Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Pulsatile Flow”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

Limb salvage in diabetics: challenges and solutions.

Our current understanding of wound healing in the diabetic suggests that proper management of the blood glucose level is a necessary but not sufficient condition for containment of infection and optimal wound healing. The pathologic changes observed in the peripheral capillary bed of diabetics are somewhat variable and have no consistent relationship to the wound healing process. Occlusive disease of the arterioles is probably quite similar in significance and distribution to normoglycemic patients with peripheral vascular disease and suggests that proximal arterial occlusion is the major determinant of poor distal perfusion. These observations offer strong evidence that sufficient runoff vessels are present to support attempts at reconstruction of obstructing lesions of the aortoiliac and infrainguinal arterial segments. Noninvasive vascular laboratory data and arteriograms must be carefully interpreted in order to assess fully the degree of arterial occlusive disease that exists as well as the potential for vascular reconstruction. Clinical experience is especially helpful in proper patient selection. Aggressive attempts at distal revascularization can achieve functional limb salvage in the great majority of patients, provided that meticulous technical standards are observed. Conservative surgical debridement and minor amputations are often successful in managing problems of soft-tissue necrosis once pulsatile flow has been restored.

Aortic Diseases↗

Function-structure relationship of elastic arteries in evolution: from microfibrils to elastin and elastic fibres.

Evolution of species has led to the appearance of circulatory systems including blood vessels and one or more pulsatile pumps, typically resulting in a low-pressurised open circulation in most invertebrates and a high-pressurised closed circulation in vertebrates. In both open and closed circulations, the large elastic arteries proximal to the heart damp out the pulsatile flow and blood pressure delivered by the heart, in order to limit distal shear stress and to allow regular irrigation of downstream organs. To achieve this goal, networks of resilient and stiff proteins adapted to each situation--i.e. low or high blood pressure--have been developed in the arterial wall to provide it with non-linear elasticity. In the low-pressurised circulation of some invertebrates, the mechanical properties of arteries can almost be entirely microfibril-based, whereas, in high-pressurised circulations, they are due to an interplay between a highly resilient protein, an elastomer in the octopus and elastin in most vertebrates, and the rather stiff protein collagen. In vertebrate development, elastin is incorporated in elastic fibres, on a earlier deposited scaffold of microfibrils. The elastic fibres are then arranged in functional concentric elastic lamellae and, with the smooth muscle cells, lamellar units. The microfibrils may also play a direct functional role in all mature arteries of high- and low-pressurised circulations. Finally, since blood pressure regularly increases with developmental stages, it appears possible that the early deposition of microfibrils, which are highly-conserved in evolution, corresponds, at least in part, to an early microfibril-driven elasticity in low-pressurised arteries, present across species. In vertebrates, when pressure developmentally rises above a threshold value, the vascular wall stress may turn on the expression of other resilient protein genes, including the elastin gene. Elastin would then be deposited on microfibrils and resulting in the elastic fibre network and elastic lamellae whose mechanical properties are adapted to allow for proper arterial work at higher pressures.

Animals↗

Current uses of diagnostic high-frequency US in dermatology.

