Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “ACRYLIC RESINS”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,765 records · Page 98Linked to original sources

Effect of operators' skills on increase in cavity volume of restorations.

OBJECTIVE: The purpose of this in vitro study was to evaluate the change in cavity volume after removal of amalgam and resin composite restorations, based on the dental skills of the operators. METHOD AND MATERIALS: A high-speed turbine and diamond burs were used to prepare Class II cavities in 60 acrylic resin mandibular first molar teeth. After the teeth were weighed with precision scales, the cavities were restored with amalgam or posterior resin composite. The restored teeth were then stored in distilled water at room temperature for 48 hours. Three undergraduate students with 2 years' practical experience on patients, and three postgraduate students with an additional 4 years' practical experience in the Department of Operative Dentistry, removed the restorations from the cavities with a high-speed turbine, and the teeth were all weighed again. After cavities were rerestored with the same materials, each restoration was removed once more by the same operator. The weighing procedure was repeated before and after the removal of the restorations. The data were subjected to paired and unpaired t tests. RESULTS: Every time a restoration was removed from a tooth, the cavity preparation became significantly larger, but the postgraduate students caused significantly smaller increases in cavity volume. CONCLUSION: Increases in cavity volume are not based on the nature of t he restorative material; however, the individual experience levelsand dental skills of the operators lead to significant differences in the cavity volume increase.

Clinical Competence↗

The efficiency of different light sources to polymerize resin cement beneath porcelain laminate veneers.

Plasma arc light units for curing resin composites have been introduced with the claim of relatively short curing times. The purpose of this study was to evaluate the efficiency of two different light sources to polymerize dual curing resin cement beneath porcelain laminate veneers. Twenty extracted healthy human maxillary centrals were used. Teeth were sectioned 2 mm below the cemento-enamel junction and crown parts were embedded into self-cure acrylic resin, labial surface facing up. Cavity preparation was carried out on labial surfaces. These teeth were divided into two groups of 10 each. The resin cement/veneer combination was exposed to two different photo polymerization units. A conventional halogen light (Hilux 350, Express Dental Products) and a plasma arc light (Power PAC, ADT) were used to polymerize resin cement. Ten specimens were polymerized conventionally (40 s) and the other specimens by plasma arc curing (PAC) (6 s). Two samples from each tooth measuring 1.2 x 1.2 x 5 mm were prepared. These sections were subjected to microshear testing and failure values were recorded. Statistically significant differences were found between the bond strength of veneers exposed to conventional light and PAC unit (P < 0.001). Samples polymerized with halogen light showed better bond strength. The results of this study suggest that the curing efficiency of PAC through ceramic was lower compared with conventional polymerization for the exposure durations tested in this study.

Adhesiveness↗

Evaluation of the effect of EDTAC, CDTA, and EGTA on radicular dentin microhardness.

The effect of EDTAC (ethylenediamine tetra-acetic acid plus Cetavion, an ammonium surfactant), CDTA (cyclohexane-1,2-diaminetetra-acetic acid), and EGTA (ethylene glycol-bis-(beta-amino-ethyl ether) N,N,N',N'-tetra-acetic acid) on the microhardness of radicular dentin of the cervical third of human teeth was studied. Five newly extracted maxillary incisors were sectioned transversely at the cementoenamel junction, and the crowns were discarded. The roots were embedded in blocks of high-speed polymerized acrylic resin and cut transversely into 1-mm sections. The second slice of the cervical third of the root of each tooth was sectioned and divided into four parts. Each part was placed on an acrylic disc that was used as a base for microhardness measurement. Fifty microliters of 15% EDTAC, 1% CDTA, or 1% EGTA were applied to the dentin surface. Deionized and distilled water was used as control. Dentin microhardness was then measured with a Vicker's microhardness apparatus with a load of 50 g for 15 s. Statistical analysis showed that the three chelating solutions significantly reduced dentin microhardness when compared with water; however, there was no statistically significant difference among the three solutions.

Analysis of Variance↗

Effect of different EGTA concentrations on dentin microhardness.

