Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Prothrombin”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

Quality control trials of prothrombin time: an assessment of the performance in serial studies.

A series of collaborative exercises on the one-stage prothrombin time test involving hospitals in Britain and overseas was performed between 1972 and 1977. The British Comparative Thromboplastin (BCT) and the lyophilised test plasmas were issued from the National (UK) Reference Laboratory for Anticoagulant Reagents and Control. Participants were asked to test the plasma samples with the BCT using the recommended technique. Variability of performance was assessed by the 'index of reliability' based on the plasma variance and error variance within each exercise. The results show that hospitals have attained higher precision in the later trials.

Humans↗

Survey of prothrombin time in National External Quality Assessment Scheme exercises (1980-87).

National External Quality Assessment Scheme surveys on the prothrombin time test carried out in hospitals in the United Kingdom have been performed at regular intervals since 1972. Performance has been assessed by comparing observed variability between hospitals with that predicted by a statistical model. The model was based on results from 53 survey plasmas issued between 1980 and 1987. These showed a linear correlation between logarithms of mean and standard deviation of reported ratios. Precision improved until the human brain thromboplastin, Manchester Comparative Reagent, was withdrawn in January 1986. There then followed a pronounced overall deterioration which, by October 1987, had not corrected to the levels achieved by 1985. When the recent results from 1986-87 were analysed according to Quick test reagent only one reagent (ISI 1.1) showed an improvement in precision. Performance of the other Quick test reagents, all with higher ISI values, had not regained the standards of precision previously achieved by the human brain reagent.

Animals↗

Field study of lyophilised plasmas for local prothrombin time calibration in The Netherlands.

AIM: To assess the effect of a lyophilised calibrant plasma procedure on the international normalised ratio (INR) and its interlaboratory variation. METHODS: INR equivalent values were assigned to five lyophilised plasmas (one from normal donors and four from coumarin treated patients) by a reference laboratory using three calibrated thromboplastin reagents. The calibrant plasmas and five artificial control blood specimens were mailed to 44 Dutch laboratories for prothrombin time (PT) determination. The assigned INR values were used to calculate calibration lines for each participant laboratory. The calibration lines were then used to translate the PT of the control specimens to INR. RESULTS: For all lyophilised plasmas and control blood samples, there were significant differences between INR values determined with the three thromboplastin reagents. These differences could not be explained by inaccuracy of the international sensitivity index or mean normal PT of the reagents and must, therefore, have been induced by the preparation procedures for the lyophilised plasmas and control blood samples. The interlaboratory variation of the INR obtained with the calibrant plasma procedure had a coefficient of variation (CV) ranging between 2.1% and 7.3% and tended to be lower than the interlaboratory variation found with the usual methods (3.0-12.2% CV). There was a good agreement between the mean INRs obtained with the calibrant procedure and those obtained using the normal methods. CONCLUSIONS: The present study highlights the limitations of some lyophilised plasmas and control blood samples. It is not possible to assign a single INR value to each of these lyophilised plasmas and control specimens that is valid for all thromboplastin reagents. Nevertheless, by using reagent specific INR equivalent values for the calibrant plasma procedure, the interlaboratory variation could be reduced.

Anticoagulants↗

Prothrombin time derived fibrinogen determination on Sysmex CA-6000.

AIM: To evaluate PT derived fibrinogen determinations with reference to the Clauss fibrinogen assay using a Sysmex CA-6000 random access coagulation analyser. METHODS: Samples were analysed from normal subjects (n = 20), patients with renal or liver dysfunction (n = 25), critically ill patients (n = 25), patients receiving oral anticoagulant treatment (n = 50), and patients with a haemoglobinopathy (n = 127). Prothrombin times were performed using two thromboplastins: one derived from rabbit brain (Dade: Thromboplastin IS) and the other from recombinant human tissue factor (Dade: Innovin). Fibrinogen was assayed by the Clauss method using a commercial kit (Dade: Fibrinogen). RESULTS: The relation between Clauss fibrinogen and PT derived fibrinogen was found to be dependent on the patient's clinical group and source of the thromboplastin used. When the data from the above sample groups were pooled there was still a significant difference (p < 0.001) between Clauss fibrinogen and PT derived fibrinogen, irrespective of thromboplastin used. CONCLUSIONS: It is unsafe to use the PT derived fibrinogen for patient monitoring owing to non-uniform variability in response to clinical status and reagent employed; however, it may prove to be a useful screening test in a research environment for estimating fibrinogen levels among defined patient groups.