OBJECTIVE: The diagnosis of most skin diseases, both focal and diffuse, has long relied mainly on physical examination findings. The recent introduction of technologically advanced ultrasound equipment using 20 MHz probes has permitted the specific application of ultrasound to dermatology. Accordingly, we investigated whether the findings at very high frequencies can represent a valid adjunct to clinical assessment in many skin conditions, including neoplasms, inflammatory states and diseases of unknown origin. MATERIALS AND METHODS: Skin lesions are studied using high frequency probes, which very clearly detail the three layers (epidermis, dermis and subcutaneous tissues) forming the normal skin. The choice of the probes frequency should depend mainly on the lesion diameters and site. Electronic 7.5-13 MHz linear probes depict flat and regular surfaces effectively and provide a wider field of surface vision and, therefore, a wider view than sectorial probes. Water bath sectorial mechanical probes with 10-20 MHz frequency have very superficial focusing and are excellent to study irregular surfaces. RESULTS: High frequency ultrasound can be usefully correlated with clinical tests to study focal skin lesions. The diagnosis of most benign skin cancers is usually made on clinical bases. Ultrasound examinations are performed preoperatively in questionable cases. Malignant neoplasms appear at ultrasound as hypoechoic focal lesions, generally with no specific features in relation to the histologic type; nevertheless, preoperative ultrasound may play an important role in that it measures the thickness of cutaneous melanoma, which is a very important prognostic factor. In particular, 20 MHz probes permit to assess the depth of melanoma invasion. The sonographic evaluation of melanoma thickness is usually in agreement with histologic findings. 'Satellite' neoplastic lesions growing near the main tumor can also be revealed. Color and power Doppler studies may be combined with gray-scale imaging: the identification of abnormal intra- or peritumoral low-resistance pulsatile flow signals suggests the malignant nature of the cutaneous lesion. High frequency ultrasound can also be used to study diffuse cutaneous conditions. Among them, ultrasound can provide a valid morphologic representation of psoriatic skin lesions and it is also a noninvasive and accurate method for evaluating the therapeutic efficacy of antipsoriatic drugs. In scleroderma, sonographic findings vary depending on disease activity and the patterns vary; therefore, 20 MHz probes may also prove useful over the other instrumental tools to monitor the disease course and treatment efficacy in focal scleroderma. Other potential applications include allergic dermatitis, nodular erythema, dermatomyosis, sarcoidosis, lymphedema of the limbs and allergologic conditions. Ultrasound can also be used in monitoring the response to or complications of topic drugs administration, and in the follow-up of focal burns. CONCLUSION: High frequency ultrasound can provide a reliable morphologic representation of skin lesions but it is also an accurate noninvasive tool for monitoring the therapeutic efficacy of drugs administration in focal or diffuse diseases. The application of high frequency studies to dermatology is very challenging. Indeed, the very high frequency probes up to 20 MHz currently available are particularly useful for reliable studies. Contrast-enhanced color and power doppler are very promising techniques. Advancements in technology will improve the correlation of clinical with high frequency ultrasound findings in the assessment of several skin diseases.

Humans↗

[Vascular effects of ketamine during anesthesia with diazepam and fentanyl].

Twenty-six adults undergoing elective cardiac surgery were anaesthetized with diazepam and fentanyl (induction with 200 micrograms.kg-1 and 30 micrograms.kg-1 respectively, maintenance with incremental doses). Normothermic constant perfusion output cardiopulmonary bypass was carried out with a membrane oxygenator, haemodilution with Ringer's lactate solution, and cardioplegia with St. Thomas's Hospital solution. The patients were randomly assigned to two groups. They were given either 2 mg.kg-1 of ketamine (group 1) or placebo (5 ml of normal saline) (group 2) via the venous line of the oxygenator. The non pulsatile flow was then kept at a steady rate of 2.41 x min-1.m-2, and no other infusion or treatment was started during the study period (ten minutes). The mean arterial pressure and blood reservoir level were measured every min during this period. The systemic vascular resistances did not change significantly in either group, but remained 27% lower in the ketamine group than in the placebo group (p less than 0.01). The blood reservoir level was 37% higher in the ketamine group (p less than 0.01), suggesting a decreased venous capacitance. It is therefore concluded that ketamine leads to venous constriction, and probably arterial dilation, during fentanyl-diazepam anaesthesia and normothermic cardiopulmonary bypass. The venous effects of ketamine could explain why it is usually well tolerated in hypovolaemic states.

Aged↗

[Mechanical methods of treating refractory cardiac failure].

