Search PubMed⌕ Search

SEARCH · Search PubMed

Results for “Fractures, Compression”

Search indexed PubMed citations on genomics, clinical trials, systematic reviews and public health. Explore titles, authors and supplied subject terms, then open the PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,747 records · Page 97Linked to original sources

[Treatment of fresh fractures of the dens axis by compression screw osteosynthesis].

Today most fractures of the odontoid process are treated conservatively. In 32% a bony stabilization is not achieved. Therefore each third has to have a secondary operation, because the only life-threatening psuedoarthrosis is one in the odontoid process of the axis. For this reason the question is repeatedly raised, whether better results will be achieved by on early primary operation. The advantages of the compression-screw osteosynthesis are compared with the well-known operative procedures. The operative management is described. An illustrative case in regard to diagnostic operation and follow up study is described.

Axis, Cervical Vertebra↗

New concepts for bone fracture treatment and the Locking Compression Plate.

The operative treatment of bone fractures using plates and screws is a standard successful technique. Internal fixation with plates and screws leads to additional trauma and disturbance of the bone blood supply, which increases the risk of delayed union and infection. However, problems also are encountered in the fixation of osteoporotic bone. The locked internal fixator technique is an approach to optimize internal fixation. It aims at flexible elastic fixation to imitate spontaneous healing, including induction of callus formation. The technology supports what is currently called "minimally invasive plate osteosynthesis" (MIPO), which provides priority to biology over mechanics. An implant system called "Locking Compression Plate (LCP)" was developed, based on many years of experience with compression plating and good clinical results obtained with internal fixators, such as the Less Invasive Stabilization Systems (LISS). It combines the two treatment methods (ie, the compression plating and locked internal fixation methods) into one system. This chapter describes the basic principles of locked internal fixators and some clinical results with the LISS and LCP systems to illustrate the potential of these new systems.

Bone Plates↗

Treatment of unstable intertrochanteric fractures with anatomic reduction and compression hip screw fixation.

One hundred sixty-two cases of unstable intertrochanteric fractures treated by anatomic reduction and compression hip screw fixation were reviewed. One hundred twenty-four of these patients were followed up for an average of 19.2 months. Loss of fixation, with varus angulation of the fracture, occurred in five patients, a 4% incidence of failure. One hundred ten patients were bearing full weight an average of three weeks after operation. Fracture healing occurred an average of 18 weeks after operation. After compression was applied, 90% of the fractures moved into medial displacement position. Eight percent of the fractures laterally displaced; 2% of the fractures maintained their anatomic alignment. Nonanatomic reduction, e.g., stable reduction accomplished by displacement osteotomy (after Dimon and Hughston), has no advantage over anatomic reduction and fixation by a compression hip screw. The advantages of the latter technique are that weight-bearing can be started early, the device can be used for stable and unstable intertrochanteric fractures with identical technique, and fixation is rigid and allows for compression of the fracture site, while maintaining alignment.

Adult↗

A case of post-traumatic syringomyelia. Neuropathological findings after 1 year of cystic drainage.

A 58-year-old man sustained C4-C5 post-traumatic myelopathy with C3-C4 subluxation, slight compression of C3 vertebral body, C4 spinous process fracture and C6 compression fracture. He subsequently developed syringomyelia from C4 to C6, which was shunted into the subarachnoid space. Postoperatively, there was some but insignificant improvement of his symptoms although a postoperative metrizamide spinal computerised tomography showed complete drainage of the cyst. This patient died 1 year later. Autopsy examination of the spinal cord showed extensive damage of the posterior half of the cord at C3-C4 but the damage was much less extensive from C4 to C6 (where the syrinx was located), affecting mainly the right dorsal column at C4 and the right dorsal column and right anterior horn at C5-C6. In this patient, the syrinx developed in the partially damaged segments of the cord at the level of the spinal fractures and complete drainage of the cyst was not followed by satisfactory relief of his symptoms.

Humans↗

Percutaneous compression plating of intertrochanteric hip fractures.