Animals↗

European Concerted Action on Anticoagulation (ECAA). An assessment of lyophilised plasmas for ISI calibration of CoaguChek and TAS whole blood prothrombin time monitors.

AIMS: The recommended method for the international sensitivity index (ISI) calibration of whole blood point of care testing (POCT) prothrombin time (PT) systems was originally described by Tripodi et al in 1993 but is too complex and demanding. The present European Concerted Action on Anticoagulation (ECAA) study aimed to assess the reliability of simpler ISI calibration using lyophilised plasma samples. METHODS: ISI calibrations using three different types of ECAA lyophilised plasma samples (artificially depleted, individual, and pooled coumarin) were compared with whole blood calibrations on CoaguChek Mini and TAS PT-NC POCT monitors at 10 centres. RESULTS: With CoaguChek Mini systems, lyophilised coumarin plasma samples (both single donation and pooled) gave ISI and international normalised ratio (INR) values comparable to whole blood. With artificially depleted plasma, ISI and INR values were too high. With TAS PT-NC systems, all three types of lyophilised plasma samples gave inaccurate ISI and unreliable INR results, similar to previous ECAA findings with fresh plasma calibrations. CONCLUSIONS: With CoaguChek Mini systems, ISI calibration can be simplified by the use of ECAA lyophilised plasma samples from coumarin treated patients. Further study is needed to devise a simpler calibration method for the TAS PT-NC system.

Adult↗

Evaluation of solvent/detergent-treated plasma in patients with a prolonged prothrombin time.

OBJECTIVES: To compare the laboratory and clinical outcome of patients who received solvent/detergent-treated plasma (SDP) and fresh-frozen plasma (FFP). METHODS: A randomized, double-blinded study to assess the ability of SDP and FFP to reduce a prolonged prothrombin time (PT) to </=15 s in patients with acquired coagulation deficits. RESULTS: 45 patients (22 SDP vs. 23 FFP) were treated with 71 infusions. There were no significant differences in mean dose of plasma infused (7.8 ml/kg for SDP vs. 8.0 ml/kg for FFP, p = 0.46), percentage of patients who corrected their PT to </=15 s (32% for SDP vs. 26% for FFP, p = 0.67), or percentage of patients whose bleeding ceased (27% for SDP vs. 22% for FFP). CONCLUSION: No clinical or statistically significant differences were observed after infusion with SDP or FFP in patients with acquired coagulation deficits.

Adult↗

Homozygous prothrombin gene mutation and ischemic cerebrovascular disease: a case report.

We report the case of a 31-year-old woman who, at the age of 26 suffered from an episode of superficial thrombophlebitis in the left leg, experienced two episodes of transient ischemic attacks at the age of 30 and had an ischemic stroke with left-sided hemiparesis at the age of 31 years. A cerebral CT scan showed an ischemic lesion in the right sylvian area involving the opercular and nucleocapsular regions. Her father had had an ischemic stroke at the age of 54 years and died at the age of 58; her mother had had a myocardial infarction at the age of 48 years and died at 51 years from breast cancer. Laboratory investigation of the patient demonstrated high levels of fibrinogen, F II, F VII, F 1 + 2, FPA and ACA-IgG with low levels of HDL cholesterol associated with homozygosity for the 20210 A genotype. There were no other genetic or acquired prothrombotic defects. In conclusion, this case strongly suggests a clinically significant role ot the prothrombin gene mutation in both arterial and venous thrombosis.

Adult↗

Comparative study of a portable prothrombin time monitor employing three different systems in oral anticoagulant units.

