inoculation demonstrated contamination with surviving organisms after manual cleaning and no growth after ethylene oxide sterilization. Sixty-one procedures were performed in vivo using 20 sphincterotomes (mean number of uses 3.1). No evidence of procedurally related infection occurred with reuse. Cost per use of this reusable sphincterotome was calculated to be $62.98; it became cost effective after 2.2 and 7.9 uses when compared with disposable and reprocessed, disposable sphincterotomes, respectively. CONCLUSIONS: This reusable sphincterotome proved to be safe, easily sterilized, and electrically intact after repeated use. In vivo, however, a progressive loss of function limited the mean number of uses to 3.1. In settings that preclude reuse of reprocessed disposable accessories, this reusable sphincterotome may provide a means to decrease costs associated with endoscopic retrograde cholangiopancreatography.

Cholangiopancreatography, Endoscopic Retrograde↗

Effects of sputum oscillations and rhDNase in vitro: a combined approach to treat cystic fibrosis lung disease.

Mucolytic treatment with rhDNase is part of the current therapy for cystic fibrosis (CF) lung disease. The Flutter valve, a device for enhancing airway mucus clearance, has recently been approved for use in CF patients. Exhalation through the Flutter valve leads to oscillations of expiratory airflow, improving mucus viscoelasticity and stimulating clearance. The goal of our in vitro study was to evaluate the individual and combined effects of Flutter valve oscillations and rhDNase treatment on the viscoelastic (rheological) properties of CF sputum. Sputum specimens were collected from 19 CF patients and subjected to the following protocols: 1) baseline sample with no treatment applied; 2) application of oscillations generated by airflow through the Flutter valve; 3) incubation at 37 degrees C for 30 min with 10% vol/wt rhDNase (Pulmozyme) to achieve a final concentration of 2.5 microg/mL (approximately 100 nM); 4) combination of Flutter valve oscillations and 10% vol/wt normal saline (0.9% NaCl); 5) combination of Flutter valve oscillations and 10% vol/wt rhDNase at 2.5 microg/mL final concentration. For each protocol, the mucus rigidity index (log G* at 1 rad/s) was measured at baseline and at 30 min. Values are presented as mean+/-SEM. The cough clearability index (CCI) was computed from measurements of mucus viscoelasticity, based on relationships established in model studies. Flutter valve treatment alone did not result in a significant reduction in the rigidity of CF sputum (2.24+/-0.13 vs. 2.11+/-0.13, P=0.19), nor did rhDNase (2.5 microg/mL) alone, although we have previously shown (Pediatr. Pulmonol. 1995; 20:78) that both of these treatments reduce sputum spinnability, which is more sensitive to molecular weight reduction. In comparison to individual treatments, combined treatment with Flutter valve oscillations and rhDNase significantly reduced the mucus rigidity to 1.85+/-0.19 from 2.24+/-0.13 (P< 0.001), consequently increasing the predicted clearability of the sputum (from 1.09+/-0.26 to 1.83+/-0.48, P=0.012). These in vitro results suggest that a combination of biochemical treatment (e.g., DNase) and mechanical oscillation may have a better therapeutic potential for mucus clearance in CF lung disease.

Adult↗

Use of a novel ultrafiltration device as a treatment strategy for diuretic resistant, refractory heart failure: initial clinical experience in a single center.

BACKGROUND: The System 100 UF device allows ultrafiltration (UF) via peripheral access and is approved for use in heart failure (HF), although clinical trials defining optimal target population and clinical utility are lacking. We report our initial experience with clinical use of this system in very advanced, diuretic resistant HF patients. METHODS AND RESULTS: Eleven HF patients (mean age 70 years) underwent 1 to 5 UF treatments each (total 32 UF). The goal was to remove 4 liters of fluid per 8-hour UF. Baseline creatinine averaged 2.2 mg/dL (range .9-3.2) while estimated glomerular filtration rates (GFRs) averaged 38 mL/min (range 20-87). Nine patients (82%) had moderate (GFR 30-59; n = 3) or severe (GFR <30; n = 6) renal dysfunction. Nine patients (82%) had documented right ventricular dysfunction, 6 with severe tricuspid regurgitation. Average daily intravenous furosemide dose prior to UF was 258 mg (range 80-480). Patients had received nesiritide (n = 4), dopamine (n = 4), and zaroxylyn (n = 7) prior to UF. Of the 32 UF treatments, 13 (41%) removed >3500 mL, 11 (34%) removed 2500-3500 mL, and 8 (25%) removed <2500 mL. Only one UF treatment (3%) was aborted due to hypotension. There were no significant complications related to UF. Five patients (45%) experienced an increase in creatinine of >.3 mg/dl. Five patients required dialysis for persistent diuretic resistant volume overload or uremic symptoms. Six-month mortality was 55%. CONCLUSIONS: Peripheral UF safely but variably removed fluid. In this very high-risk, advanced HF population, 45% of patients developed worsening renal function during UF therapy. Controlled studies are needed to determine the impact of UF on renal function and outcomes in high-risk populations such as this.

Aged↗

Comparison of respirable coal mine dust concentrations measured with an MRE and a newly-developed, two-stage impactor sampler.

