Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “IONIZATION”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

Ions generated from uranyl nitrate solutions by electrospray ionization (ESI) and detected with Fourier transform ion-cyclotron resonance (FT-ICR) mass spectrometry.

Electrospray ionization (ESI) of uranyl nitrate solutions generates a wide variety of positively and negatively charged ions, including complex adducts of uranyl ions with methoxy, hydroxy, and nitrate ligands. In the positive ion mode, ions detected by Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry are sensitive to instrumental tuning parameters such as quadrupole operating frequency and trapping time. Positive ions correspond to oligomeric uranyl nitrate species that can be characterized as having a general formula of [(UO(2))(n)(A)(m)(CH(3)OH)(s)](+) or [(UO(2))(n)(O)(A)(m)(CH(3)OH)(s)](+) with n = 1-4, m = 1-7, s = 0 or 1, and A = OH, NO(3), CH(3)O or a combination of these, although the formation of NO(3)-containing species is preferred. In the negative ion mode, complexes of the form [(UO(2))(NO(3))(m)](-) (m = 1-3) are detected, although the formation of the oxo-containing ions [(UO(2))(O)(n)(NO(3))(m)](-) (n = 1-2, m = 1-2) and the hydroxy-containing ions [(UO(2))(OH)(n)(NO(3))(m)](-) (n = 1-2, m = 0-1) are also observed. The extent of coordinative unsaturation of both positive and negative ions can be determined by ligand association/exchange and H/D exchange experiments using D(2)O and CD(3)OD as neutral reaction partners in the gas-phase. Positive ions are of varying stability and reactivity and may fragment extensively upon collision with D(2)O, CD(3)OD and N(2) in sustained off-resonance irradiation/collision-induced dissociation (SORI-CID) experiments. Electron-transfer reactions, presumably occurring during electrospray ionization but also in SORI-CID, can result in reduction of U(VI) to U(V) and perhaps even U(IV).

Calibration↗

Reversed-phase liquid chromatography in-line with negative ionization electrospray mass spectrometry for the characterization of the disulfide-linkages of an immunoglobulin gamma antibody.

In this report, we present a new approach for the determination of the disulfide bond connectivity in proteins using negative ionization mass spectrometry of nonreduced enzymatic digests. The mass spectrometric analysis in negative ion mode was optimized to allow in-line analysis coupled directly to the HPLC system used for the separation of the peptides resulting from enzymatic digestion. We determined the disulfide structure of a human immunoglobulin gamma 2 (IgG2) antibody containing 18 unique cysteine residues linked via 11 unique disulfide bonds. The efficiency of the gas-phase dissociation of disulfide-linked peptides using negative electrospray ionization was evaluated for an ion trap mass spectrometer and an orthogonal acceleration time-of-flight mass spectrometer. Both mass spectrometry techniques provided efficient in-source fragmentation for the identification of the disulfide-linked peptides of the antibody. Both instruments were limited in the number of disulfide bonds that could be dissociated. Seven of the 11 unique disulfide linkages have been determined, including the linkage of the light chain to the heavy chain. Only the disulfide connectivity of the hinge peptide H6H7H8H9 (C6C7VEC8PPC9PAPPVAGPSVFLFPPKPK) could not be determined (numbering the cysteine residues sequentially from the N-terminus and labeling the heavy chain cysteines "H" and the light chain cysteines "L"). However, we identified the dimer of peptide C6C7VEC8PPC9PAPPVAGPSVFLFPPKPK linked via four disulfide bonds based on the unique molecular weight of this dipeptide. The established linkages were H1 to H2, H10 to H11, H12 to H13, L1 to L2, L3 to L4, and L5 to H3H4. The intrachain linkages of the light chain (L1 to L2, L3 to L4), and heavy chain (H10 to H11, H12 to H13) domains were identical to the linkages found in IgG1 antibodies.

Chromatography, High Pressure Liquid↗

Sub parts-per-million mass measurement accuracy of intact proteins and product ions achieved using a dual electrospray ionization quadrupole fourier transform ion cyclotron resonance mass spectrometer.