OBJECTIVE: To present the principles of a surgical technique for percutaneous compression plating of intertrochanteric hip fractures and to report the clinical results of treatment using this method. DESIGN: Retrospective. SETTING: University hospital. PATIENTS: Ninety-eight intertrochanteric hip fractures in ninety-seven patients with a minimum follow-up of twelve months. MAIN OUTCOME MEASURES: Radiographic and clinical evidence of functional outcome and complications including fracture collapse and implant failure. RESULTS: Mean perioperative blood loss was 92.4 milliliters (range 14 to 245 milliliters), and the mean postoperative hospital stay was 8.7 days (range 4 to 20 days). Complications included two minor wound hematomas and one soft tissue infection. Radiographically, one fracture with a varus deformity of 8 degrees and two fractures had minor screw pullout that did not affect the final results. No collapses, screw cutouts, or head penetrations were seen. Three patients required reoperation: one for avascular necrosis after a fracture at the base of the neck and two, after fracture healing, for trochanteric bursitis requiring plate removal. All surviving patients (80 of 98; 82 percent) had uneventful fracture healing with union achieved by six months in all patients. CONCLUSIONS: Use of the percutaneous compression plating for intertrochanteric hip fractures resulted in reduced complications, event-free fracture healing, and improved rehabilitation.

Aged↗

Anomalous effect of compression pressure on the brittle fracture tendency of alpha-cellulose tablets.

The effect of varying the compression pressure on the brittle fracture tendency of alpha-cellulose and lactose tablets has been investigated. Tablet tensile strength, (T), packing fraction, (Pf), and brittle fracture index (BFI) were determined at different compression pressures (0.82, 1.22 and 1.63 MPa). In another aspect of the study, alpha-cellulose and tapioca powders were mixed in various proportions to obtain powders of varying plastoelasticity. Their tableting characteristics T, Pf and BFI were also determined at the different compression pressures. The polymer, alpha-cellulose displayed the characteristics of plastic compression--a low BFI but high T and Pf values while lactose displayed the characteristics of elastic compression--a high BFI but low T and Pf values. The degree of plastic compression decreased as the proportion of tapioca in the powder mixture increased from 0 to 50% w/w. Higher concentrations of tapioca >50% produced crumbly tablets at all compression pressures, thus indicating that tapioca is highly elastic. Increase in the compression pressure caused an increase in the BFI values of lactose tablets, 0.39-0.76 but a decrease in the BFI values of alpha-cellulose tablets, 0.38-0.09. This decrease became less pronounced as the plasticity of the powder mixtures decreased. The difference in the response of the tablets to the change in compression pressure relates to the difference in the plastoelasticity of the materials tested.

Cellulose↗

Internal fixation of proximal humeral fractures with a locking compression plate: a retrospective evaluation of 72 patients followed for a minimum of 1 year.

BACKGROUND: Proximal humeral fractures, particularly in osteoporotic patients, remain an unsolved problem as regards the durability of the osteosynthesis. The AO/ASIF group has developed a new technique which aims to preserve the biological integrity of the humeral head and secures the reduction using multiple locking screws with angular stability (Philos), thus allowing an early mobilization. PATIENTS AND OUTCOME: We retrospectively reviewed the complications and functional outcome after a minimum follow-up of 1 year in 72 patients treated with this new method. 2 fractures failed to unite, and 3 patients developed an avascular necrosis of the humeral head. In addition, 2 implant failures were observed due to a technical error. According to the Constant score, the functional outcome was acceptable even in elderly patients. INTERPRETATION: The Philos method appears to be safe and can be recommended for the treatment of proximal humeral fractures in patients with poor bone quality.

Adult↗

Blepharoptosis caused from compression of levator muscle by fractured orbital roof fragment.

The authors report two cases of blepharoptosis caused by compression of the levator muscle by fractured orbital roof fragment; both were improved by surgical treatments. In one case, because neurosurgeons were concerned with the contusional hemorrhage of the right frontal lobe during the early admission period, they missed the orbital roof fracture. The patient underwent surgery on the 18th post-trauma day. In the other case, the early diagnosis was made, and the surgical treatment were performed on the 10th post-trauma day. The authors think if the blepharoptosis is not improved in several days and the fractured fragment is suspected to compress the levator in computed tomography scan, surgical decompression is necessary and should be performed as soon as possible.

Adult↗

Formation of impacted fractures of the femoral neck: an experimental study.

Nine femoral-neck specimens were exposed to a fracturing force applied to the femoral head, perpendicular to the axis of the femur, simulating a fall onto the greater trochanter. The mechanical strength and fracture type were investigated in a universal testing machine. In all nine specimens, the superior (cranial) cortex of the femoral neck fractured first, followed by some compression and fracture of the inferior cortex, whereby impacted fractures had been formed. After application of additional force, dislocated fractures occurred. This method may be of value in experimental studies of impacted fractures of the femoral neck. RELEVANCE: This study describes an experimental procedure for formation of impacted femoral neck fractures. Hopefully this technique may be employed in further examining the nature and biomechanics of impacted hip fractures. The ultimate aim would seem to be a classification with regard to which fractures require surgery and which may be treated conservatively.