Mechanical means tend to be used more frequently nowadays for the treatment of congestive heart failure which does not respond to more normal treatment. The indications and limits of such devices, as well as their cost, must be defined. The new problem created by these therapeutic tools is the evolution of the underlying cardiac disease: should it improve the patient will be weaned from the machine, whereas if it worsens heart transplantation would be the only answer. Three types of mechanical support are described. Balloon pumping, and especially intra-aortic balloon pumping, is the technique used most often. It has a true but limited efficacy. Its best indication is cardiogenic shock by left ventricular ischaemia with normal or slightly increased peripheral resistances. Intrapulmonary balloon pumping is occasionally used, but the system can only be set up surgically. Its best indication would seem to be right-sided heart failure by pulmonary hypertension. Circulatory assistance is the second type considered. All types of bypass pumps can be used. The output used is usually less than the patient's theoretical output, the aim being to allow the myocardium to recover. Vascular access for these pumps is either femoral or intrathoracic. An oxygenator may or may not be added to the bypass circuit, and support may be mono- or biventricular. Although the non pulsatile flow has not been shown to be detrimental, this has to be investigated further. The use of these devices is limited by their effects on blood coagulation and pulmonary function. The artificial heart or artificial ventricles are the last devices described.(ABSTRACT TRUNCATED AT 250 WORDS)

Costs and Cost Analysis↗

Three-dimensional echocardiographic determination of left ventricular volumes and function by multiplane transesophageal transducer: dynamic in vitro validation and in vivo comparison with angiography and thermodilution.

The goal of this study was to validate 3-dimensional echocardiography by multiplane transesophageal transducer for the determination of left ventricular volumes and ejection fraction in an in vitro experiment and to compare the method in vivo with biplane angiography and the continuous thermodilution method. In the dynamic in vitro experiment, we scanned rubber balloons in a water tank by using a pulsatile flow model. Twenty-nine measurements of volumes and ejection fractions were performed at increasing heart rates. Three-dimensional echocardiography showed a very high accuracy for volume measurements and ejection fraction calculation (correlation coefficient, standard error of estimate, and mean difference for end-diastolic volume 0.998, 2.3 mL, and 0.1 mL; for end-systolic volume 0.996, 2.7 mL, and 0.5 mL; and for ejection fraction 0.995, 1.0%, and -0.4%, respectively). However, with increasing heart rate there was progressive underestimation of ejection fraction calculation (percent error for heart rate below and above 100 bpm 0.59% and -8.6%, P < .001). In the in vivo study, left ventricular volumes and ejection fraction of 24 patients with symmetric and distorted left ventricular shape were compared with angiography results. There was good agreement for the subgroup of patients with normal left ventricular shape (mean difference +/-95% confidence interval for end-diastolic volume 5.2+/-6.7 mL, P < .05; for end-systolic volume -0.5+/-8.4 mL, P = not significant; for ejection fraction 2.4%+/-7.2%, P = not significant) and significantly more variability in the patients with left ventricular aneurysms (end-diastolic volume 23.1+/-56.4 mL, P < .01; end-systolic volume 5.6+/-41.0 mL, P = not significant; ejection fraction 4.9%+/-16.0%, P < .05). Additionally, in 20 critically ill, ventilated patients, stroke volume and cardiac output measurements were compared with measurement from continuous thermodilution. Stroke volume as well as cardiac output correlated well to thermodilution (r = 0.89 and 0.84, respectively, P < .001), although both parameters were significantly underestimated by 3-dimensional echocardiography (mean difference +/-95% confidence interval = -6.4+/-16.0 mL and -0.6+/-1.6 L/min, respectively, P < .005).

Adult↗

Right ventricular support for off-pump coronary artery bypass grafting studied with bi-ventricular pressure--volume loops in sheep.