High mass measurement accuracy (MMA) is demonstrated for intact proteins and subsequent collision-induced dissociation product ions using internal calibration. Internal calibration was accomplished using a dual electrospray ionization source coupled with a hybrid quadrupole Fourier transform ion cyclotron resonance (Q-FT-ICR) mass spectrometer. Initially, analyte ions generated via the first electrospray (ESI) emitter are isolated and dissociated in the external quadrupole. This event is followed by a simultaneous switch to the calibrant ion ESI emitter and a disablement of the isolation and activation of the external quadrupole such that a broad m/z range of calibrant ions are accumulated before injecting the analyte/calibrant ion mixture into the ICR cell. Two different internal calibrant solutions were utilized in these studies to evaluate this approach for the top-down characterization of melittin and ubiquitin. While external calibration of protein fragments resulted in absolute MMA greater than 16 ppm, internal standardization significantly improved upon the MMA of both the intact proteins and their products ions which ranged from -2.0 ppm to 1.1 ppm, with an average of -0.9 ppm. This method requires limited modification to ESI-FT-ICR mass spectrometers and is applicable for both positive and negative ionization modes.

Amino Acid Sequence↗

Application of liquid chromatography-electrospray ionization mass spectrometry for study of steroid-converting enzymes.

A high-performance liquid chromatography-atmospheric pressure ionization-electrospray ionization mass spectrometry (HPLC-API-ESI-MS) method was developed for the analysis of steroids in a study of steroid-converting enzymes. Separations ware done on a Zorbax Eclipse XDB-C18 column (eluted with a linear methanol-water-acetic acid gradient) and identification of the steroids involved was done by API-ESI-MS using positive ion mode and extracted ion analysis. The applicability of the present method for studying steroid metabolism was proven in assaying two steroid-converting enzymes (20beta-hydroxysteroid dehydrogenase and 11beta-hydroxysteroid dehydrogenase) in various biological samples (rat and chicken intestine, chicken oviduct).

11-beta-Hydroxysteroid Dehydrogenases↗

Electron ionization gas chromatography-mass spectrometric determination of residues of thirteen pyrethroid insecticides in whole blood.

A new rapid and sensitive electron ionization gas chromatography-mass spectrometry method in selective ion monitoring mode (SIM) was developed for the determination of l3 synthetic pyrethroid insecticide molecules and their stereo isomers in whole blood. The pyrethroid insecticides investigated are allethrin, bifenthrin, cypermethrin, cyphonothrin, cyfluthrin, lambda-cyhalothrin, deltamethrin, fenvalerate, fenpropathrin, imiprothrin, permethrin, prallethrin and transfluthrin. The residues of pyrethroids are extracted from the whole blood using hexane and acetone mixture (80 + 20%) as solvent. All the pyrethroid residues were separated by using a gas chromatography-mass spectrometry operated in electron ionization mode and quantified in selective ion monitoring mode. The method can detect the residues of different pyrethroids down to the level 0.05-2 ng/ml. Recovery experiments conducted in whole blood samples at the fortification level 1-1000 ng/ml showed 91-103% recovery. The applications of the analytical method for the determination of pyrethroid residues in real samples were tested by analyzing 45 human blood samples collected from the population exposed continuously to different pyrethroid based formulations. The results are confirmed by spiking the known quantity of pyrethroids and subsequently their positive detection.

Gas Chromatography-Mass Spectrometry↗

Sensitive and selective liquid chromatography-electrospray ionization tandem mass spectrometry analysis of hydrochlorothiazide in rat plasma.

A sensitive and selective method for the determination of hydrochlorothiazide (HCTZ) concentrations in rat plasma was developed using high performance liquid chromatography-electrospray ionization tandem mass spectrometry (LC-MS/MS). An aliquot of plasma (50 microl) was mixed with the solution of internal standard, hydrofluorothiazide (HFTZ), and extracted with tert-butyl methyl ether. The reconstituted extract was applied to the LC-MS/MS system with a reversed phase C8 column and eluted with distilled water/acetonitrile (85/15, v/v). To enhance negative ionization of HCTZ and HFTZ in the multiple reaction monitor (MRM), the solution consisting of acetonitlile/1% (v/v) ammonia solution (95/5, v/v) was delivered after column separation. This additional technique, so-called the post-column addition, increased sensitivity of HCTZ and HFTZ about 500- and 200-fold, respectively. The calibration curve showed good linearity (r = 0.999) over the range of 4-1000 ng/ml. Acceptable accuracy (100.8-113.1%) and precision (0.28-16.4%) were confirmed in the intra- and the inter-day analyses. It is indicated that this LC-MS/MS method is useful for pharmacokinetic studies of HCTZ in small animals, because it enabled the serial determination of plasma level of HCTZ in rats.