The design and laboratory evaluation of a two-stage aerosol sampler using an impaction plate for removing particles above 10 micron, has been reported. The unit was developed to provide an alternative to the two-stage sampling head used on approved coal mine personal respirable dust samplers. The new device offers the potential of increasing the analytical accuracy of samples, and of providing a device more suitable to the mining community for use in their mandated dust sampling program. This paper describes the underground sampling program conducted to establish the factor for converting respirable dust concentrations measured with this device to equivalent concentrations measured with an Isleworth 113A gravimetric dust sampler (MRE). This study demonstrated that the use of the impactor sampling head provides a viable alternative to the currently used sampling head. The results showed that comparative measurements could be linearly related for MRE dust measurements ranging from 0.5 to 5.5 mg/m3. The factor determined for converting measurements made with the new head to equivalent MRE measurements was approximately 0.5.

Coal↗

A new non-pharmacological vacuum therapy for female sexual dysfunction.

Although Female Sexual Dysfunction (FSD) affects 40% of American women, there is no FDA-approved pharmaceutical therapy. The EROS-CTD (Clitoral Therapy Device, UroMetrics, Inc., St. Paul, MN) treatment is the first FDA cleared-to-market therapy for FSD. Clitoral engorgement is believed to play an important role in female sexual arousal and overall sexual satisfaction. The EROS-CTD is a small, battery-powered device designed to enhance clitoral engorgement, increase blood flow to the clitoris, and ultimately improve arousal in women with FSD. The objective of this study was to assess the effectiveness of the EROS-CTD on sexual arousal (genital sensation, vaginal lubrication, ability to reach orgasm, and sexual satisfaction) in normal volunteers and women with FSD.

Adult↗

Treatment of cytomegalovirus retinitis with the intraocular ganciclovir implant.

The treatment of cytomegalovirus retinitis (CMV-R) has improved considerably in the past two years. Local ocular therapy has proved to be effective and provides significant advantages over systemic therapy with regards to better control, preventing progression, avoiding bone marrow and renal toxicity. Direct intraocular injections of anti-CMV drugs and the sustained-release ganciclovir device are the mainstay of local therapy. The ganciclovir intraocular device has undergone rigorous testing and has recently been approved for clinical use. This review describes the surgical procedure, recommendations for use, and exchange and management of associated retinal detachment. In addition, the results of the initial studies and the multicenter, randomized clinical trial are discussed. Current data available from the Study for the Ocular Complications of AIDS (SOCA) and AIDS Clinical Trials Group (ACTG) studies are summarized in the context of CMV-R management.

Antiviral Agents↗

Bronchoscopic brachytherapy.

Increasing lung cancer mortality has created renewed interest in the bronchoscopic use of isotopes for palliation of recurrent airway carcinomas. In the first part of this paper we report our clinical experience with iodine-125 implantation for treatment of endobronchial carcinomas in 18 patients followed until death. Symptoms of cough, hemoptysis, and dyspnea were most effectively relieved with tumors limited to the bronchial lumen. Contraindications to this procedure include extensive extrabronchial tumors causing airway compression and severe debility. In the second part of this paper the development of a new isotope delivery system designed to overcome technical difficulties experienced in the treatment of some patients with interstitial iodine 125 is described. An isotope capsule was constructed to permit insertion and removal by means of a fiberoptic bronchoscope. This device was successfully tested in animals and is now approved for clinical trials. It represents a unique, new modality for treatment of superficial, multifocal, and less-advanced recurrent bronchogenic carcinomas.

Aged↗

[Oversized patient arms: a problem with blood pressure measurements].

The increase in the worldwide prevalence of obesity systematically leads to a higher number of individuals who may be wrongly diagnosed as hypertensive because their arms are too large for standard blood pressure cuffs, which are ordinarily appropriate in patients with normal sized arms. The aim was to gain real data of upper arm and wrist circumferences in 327 elected subjects with larger arms (upper arm circumference >32.5 cm) from two Bavarian general practices. We found that 93.9% of all patients had an upper arm circumference of a maximum of 41.0 cm and a wrist circumference of at most 20.5 cm. These data were then compared with the approved size ranges of six wrist blood pressure measurement devices, one special three-in-one cuff for different sizes and the two large adult cuffs recommended by the German Hypertension Society. Availability of one large cuff and one wrist blood measurement device (either used at the upper arm or at the wrist depending on patient dimensions) seems to be sufficient. This should allow for true blood pressure readings to be obtained in at least 96% of all patients with arms of more than normal circumference.

Arm↗

Laser-enhanced angioplasty.

We have successfully used a balloon-guided laser to ablate arteriosclerotic plaque, thus permitting use of standard angioplasty to treat seven patients with severe peripheral artery obstruction. The device (Lastac System, marketed by G.V. Medical, Inc, and approved by FDA in December 1988) is designed to reduce the incidence of vessel perforation by using the balloon to center an argon laser between the vessel walls. A control monitor allows the physician to determine the amount and duration of energy applied. A lens on the laser tip further reduces risk of damage by narrowing the laser beam's angle of delivery, and an infusion pump cools tissue receiving laser energy and clears blood from the beam's field. Each of the seven patients treated with the Lastac System continues to be free of claudication; one patient experienced clinically insignificant vessel perforation. Although this series of patients is quite small, we believe increased use of the system will further demonstrate its effectiveness in eliminating plaque and probably will reduce the occurrence of restenosis.

Aged↗