OBJECTIVES: Tilting the heart during off-pump coronary artery bypass grafting (OPCABG) causes a strong decrease in cardiac output. It is hypothesized that this decrease is caused by reduced right ventricular filling and that right ventricular support is thus the best way to restore cardiac output. Simultaneous left and right ventricular pressure-volume loops were used to test this hypothesis. METHODS: In seven sheep, the heart was tilted with the use of an Octopus device. After unsupported tilting, a novel right ventricular support, the Enabler, was activated at a pulsatile flow of 1.6 l/min. Pressure-volume loops of both ventricles were obtained using conductance catheters, and cardiac output was monitored with an aortic flow probe. RESULTS: Tilting reduced cardiac output by 31% (4.4--3.1 l/min, P=0.001) and right ventricular end-diastolic volume by 44% (86--51 ml, P=0.005), while right ventricular end-diastolic pressure did not decrease. Left ventricular systolic pressure was not significantly reduced upon tilting and even increased in two animals. During Enabler right ventricular support, the cardiac output remained 23% lower than pre-tilting values (3.4 vs. 4.4 l/min, P=0.001). CONCLUSIONS: Restricted right ventricular filling is the primary cause of the strong decrease in cardiac output during tilting. The Enabler right ventricular support can currently not restore cardiac output to pre-tilting values, mainly caused by its limited output and a decrease in right ventricular output upon Enabler activation. Constant monitoring of cardiac output is crucial during (unsupported or supported) tilting as blood pressure alone may not reflect the extent of the reduction in cardiac function.

Animals↗

The influence of size mismatch on the hemodynamic performance of the pulmonary autograft in vitro.

OBJECTIVES: We established an in vitro model to investigate the effect of size mismatch between the aortic and pulmonary root on the hydrodynamic performance and leaflet motion of the pulmonary autograft. METHODS: Ten fresh porcine pulmonary roots (annulus diameter: 19-25 mm) were tested in a pulsatile flow simulator. The autografts then were implanted in fresh porcine aortic roots (annulus diameter: 19-30 mm) and retested in the flow simulator. Three roots were oversized by 21-39%, three were undersized by 32-45% and there were four size for size implantations. The external diameter of the roots and autografts was measured at the sinotubular junction at hydrostatic pressures of 0 - 120 mmHg. The transvalvular gradient and regurgitation were also measured and the effective orifice area was calculated. The leaflet motion was recorded on video. RESULTS: The fresh pulmonary roots were more compliant than the fresh aortic roots (46 +/- 8.4% vs. 35 +/- 7.8% dilatation from 0 to 120 mmHg). The group of matching size autografts dilated by 43 +/- 4.9% in the same pressure range. The external diameter of the undersized autografts was 10 +/- 2.1% bigger than before implantation at 0 pressure and then the dilatation was 40 +/- 5.3% at 120 mmHg. The oversized implantation made the autografts 11 +/- 9.4% smaller in their relaxed state, but then they dilated by 65 +/- 11% as the pressure increased to 120 mmHg, resulting in a net dilatation of 54% over the original undilated state. The under or oversizing had little effect on the pressure gradient measured across the valves (5.6 +/- 2.57 mmHg before, 6.3 +/- 3.27 mmHg after implantation). Only the oversized valves showed significantly higher gradients than the native pulmonary valves. The effective orifice area of the undersized autografts was slightly bigger and the oversized autografts was slightly smaller after implantation, although the differences were not significant. The size mismatch did not cause regurgitation on the valves. The video images showed very low-open leaflet-bending deformation, both on the fresh pulmonary and the autograft valves. CONCLUSION: Under or oversizing the pulmonary autograft up to 40% of the annulus diameter did not affect the hydrodynamic parameters significantly. The compliance of the autograft root was able to compensate for the size mismatch without adversely influencing the valve performance.

Animals↗

The role of neuromonitoring in cardiovascular surgery.

This review describes the techniques currently used for quantitative neurophysiologic measurement during cardiac surgery and their potential impact on clinical outcome. Electroencephalography (EEG) characterizes cerebrocortical neuronal electrical activity and was part of some of the earliest cardiopulmonary bypass procedures, yet today it is not widespread use. Each of the common misunderstandings regarding a supposed limitation of this technology is explained. Its major genuine shortcoming, a lack of selectivity, may now be overcome with the combined use of additional monitoring modalities. The influence of intracranial hemodynamics on observed EEG changes may be determined continuously and noninvasively with transcranial Doppler (TCD) ultrasound. TCD provides an indication of sudden change in either blood flow or vascular resistance as well as the detection of emboli. In addition, the metabolic status of cortical neurons can be monitored by regional cerebral venous oxygen saturation (rCVOS) using noninvasive transcranial near-infrared spectroscopy. The % rCVOS tends to remain remarkably stable over a wide range of temperatures, perfusion pressures, and anesthetic states. Marked change in either direction signifies a serious imbalance between oxygen delivery and consumption. Measurement of rCVOS does not require blood flow, pulsatile or otherwise, so that it offers the only means of monitoring during circulatory arrest. By characterizing the dynamic interplay among cerebral hemodynamics, metabolism, and electrogenesis, these technologies permit the rapid detection and correction of potentially hazardous conditions.