The effect of 1%, 3% and 5% EGTA (ethylene glycol-bis-(beta-amino-ethyl ether) N,N,N',N'-tetra-acetic acid) on the microhardness of root dentin of the cervical third of human teeth was studied. Five newly extracted maxillary incisors were sectioned transversely at the cementoenamel junction, and the crowns were discarded. The roots were embedded in blocks of high-speed polymerized acrylic resin and cut transversely into 1-mm sections. The second section of the cervical third of the root of each tooth was sectioned and divided into four parts. Each part was placed on an acrylic disc that was used as a base for microhardness measurement. Fifty microliters of 1% EGTA, 3% EGTA, or 5% EGTA were applied to the dentin surface. Deionized and distilled water was used as control. Dentin microhardness was then measured with a load of 50 g for 15 s. Statistical analysis showed that the three concentrations of the chelating solution EGTA significantly reduced dentin microhardness when compared with water (ANOVA, p < 0.01), and that there was a statistically significant difference among the three solutions (Tukey test, p < 0.05).

Analysis of Variance↗

[Stress analysis of distal free-end removable partial denture].

The study of the force distribution in distal free-end removable partial denture is complicated by the great difference of biomechanical property between the supporting tissue of the distal free-end removable partial denture, abutment tooth and alveolar mucosa under the denture base. Finite element method (FEM) was used in this study to estimate the effect on the abutment tooth and alveolar mucosa under various load conditions. The model is composed of the second premolar, the first molar and the second molar in acrylic resin teeth with the first premolar serving as the abutment. The stress on the abutment tooth was found reduced by 15% on comparing the load condition 3 (222 newton vertical force on each denture acrylic tooth) with the load condition 2 (222 newton vertical force on the second premolar and the first molar), and it can be further reduced by 22% in comparison to load condition 4 (222 newton vertical force on each denture tooth but shared equally to two occlusal contact points per denture tooth). The maximum displacement of the alveolar mucosa was found adjacent to the load area, and the maximum vertical displacement of the alveolar mucosa at load condition 4 is only 0.015 mm greater than load condition 3. It is concluded that when the number of occlusal contacts in distal free-end removable partial denture is increased and evenly distributed, the load on the abutment tooth will be decreased, with only minor effect on the alveolar mucosa.

Biomechanical Phenomena↗

Repairability of three resin-modified glass-ionomer restorative materials.

The purpose of this study was to evaluate the repair shear bond strengths of three resin-modified glass-ionomer restorative materials repaired at two different times. Thirty specimens of Fuji II LC, Vitremer, and Photac-Fil were prepared in cavities (2 mm x 7 mm) cut into acrylic resin cylinders. After the initial fill, half of the specimens were repaired 5 minutes later and half 1 week later. The specimens were stored in 37 degrees C distilled water when not being repaired or tested. Repairs were made without any surface preparation of the initial fill. Each specimen was mixed according to the manufacturer's directions, placed in the preparation in 1-mm increments and photocured for 40 seconds. The last increment was covered with a plastic strip and a glass slide before curing to create a smooth surface. Repairs were accomplished by drying the specimen for 10 seconds, then adding the new material to the unprepared surface using a 3-mm-thick polytetrafluoroethylene mold. The specimens were thermocycled 500 times, stored in 37 degrees C distilled water for 1 week, then loaded to failure in shear at a rate of 0.5 mm/min. Data were analyzed using a one-way ANOVA and Z-value multiple comparison test to determine significant differences at the 0.05 significance level. Vitremer showed no significant difference in shear bond strength for 5-minute and 1-week repair periods, while Fuji II LC and Photac-Fil did. Repair bond strength of Vitremer was significantly greater than Fuji II LC and Photac-Fil at both repair times. This study showed that time of repair significantly affected the bond strength of two of the materials tested.

Analysis of Variance↗

The use of visible light-curing resin for vertebral body replacement.

The technology of visible light-curing resin has recently been developed for use in removable prosthodontics. A quartz halogen lamp producing a 400- to 500-nanometer wave-length spectrum of visible light is used to polymerize high-molecular-weight acrylic resin monomers. While several in vitro and in vivo studies of visible light-curing resin are found in the dental literature, no studies have yet been performed to evaluate it as an intracorporeal implant in surgery. The authors have designed a rat model of microcervical corpectomy to assess vertebral body replacement with visible light-curing resin in comparison to conventional autopolymerizing methyl methacrylate. Spinal cord function tests, spinal-implant stability assessments, and histological evaluations were made in a total of 41 rats at 2, 4, or 6 months postimplant. No animal developed a neurological deficit or radiographic instability, and at sacrifice there was no evidence of implant fracture-extrusion. In addition, there were no signs of adverse reaction in the surrounding tissues. Morphological investigation of the resin/bone interface at 6 months revealed very good implant anchorage. Visible light-curing resin was found to be far superior to methyl methacrylate for construction of spinal implants. Its waxy consistency makes it easy to handle. It remains pliable until light is applied, allowing adjustments in shape for a well-fitted implant without time constraints. Applied in layers, adjustments can be made even after polymerization of a previous layer. This new implantable resin will allow safer, immediate stabilization in patients with neoplastic destruction of the spine, and may also be advantageous for other neurosurgical applications, such as cranioplasty.