The aim of this study was to evaluate the accuracy of the portable coagulometer CoaguChek (Roche Diagnostics) as a prothrombin time (PT) monitor, and to correlate capillary blood results with those of three different routine methods used for monitoring oral anticoagulant therapy (OAT): capillary, plasma and whole blood samples. Three hospitals participated in the study with a total of 235 patients on OAT. The international normalized ratio (INR) results obtained with CoaguChek were compared with those obtained using each of the routine methods. The study presents a good correlation between the PT monitor and the three methods studied: r = 0.9745 (hospital A), r = 0.9283 (hospital B), r = 0.9136 (hospital C). A simplified concordance test of the methods results in a nine-field comparison table showing concordances of 87.2, 85.7 and 68.4%, respectively. The absolute difference (mean +/- SD) between laboratory A and CoaguChek INRs was 0.0571 +/- 0.2042, with values of 0.04286 +/- 0.3906 for laboratory B and 0.6986 +/- 0.6170 for laboratory C. These results confirm that CoaguChek could be used as a new method for oral anticoagulant monitoring, and is in best agreement with the capillary blood PT system.

Humans↗

Frequency of factor V, prothrombin and methylenetetrahydrofolate reductase gene variants in preeclampsia.

BACKGROUND: The association between thrombophilic variants (Leiden mutation of the factor V gene, G20210A mutation of the prothrombin gene and C677T polymorphism of the methylenetetrahydrofolate reductase (MTHFR) gene) with preeclampsia was investigated in a north-eastern Italian population. METHODS: Fifty-eight preeclamptic (PE) women and 74 normal pregnancies were evaluated. Genotypes were determined by polymerase chain reaction. RESULTS: The frequency of heterozygous carriers of the factor V Leiden was similar between PE women (5.2%) compared to the control subjects (4.1%; p 0.76). Also the frequencies of G20210A and C677T mutations were similar between PE and control subjects. CONCLUSIONS: In this population, we found no difference in the prevalence of genetic risk factors for thrombosis in women with preeclampsia compared with control subjects.

Adult↗

Why is the standardization of prothrombin time a problem?

The standardization of prothrombin time (PT) has been a problem for more than 50 years; by applying the methods to the same clinical material the analysis may explain why. The initial standardization by 2--3 times normal clotting time by Quick's PT assay did not standardize presently used PT assays. The ratio method accepted by the WHO in 1977 was not satisfactory because the intercept was neglected. The revised ratio method (WHO 1983) recommended calibration between log clotting times of normal and abnormal plasmas and a simplified conversion into ratios. However, by including a high proportion of normal plasmas (up to 1/3 of abnormal) an erroneous calibration material was introduced; the conversion from clotting times into ratios was also more complex than predicted. The international sensitivity index, which is based on the simplified method, produced international normalized ratios (INR) that were not more standardized than not corrected ratios. Not corrected coagulation activities showed poor standardization due to the different sensitivity of assays for the protein induced by vitamin K absence (Pivka) inhibitor. The corresponding therapeutic ranges of INR and coagulation activities covered 70 and 10--20% of their scales, respectively. Standardization by Pivka-corrected coagulation activities against an international reference assay may be the preferable method.

Blood Coagulation Tests↗

Self-management of oral anticoagulants with a whole blood prothrombin-time monitor in elderly patients with atrial fibrillation.

The efficacy of oral anticoagulants (OAC) in reducing the incidence of stroke in elderly patients with atrial fibrillation (AF) has been well documented. The intensity of OAC therapy and deviations in the prothrombin time (PT) are the strongest risk factor for bleeding complications in elderly patients. The aim of this study was to evaluate a more rigorous regulation of OAC by the use of a portable whole blood PT-monitor (CoaguChek) in elderly patients with AF (age 65-80 years). The study group consisted of 20 patients, of whom 17 were evaluable, which were trained to use to CoaguChek monitor and adjust their anticoagulant dose for 12 months. The control group, 20 patients matched for age, gender and the duration of OAC treatment, were tested in an anticoagulant clinic and their OAC dose was adjusted by a physician. To validate the PT-monitor results, the patients performed a total of 129 simultaneous venous blood PT tests at various time points. The correlation coefficient R(2) was 0.707 indicating the accuracy of the CoaguChek results. The self-managed patients perform more frequent measurements 46 +/- 8.9 vs. 15.7 +/- 3.1 PT tests per patient. They demonstrated a within the therapeutic range INR in 80.5% of the tests (95% confidence interval, 76.5-84.1%) as compared to 72.4% (95% confidence interval, 68.5-76.5%) in the control group (p = 0.057). The median value for all CoaguChek International Normalized Ratio (INR) recordings was within therapeutic range in the self-management group as well as in the control group. There were fewer INR results below or above the therapeutic range in the study group. None of the patients had hemorrhagic or thrombotic events during the study. Overall, the study group expressed high satisfaction from using the home monitor. We conclude that home PT monitoring and self-management of OAC are feasible in a motivated population of elderly patients with atrial fibrillation and are probably cost effective.