Animals↗

Determination of tetrabromobisphenol A in human serum by liquid chromatography-electrospray ionization tandem mass spectrometry.

A method for the determination of tetrabromobisphenol A (TBBPA) in human serum utilizing solid-phase extractions (SPEs) and liquid chromatography (LC) with electrospray ionization tandem MS (MS/MS) has been developed. After purification and concentration of TBBPA using consecutive SPEs on reversed-phase and normal-phase cartridges, the serum sample was subjected to LC. TBBPA was separated on a C18 reversed-phase column by gradient elution with a mixture of water, methanol, and acetonitrile as the mobile phase, and then detected with electrospray ionization MS/MS in negative ion mode. 13C12-TBBPA was suitable as an internal standard for the reproducible determination of TBBPA in human serum samples (5 g). The method has been validated in TBBPA concentration range of 5-100 pg per g serum, and the recoveries in the concentration range were higher than 83.3%. The repeatabilities of the proposed method of non-spiked control serum (6.3 pg per g serum) and spiked serum (added 5-100 pg per g serum) were within 10.0% as relative standard deviations. The limit of quantification (LOQ) for TBBPA was 4.1 pg per g serum, which was corresponded to 0.63 fmol on column.

Chromatography, Liquid↗

Simultaneous determination of gentisic, salicyluric and salicylic acid in human plasma using solid-phase extraction, liquid chromatography and electrospray ionization mass spectrometry.

A method is developed for the simultaneous extraction of gentisic (GA), salicyluric (SUA) and salicylic acid (SA) in human plasma from Willow Bark extract, by solid phase extraction (SPE) using Waters Oasis HLB (divinylbenzene-n-vinylpyrrolidone copolymer) cartridges. Also, a method is optimized comprising of reversed-phase (RP) high-performance liquid chromatography (HPLC) in connection with electrospray ionization mass spectrometry (ESI-MS), fluorescence detection (FLD) and photo diode array detection (DAD) to identify and quantify GA, SUA and SA in the SPE effluents. An improved sensitivity regarding the lower detection limit (LOD) of < 7 ng/ml, the limit of quantitation (LOQ) of 20 ng/ml and short analysis times of < 15 min is required. The validated SPE method shows linearity in the range of 9.0-58.2 ng/ml for GA, 9.4-191.5 ng/ml for SUA and 12.8-1101.6 ng/ml for SA. The correlation coefficient values are > 0.9994 and 0.99 for fluorescence detection (FLD) and electrospray ionization mass spectrometry (ESI-MS), respectively. The recoveries are from 91.3-102.1% for gentisic acid (GA), 86.8-100.5% for salicyluric acid (SUA) and 75.8-81.4% for salicylic acid (SA) depending on the starting concentrations. RP-LC-ESI-MS/MS studies using collision induced dissociation (CID) confirm that the investigated analytes are not artifacts and facilitate further specific identification in addition to the determination of the parent ion mass even in the presence of co-eluting peaks. The established method is also used to analyze gentisic (GA), salicyluric (SUA) and salicylic acid (SA), not only after intake of Willow Bark capsules (Assalix, BNO 1455) but also as naturally occurring constituents in human plasma after the intake of salicylic acid containing foods.

Calibration↗

p-Toluenesulfonyl isocyanate as a novel derivatization reagent to enhance the electrospray ionization and its application in the determination of two stereo isomers of 3-hydroxyl-7-methyl-norethynodrel in plasma.