Animals↗

Factors that affect the shear bond strength of multiple component and single bottle adhesives to dentin.

PURPOSE: To examine the effects of thermocycling and the long-term integrity of the bonds between adhesive and resin composite to bovine dentin using multi-step and single bottle adhesive systems. MATERIALS AND METHODS: Dentin bonding sites were prepared using water irrigated #600 grit SiC paper on bovine incisor crowns mounted in acrylic resin. A 4 mm diameter area of dentin was etched, rinsed, left visibly moist and adhesives applied according to the manufacturers' instructions. The adhesives were: Scotchbond Multipurpose, Single Bond, All Bond 2, One Step, and Prime & Bond 2.1. Cylinders of Z100 resin composite 4 mm in diameter were positioned over the adhesive and visible light-cured. Bonded specimens were divided into five groups each containing 12 samples and: (1) stored in water for 24 hours; (2) stored in water for 7 days; (3) stored in water for 270 days; (4) thermocycled after 24 hours and stored for a total lapsed time of 7 days; (5) stored in water for 6.5 days, and thermocycled for a total lapsed time of 7 days. All storage temperatures were 37 degrees C. All specimens were shear (SBS) tested to failure at the end of each storage period, the results converted to MPa and the mode of fracture failure recorded. RESULTS: The SBS for all five adhesives deteriorated over time; the effects of thermocycling were shown to be variable and dependant upon the adhesive; the modes of fracture failure were shown to be adhesive/cohesive or mixed; after long-term (270 days) storage there was an increased tendency for adhesive/cohesive fracture failure.

Acetone↗

Comparison of retentiveness of amalgam bonding agent types.

Previous studies on amalgam bonded restorations indicated that amalgam bonding agents increased the bond strength of amalgam to tooth structure. This in vitro study was designed to compare how the mode of curing and the presence of filler in the resin would affect the bond strength of amalgam. The five test groups of lining agents for amalgam restorations included Chemical-cured, Unfilled resin (CU-Clearfil New Bond); Light-cured, Unfilled resin with a delayed chemical-cure property (LU*-Clearfil Photo Bond); Light-cured, Filled resin with a delayed chemical-cure property (LF*-Clearfil Photo Bond + Protect Liner); Dual-cured, Unfilled resin (DU-All-Bond 2); and Varnish (V-Copalite). For each group, 20 class 5 cavity preparations were cut on the facial, lingual, or proximal surfaces of human molars, which were embedded in acrylic resin. The preparations were 2.5 mm deep and 3 mm wide at the pulpal floor with a slightly divergent taper. After treating the preparation with the bonding agent, a 3/4-inch, 18-gauge flat-headed wire nail was placed into the cavity with the head at the pulpal floor of the preparation, and Tytin amalgam was then condensed into the preparation around the nail. The restorations were stored for 24 hours in distilled water at 37 degrees C and then subjected to 2500 thermal cycles (8 degrees C to 48 degrees C). After 1 week, specimens were tested to failure in tension using an Instron Universal Testing Machine (crosshead speed = 2 mm/min) and peak load (kg) was recorded. The mean loads at failure (+/- SD) were LF* 26.4 (+/- 7.0), DU 23.9 (+/- 6.4), LU* 16.0 (+/- 3.1), CU 14.3 (+/- 8.0), and V 9.5 (+/- 5.6). Significant differences were found using a one-way ANOVA and the Games and Howell post hoc test at a significance level of alpha = 0.05. The LF* and DU groups were not significantly different from each other, but they were significantly higher in peak load than all other groups. LU* was significantly higher than the varnish (V) but not significantly higher than CU. CU was not significantly higher than the varnish (V). The adhesives forming a thicker resin interface (the light-cured resin with filled resin liner and the dual-cured unfilled resin) demonstrated significantly greater retention than the light-cured unfilled resin, chemical-cured unfilled resin, and the varnish control.