Brain↗

Vena cava perfusion in situ: a tool for uptake studies.

While studying the uptake of trypsin and thrombin by the perfused rat liver, we verified that these proteins are internalized neither by hepatocytes nor Kupffer cells. These results raised the possibility that the enzymes might be binding to endothelial cells, either hepatic or vascular. In order to find out if the binding of enzymes to endothelial surface is a liver cell-specific phenomenon, we devised a system to perfuse the rat inferior cava vein in situ. After exsanguination, the vein was perfused with the recirculation of 30 mL of Krebs/BSA solution propellered by a pulsatile flow pump (10 mL/min). The liver was not exsanguinated, but to assure that the organ was indeed excluded from the circuit during the experiment at the end of the perfusion time we added China ink in the perfusion fluid. We verified that trypsin is extracted from the perfusion fluid by the vena cava as efficiently as by the liver, suggesting that the most of the infused trypsin is removed mainly by vascular endothelial cells when the liver perfusion model is used. On the other hand, thrombin is removed mainly by the liver cells since the uptake by the vena cava was insignificant.

Animals↗

In vitro evaluation of endovascular stents to assess suitability for endovascular graft fixation.

OBJECTIVE: To compare and ascertain the suitability for endovascular aortic graft fixation of the Palmaz stent, the Strecker stent, the modified Gianturco-Z stent, the Wallstent and a new stent made of the shape memory alloy nitinol. DESIGN, SETTING AND MATERIALS: In vitro studies using a simple tensiometer to assess the forces required to distract each stent from porcine aorta; and using a high-pressure, pulsatile-flow pump to measure flow rates required to dislodge stents holding grafts within porcine aortas, with assessment using endovascular ultrasound. RESULTS: The Palmaz, the modified Gianturco-Z and the nitinol stents resisted significantly greater distraction forces than the Wallstent, but endovascular ultrasound examination revealed that the modified Gianturco-Z stent was seen to move away from the aortic wall at high flow rates precluding adequate fixation. The Strecker stent could not be assessed using these techniques. CONCLUSIONS: A nitinol stent may be suitable for aortic graft fixation, has characteristics similar to the Palmaz stent and has shape memory effect which may overcome the difficulties of introduction of wider diameter stents through narrow arteries.

Alloys↗

Comparison of contrast-enhanced harmonic ultrasonography and power Doppler ultrasonography for depicting vascularity of hepatocellular carcinoma identified by angiography-assisted CT.

The sensitivity of contrast-enhanced harmonic gray scale imaging was compared with that of power Doppler sonography in depicting tumor vascularity and contrast enhancement of hepatocellular carcinoma (HCC) identified by angiography-assisted computed tomography (CT). One hundred thirty-nine classic HCC nodules (108 patients), each appearing as a high-attenuation mass on early-phase CT during hepatic arteriography and as a perfusion defect on CT during arterial portography, were evaluated. Vascular findings and contrast enhancement patterns were evaluated by contrast-enhanced harmonic gray scale imaging. Arterial pulsatile flow into each nodule was checked by power Doppler sonography. Sensitivity of each modality for depicting tumor vascularity was examined by angiography-assisted CT findings as the gold standard. The sensitivity of contrast-enhanced harmonic gray scale imaging (134/139, 96.4%) was significantly greater than that of power Doppler sonography (96/139, 69.1%) (P<0.05). Twenty-six of twenty-seven nodules (96.3%) in the lateral segment, in which motion artifact is likely, were enhanced by contrast-enhanced harmonic gray scale imaging. Contrast-enhanced harmonic gray scale imaging is more sensitive than power Doppler sonography and is a noninvasive method that can be used as effectively as angiography-assisted CT to evaluate tumor vessels and contrast enhancement of HCC.