In this paper, p-toluenesulfonyl isocyanate has been reported as a novel derivatization reagent with strong nuclephilic reactivity for the hydroxyl compounds. The derivatization for the two pharmacologically active 3-hydroxyl metabolites, 3alpha-hydroxyl-7-methyl-norethynodrel and 3beta-hydroxyl-7-methyl-norethynodrel by p-toluenesulfonyl isocyanate can be accomplished in 2 min under room temperature. The offline derivatization procedure introduced an easily ionizable sulfonylcarbamic ester moiety to the metabolites. This greatly improved the analyte's sensitivity in negative electrospray ionization and enabled us to achieve the desired lower limit of quantitation at 100 pg/ml in plasma. Therefore, a sensitive high performance liquid chromatography-mass spectrometry (HPLC-MS) method for the analysis of the two stereo isomers was developed. The method had been validated to be accurate, precise, and sensitive, and can be used for the metabolism pharmacokinetic study of tibolone in human subjects.

Chromatography, High Pressure Liquid↗

Determination of talinolol in human plasma using automated on-line solid phase extraction combined with atmospheric pressure chemical ionization tandem mass spectrometry.

A specific LC-MS/MS assay was developed for the automated determination of talinolol in human plasma, using on-line solid phase extraction system (prospekt 2) combined with atmospheric pressure chemical ionization (APCI) tandem mass spectrometry. The method involved simple precipitation of plasma proteins with perchloric acid (contained propranolol) as the internal standard (IS) and injection of the supernatant onto a C8 End Capped (10 mmx2 mm) cartridge without any evaporation step. Using the back-flush mode, the analytes were transferred onto an analytical column (XTerra C18, 50 mmx4.6 mm) for chromatographic separation and mass spectrometry detection. One of the particularities of the assay is that the SPE cartridge is used as a column switching device and not as an SPE cartridge. Therefore, the same SPE cartridge could be used more than 28 times, significantly reducing the analysis cost. APCI ionization was selected to overcome any potential matrix suppression effects because the analyte and IS co-eluted. The mean precision and accuracy in the concentration range 2.5-200 ng/mL was found to be 103% and 7.4%, respectively. The data was assessed from QC samples during the validation phase of the assay. The lower limit of quantification was 2.5 ng/mL, using a 250 microL plasma aliquot. The LC-MS/MS method provided the requisite selectivity, sensitivity, robustness accuracy and precision to assess pharmacokinetics of the compound in several hundred human plasma samples.

Automation↗

Quantification of lipoic acid in plasma by high-performance liquid chromatography-electrospray ionization mass spectrometry.

A sensitive and specific liquid chromatography electrospray ionization mass spectrometry (LC-ESI-MS) method has been developed and validated for the identification and quantification of lipoic acid (LA) in human plasma. LA and the internal standard, naproxen, were extracted from a 500 microl plasma sample by one-step deproteination using acetonitrile. Chromatographic separation was performed on a Zorbax SB-C(18) Column (100 mmx3.0mm i.d. with 3.5 microm particle size) with the mobile phase consisting of acetonitrile and 0.1% acetic acid (pH 4, adjusted with ammonia solution) (65:35, v/v), and the flow rate was set at 0.3 ml/min. Detection was performed on a single quadrupole mass spectrometer by selected ion monitoring (SIM) mode via electrospray ionization (ESI) source. The method was linear over the concentration range of 5-10,000 ng/ml for LA. The intra- and inter-day precisions were less than 7% and accuracy ranged from -7.87 to 9.74% at the LA concentrations tested. The present method provides a relatively simple and sensitive assay with short turn-around time. The method has been successfully applied to a clinical pharmacokinetic study of LA in 10 healthy subjects.

Administration, Oral↗

Quantitation of salbutamol in human urine by liquid chromatography-electrospray ionization mass spectrometry.

A sensitive and specific liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) is described for quantitation of salbutamol in human urine using nadolol as the internal standard (I.S.). Urine samples were hydrolyzed with beta-glucuronidase followed by a solid-phase extraction procedure using Bond Elut-Certify cartridges. The HPLC column was an Agilent Zorbax SB-C(18) column. A mixture of 0.01 M ammonium formate buffer (pH 3.5)-acetonitrile (85:15, v/v) was used as the mobile phase. Analytes were quantitated using positive electrospray ionization in a quadrupole spectrometer. Selected ion monitoring (SIM) mode was used to monitor m/z 166 for salbutamol and m/z 310 for I.S. Good linearity was obtained in the range of 10.0-2000.0 ng/ml. The limit of quantification was 10.0 ng/ml. The intra- and inter-run precision, calculated from quality control (QC) samples was less than 7.3%. The accuracy as determined from QC samples was within +/-2.6%. The method was applied for determining excretion curves of salbutamol.