Adhesiveness↗

Effect of disinfectant application methods on the bond strength of composite to dentin.

The use of cavity disinfectants with composite resins has raised important questions regarding their potential adverse effects on bond strength. The purpose of this study was to evaluate the effect of cavity disinfection on the bond strength of composite resin to dentin. Buccal surfaces of 64 caries-free extracted human third molars were ground flat by diamond flat-end cylinder bur, polished with a series of silicon carbide abrasive papers and mounted in autopolymerizing acrylic resin. They were randomly distributed into four groups (of 16). In group 1 (control group), dentin surfaces were treated with 35% phosphoric acid, Permagen primer and Permagen bonding resin and no disinfectant was used. In group 2, cavity disinfectant was applied and acid etching, priming and bonding procedures were performed as in group 1. In group 3, cavity disinfectant was applied after acid etching. In group 4, cavity disinfectant was applied as in group 3, but it was rinsed off before priming and bonding procedures. Then a Teflon mould 3 mm thick and 4 mm in diameter was attached to the dentin surfaces, filled with composite resin and light polymerized. After the specimens had been thermocycled, shear bond strengths were determined. Application of the disinfectant before or after acid etching significantly reduced the shear bond strength of composite to dentin (P<0.05). Rinsing off the cavity disinfectant before the bonding procedure did not affect the bond strength (P>0.05). The use of cavity disinfectant with composite resin restorations can influence the dentin bond strength.

Acid Etching, Dental↗

In vitro and in vivo replication for scanning electron microscopy of the cervical region of human teeth.

A replica technique for scanning electron microscopy (SEM) of the cervical region of human teeth was evaluated on extracted premolar teeth by comparing the replicas and the original specimens in the SEM. For in vivo application, the technique was modified to circumvent contamination by saliva and gingival exudate. Impressions were taken with an addition silicone polyvinylsiloxane material and the replicas were poured in epoxy resin die material. A surface active dentine conditioner facilitated flow of the impression material into irregular surface areas; in vivo a scavenger impression was used to remove surface debris. Custom trays were made of light-cured acrylic resin for the in vivo impressions. The method faithfully reproduced surface detail in the amelocemental region. In vivo the scavenger impression followed by application of the surface-active conditioner effectively cleaned the tooth surface. The custom tray allowed selection and inclusion of landmarks and ensured reproducibility. The method meets the requirements of a simple, reproducible, non-invasive means of documenting the micromorphology of the cervical region of the teeth.

Bicuspid↗

Self-etching primer vs phosphoric acid: an alternative concept for composite-to-enamel bonding.

The purpose of this in vitro study was (1) to investigate the composite-to-enamel bond strength and (2) to analyze the marginal adaptation of resin composite restorations in class 2 cavities using three self-etching priming agents in comparison to conventional phosphoric acid etching and bonding application. In the first part of the study 24 extracted bovine incisors were embedded in acrylic resin and ground flat with 800-grit paper. The following three self-etching priming agents/composite resins were applied to the enamel surfaces of six teeth each: Clearfil Liner Bond 2/Clearfil AP-X (Group I), Etch & Prime 3.0/Degufill mineral (Group II), Resulcin AquaPrime + MonoBond/Ecusit (Group III). In Group IV Ecusit-Mono/Ecusit was used after enamel etching with phosphoric acid (37%). Shear bond strength values measured on a T22 K testing machine at a crosshead speed of 1 mm/min were: 24.2 +/- 3.0 MPa (Group I), 21.9 +/- 1.4 MPa (II), 34.0 +/- 3.6 MPa (III), and 26.3 +/- 1.8 MPa (IV). ANOVA revealed significant (P < 0.05) differences in shear bond strength between groups, except comparison of Group I and II, and Group I and IV. In the second part of the study 24 standardized class 2 cavity preparations with the approximal box extending 1 mm above the CEJ were prepared in extracted human molars. Enamel margins were beveled and the teeth were divided into four groups of six teeth each. Cavities were restored using the self-etching priming agents Clearfil Liner Bond 2 (Group I), Etch & Prime 3.0 (Group II), and Resulcin AquaPrime + MonoBond (Group III). In Group IV composite resin restorations were placed after 37% phosphoric acid etching and bonding application (Ecusit-Mono). Quantitative SEM analysis of the marginal adaptation of the restorations after thermocycling (5-55 degrees C, 2500 cycles) and mechanical loading (100 N, 500,000 cycles) revealed excellent, gap-free margins in 91.2% (Group I), 93.0% (Group II), 92.0% (Group III), and 92.5% (Group IV) of the restorations' approximal area. There were no statistically significant differences between the four groups (P < 0.05). In conclusion, results of the present in vitro study indicate that use of self-etching primers may be an alternative to conventional phosphoric acid pre-treatment in composite-to-enamel bonding restorative techniques.