Administration, Oral↗

Prothrombin G20210A mutation, but not factor V Leiden, is a risk factor in patients with persistent foramen ovale and otherwise unexplained cerebral ischemia.

BACKGROUND: Paradoxical embolism via persistent foramen ovale (PFO) is suspected to be a frequent cause of stroke in younger patients. We investigated whether the prevalence of the risk factors for venous thrombosis factor V Leiden (FVL) and prothrombin G20210A mutation (PT G20210A) is increased in this group of patients. METHODS: We examined FVL and PT G20210A mutation in 220 patients (group 1) with cerebral ischemia associated with a PFO and without other etiology, in 196 patients with cerebral ischemia of an etiology other than PFO (group 2), and in 362 healthy subjects (group 3) from the same region in Germany. RESULTS: Heterozygosity for the PT G20210A mutation was more common in group 1 (5.0%) than in group 3 (1.4%; sex- and age-adjusted odds ratio 3.66; 95% CI 1.25-10.75; p = 0.01). By contrast, the mutation was not more common in group 2 (2.6%; odds ratio 1.50; 95% CI 0.42-5.41; p = 0.5). Prevalences of FVL were not different between groups. CONCLUSIONS: We identified PT G20210A but not FVL - the strongest genetic risk factor for deep venous thrombosis - to be significantly associated with stroke attributed to PFO. These findings rise doubts about the concept of paradoxical brain embolism as the dominating mechanism in stroke associated with PFO.

Adult↗

Hyperhomocysteinemia and other newly recognized inherited coagulation disorders (factor V Leiden and prothrombin gene mutation) in patients with idiopathic cerebral vein thrombosis.

BACKGROUND: Idiopathic cerebral vein thrombosis (iCVT) represents approximately 30% of the cases of cerebral vein thrombosis (CVT). New, inherited - factor V Leiden (FVL) and prothrombin gene mutation (PTHRA20210) - and inherited/acquired - hyperhomocysteinemia (HHcy) - prothrombotic conditions have been detected recently. METHODS: We assessed fasting plasma homocysteine (Hcy) levels and main Hcy determinants, FVL and PTHRA(20210) in 30 patients with documented iCVT and 40 age- and sex-matched healthy subjects. RESULTS: A strong and significant association of PTHRA(20210) [30% (9/30) vs. 2.5% (1/40) iCVT vs. controls, respectively, p = 0.001; OR = 16.174, p = 0.002] and HHcy [13/30 (43.3%) vs. 4/40 (10%) iCVT vs. controls, respectively; p = 0.002, OR = 6.88, p = 0.002] with iCVT was found. CONCLUSIONS: PTHRA(20210) and HHcy should be considered when screening for thrombophilia and should be assessed in patients with a family or personal history of CVT.

Adult↗

Factor V gene (1691A and 4070G) and prothrombin gene 20210A mutations in patients with Behçet's disease.

OBJECTIVES: Behçet's disease (BD) is a chronic inflammatory disorder of still unknown etiology, characterized by endothelial cell injury/dysfunction and thrombosis and/or aneurysm of large blood vessels. Thrombophilia may play a role in the pathogenesis of thrombosis in BD. The common inherited gene defects, factor V (FV) 1691A (Leiden) and prothrombin (PT) 20210A, are known risk factors for thrombosis. The FV 4070G polymorphism was shown to influence circulating FV levels and to contribute to the activated protein C resistance phenotype. The aim of the study was to evaluate the role of FV 1691A, FV 4070G and PT 20210A gene mutations in Turkish BD patients with and without venous thrombosis. METHODS: Seventy-one patients with BD (27 with venous thrombosis) and 91 healthy subjects were included in the study. FV 1691A, FV 4070G, and PT 20210A mutations were determined by a method based on PCR-RFLP. RESULTS: The frequency of FV 1691A heterozygous mutation in BD patients with venous thrombosis (25.9%) was significantly higher than that in healthy subjects (8.8%; OR = 3.63; 95% CI 1.18-11.2). Although the frequency of this mutation in patients with venous thrombosis was higher than that in the patients without venous thrombosis (11.4%), the difference did not reach a statistically significant level (OR = 2.73; 95% CI 0.77-9.70). In BD patients with thrombosis, the frequencies of FV 4070G and PT 20210A were not significantly different compared to the BD patients without venous thrombosis and healthy subjects. CONCLUSIONS: Our results suggest that the FV 1691A, FV 4070G, and PT 20210A mutations are unlikely to play an important role in the pathogenesis of thrombosis in patients with BD.