Albuterol↗

Selective method for the determination of cefdinir in human plasma using liquid chromatography electrospray ionization tandam mass spectrometry.

A sensitive and selective liquid chromatographic-tandem mass spectrometric (LC-MS/MS) method was developed for the determination of cefdinir in human plasma. After a simple protein precipitation using trichloracetic acid, the post-treatment samples were applied to a prepacked RP18 Waters SymmetryShield column interfaced with a triple quadrupole tandem mass spectrometer. Positive electrospray ionization was employed as the ionization source. The mobile phase consisted of methanol-water-formic acid (25:75:0.075, v/v/v). The analyte and I.S. cefaclor were both detected by the use of selected reaction monitoring mode. The method was linear in the concentration range of 5-2,000 ng/ml. The lower limit of quantification was 5 ng/ml. The intra- and inter-day relative standard deviation across three validation runs over the entire concentration range was less than 4.3%. The accuracy determined at three concentrations (36, 360 and 1,800 ng/ml for cefdinir) ranged from 99.6 to 106.7% in terms of recovery. The chromatographic run time for each plasma sample was less than 3 min. The method herein described was successfully applied for the evaluation of pharmacokinetic profiles of cefdinir capsule in 12 healthy volunteers.

Anti-Infective Agents↗

Liquid chromatography electrospray ionization mass spectrometry analysis of the ocular metabolites from a short interfering RNA duplex.

The ocular metabolism of an siRNA duplex, SIRNA-027, was examined by ion-pair reversed-phase liquid chromatography (IP-RP-LC) coupled to electrospray ionization mass spectrometry (ESI-MS). The RNA duplex was injected intraocularly into the eyes of New Zealand white rabbits. Rabbits were sacrificed at different timepoints and the vitreous and retina/choroid tissue analyzed for siRNA by IP-RP-LC-MS. The method used a hexafluoroisopropanol (HFIP)/triethylamine (TEA) ion-pairing buffer with a methanol gradient. Using electrospray ionization, the duplex was preserved in the gas phase for analysis by a triple quadrupole mass spectrometer. With this methodology metabolites from rabbit ocular vitreous humor and retina/choroid tissue were identified and a pattern of siRNA degradation was established. Results showed that the duplex was metabolized predominantly from one end. This end of the siRNA duplex was calculated to have the weakest binding energy of the two ends indicating that the ability of the siRNA to split into single strands is a factor in its degradation.

Animals↗

Isolation of lipids from photosystem I complex and its characterization with high performance liquid chromatography/electrospray ionization mass spectrometry.

A method for simultaneous analysis of lipids extracted from photosystem I complex was developed with high performance liquid chromatography/electrospray ionization mass spectrometry. The photosystem I complex was firstly solubilized and separated using deoxycholate polyacrylamide gel electrophoresis method after ultrasonic treatment of the sample (leaves of pea, Pisum sativum L.). The Photosystem I complexes were electrophoretically eluted from the deoxycholate polyacrylamide gel electrophoresis bands containing them, and the electron transport activity of the eluent measured as confirmation. Lipids, which were isolated from the complex having photosystem I activity, were separated and characterized with high performance liquid chromatography/electrospray ionization mass spectrometry. Five lipids, monogalactosyldiacylglycerol, digalactosyldiacylglycerol, phosphatidylglycerol, sulphoquinovosyldiacylglycerol and phosphaditylcholine were found combining with photosystem I complex. Different species of these lipids were found in the ESI mass spectra and the compositions of the acyl groups in them were determined.

Chromatography, High Pressure Liquid↗

Investigation of high-throughput ultrafiltration for the determination of an unbound compound in human plasma using liquid chromatography and tandem mass spectrometry with electrospray ionization.