Acid Etching, Dental↗

[Tensile strength of short-fiber-reinforced temporary plastics].

Glass fibers added to temporary crown and bridge material (Proviso-Blend, Blendax) by 5% to the weight increased the tensile strength of the acrylic resin by 38%. The increase was even greater when carbon fibers were added (50%), but the resin discoloured to a greyish shade. The results were less spectacular with Dentalon Plus (Kulzer), and the experiment did not work with Protemp (Espe). The amount of improvement in tensile strength depended on the type and geometry of the fiber and of the fiber concentration. Neither the properties of the polished surface of a fiber-reinforced acrylic nor adverse effects of such fibers possibly swallowed by the patient are investigated as yet.

Composite Resins↗

An in vitro investigation of a comparison of bond strengths of composite to etched and air-abraded human enamel surfaces.

PURPOSE: The purposes of the study were to measure the tensile bond strength of composite resin to human enamel specimens that had been either etched or air-abraded, and to compare the quality of the marginal seal, through the assessment of microleakage, of composite resin to human enamel specimens that had been either etched or air-abraded. MATERIALS AND METHODS: Thirty mandibular molar teeth were decoronated and sectioned mesio-distally to produce six groups, each containing ten specimens that were embedded in acrylic resin using a jig. In each of the four treatment groups, the specimen surfaces were treated by either abrasion with 27 or 50 microm alumina at 4 mm or 20 mm distance, and a composite resin was bonded to the treated surfaces in a standardized manner. In the two control groups the specimens were treated with 15 seconds exposure to 36% phosphoric acid gel and then similarly treated before being stored in sterile water for 1 week. All specimens were then subjected to tensile bond strength testing at either 1 or 5 mm/min crosshead speed. For the microleakage study, the degree of dye penetration was measured 32 times for each treatment group, using a neutral methylene blue dye at the interface between composite and either 27 or 50 microm air-abraded tooth structure or etched enamel surfaces. RESULTS: The mean bond strength values recorded for Group 1 (phosphoric acid etch, 5 mm/min crosshead speed) was 25.4 MPa; Group 2 (phosphoric acid etch, 1 mm/min), 22.2 MPa; Group 3 (27 microm alumina at 4 mm distance), 16.8 MPa; Group 4 (50 microm alumina at 4 mm distance), 16.9 MPa; Group 5 (27 microm alumina at 20 mm distance), 4.2 MPa; and for Group 6 (50 microm alumina at 20 mm distance) 3.4 MPa. An analysis of variance (ANOVA) demonstrated significant differences among the groups, and a multiple comparison test (Tukey) demonstrated that conventionally etched specimens had a greater bond strength than air-abraded specimen groups. No significant difference in dye penetration could be demonstrated among the groups (p= 0.58). CONCLUSIONS: Composite resin applied to enamel surfaces prepared using an acid etch procedure exhibited higher bond strengths than those prepared with air abrasion technology. The abrasion particle size did not affect the bond strength produced, but the latter was adversely affected by the distance of the air abrasion nozzle from the enamel surface. The crosshead speed of the bond testing apparatus had no effect on the bond strengths recorded. The marginal seal of composite to prepared enamel was unaffected by the method of enamel preparation.

Acid Etching, Dental↗

Color change in acrylic denture base resin reinforced with wire mesh and glass cloth.