Journal Article↗

The fast flush test--is the clinical comparison equivalent to its in vitro simulation?

OBJECTIVE: An in vitro simulation of the fast flush (FL) test has previously been used to prove that the FL test-measures the dynamic response of entire the blood pressure monitoring system. This simulation has also been used to confirm that the FL test is equivalent to the "gold standard" test for determining dynamic response, namely the square wave (SW) test. The conditions of the in vitro simulation can be reproduced in vivo during cardiopulmonary bypass (CPB) and circulatory arrest. Therefore the present objective was to verify that the previous conclusions about the validity of the FL test, obtained from an in vitro model, are equally valid when applied to in vivo clinical conditions. A secondary objective was to determine whether the patient's arterial tree has any affect on the dynamic characteristics of fluid-filled manometers. METHODS: Fourteen patients were studied during surgery that required CPB. We measured the dynamic response of the fluid filled arterial manometer during pulsatile conditions prior to the initiation of CPB, and then repeated the measurements during non-pulsatile CPB. In four of the fourteen patients we measured the dynamic response during circulatory arrest. A manometer, consisting of a fluid-filled tubing component, measured the patient's arterial blood pressure as well as the damped sinusoidal wave form created by the fast flush tests. The fluid-filled tubing was connected to a transducer (Utah Medical Products, Inc., Midvale, UT). The arterial pressures and the results of flush testing were recorded and displayed by a monitor (Marquette 7010, Marquette Electronics Inc., Milwaukee, WI). In an additional three patients we measured the dynamic response of the manometer in vitro and then in vivo. RESULTS: The dynamic response of the arterial pressure measuring system was the same during normal pulsatile flow, CPB and circulatory arrest. In addition, the dynamic response of the fluid-filled manometer was the same in vivo as in vitro. CONCLUSIONS: The clinical conditions during CPB and particularly during circulatory arrest duplicate the in vitro FL test simulation model. These results confirm the validity of the FL test in vivo as well as proving that the dynamic characteristics of a fluid-filled manometer are independent of the patient's vasculature.

Blood Pressure↗

Tissue engineering of ovine aortic blood vessel substitutes using applied shear stress and enzymatically derived vascular smooth muscle cells.

Compared to native blood vessels, all clinically available blood vessel substitutes perform suboptimally. Numerous approaches to tissue engineer (TE) blood vessels have been pursued using different scaffold materials, cell types, and culture conditions. Several limitations however remain to be overcome prior to the potential application in the arterial system. This study aimed at tissue engineering viable ovine blood vessels suitable for implantation into the systemic circulation of sheep. In recent studies vascular smooth muscle cells (vSMC) were derived by an explant technique. However, in this study we show that homogenous populations of differentiated vSMC were only obtained by enzymatic dispersion as characterized by immunostaining for specific vSMC marker proteins. In contrast the explant method yielded predominantly less differentiated myofibroblast-like cells. Enzymatically derived vSMC were seeded onto P-4-HB scaffolds and incubated either in a pulsatile flow bioreactor or under static conditions. Dynamically cultured TE blood vessel substitutes showed confluent layered tissue formation and were completely water resistant. They displayed significantly increased ECM synthesis, DNA, and protein content as well as vSMC marker expression. Mechanical properties of bioreactor cultured TE blood vessels approached those of native aorta. In conclusion ovine, aortic blood vessel substitutes were successfully created using enzymatically derived vSMC, bioabsorbable scaffolds, and applied shear stress.

Animals↗

Low-density lipoproteins inhibit endothelium-dependent relaxation in rabbit aorta.