A high-throughput ultrafiltration method with a direct injection assay has been developed to determine unbound concentrations of a high-protein binding compound, an alpha(v)beta(3) bone integrin antagonist (I), in human plasma for a clinical pharmacokinetic study. The 96-well MultiScreen filter plate with Ultracel-PPB membrane was evaluated for the separation of unbound from protein-bound compound I by ultrafiltration. The sample preparation was automated using a Packard MultiPROBE II EX liquid handling system to transfer the plasma samples to the 96-well PPB plate for centrifugation and to prepare ultrafiltrate samples for analysis. Using on-line extraction with a column-switching setup for sample clean-up and separation, the ultrafiltrate samples were directly injected onto a reversed-phase HPLC system and analyzed using a mass spectrometer interfaced with an electrospray ionization (ESI) source in the positive ionization mode (LC/ESI-MS/MS). The performance of the ultrafiltration using Ultracel-PPB 96-well plate for unbound I analysis was evaluated and optimized with respect to sample volume, centrifugation temperature, speed and time, and the relationship of the well positions of the PPB plate versus filtrate volumes and concentrations. The assay intraday accuracy and precision were between 93.9 and 104.8 and <7.3% (CV), respectively. The linear range of the calibration curve for the assay was 0.1-500 ng/mL on a Finnigan TSQ Quantum LC/ESI-MS/MS system. Evaluation and validation of the unbound plasma assay demonstrated it to be rapid, sensitive and reproducible.

Centrifugation↗

Determination of bencycloquidium bromide in rat plasma by liquid chromatography-electrospray ionization-mass spectrometry.

A liquid chromatography-electrospray ionization-mass spectrometry (LC-ESI-MS) assay for the determination of bencycloquidium bromide (BCQB) in rat plasma was firstly developed and validated. After addition of 1-ethyl-bencycloquidium bromide as an internal standard (I.S.), the plasma samples were deproteinized with methanol and the supernatant was assayed by LC-ESI-MS. Chromatographic separation was achieved with a Hanbon Lichrospher 5-C18 column. The mobile phase consisted of methanol-40 mM ammonium acetate buffer-formic acid (75:25:0.25, v/v/v) and delivered at the flow rate of 1.0 ml/min. LC-ESI-MS was carried out on a single quadrupole mass spectrometer using electrospray ionization (ESI) and positive selected-ion monitoring (SIM). Target ions were monitored at [M](+)m/z 330.2 for BCQB and [M] (+)m/z 344.2 for I.S. Calibration curve was linear over the range of 3-1500 ng/ml. The lower limit of quantification (LLOQ) was 3.0 ng/ml. The intra- and inter-run relative standard deviations (R.S.D.%) of the assay were less than 7.1 and 12.3%, respectively. The accuracy determined at the concentrations of 3.0, 100.0, 500.0 and 1500 ng/ml for BCQB were within +/-15.0%. The established method has been applied successfully to study the pharmacokinetics of BCQB in rats after intranasal administration.

Animals↗

Liquid chromatographic-electrospray ionization mass spectrometric quantitative analysis of buprenorphine, norbuprenorphine, nordiazepam and oxazepam in rat plasma.

A liquid chromatographic-mass spectrometric method with electrospray ionization is presented for the simultaneous determination of buprenorphine, nordiazepam and their pharmacologically active metabolites, norbuprenorphine and oxazepam, in rat plasma. The drugs were extracted from plasma by liquid-liquid extraction and chromatographically separated using a gradient elution of aqueous ammonium formate and acetonitrile. Following electrospray ionization, the analytes were quantified in the single ion storage mode. The assay was validated according to current acceptance criteria for bioanalytical method validation. It was proved to be linear from 0.7 to 200 ng/ml plasma for buprenorphine, 1.0 to 200 ng/ml for norbuprenorphine, 2.0 to 200 ng/ml for nordiazepam, and from 5.0 to 200 ng/ml for oxazepam. The average recoveries of buprenorphine, norbuprenorphine, nordiazepam and oxazepam were 89, 39, 88 and 82%, respectively, with average coefficients of variation ranging from 1.8 to 14.3%. The limits of quantitation for these drugs were 0.7, 1.0, 2.0 and 5.0 ng/ml, respectively, with associated precisions within 17% and accuracies within +/-18% of the nominal values. Both the intra- and inter-assay precision values did not exceed 11.3% for the four analytes. Intra- and inter-assay accuracies lay within +/-15% of the nominal values. The validated method was applied to the determination of buprenorphine, norbuprenorphine, nordiazepam and oxazepam in plasma samples collected from rats at various times after intravenous administration of buprenorphine and nordiazepam.

Animals↗