In this study, the L*a*b* color system as a color system and light transmittance of the denture base resin reinforced with wire mesh and glass cloth were measured, and the color difference (deltaE*ab) was calculated using L*, a* and b* values which were measured both on a white calibration plate and on a null background. The thicknesses of test specimens, which were reinforced with wire mesh and glass cloth 0.5 and 1.0 mm below the surface, were 3 and 5 mm. L*, a* and b* values of wire mesh reinforcing specimens decreased in comparison with the non-reinforcing specimens (p<0.05). L* values of glass cloth-reinforcing specimens increased compared with the non-reinforcing specimens (p<0.05). The glass cloth is an effective reinforcing material and an aesthetically important property of denture base resin, since wire mesh makes the resin appear darker with the background condition greatly altering the color, while glass cloth makes the resin lighter.

Acrylic Resins↗

Influence of salivary contamination on marginal microleakage of pit and fissure sealants.

PURPOSE: To assess quantitatively the influence of salivary contamination in vitro on marginal microleakage of pit and fissure sealants. METHODS: Forty-eight sound human third molars were selected and assigned to three groups: 1) Fluroshield (F), 2) Single Bond + Fluroshield (SBF) and 3) Ketac-fil (KF). Each group was divided into two subgroups: control (C) and with salivary contamination (SC). The occlusal surfaces were etched with 40% polyacrylic acid for 10 seconds or 37% phosphoric acid for 30 seconds, for either glass-ionomer or resin-based sealants, respectively. Specimens were contaminated with 0.25 mL of fresh human saliva for 20 seconds and dried afterwards. The sealants were placed and samples were thermocycled, immersed in a 0.2% Rhodamine B solution for 24 hours, embedded in acrylic resin and serially sectioned. The sections were viewed under an optical microscope connected to a computer and a video camera, and the images obtained were digitized. The extent of dye penetration along buccal and lingual slopes was measured in millimeters, using specific computer software, and converted into percentage, according to the fissures extension. RESULTS: The microleakage means (%) were: F/C:0 (+/- 0); F/SC: 31.71 (+/- 31.69); SBF/C: 0 (+/- 0); SBF/SC: 0 (+/- 0); KF/C: 0.98 (+/- 2.79) and KF/SC: 11.82 (+/- 15.45). ANOVA and Tukey test showed that salivary contamination provided significant increase in microleakage. Under salivary contamination, only SBF provided complete marginal sealing. When F and KF were compared, the glass-ionomer cement yielded the best sealing.

Acid Etching, Dental↗

Effect of ultrasonic vibration on dentin bond strength and resin infiltration.

PURPOSE: To apply a vibration technique to compare the bond strength and resin penetration depth into the dentin tubules with those gained using conventional techniques. METHODS: Eighty-eight noncarious extracted human permanent molar teeth were sectioned to remove the coronal enamel. They were embedded in a 1-inch PVC pipe with an acrylic resin. The occlusal surfaces were placed so that the tooth and the embedding medium were at the same level to form a single flat surface. The samples were subsequently polished with silicon carbide abrasive papers, and randomly assigned to four groups (n=22). In Groups 1 and 2, Single Bond was used, and in Groups 3 and 4, One-Step was used. Each adhesive system was applied according to its manufacturer's instructions. For Groups 2 and 4, vibration was applied with an ultrasonic scaler for 10 seconds, and the adhesive was light-cured for 10 seconds. The resin composite was condensed onto the prepared surface in two increments using a Teflon mold and each increment was light-cured for 40 seconds. After 24 hours soaking in tap water at room temperature, the specimens were thermocycled, and the shear bond strengths were measured using a universal testing machine. One-way ANOVA test followed by Student-Newman-Keuls test (P < 0.05) were used to analyze the results. To investigate the infiltration patterns of the adhesive materials, the surface of the specimens was examined with electron microscopy. RESULTS: The shear bond strengths of the vibration groups (Groups 2, 4) were significantly higher than those of the non-vibration groups (Groups 1, 3). The shear bond strengths of Single Bond and One-Step were not significantly different. The vibration groups showed greater numbers of resin tags in the tubules and lateral branches under SEM than the non-vibration groups.

Analysis of Variance↗

Long- and short-term space maintenance following the uprighting of molars: a case report.

The technique of using a light-hardened glass-ionomer-resin cement restorative material and a stainless steel round wire as a long-term retentive space maintainer following the uprighting of mandibular molars is introduced through the report of a clinical case. The technique is modified for incorporation into provisional acrylic resin restorations as a short-term retentive space maintainer in the time interval between the impression and the cementation of the fixed partial denture.

Adult↗