Journal Article↗

Hybrid fracture and the transition from extension fracture to shear fracture.

Fracture is a fundamental mechanism of material failure. Two basic types of brittle fractures are commonly observed in rock deformation experiments--extension (opening mode) fractures and shear fractures. For nearly half a century it has been hypothesized that extension and shear fractures represent end-members of a continuous spectrum of brittle fracture types. However, observations of transitional fractures that display both opening and shear modes (hybrids) in naturally deformed rock have often remained ambiguous, and a clear demonstration of hybrid fracture formation has not been provided by experiments. Here we present the results of triaxial extension experiments on Carrara marble that show a continuous transition from extension fracture to shear fracture with an increase in compressive stress. Hybrid fractures form under mixed tensile and compressive stress states at acute angles to the maximum principal compressive stress. Fracture angles are greater than those observed for extension fractures and less than those observed for shear fractures. Fracture surfaces also display a progressive change from an extension to shear fracture morphology.

Journal Article↗

Mandibular fracture reduction with eccentric dynamic compression plate: new treatment for an old problem.

We describe a technique and theory of application of the Eccentric Dynamic Compression Plate (EDCP) and the Dynamic Compression Plate (DCP) for mandibular fracture fixation, developed by Speissl in Switzerland, and our experience with the application of 15 plates in ten edentulous or nearly edentulous patients over the past 18 months. While we have had soft tissue infections in 4 of 15 fracture sites, our results reveal satisfactory bony healing in 14 of 15 fracture sites. We, therefore, believe that while this technique is still in the infant stages of clinical application in the United States, it has the potential to revolutionize the thinking and practice of mandibular fracture therapy.

Bone Plates↗

Pseudoaneurysm of the superior gluteal arterial system: an unusual cause of pain after a pelvic fracture.

This case report describes a complication after treatment of a rotationally unstable pelvic fracture: a pseudoaneurysm of the superior gluteal arterial system. The patient sustained an anterior-posterior compression pelvic fracture that was stabilized with anterior symphyseal plating and percutaneous iliosacral screw insertion. The etiology of the pseudoaneurysm was likely multifactorial, including the injury (anterior-posterior compression pelvic fracture), prolonged coagulation parameters during administration of warfarin, and the percutaneous insertion of an iliosacral lag screw. A pseudoaneurysm of the superior gluteal arterial system should be included in the differential diagnosis of unexplained pelvic or buttock pain after a pelvic fracture.

Adult↗

Preliminary report of a compression technique to apply tension to sliding bone grafts in tibial shaft fractures.

A new compression device is described that applies tension to sliding bone grafts on the medial aspect of the tibia in tibial shaft fractures. The mechanical aspects of the operation are outlined and the advantages and disadvantages of the system discussed. There have been no complications and rigidity has been obtained in two clinical cases. Mechanical tests in bending and torsion show that rigidity can be obtained without breaking the graft.

Bone Transplantation↗

Micro-scale measurement of the mechanical properties of compressed pharmaceutical powders. 1: The elasticity and fracture behavior of microcrystalline cellulose.

The feasibility of using very small compacts ( approximately 8.0 x 4.5 x 0.4 mm; approximately 20 mg) to determine the elasticity and fracture behavior of compressed pharmaceutical powders using the three-point beam-bending technique was evaluated. Compacts of microcrystalline cellulose with a range of porosities were tested using a thermomechanical analyzer and values for the Young's modulus and critical stress intensity factor at zero porosity (E(0) and K(IC0)) were determined by extrapolation. The value of E(0) measured at ambient relative humidity on un-notched beams was found to be in close agreement with that reported for much larger samples, and the value of K(IC0) for the small notched compacts was at the lower limit of the accepted range of values for microcrystalline cellulose. The fracture toughness (R) and total energy of fracture (U) for the notched specimens were also determined and used to estimate the apparent surface energies for crack initiation (gamma(i)) and for total fracture (gamma(f)). To further probe the utility of the micro-scale mechanical testing techniques, the effects of humidity on the various mechanical properties of the small microcrystalline compacts were examined and it was found that E(0), K(IC0), R(0), gamma(i0) and gamma(f0) each decreased as the surrounding humidity (and water content of the samples) increased.

Algorithms↗