The vascular endothelium, in response to pulsatile flow and vasoactive agents including acetylcholine, secretes the endothelium-derived relaxing factor (EDRF), a substance which regulates vascular tone. Recent interest in EDRF has focused on its possible dysfunction in atherosclerosis. In animal models of the disease, endothelium-dependent relaxation is markedly reduced. The continuous exposure of the endothelium in hyperlipidaemia to high concentrations of low-density lipoprotein (LDL), a known atherogenic risk factor, may explain this dysfunction. Here, we demonstrate that pathophysiological concentrations of LDL directly inhibit endothelium-dependent relaxation. Chemically modified LDL, in contrast, is inactive, implying that the inhibition is through a receptor-dependent mechanism.

Acetylcholine↗

Compliance properties of conduits used in vascular reconstruction.

BACKGROUND: Compliance mismatch between native artery and prosthetic graft used for infrainguinal bypass is implicated in the aetiology of graft failure. The aim was to quantify the elastic properties of a new compliant poly(carbonate)polyurethane (CPU) vascular graft, and to compare the compliance properties of grafts made from CPU, expanded polytetrafluoroethylene (ePTFE), Dacron and human saphenous vein with that of human muscular artery. METHODS: A pulsatile flow phantom was used to perfuse vessel and prosthetic graft segments at physiological pulse pressure and flow. Intraluminal pressure was measured using a Millar Mikro-tip catheter transducer and vessel wall motion was determined with duplex ultrasonography using an echo-locked wall-tracking system. Diametrical compliance and a stiffness index were then calculated for each type of conduit over mean pressures ranging from 30 to 100 mmHg by 10-mmHg increments. RESULTS: The compliance values of CPU and artery (mean over the pressure range) were similar (mean(s.d.) 8.1(0.4) and 8.0(5.9) per cent per mmHg x 10(-2) respectively), although the elastic behaviour of artery was anisotropic unlike CPU, which was isotropic. Dacron and ePTFE grafts had lower compliance values (1.8(1.2) and 1.2(0.3)per cent per mmHg x 10(-2) respectively, averaged over the pressure range). In both these cases, compliance and stiffness differed significantly from that of artery over a mean pressure range of 30-90 mmHg. Human saphenous vein exhibited anisotropic behaviour and, although compliant at low pressure (30 mmHg), was markedly incompliant at higher pressures. CONCLUSION: Compliant polyurethane grafts offer a greater degree of compliance match than either ePTFE or Dacron.

Arteries↗

Congenital absence of portal vein in the fetus: a case report.

Congenital absence of portal vein (CAPV) is a rare abnormality, which may be associated with other abnormalities. We report a case of prenatal diagnosis of absent portal vein confirmed on postnatal ultrasonography and computed tomography scan. The ultrasound features of CAPV include dilated intra-abdominal segment of umbilical vein, dilated inferior vena cava and the presence of hyperechogenic areas in the liver. Blood coming from the umbilical vein directly drains into the inferior vena cava. The dilated intra-abdominal segment of the umbilical vein shows high velocity pulsatile flow, resembling that of ductus venosus. These findings should prompt a careful search for the portal vein and any associated anomalies.

Adult↗

History of the Kolff Laboratory turbine driven electrohydraulic artificial heart.

The concept of an electrically powered total artificial heart has been pursued by Dr. Kolff and his associates since the 1960s. Since the 1980s these efforts have been concentrated upon the development of the electrohydraulic total artificial heart, a turbine pump powered by a brushless DC motor. Dr. Kolff realized the benefits of pulsatile flow and device response to Starling's Law, and these concepts have formed the basis of subsequent design decisions. Design iterations have both solved existing problems and exposed new challenges. The current device design is greatly improved over early attempts due to the incorporation of technologies that have recently become available as the result of progress in the fields of materials and electronics and due to the lessons learned over many years of research under the guidance of Dr. Kolff. This article describes, from its inception, the last major research project of Dr. Kolff prior to his retirement. The discussion centers around development, problems and their solutions, and the reasoning for given solutions.

Animals↗