Adolescent↗

3' end processing of the prothrombin mRNA in thrombophilia.

Clinical and genetic studies have led to the discovery of specific genotypes that predispose to thromboembolism in adults and children. The exploration of the underlying pathologies has revealed a broad variety of affected molecular mechanisms. Most recently, the functional analysis of the prothrombin (F2) 20210*A variant revealed increased efficiency of 3' end processing as a novel genetic mechanism predisposing to human disease. Here, we review the 3' end processing of the human F2 mRNA and demonstrate how clinically relevant mutations in the F2 gene contribute to thrombophilia by interfering with a tightly balanced architecture of noncanonical 3' end formation signals.

3' Flanking Region↗

Evaluation of factor V Leiden, prothrombin and methylenetetrahydrofolate reductase gene mutations in patients with severe pregnancy complications in northern Finland.

BACKGROUND: Thrombosis in placenta may lead to severe pregnancy complications. Most important inherited thrombophilias are factor V Leiden mutation, prothrombin mutation, and methylenetetrahydrofolate reductase mutation. The aim of our research was to evaluate the prevalence of inherited thrombophilias in severe pregnancy complications and in normal pregnancies. MATERIAL AND METHODS: The study subjects with severe preeclampsia, intrauterine growth restriction, placental abruption or fetal death were collected during the period 1999-2004 from Oulu University Hospital. We also collected during the same period voluntary parturients with normal pregnancy outcome as the control group. FVL, FII, and MTHFR gene mutations of the patients and controls were analyzed. RESULTS: We found a significant difference in the prevalence of FVL mutation between the groups. There were 9.5% FVL mutations in the study group compared to 1.8% in the control group; the observed difference between prevalences was 7.7% (95% CI 2.0-13.4). No statistical difference was found in the FII or MTHFR mutations between the groups. All FV and FII mutations were heterozygous and all the MTHFR mutations homozygous. CONCLUSION: Women with thrombophilia have a risk for severe pregnancy complications. Randomized controlled trials are needed to assess the influence of low-molecular-weight heparin in pregnant women with thrombophilia.

Case-Control Studies↗

Antithrombin III versus prothrombin in liver cirrhosis.

In patients with liver cirrhosis, a close relationship was observed between the respective levels of antithrombin III and prothrombin, both below 50% in 20 our 27 patients. The absence of any thrombotic complication, despite low plasma antithrombin III, suggests that the preserved balance between the inhibitor and the zymogens of the inhibited enzymes could have a protective effect against thrombotic tendency.

Adult↗

Standardization of the prothrombin time in oral anticoagulant control.

The establishment of International Reference Preparations for thromboplastin together with a recommended methodology for use has permitted the definition of a universal scale for intensity of oral anticoagulation. This scale is called International Normalized Ratio (INR). INRs can be calculated by using calibrated thromboplastin/instrument systems. A calibration model has been developed together with statistical methods to test this model. The imprecision of calculated INRs has been estimated using information from international collaborative studies and proficiency testing programs. Normalized prothrombin times obtained with calibrated thromboplastin/instrument systems have been shown to provide safe patient care in clinical practice. The development of control plasmas with assigned INR equivalents will complete the standardization system. The INR scale will facilitate the process of consensus-making with respect to optimal therapeutic ranges for anticoagulant intensity. Finally, it will improve the continuity of anticoagulant control of travelling patients.

Administration, Oral↗